954 resultados para Ion-Selective Electrodes


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The self-assembly of p-pyridyl-ended oligo-p-phenylenevinylenes (OPVs) in ethanol leads to the formation of either hollow or solid microrods. The corresponding protonated OPVs with n-butyl chains induce transparent gelation and also gel phase crystallization owing to various synergistic noncovalent interactions. The chloride ion-selective gelation, AIEE and stimuli responsiveness of the gel are also observed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Herein we present an inexpensive facile wet-chemistry-free approach to the transfer of chemical vapour-deposited multiwalled carbon nanotubes to flexible transparent polymer substrates in a single-step process. By controlling the nanotube length, we demonstrate accurate control over the electrical conductivity and optical transparency of the transferred thin films. Uniaxial strains of up to 140% induced only minor reductions in sample conductivity, opening up a number of applications in stretchable electronics. Nanotube alignment offers enhanced functionality for applications such as polarisation selective electrodes and flexible supercapacitor substrates. A capacitance of 17F/g was determined for supercapacitors fabricated from the reported dry-transferred MWCNTs with the corresponding cyclic voltagrams showing a clear dependence on nanotube length. © 2012 Matthew Cole et al.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a poly(vinyl chloride) (PVC) membrane electrode is prepared for gemfibrozil, 2, 2-dimethyl-5(2,5-xylyloxy) valeric acid, based on its ion pair complexes with hexadecyltrioctyl ammonium iodide (HTOA). The membrane composition of the electrode was optimized by using the sequential level elimination method for orthogonal experimental design. The electrode has a Nernstian response range from 2.5 X 10(-5) to 0.1 mol/l with an average slope of 55.3 mV/decade. The limit of detection is 7.1 X 10(-6) mol/l. The electrode responses were not affected by pH in the range 10.0-12.3. A Na2B4O7-Na2CO3 buffer of pH = 11.0 was selected as the background electrolyte solution for potentiometric measurements. The electrode was used for determining gemfibrozil in pharmaceutical preparations with satisfactory results.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper mainly reviewed the background, application and development on environmental electroanalytical chemistry, 79 literatures were cited.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The potential of employing zinc polycarboxylate dental cement as a controlled release material has been studied. Benzalkonium chloride was used as the active ingredient, and incorporated at concentrations of 1, 2 and 3% by mass within the cement. At these levels, there was no observable effect on the speed of setting. Release was followed using an ion-selective electrode to determine changes in chloride ion concentration with time. This technique showed that the additive was released when the cured cement was placed in water, with release occurring by a diffusion mechanism for the first 3 h, but continuing beyond that for up to 1 week. Diffusion coefficients were in the range 5.62 × 10(−6) cm(2) s(−1) (for 1% concentration) to 10.90 × 10(−6) cm(2) s(−1) (for 3% concentration). Up to 3% of the total loading of benzalkonium chloride was released from the zinc polycarboxylate after a week, which is similar to that found in previous studies with glass-ionomer cement. It is concluded that zinc polycarboxylate cement is capable of acting as a useful material for the controlled release of active organic compounds.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fluctuations in ammonium (NH4+), measured as NH4-N loads using an ion-selective electrode installed at the inlet of a sewage treatment plant, showed a distinctive pattern which was associated to weekly (i.e., commuters) and seasonal (i.e., holidays) fluctuations of the population. Moreover, population size estimates based on NH4-N loads were lower compared to census data. Diurnal profiles of benzoylecgonine (BE) and 11-nor-9-carboxy-Δ9-tetrahydrocannabinol (THC-COOH) were shown to be strongly correlated to NH4-N. Characteristic patterns, which reflect the prolonged nocturnal activity of people during the weekend, could be observed for BE, cocaine, and a major metabolite of MDMA (i.e., 4-hydroxy-3-methoxymethamphetamine). Additional 24 h composite samples were collected between February and September 2013. Per-capita loads (i.e., grams per day per 1000 inhabitants) were computed using census data and NH4-N measurements. Normalization with NH4-N did not modify the overall pattern, suggesting that the magnitude of fluctuations in the size of the population is negligible compared to those of illicit drug loads. Results show that fluctuations in the size of the population over longer periods of time or during major events can be monitored using NH4-N loads: either using raw NH4-N loads or population size estimates based on NH4-N loads, if information about site-specific NH4-N population equivalents is available.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Les résultats présentés dans cette thèse précisent certains aspects de la fonction du cotransporteur Na+/glucose (SGLT1), une protéine transmembranaire qui utilise le gradient électrochimique favorable des ions Na+ afin d’accumuler le glucose à l’intérieur des cellules épithéliales de l’intestin grêle et du rein. Nous avons tout d’abord utilisé l’électrophysiologie à deux microélectrodes sur des ovocytes de xénope afin d’identifier les ions qui constituaient le courant de fuite de SGLT1, un courant mesuré en absence de glucose qui est découplé de la stoechiométrie stricte de 2 Na+/1 glucose caractérisant le cotransport. Nos résultats ont démontré que des cations comme le Li+, le K+ et le Cs+, qui n’interagissent que faiblement avec les sites de liaison de SGLT1 et ne permettent pas les conformations engendrées par la liaison du Na+, pouvaient néanmoins générer un courant de fuite d’amplitude comparable à celui mesuré en présence de Na+. Ceci suggère que le courant de fuite traverse SGLT1 en utilisant une voie de perméation différente de celle définie par les changements de conformation propres au cotransport Na+/glucose, possiblement similaire à celle empruntée par la perméabilité à l’eau passive. Dans un deuxième temps, nous avons cherché à estimer la vitesse des cycles de cotransport de SGLT1 à l’aide de la technique de la trappe ionique, selon laquelle le large bout d’une électrode sélective (~100 μm) est pressé contre la membrane plasmique d’un ovocyte et circonscrit ainsi un petit volume de solution extracellulaire que l’on nomme la trappe. Les variations de concentration ionique se produisant dans la trappe en conséquence de l’activité de SGLT1 nous ont permis de déduire que le cotransport Na+/glucose s’effectuait à un rythme d’environ 13 s-1 lorsque le potentiel membranaire était fixé à -155 mV. Suite à cela, nous nous sommes intéressés au développement d’un modèle cinétique de SGLT1. En se servant de l’algorithme du recuit simulé, nous avons construit un schéma cinétique à 7 états reproduisant de façon précise les courants du cotransporteur en fonction du Na+ et du glucose extracellulaire. Notre modèle prédit qu’en présence d’une concentration saturante de glucose, la réorientation dans la membrane de SGLT1 suivant le relâchement intracellulaire de ses substrats est l’étape qui limite la vitesse de cotransport.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The effect of dietary sodium restriction on perceived intensity of and preference for the taste of salt was evaluated in 76 adults, 25-49 years, with diastolic blood pressure between 79-90 mmHg. Participants were volunteers from clinical Hypertension Prevention Trials (HPT), at the University of California, Davis and the University of Minnesota, Minneapolis. Participants followed one of four HPT diets: 1600 mg Na+/day (NA, n=lS), 1600 mg Na+ plus 3200 mg K+/day (NK, n=lS), 1600 mg Na+/day plus energy restriction to achieve weight loss (NW, n=l3) and weight loss only (WT, n=l3). All participants attended regularly scheduled nutri­tion intervention meetings designed to help them achieve the HPT dietary goals. A fifth, no-intervention group, consisted of 20, no-diet-change controls CCN). Sodium, potassium and energy intakes were monitored by analysis of single, 24-hour food records and corresponding overnight urine speci­mens, obtained at baseline and after 12 and 24 weeks of intervention. Hedonic responses to sodium chloride in a prepared cream of green bean soup were assessed by two methods : 1) scaling of like/dislike for an NaCl concentration series on 10-cm graphie line scales and 2) ad libitum mixing of unsalted and salted soups to maximum level of liking. Salt content of the mixes was analyzed by sodium ion-selective electrode. The concentration series was also rated for perceived saltiness­intensity on similar graphie line scales. Tests were conducted at base­line and after approximately 1, 3, 6, 8, 10, 13 and 24 weeks of intervention. Reduction in sodium intake and excretion in NA, NK and NW partici­pants was accompanied by a shift in preference toward less saltiness in soup. The pattern of hedonic responses changed over time: scores for high NaCl concentrations decreased progressively while scores for low concentrations increased. Hedonic maxima shifted fran a concentration of 0.55% at the onset to 0.1-0.2% added NaCl at week 24. During the same time period, the preferred concentration of ad libitum mixes declined 50%. These shifts occurred independently of changes in salti­ness intensity ratings, potassium or energy intakes, and were consistent across the two participating study sites. Like/dislike and sd. libitum responses were similar after 13 and 24 weeks of diet, as were measures of sodium intake and excretion. These findings suggest that after three months of sodium restriction, preference for salt had readjusted to a lower level, reflective of lower sodium intake. Mechanisms underlying the change in preference are unclear, but may include sensory, context, physiological as well as behavioral effects. In contrast, few changes were noted within WT and CN groups. The pattern of hedonic responses varied little in controls while the WT group showed increased liking for mid-range NaCl concentrations. Small, but significant fluctuations in ad libitum mix concentration occurred in both of these groups, but the differences appeared to be random rather than systematic. The results of this study indicate that preference for the taste of salt declines progressively toward a new baseline following reductions in sodium intake. These alterations may enhance maintenance of low­sodium diets for the treatment and prevention of hypertension. Further investigation is needed to establish the degree to which long-term com­pliance is contingent upon variation in salt taste preference.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The quality of a drug is determined after establishing its authenticity by testing its purity and quality of the pure substance in the drug and its formulations.Ion selective sensors have become one of the most effective and powerful means for analytical scientists in the determination of drug substances and are playing an increasing role in pharmaceutical analysis.ISEs are cost effective,easy to prepare and can be rapidly manipulated . Potentiometric ion selective sensors have been developed for six drugs namely trimethoprim, ketoconazole, lamivudine, domperidon, nimesulide and Lomefloxacin. The sensors fabricated include both PVC membrane sensor as well as carbon paste sensor. A total of sixteen different sensors have been developed. The response parameters of all the sensors have been studied and the sensors were applied to the determination of the drugs in pharmaceutical formulations and also in real samples like urine.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Polymer supports are efficient reagents,substrates and catalysts and they are extensively used for carrying out reactions at controlled rates.Tailor-made polymer supports are highly versatile which have opened an excellent area of research.Now polymer supported chemistry is being exploited at an amazing rate and it seems to join the routine world of organic synthesis.Polymer supported ligands are found to be efficient complexing agents whose high selectivity enables the analysis and removal of heavy metal ions which are toxic to all the living organisms of land and sea.polymer supported membranes function as ion selective potentiometric sensors which allow the exchange of specific ions among other ions of the same charge.In this investigation three series of polymeric schiff bases and three series of metal complexes have been prepared.An attempt is done to develop optimum conditions for the removal of heavy metal ions using polymeric schiff bases.A novel copper sensor electrode have also been prepared from polymer supported metal complex.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

As the application of polymeric complexes is enormous, there exists a continuing interest in the synthesis and characterization of these complexes. The synthetic and characterization parts are very important in an academic point of view. Further in an application point of view also polymeric ligands/complexes are gaining attention.The thesis is divided in to six chapters, in which the first chapter gives an introduction along with a brief review on polymeric ligands/ complexes. The second chapter explains the different procedure adopted for the whole work along with the details of the reagents/ instruments used. The third chapter gives a report of the detailed study regarding the synthesis and characterization of eighteen complexes. While the fourth chapter is a report of the ion removal studies using three polymeric ligands, the fifth chapter explains the development of a polymeric complex as ion selective electrode material for the fabrication of a CC ion selective electrode. The sixth chapter presents the summary and tables, figures and references are given separately at the end.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The complexation of Cu by sewage sludge-derived dissolved organic matter (SSDOM) is a process by which the environmental significance of the element may become enhanced due to reduced soil sorption and, hence, increased mobility. The work described in this paper used an ion selective electrode procedure to show that SSDOM complexation of Cu was greatest at intermediate pH values because competition between hydrogen ions and Cu for SSDOM binding sites, and between hydroxyl ions and SSDOM as Cu ligands, was lowest at such values. Batch sorption experiments further showed that the process of Cu complexation by SSDOM provided an explanation for enhanced desorption of Cu from the solid phase of a contaminated, organic matter-rich, clay loam soil, and reduced adsorption of Cu onto the solid phase of a sandy loam soil. Complexation of Cu by SSDOM did not affect uptake of Cu by spring barley plants, when compared to free ionic Cu, in a sand-culture pot experiment. However, it did appear to lead to greater biomass yields of the plant; perhaps indicating that the Cu-SSDOM complex had a lower toxicity towards the plant than the free Cu ion.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the last decade, there has been renewed interest in biologically active peptides in fields like allergy, autoimmume diseases and antibiotic therapy. Mast cell degranulating peptides mimic G-protein receptors, showing different activity levels even among homologous peptides. Another important feature is their ability to interact directly with membrane phospholipids, in a fast and concentration-dependent way. The mechanism of action of peptide HR1 on model membranes was investigated comparatively to other mast cell degranulating peptides (Mastoparan, Eumenitin and Anoplin) to evidence the features that modulate their selectivity. Using vesicle leakage, single-channel recordings and zeta-potential measurements, we demonstrated that HR1 preferentially binds to anionic bilayers, accumulates, folds, and at very low concentrations, is able to insert and create membrane spanning ion-selective pores. We discuss the ion selectivity character of the pores based on the neutralization or screening of the peptides charges by the bilayer head group charges or dipoles. (C) 2009 Elsevier Inc. All rights reserved.