750 resultados para Intrasubject repeatability


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Contact lens electrodes (CLEs) are frequently used to register electroretinograms (ERGs) in small animals such as mice or rats. CLEs are expensive to buy or difficult to be produced individually. In addition, CLE`s have been noticed to elicit inconstant results and they carry potential to injure the cornea. Therefore, a new electrode holder was constructed based on the clinically used DTL-electrode and compared to CLEs. Material and methods: ERGs were recorded with both electrode types in nine healthy Brown-Norway rats under scotopic conditions. For low intensity responses a Naka-Rushton function was fitted and the parameters V(max), k and n were analyzed. The a-wave, b-wave and oscillatory potentials were analyzed for brighter flash intensities (1-60 scot cd s/m(2)). Repeatability was assessed for both electrode types in consecutive measurements. Results: The new electrode holder was faster in setting up than the CLE and showed lower standard deviations. No corneal alterations were observed. Slightly higher amplitudes were recorded in most of the measurements with the new electrode holder (except amplitudes induced by 60 cd s/m(2)). A Bland-Altman test showed good agreement between the DTL holder and the CLE (mean difference 35.2 mu V (Holder-CLE)). Pearson`s correlation coefficient for test-retest-reliability was r = 0.783. Conclusions: The DTL holder was superior in handling and caused far less corneal problems than the CLE and produced comparable or better electrophysiological results. The minimal production costs and the possibility of adapting the DTL holder to bigger eyes, such as for dogs or rabbits, offers with broader application prospects. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To propose an electronic method for sensitivity evaluation in leprosy and to compare it to the Semmes-Weinstein monofilaments. Methods:Thirty patients attending the Dermatology outpatient clinic of HCFMRP-USP were consecutively evaluated by both the electronic aesthesiometer and Semmes-Weinstein monofilaments on hand and foot test points. The intraclass correlation coefficient (ICC) was calculated to determine the variability of the electronic measures and the Kappa coefficient was calculated to determine the agreement between methods according to their categories (altered and non-altered tactile sensitivity). Results: The ICC was approximately 1, demonstrating repeatability. The Kappa coefficient showed more than 75 and 63% agreement on the hand and foot points, respectively. The mean agreement between the 2 methods for the 7 points of the right and left hand was 77.14 and 75.71%, respectively. The mean agreement for all 10 points was 74.33 and 63.66% on the right and left foot, respectively. In cases of disagreement the detection of altered tactile sensitivity by the electronic esthesiometer on the right and left foot was 90.91 and 84.25%, respectively, with no detection by the monofilaments. Conclusion: The results suggest that the electronic esthesiometer is a reliable and easy application, capable of evaluating alterations of tactile sensitivity in leprosy patients. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study estimated the population pharmacokinetics of lamotrigine in patients receiving oral lamotrigine therapy with drug concentration monitoring, and determined intersubject and intrasubject variability. A total of 129 patients were analyzed from two clinical sites. Of these, 124 patients provided spare data (198 concentration-time points); nine patients (four from a previous group plus five from the current group) provided rich data (431 points). The population analysis was conducted using P-PHARM (TM) (SIMED Scientific Software, Cedex, France), a nonlinear mixed-effect modeling program. A single exponential elimination model (first-order absorption) with heteroscedastic weighting was used. Apparent clearance (CL/F) and volume of distribution (V/F) were the pharmacokinetic parameters estimated. Covariate analysis was performed to determine which factors explained any of the variability associated with lamotrigine clearance. Population estimates of CL/F and V/F for lamotrigine generated in the final model were 2.14 +/- 0.81 L/h and 78.1 +/- 5.1 L/kg. Intersubject and intrasubject variability for clearance was 38% and 38%, respectively. The covariates of concomitant valproate and phenytoin therapy accounted for 42% of the intersubject variability of clearance. Age, gender, clinic site, and other concomitant antiepileptic drugs did not influence clearance. This study of the population pharmacokinetics of lamotrigine in patients using the drug clinically provides useful data and should lead to better dosage individualization for lamotrigine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: Advances in surface electromyography (sEMG) techniques provide a clear indication that refinement of electrode location relative to innervation zones (IZ) is required in order to optimise the accuracy, relevance and repeatability of the sEMG signals. The aim of this study was to identify the IZ for the sternocleidomastoid and anterior scalene muscles to provide guidelines for electrode positioning for future clinical and research applications. Methods: Eleven volunteer subjects participated in this study. Myoelectric signals were detected from the sternal and clavicular heads of the stemocleidomastoid and the anterior scalene muscles bilaterally using a linear array of 8 electrodes during isometric cervical flexion contractions. The signals were reviewed and the IZ(s) were identified, marked on the subjects' skin and measurements were obtained relative to selected anatomical landmarks. Results: The position of the IZ lay consistently around the mid-point or in the superior portion of the muscles studied. Conclusions: Results suggest that electrodes should be positioned over the lower portion of the muscle and not the mid-point, which has been commonly used in previous studies. Recommendations for sensor placement on these muscles should assist investigators and clinicians to ensure improved validity in future sEMG applications. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new cloud-point extraction and preconcentration method, using a cationic, surfactant, Aliquat-336 (tricaprylyl-methy;ammonium chloride), his-been developed for the determination of cyanobacterial toxins, microcystins, in natural waters. Sodium sulfate was used to induce phase separation at 25 degreesC. The phase behavior of Aliquat-336 with respect to concentration of Na2SO4 was studied. The cloud-point system revealed a very high phase volume ratio compared to other established systems of nonionic, anionic, and cationic surfactants: At pH 6-7, it showed an outstanding selectivity in ahalyte extraction for anionic species. Only MC-LR and MC-YR, which are known to be predominantly anionic, were extracted (with averaged recoveries of 113.9 +/- 9% and 87.1 +/- 7%, respectively). MC-RR, which is likely to be amphoteric at the above pH range, was. not cle tectable in.the extract. Coupled to HPLC/UV separation and detection, the cloud-point extraction method (with 2.5 mM Aliquat-336 and 75 mM Na2SO4 at 25 degreesC) offered detection limits of 150 +/- 7 and 470 +/- 72 pg/mL for MC-LR and MC-YR, respectively, in 25 mL of deionized water. Repeatability of the method was 7.6% for MC-LR and 7.3% for MC-YR: The cloud-point extraction process can be. completed within 10-15 min with no cleanup steps required. Applicability of the new method to the determination of microcystins in real samples was demonstrated using natural surface waters, collected from a local river and a local duck pond spiked with realistic. concentrations of microcystins. Effects of salinity and organic matter (TOC) content in the water sample on the extraction efficiency were also studied.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Most external assessments of cervical range of motion assess the upper and lower cervical regions simultaneously. This study investigated the within and between days reliability of the clinical method used to bias this movement to the upper cervical region, namely measuring rotation of the head and neck in a position of full cervical flexion. Measurements were made using the Fastrak measurement system and were conducted by one operator. Results indicated high levels of within and between days repeatability (range of ICC2,1 values: 0.85-0.95). The ranges of axial rotation to right and left, measured with the neck positioned in full flexion, were approximately 56% and 50%, respectively of total cervical rotation, which relates well to the proportional division of rotation in the upper and lower cervical regions. These results suggest that this method of measuring rotation would be appropriate for use in subject studies where movement dysfunction is present in the upper cervical region, such as those with cervicogenic headache. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and Purpose. This study evaluated an electromyographic technique for the measurement of muscle activity of the deep cervical flexor (DCF) muscles. Electromyographic signals were detected from the DCF, sternocleidomastoid (SCM), and anterior scalene (AS) muscles during performance of the craniocervical flexion (CCF) test, which involves performing 5 stages of increasing craniocervical flexion range of motion-the anatomical action of the DCF muscles. Subjects. Ten volunteers without known pathology or impairment participated in this study. Methods. Root-mean-square (RMS) values were calculated for the DCF, SCM, and AS muscles during performance of the CCF test. Myoelectric signals were recorded from the DCF muscles using bipolar electrodes placed over the posterior oropharyngeal wall. Reliability estimates of normalized RMS values were obtained by evaluating intraclass correlation coefficients and the normalized standard error of the mean (SEM). Results. A linear relationship was evident between the amplitude of DCF muscle activity and the incremental stages of the CCF test (F=239.04, df=36, P<.0001). Normalized SEMs in the range 6.7% to 10.3% were obtained for the normalized RMS values for the DCF muscles, providing evidence of reliability for these variables. Discussion and Conclusion. This approach for obtaining a direct measure of the DCF muscles, which differs from those previously used, may be useful for the examination of these muscles in future electromyographic applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the decline in coronary heart disease in many European countries, the disease remains an enormous public health problem. Although we know a great deal about environmental risk factors for coronary heart disease, a heritable component was recognized a long time ago. The earliest and best known examples of how our genetic constitution may determine cardiovascular risk relate to lipoprotein(a), familial hypercholesterolaemia and apolipoprotein E. In the past 20 years a fair number of polymorphisms assessed singly have shown strong associations with the disease but most are subject to poor repeatability. Twins constitute a compelling natural experiment to establish the genetic contribution to coronary heart disease and its risk factors. GenomEUtwin, a recently funded Framework 5 Programme of the European Community, affords the opportunity of comparing the heritability of risk factors in different European Twin Registries. As an illustration we present the heritabilities of systolic and diastolic blood pressure, based on data from over 4000 twin pairs from six different European countries and Australia. Heritabilities for systolic blood pressure are between 52 and 66% and for diastolic blood pressure between 44 and 66%. There is no evidence of sex differences in heritability estimates and very little to no evidence for a significant contribution of shared family environment. A non-twin based prospective case/cohort study of coronary heart disease and stroke (MORGAM) will allow hypotheses relating to cardiovascular disease, generated in the twin cohorts, to be tested prospectively in adult populations. Twin studies have also contributed to our understanding of the life course hypothesis, and GenomEUtwin has the potential to add to this.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. The purpose of this study was to examine the reliability of stage of change (SOC) measures for moderate-intensity and vigorous physical activity in two separate samples of young adults. Staging measures have focused on vigorous exercise, but current public health guidelines emphasize moderate-intensity activity. Method. For college students in the USA (n = 105) and in Australia (n = 123), SOC was assessed separately on two occasions for moderate-intensity activity and for vigorous activity. Test-retest repeatability was determined, using Cohen's kappa coefficient. Results. In both samples, the reliability scores for the moderate-intensity physical activity staging measure were lower than the scores for the vigorous exercise staging measure. Weighted kappa values for the moderate-intensity staging measure were in the fair to good range for both studies (0.50 and 0.45); for the vigorous staging measure kappa values were excellent and fair to good (0.76 and 0.72). Conclusions. There is a need to standardize and improve methods for staging moderate-intensity activity, given that such measures are used in public health interventions targeting HEPA (health-enhancing physical activity). (C) 2003 American Health Foundation and Elsevier Science (USA). All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O uso do biodiesel como um substituto total ou parcial do diesel de petróleo é significativo, entretanto a sua baixa estabilidade oxidativa é um ponto desfavorável. Portanto o uso de antioxidantes é viável desde que diminuam a velocidade de degradação promovido pela oxidação. Mas a ação de um antioxidante está relacionada com a composição química do biodiesel ao qual é adicionado. Considerando a importância e o crescimento da indústria de biodiesel, a necessidade de utilização de antioxidantes, e a busca por novas fontes como matérias primas, faz-se necessário estudar a eficiência de antioxidantes para o aumento da vida útil do biodiesel, além de avaliar novas culturas com potencial de produção como o pinhão manso (Jatropha curcas L.) e nabo forrageiro (Raphanus sativus L.). O objetivo deste trabalho foi avaliar os antioxidantes BHT (butilhidroxitolueno), PA (ácido pirogálico) e PG (galato de propila), em concentrações de 50, 200, 500, 1000 e 2000 mg/kg, nos biodiesel de pinhão manso, nabo forrageiro e soja, empregando a metodologia PetroOXY, ensaio acelerado de oxidação, para a determinação do seu período de indução. Os biodieseis foram obtidos através de reações de transesterificação, utilizando rota metílica, com rendimentos superiores a 80% e foram caracterizados através de alguns parâmetros físico-químicos. Foi observada a eficiência do uso de antioxidantes no aumento da vida útil do biodiesel. E com o aumento da concentração houve um aumento do período de indução. A eficiência do BHT foi sempre crescente com o aumento da concentração para todos os biodieseis enquanto que para o PG e PA houve uma diminuição da eficiência na maior concentração. A metodologia usada para avaliação da estabilidade oxidativa, PetroOXY, mostrou-se eficaz, de boa repetibilidade e reprodutibilidade, além de ser mais rápida e completa que o método Rancimat. Na concentração mais elevada, 2000 mg/kg, o melhor desempenho foi para o BHT, nas concentrações inferiores a 2000 mg/kg, a melhor eficiência foi para o PA ~ PG, nos três biodieseis estudados, soja, nabo forrageiro e pinhão manso.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

n plant breeding programs that aim to obtain cultivars with nitrogen (N) use efficiency, the focus is on methods of selection and experimental procedures that present low cost, fast response, high repeatability, and can be applied to a large number of cultivars. Thus, the objectives of this study were to classify maize cultivars regarding their use efficiency and response to N in a breeding program, and to validate the methodology with contrasting doses of the nutrient. The experimental design was a randomized block with the treatments arranged in a split-plot scheme with three replicates and five N doses (0, 30, 60, 120 and 200 kg ha-1) in the plots, and six cultivars in subplots. We compared a method examining the efficiency and response (ER) with two contrasting doses of N. After that, the analysis of variance, mean comparison and regression analysis were performed. In conclusion, the method of the use efficiency and response based on two N levels classifies the cultivars in the same way as the regression analysis, and it is appropriate in plant breeding routine. Thus, it is necessary to identify the levels of N required to discriminate maize cultivars in conditions of low and high N availability in plant breeding programs that aim to obtain efficient and responsive cultivars. Moreover, the analysis of the interaction genotype x environment at experiments with contrasting doses is always required, even when the interaction is not significant.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current level of demand by customers in the electronics industry requires the production of parts with an extremely high level of reliability and quality to ensure complete confidence on the end customer. Automatic Optical Inspection (AOI) machines have an important role in the monitoring and detection of errors during the manufacturing process for printed circuit boards. These machines present images of products with probable assembly mistakes to an operator and him decide whether the product has a real defect or if in turn this was an automated false detection. Operator training is an important aspect for obtaining a lower rate of evaluation failure by the operator and consequently a lower rate of actual defects that slip through to the following processes. The Gage R&R methodology for attributes is part of a Six Sigma strategy to examine the repeatability and reproducibility of an evaluation system, thus giving important feedback on the suitability of each operator in classifying defects. This methodology was already applied in several industry sectors and services at different processes, with excellent results in the evaluation of subjective parameters. An application for training operators of AOI machines was developed, in order to be able to check their fitness and improve future evaluation performance. This application will provide a better understanding of the specific training needs for each operator, and also to accompany the evolution of the training program for new components which in turn present additional new difficulties for the operator evaluation. The use of this application will contribute to reduce the number of defects misclassified by the operators that are passed on to the following steps in the productive process. This defect reduction will also contribute to the continuous improvement of the operator evaluation performance, which is seen as a quality management goal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: A case-control study of patients with pneumonia was conducted to investigate whether wheezing diseases could be a risk factor. METHODS: A random sample was taken from a general university hospital in S. Paulo City between March and August 1994 comprising 51 cases of pneumonia paired by age and sex to 51 non-respiratory controls and 51 healthy controls. Data collection was carried out by two senior paediatricians. Diagnoses of pneumonia and presence of wheezing disease were independently established by each paediatrician for both cases and controls. Pneumonia was radiologically confirmed and repeatability of information on wheezing diseases was measured. Logistic regression analysis was used to identify risk factors. RESULTS: Wheezing diseases, interpreted as proxies of asthma, were found to be an important risk factor for pneumonia with an odds ratio of 7.07 (95%CI= 2.34-21.36), when the effects of bedroom crowding (odds ratio = 1.49 per person, 95%CI= 0.95-2.32) and of low family income (odds ratio = 5.59 against high family income, 95%CI= 1.38-22.63) were controlled. The risk of pneumonia attributable to wheezing diseases is tentatively calculated at 51.42%. CONCLUSION: It is concluded that at practice level asthmatics should deserve proper surveillance for infection and that at public health level pneumonia incidence could be reduced if current World Health Organisation's guidelines were reviewed as to include comprehensive care for this illness.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ao nível da segurança de circulação rodoviária e aeroportuária, a aderência entre os pneumáticos e a superfície do pavimento apresenta-se como uma das características superficiais mais importantes dos pavimentos em situações de piso molhado. Mundialmente, tem-se dado relevante importância a este facto, levando a que nas últimas décadas e anos, se tenham estudado diversos índices e equipamentos de medição do coeficiente de atrito de um dado pavimento aquando da presença de água. O objectivo da presente dissertação é o de aprofundar o conhecimento sobre a medição do coeficiente de atrito da superfície dos pavimentos de infraestruturas rodoviárias e aeroportuárias, com a particular incidência no estudo do equipamento GripTester. O trabalho realizado consistiu principalmente na análise de valores do coeficiente de atrito da camada de desgaste medidos no pavimento de um aeródromo, por três equipamentos GripTester, através de um ensaio de comparação interlaboratorial que foi organizado especificamente no âmbito desta dissertação. O trabalho desenvolvido permitiu concluir que foi importante desenvolver este estudo comparativo. Com efeito, a análise dos resultados do ensaio de comparação interlaboratorial mostrou que há diferenças no desempenho dos equipamentos participantes, que interessa aprofundar em estudos comparativos futuros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine the precision and agreement of the hemoglobin (Hb) measurements in capillary and venous blood samples by the HemoCue® and an automated counter. Hb was determined by both equipaments in blood samples of 29 pregnant women. The HemoCue® showed low repeatability of Hb measurements in duplicate in capillary (CR=0.53 g/dL, CV=13.6%) and venous blood (CR=0.53 g/dL, CV=13.6%). Hb measurements in capillary blood were higher than those in venous blood (12.4 and 11.7 g/dL, respectively; p<0.05). There was high agreement between Hb in capillary blood by the HemoCue® and in venous blood by the counter (r icc=0.86; p<0.01), and also between the diagnosis of anemia by both equipments (k=0.81; p<0.01). The HemoCue® seems to be more appropriate for capillary blood and require training of the measurers.