935 resultados para Intraocular lens power


Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on the latter is very low, and some concerns still remain about its long-term safety. The present article reviews the published literature on the outcomes after PRL implantation in order to provide a general overview and evaluate its real potential as a surgical refractive option.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Cataract surgery is a technique described since recorded history, yet it has greatly evolved only in the latter half of the past century. The development of the intraocular lens and phacoemulsification as a technique for cataract removal could be considered as the two most significant strides that have been made in this surgical field. This review takes a comprehensive look at all aspects of cataract surgery, starting from patient selection through the process of consent, anaesthesia, biometry, lens power calculation, refractive targeting, phacoemulsification, choice of intraocular lens and management of complications, such as posterior capsular opacification, as well as future developments. As the most common ophthalmic surgery and with the expanding range of intraocular lens options, optometrists have an important and growing role in managing patients with cataract.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Background: The aim was to investigate the effect on the measured amplitude of accommodation and repeatability of using the minus lens technique with the target at distance or near. Methods: Forty-three students (average age: 21.17 ± 1.50 years, 35 female) had their amplitude of accommodation measured with minus lenses on top of their distance correction in a trial frame with the target at far (6.0m) or near (0.4m). The minus lens power was gradually added with steps of 0.25D. Measurements were taken on two occasions at each distance, which were separated by a time interval of at least 24 hours. Results: The measured amplitude at six metres was significantly lower than that with the target at 40cm, by 1.56 ± 1.17D (p < 0.001) and this varied between individuals (r = 0.716, intraclass correlation coefficient = 0.439). With either target distance, repeated measurement was highly correlated (r > 0.9) but the agreement was better at 6.0m (±0.74D) than at 40cm (± 0.92D). Conclusion: The measurements of the amplitude of accommodation with the minus lens technique using targets at far or near are not comparable and the difference between the target distances may provide clinically relevant information. © 2013 Optometrists Association Australia.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The tear film, cornea and lens dictate the refractive power of the eye and the retinal image quality is principally defined by diffraction, whole eye wavefront error, scatter, and chromatic aberration. Diffraction and wave aberration are fundamentally pupil diameter dependent; however scatter can be induced by refractive surgery and in the normal ageing eye becomes an increasingly important factor defining retinal image quality. The component of visual quality most affected by the tear film, refractive surgery and multifocal contact and intraocular lenses is the wave aberration of the eye. This body of work demonstrates the effects of each of these anomalies on the visual quality of the eye. When assessing normal or borderline self-diagnosed dry eye subjects using aberrometry, combining lubricating eye drops and spray does not offer any benefit over individual products. However, subjects perceive a difference in comfort for all interventions after one hour. Total higher order aberrations increase after laser assisted sub-epithelial keratectomy performed using a solid-state laser on myopes, but this causes no significant decrease in contrast sensitivity or increase in glare disability. Mean sensitivity and reliability indices for perimetry were comparable to pre-surgery results. Multifocal contact lenses and intraocular lenses are designed to maximise vision when the patient is binocular, so any evaluation of the eyes individually is confounded by reduced individual visual acuity and visual quality. Different designs of aspheric multifocal contact lenses do not provide the same level of visual quality. Multifocal contact lenses adversely affect mean deviation values for perimetry and this should be considered when screening individuals with multifocal contact or intraocular lenses. Photographic image quality obtained through a multifocal contact or intraocular lens appears to be unchanged. Future work should evaluate the effect of these anomalies in combination; with the aim of providing the best visual quality possible and supplying normative data for screening purposes.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose To compare measurements taken using a swept-source optical coherence tomography-based optical biometer (IOLmaster 700) and an optical low-coherence reflectometry biometer (Lenstar 900), and to determine the clinical impacts of differences in their measurements on intraocular lens (IOL) power predictions. Methods Eighty eyes of 80 patients scheduled to undergo cataract surgery were examined with both biometers. The measurements made using each device were axial length (AL), central corneal thickness (CCT), aqueous depth (AQD), lens thickness (LT), mean keratometry (MK), white-to-white distance (WTW), and pupil diameter (PD). Holladay 2 and SRK/T formulas were used to calculate IOL power. Differences in measurement between the two biometers were determined using the paired t-test. Agreement was assessed through intraclass correlation coefficients (ICC) and Bland–Altman plots. Results Mean patient age was 76.3±6.8 years (range 59–89). Using the Lenstar, AL and PD could not be measured in 12.5 and 5.25% of eyes, respectively, while IOLMaster 700 took all measurements in all eyes. The variables CCT, AQD, LT, and MK varied significantly between the two biometers. According to ICCs, correlation between measurements made with both devices was excellent except for WTW and PD. Using the SRK/T formula, IOL power prediction based on the data from the two devices were statistically different, but differences were not clinically significant. Conclusions No clinically relevant differences were detected between the biometers in terms of their measurements and IOL power predictions. Using the IOLMaster 700, it was easier to obtain biometric measurements in eyes with less transparent ocular media or longer AL.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose To develop and use equations of spectacle magnification when the limiting stop is either the entrance pupil of the eye or an artificial pupil in front of a lens. Methods Spectacle magnification was determined for ophthalmic lenses in air and for water environments. The reference was the retinal image for an uncorrected eye in air with a natural pupil. Results When an artificial pupil is placed in front of lenses, spectacle magnification is hardly affected by lens power, unlike the usual situation where the natural pupil is used. The water environment provides interesting influences in which spectacle magnification is highly sensitive to the distance between the cornea and eye entrance pupil. In water, retinal images are approximately 18% bigger than in air. Wearing air-filled goggles in water increases retinal image size by about 13% compared with that when they are not worn. Conclusions The equations extend earlier understanding of spectacle magnification and should be useful for those wishing to determine magnification of ophthalmic lens systems when artificial pupils and environments such as water are used.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose.: To develop three-surface paraxial schematic eyes with different ages and sexes based on data for 7- and 14-year-old Chinese children from the Anyang Childhood Eye Study. Methods.: Six sets of paraxial schematic eyes, including 7-year-old eyes, 7-year-old male eyes, 7-year-old female eyes, 14-year-old eyes, 14-year-old male eyes, and 14-year-old female eyes, were developed. Both refraction-dependent and emmetropic eye models were developed, with the former using linear dependence of ocular parameters on refraction. Results.: A total of 2059 grade 1 children (boys 58%) and 1536 grade 8 children (boys 49%) were included, with mean age of 7.1 ± 0.4 and 13.7 ± 0.5 years, respectively. Changes in these schematic eyes with aging are increased anterior chamber depth, decreased lens thickness, increased vitreous chamber depth, increased axial length, and decreased lens equivalent power. Male schematic eyes have deeper anterior chamber depth, longer vitreous chamber depth, longer axial length, and lower lens equivalent power than female schematic eyes. Changes in the schematic eyes with positive increase in refraction are decreased anterior chamber depth, increased lens thickness, decreased vitreous chamber depth, decreased axial length, increased corneal radius of curvature, and increased lens power. In general, the emmetropic schematic eyes have biometric parameters similar to those arising from regression fits for the refraction-dependent schematic eyes. Conclusions.: The paraxial schematic eyes of Chinese children may be useful for myopia research and for facilitating comparison with other children with the same or different racial backgrounds and living in different places.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: A full-thickness macular hole (FTMH) is a common retinal condition associated with impaired vision. Randomised controlled trials (RCTs) have demonstrated that surgery, by means of pars plana vitrectomy and post-operative intraocular tamponade with gas, is effective for stage 2, 3 and 4 FTMH. Internal limiting membrane (ILM) peeling has been introduced as an additional surgical manoeuvre to increase the success of the surgery; i.e. increase rates of hole closure and visual improvement. However, little robust evidence exists supporting the superiority of ILM peeling compared with no-peeling techniques. The purpose of FILMS (Full-thickness macular hole and Internal Limiting Membrane peeling Study) is to determine whether ILM peeling improves the visual function, the anatomical closure of FTMH, and the quality of life of patients affected by this disorder, and the cost-effectiveness of the surgery. Methods/Design: Patients with stage 2-3 idiopathic FTMH of less or equal than 18 months duration (based on symptoms reported by the participant) and with a visual acuity = 20/40 in the study eye will be enrolled in this FILMS from eight sites across the UK and Ireland. Participants will be randomised to receive combined cataract surgery (phacoemulsification and intraocular lens implantation) and pars plana vitrectomy with postoperative intraocular tamponade with gas, with or without ILM peeling. The primary outcome is distance visual acuity at 6 months. Secondary outcomes include distance visual acuity at 3 and 24 months, near visual acuity at 3, 6, and 24 months, contrast sensitivity at 6 months, reading speed at 6 months, anatomical closure of the macular hole at each time point (1, 3, 6, and 24 months), health related quality of life (HRQOL) at six months, costs to the health service and the participant, incremental costs per quality adjusted life year (QALY) and adverse events. Discussion: FILMS will provide high quality evidence onthe role of ILM peeling in FTMH surgery. © 2008 Lois et al; licensee BioMed Central Ltd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pseudophakic retinal detachment is a rare, but potentially serious, complication of cataract surgery. The incidence of pseudophakic retinal detachment following current surgical techniques of cataract extraction, including extracapsular cataract extraction by nuclear expression and phacoemulsification, is lower than that found after intracapsular cataract extraction. The risk of pseudophakic retinal detachment appears to be increased in myopic patients, in those patients in whom vitreous loss had occurred at the time of cataract surgery, and in patients undergoing Nd:YAG posterior capsulotomy. Most cases present to the clinician when the macula is already detached and the central vision is affected. When evaluating patients with pseudophakic retinal detachment, the fundal view is often impaired by anterior or posterior capsular opacification, reflections related to the intraocular lens, or poor mydriasis. Scleral buckling, pneumatic retinopexy, and primary pars plana vitrectomy, with or without combined scleral buckling, are the surgical techniques used to treat pseudophakic retinal detachment. Anatomical success rates are high after vitreo-retinal surgery for pseudophakic retinal detachment, although a smaller proportion of patients recover good vision following surgery. © 2003 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE. To describe a new model of posterior capsule opacification (PCO) in rodents METHODS. An extracapsular lens extraction (ECLE), by continuous curvilinear capsulorrhexis and hydrodissection, was performed in 42 consecutive Brown Norway rats. Animals were killed at 0, 6, and 24 hours and 3, 7, and 14 days after surgery. Eyes were enucleated and processed for light microscopy and immunohistochemistry. RESULTS. In 34 (81%) of the animals the operated eye appeared well healed before death, with a clear cornea and a well-formed anterior chamber. In eight (19%) there was no view of anterior segment structures because of hyphema, fibrin, or corneal opacification. PCO was clinically evident 3 days after ECLE and was present in all animals at 2 weeks. Immediately after ECLE, lens epithelial cells (LECs) were present in the inner surface of the anterior capsule and lens bow. Twenty-four hours after surgery, LECs started to migrate toward the center of the posterior capsule. At 3 days, multilayered LECs, some spindle shaped, were present throughout the lens capsule. Capsular wrinkling was apparent. Lens fibers and Soemmering's ring were observed in all animals 14 days after surgery, indicating some degree of cellular differentiation. Activated macrophages were present in greater numbers at 3 and 14 days after surgery (P <0.05), when proliferation and migration of LECs appeared to be greatest, and lens fiber differentiation was evident, respectively. CONCLUSIONS. In rodents PCO occurs after ECLE and is associated with low-grade inflammation, mostly of mononuclear macrophages. Although no intraocular lens implantation was performed, this model appears to be valuable for studying the sequence of events that leads to PCO after cataract surgery and the extracellular matrix cues that promote lens fiber differentiation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To identify changing trends in indications for penetrating keratoplasty and associated surgical procedures. Methods. Review of charts from all patients who underwent penetrating keratoplasty at Wills Eye Hospital from January 1, 1989 through December 31, 1995. Results. A total of 2,442 corneal transplants were performed in 2,186 patients. The leading indication for penetrating keratoplasty was pseudophakic corneal edema, accounting for 634 cases (26.0%); 54.7% of them were associated with anterior chamber intraocular lenses, 36.4% with posterior chamber intraocular lenses, and 3.1% with iris-fixated intraocular lenses. Regraft (17.8%), Fuchs' dystrophy (15.7%), and keratoconus (13.2%) followed pseudophakic corneal edema in frequency. Cataract extraction, with or without intraocular lens implantation, was combined with penetrating keratoplasty in 439 cases of 1,264 phakic eyes (34.7%). Intraocular lens exchange was performed in 285 of the 634 cases of pseudophakic cornea edema (44.9%). Conclusion. Pseudophakic corneal edema was the leading indication for penetrating keratoplasty, with an increasing number of cases associated with posterior chamber intraocular lenses during the study period (p = 0.001). The number of regrafts steadily increased between 1989 and 1995 (p = 0.001), being the second most common indication for corneal transplantation since 1992.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A 42-year-old man has been under long-term follow-up since he was a child for congenital glaucoma and buphthalmos in both eyes. His left eye best corrected visual acuity (BCVA) was counting fingers, due to end-stage glaucoma. He was on maximal medical therapy with an intraocular pressure (IOP) maintained at mid to low twenties. His right eye, the only seeing eye, had a BCVA of 6/9. This eye had undergone multiple glaucoma laser and surgical procedures, including an initial first Molteno drainage device inserted superonasally that failed in April 2003 due to fibrotic membrane over the tube opening. As a result, he subsequently had a second Molteno drainage device inserted inferotemporally. To further maximize his vision he had an uncomplicated cataract extraction and intraocular lens implant in December 2004, after which he developed postoperative cystoid macular edema and corneal endothelial failure. He underwent a penetrating keratoplasty in the right eye thereafter in March 2007. After approximately a year, the second Molteno device developed drainage tube retraction, which was managed surgically to maintain optimum IOP in the right eye. His right eye vision to date is maintained at 6/12. © 2011 Mustafa and Azuara-Blanco.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate and compare the outcome of functioning filtration surgery followed by cataract surgery with posterior intraocular lens implantation by both phacoemulsification and extracapsular cataract extraction (ECCE) techniques in glaucomatous eyes. PATIENTS AND METHODS: We retrospectively evaluated the clinical course of 77 eyes (68 patients) that after successful trabeculectomy, underwent cataract surgery by either phacoemulsification or ECCE techniques. We determined the frequency of partial and absolute failure following cataract surgery by either phacoemulsification or ECCE in eyes with functioning trabeculectomies. Partial failure of intraocular pressure (IOP), control after cataract extraction was defined as the need for an increased number of antiglaucoma medications or argon laser trabeculoplasty to maintain IOP =21mm Hg. Complete failure of IOP control after cataract surgery was defined as an IOP >21 mm Hg on at least two consecutive measurements one or more weeks apart or the performance of additional filtration surgery. Failure rates were calculated using the Kaplan-Meier actuarial method. Failure rates between phacoemulsification and ECCE subgroups were compared using the log rank test. RESULTS: The probability of partial failure by the third postoperative year after cataract surgery was 39.5% in the phacoemulsification subgroup and 37.3% in the ECCE subgroup. This small difference is not statistically significant (P = 0.48). The probability of complete failure by the fourth postoperative year after cataract surgery was 12.0% in the phacoemulsification subgroup and 12.5% in the ECCE subgroup. This difference is also not statistically significant (P = 0.77). At the 6-month follow-up visit, visual acuity of both groups improved one or more lines in 87.0% of patients, and worsened one or more lines in 3.9% of patients. Sixty-one percent achieved visual acuity of 20/40 or better. The most frequent complication was posterior capsular opacification requiring laser capsulotomy that occurred in 31.2% of patients. CONCLUSION: Cataract extraction by either phacoemulsification or ECCE following trabeculectomy surgery may be associated with a partial loss of the previously functioning filter and the need for more antiglaucoma medications to control IOP.