806 resultados para Intraocular Lens Implantation


Relevância:

90.00% 90.00%

Publicador:

Resumo:

OBJECTIVE: This study sought to compare the effects and outcomes of two ophthalmic viscosurgical devices, 1.6% hyaluronic acid/4.0% chondroitin sulfate and 2.0% hydroxypropylmethylcellulose, during phacoemulsification. METHODS: This prospective, randomized clinical trial comprised 78 eyes (39 patients) that received phacoemulsification performed by the same surgeon using a standardized technique. Patients were randomly assigned to receive either 1.6% hyaluronic acid/4.0% chondroitin sulfate or 2.0% hydroxypropylmethylcellulose on the first eye. The other eye was treated later and received the other viscoelastic agent. Preoperative and postoperative examinations (5, 24 and 48 hours; 7 and 14 days; 3 and 6 months) included measurements of the total volume of the ophthalmic viscosurgical device, ultrasound and washout times to completely remove the ophthalmic viscosurgical device, intraocular pressure, central corneal thickness and best-corrected visual acuity. The corneal endothelial cell count was measured at baseline and at six months postoperatively. ClinicalTrials.gov: NCT01387620. RESULTS: There were no statistically significant differences between groups in terms of cataract density or ultrasound time. However, it took longer to remove 2.0% hydroxypropylmethylcellulose than 1.6% hyaluronic acid/ 4.0% chondroitin sulfate, and the amount of viscoelastic material used was greater in the 2.0% hydroxypropylmethylcellulose group. In addition, the best-corrected visual acuity was significantly better in the hyaluronic acid/ chondroitin sulfate group, but this preferable outcome was only observed at 24 hours after the operation. There were no statistically significant differences between the two ophthalmic viscosurgical devices regarding the central corneal thickness or intraocular pressure measurements at any point in time. The corneal endothelial cell count was significantly higher in the hyaluronic acid/chondroitin sulfate group. CONCLUSION: The ophthalmic viscosurgical device consisting of 1.6% hyaluronic acid/4.0% chondroitin sulfate was more efficient during phacoemulsification and was easier to remove after IOL implantation than 2.0% hydroxypropylmethylcellulose. In addition, the corneal endothelial cell count was significantly higher following the use of hyaluronic acid/chondroitin sulfate than with hydroxypropylmethylcellulose, which promoted an improved level of corneal endothelium protection.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The precipitation patterns and characteristics of calcium phosphate (CaP) phases deposited on HEMA-based hydrogels upon incubation in simulated body fluid (SBF-2) containing a protein (human serum albumin) have been investigated in relation to the calcification in an organic-free medium (SBF-1) and to that occurring after subcutaneous implantation in rats. In SBF-2, the deposits occurred exclusively as a peripheral layer on the surface of the hydrogels and consisted mainly of precipitated hydroxyapatite, a species deficient in calcium and hydroxyl ions, similarly to the deposits formed on the implanted hydrogels, where the deposited layer was thicker. In SBF-1, the deposits were mainly of brushite type. There was no evidence that albumin penetrated the interstices of hydrogels. As the X-ray diffraction patterns of the CaP deposits generated in SBF-2 showed a similar nature with those formed on the implanted hydrogel, it was concluded that the calcification in SBF-2 can mimic to a reliable extent the calcification process taking place in a biological environment.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Purpose: Evaluating the impact of splitting toric power on patient tolerance to misorientation such as with intraocular lens rotation. Setting: University vision clinic. Methods: Healthy, non astigmats had +1.50D astigmatism induced with spectacle lenses at 90°, 135°, 180° and +3.00D at 90°. Two correcting cylindrical lenses of the opposite sign and half the power each were subsequently added to the trial frame misaligned by 0°, 5° or 10° in a random order and misorientated from the initial axis in a clockwise direction by up to 15° in 5° steps. A second group of adapted astigmats with between 1.00 and 3.00DC had their astigmatism corrected with two toric spectacle lenses of half the power separated by 0°, 5° or 10° and misorientated from the initial axis in both directions by up to 15° in 5° steps. Distance, high contrast visual acuity was measured using a computerised test chart at each lens misalignment and misorientation. Results: Misorientation of the split toric lenses caused a statistically significant drop in visual acuity (F= 70.341; p< 0.001). Comparatively better acuities were observed around 180°, as anticipated (F= 3.775; p= 0.035). Misaligning the split toric power produced no benefit in visual acuity retention with axis misorientation when subjects had astigmatism induced with a low (F= 2.190, p= 0.129) or high cylinder (F= 0.491, p= 0.617) or in the adapted astigmats (F= 0.120, p= 0.887). Conclusion: Misalignment of toric lens power split across the front and back lens surfaces had no beneficial effect on distance visual acuity, but also no negative effect. © 2013 British Contact Lens Association.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

As technology and medical devices improve, there is much interest in when and how astigmatism should be corrected with refractive surgery. Astigmatism can be corrected by most forms of refractive surgery, such as using excimer lasers algorithms to ablate the cornea to compensate for the magnitude of refractive error in different meridians. Correction of astigmatism at the time of cataract surgery is well developed and can be achieved through incision placement, relaxing incisions and toric intraocular lens (IOL) implantation. This was less of an issue in the past when there was a lower expectation to be spectacle independent after cataract surgery, in which case the residual refractive error, including astigmatism, could be compensated for with spectacle lenses. The issue of whether presurgical astigmatism should be corrected can be considered separately depending on whether a patient has residual accommodation, and the type of refractive surgery under consideration. We have previously reported on the visual impact of full correction of astigmatism, rather than just correcting the mean spherical equivalent. Correction of astigmatism as low as 1.00 dioptres significantly improves objective and subjective measures of functional vision in prepresbyopes at distance and near.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PURPOSE: To assess the visual performance and subjective experience of eyes implanted with a new bi-aspheric, segmented, multifocal intraocular lens: the Mplus X (Topcon Europe Medical, Capelle aan den IJssel, Netherlands). METHODS: Seventeen patients (mean age: 64.0 ± 12.8 years) had binocular implantation (34 eyes) with the Mplus X. Three months after the implantation, assessment was made of: manifest refraction; uncorrected and corrected distance visual acuity; uncorrected and distance corrected near visual acuity; defocus curves in photopic conditions; contrast sensitivity; halometry as an objective measure of glare; and patient satisfaction with unaided near vision using the Near Acuity Visual Questionnaire. RESULTS: Mean residual manifest refraction was -0.13 ± 0.51 diopters (D). Twenty-five eyes (74%) were within a mean spherical equivalent of ±0.50 D. Mean uncorrected distance visual acuity was +0.10 ± 0.12 logMAR monocularly and 0.02 ± 0.09 logMAR binocularly. Thirty-two eyes (94%) could read 0.3 or better without any reading correction and all patients could read 0.3 or better with a reading correction. Mean monocular uncorrected near visual acuity was 0.18 ± 0.16 logMAR, improving to 0.15 ± 0.15 logMAR with distance correction. Mean binocular uncorrected near visual acuity was 0.11 ± 0.11 logMAR, improving to 0.09 ± 0.12 logMAR with distance correction. Mean binocular contrast sensitivity was 1.75 ± 0.14 log units at 3 cycles per degree, 1.88 ± 0.20 log units at 6 cycles per degree, 1.66 ± 0.19 log units at 12 cycles per degree, and 1.11 ± 0.20 log units at 18 cycles per degree. Mean binocular and monocular halometry showed a glare profile of less than 1° of debilitating light scatter. Mean Near Acuity Visual Questionnaire Rasch score (0 = no difficulty, 100 = extreme difficulty) for satisfaction for near vision was 20.43 ± 14.64 log-odd units. CONCLUSIONS: The Mplus X provides a good visual outcome at distance and near with minimal dysphotopsia. Patients were very satisfied with their uncorrected near vision. © SLACK Incorporated.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background and Aims: Submucosal injection of a viscoelastic solution prolongs submucosal lift, thus, facilitating endoscopic mucosal resection. Our objective was to assess the safety and clinical effectiveness of 0.4% hydroxypropyl methylcellulose (HPMC) as a submucosal injectant for endoscopic mucosal resection. Patients and Methods: A prospective, open-label, multicenter, phase 2 study was conducted at 2 academic institutions in Brazil. Eligible participants included patients with early gastrointestinal tumors larger than 10 mm. Outcomes evaluated included complete resection rates, volume of HPMC injected, duration of the submucosal cushion as assessed visually, histology of the resected leisons, and complication rates. Results: Over a 12-month period, 36 eligible patients with superficial neoplastic lesions (stomach 14, colon 11, rectum 5, esophagus 3, duodenum 3) were prospectively enrolled in the study. The mean size of the resected specimen was 20.4 mm (10 to 60 mm). The mean volume of 0.4% HPMC injected was 10.7 mL (range 4 to 35 mL). The mean duration of the submucosal fluid cushion was 27 minutes (range 9 to 70 min). Complete resection was successfully completed in 89%. Five patients (14%) developed immediate bleeding requiring endoclip and APC application. Esophageal perforation occurred in 1 patient requiring surgical intervention. There were no local or systemic adverse events related to HPMC use over the follow-up period (mean 2.2 mo). Conclusion: HPMC solution (0.4%) provides an effective submucosal fluid cushion and is safe for endoscopic resection of early gastrointestinal neoplastic lesions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objective To report the biometric values and ultrasonographic aspects of the normal eye of the Striped owl (Rhinoptynx clamator). Sample population Twenty-seven healthy, free-living, adult Striped owls from the Ecological Park of Tiete Veterinary Ambulatory (Sao Paulo, Brazil). Procedures Both eyes of all owls underwent B-mode ultrasonographic examination and biometry was performed for lens axial length (WL), depth of the anterior (AC) and vitreous (VC) chambers, axial length of the globe (LB) and the pecten oculi (LP) of both eyes, using a 12 MHz probe. The owls were manually restrained without sedation and the eyes were topically anesthetized. Results Biometric and statistical findings were as follows: in the left eye, the means and standard deviations were: LB = 23.76 +/- 0.92 mm, WL = 7.79 +/- 0.27 mm, AC = 4.27 +/- 0.47 mm, VC = 11.36 +/- 0.29 mm and LP = 5.69 +/- 0.50 mm; in the right eye, the values were: LB = 24.25 +/- 0.79 mm, WL = 8.03 +/- 0.40 mm, AC = 4.56 +/- 0.52 mm, VC = 11.40 +/- 0.25 mm, and LP = 5.68 +/- 0.41 mm. No significant differences were found between left and right eyes measurements of LB, WL, AC, VC, and LP dimensions. Conclusions Ocular ultrasound aspects and biometric values of the Striped owl are reported. The study`s results provide means for various ocular measurements. The ultrasound is an easy and safe exam to be performed in the Striped owl`s eyes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To assess the usefulness of electron microscopy of the aqueous cells when confronted with the clinical association of rhegmatogenous retinal detachment after trauma, high intraocular pressure (IOP) and aqueous cells. METHOD: We report a clinical history of a 50-years-old man who had ocular trauma with perforation in 1944, intraocular lens for traumatic cataract in 1988, Yag capsulotomy in 1993 and retinal detachment with oral dialysis, high IOP and aqueous cells in anterior chamber in 1995. During the surgical therapy we performed an anterior chamber puncture to analyse the aqueous cells. An electron microscopic study was performed on 0.2 ml of aqueous humor mixed in the same volume of 2.5% glutaraldehyde and fixed with 1% osmium acid. RESULTS: Electron microscopic ultrastructural study of the aqueous cells showed numerous photoreceptor outer segments, some of them appearing degenerated. CONCLUSION: The combination of rhegmatogenous retinal detachment with tears near the ora serrata, high IOP and aqueous cells in the anterior chamber should lead the physician to do an anterior chamber puncture and analyse the aqueous cells structure. The combination of those three clinical signs associated with the photoreceptor outer segments in the anterior chamber allowed to diagnose the Schwartz-Matsuo syndrome.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Objetivo: Avaliar a existência de contaminação da câmara anterior durante a facectomia por facoemulsificação com implante de lente intra-ocular. Método: Foi realizado estudo prospectivo, avaliando-se 30 pacientes submetidos a facectomia por facoemulsificação com implante de lente intra-ocular, colhendo-se duas amostras de humor aquoso, uma obtida no início e outra no final da cirurgia. As amostras foram semeadas em meio de cultura para germes aeróbios, anaeróbios e fungos. Resultado: Todas as amostras avaliadas resultaram negativas. Conclusão: A contaminação da câmara anterior na cirurgia de facoemulsificação com implante de lente intra-ocular, usando os cuidados necessários, é infreqüente.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A catarata, especialmente na espécie canina, é uma doença oftálmica importante. Seu tratamento é eminentemente cirúrgico, mas a perda do cristalino resulta em alta hipermetropia, e a visão fica comprometida. A correção pode ser feita com a utilização de lente intra-ocular (LIO). Este estudo teve por objetivo colher dados que pudessem fornecer subsídios métricos para a produção de LIOs a serem aplicadas em cães facectomizados, visando a restauração de visão adequada nos animais acometidos por catarata. Foram selecionados 120 cães de ambos os sexos, sadios ao exame clínico e sem evidência de doença ocular ao exame oftálmico de rotina. Foram realizados estudos ceratométrico e biométrico, pela ultra-sonografia modo-A. Uma fórmula específica foi utilizada para a determinação do poder dióptrico de uma LIO utilizada para substituir o cristalino extraído. O poder dióptrico da LIO foi correlacionado com o peso e o sexo dos animais, e entre os olhos direito e esquerdo. Baseado nestas correlações, concluiu-se que o poder dióptrico adequado para uma LIO a ser implantada em um cão facectomizado é influenciado principalmente pelo peso do animal, apesar de apresentar discretas diferenças quando comparado entre os olhos direito e esquerdo e entre machos e fêmeas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Foram utilizados 20 cães de raças e idades variadas, machos e fêmeas, portadores de catarata e não diabéticos, os quais foram submetidos ao exame oftálmico. Posteriormente, realizaram-se mensurações oculares empregando-se um ecobiômetro ultra-sônico (ultra-sonografia modo-A) para o cálculo do poder dióptrico da lente intra-ocular por meio da fórmula SRK/T. O comprimento axial médio foi de 19,94±1,12mm. Todos os animais foram submetidos à facoemulsificação extracapsular. A lente calculada foi implantada no transoperatório da cirurgia de catarata, obtendo-se média de 37,33±3,05D. A avaliação pós-cirúrgica do erro refracional aos 60 dias de pós-operatório, pela retinoscopia, com a utilização da esquiascopia, foi de 5,57±1,59D. A fórmula SRK/T não ofereceu bons resultados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)