992 resultados para Instrument landing systems.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Progress is reported in the development of a new synthesis method for the design of filters and coatings for use in spaceborne infrared optics. This method uses the Golden Section optimization routine to make a search, using designated dielectric thin film combinations, for the coating design which fulfills the required spectral requirements. The final design is that which uses the least number of layers for the given thin film materials in the starting design. This synthesis method has successfully been used to design broadband anti-reflection coatings on infrared substrates. The 6 micrometers to 18 micrometers anti-reflection coating for the germanium optics of the HIRDLS instrument, to be flown on the NASA EOS-Chem satellite, is given as an example. By correctly defining the target function to describe any specific type of filter in the optimization part of the method, this synthesis method may be used to design general filters for use in spaceborne infrared optics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction. Feature usage is a pre-requisite to realising the benefits of investments in feature rich systems. We propose that conceptualising the dependent variable 'system use' as 'level of use' and specifying it as a formative construct has greater value for measuring the post-adoption use of feature rich systems. We then validate the content of the construct as a first step in developing a research instrument to measure it. The context of our study is the post-adoption use of electronic medical records (EMR) by primary care physicians. Method. Initially, a literature review of the empirical context defines the scope based on prior studies. Having identified core features from the literature, they are further refined with the help of experts in a consensus seeking process that follows the Delphi technique. Results.The methodology was successfully applied to EMRs, which were selected as an example of feature rich systems. A review of EMR usage and regulatory standards provided the feature input for the first round of the Delphi process. A panel of experts then reached consensus after four rounds, identifying ten task-based features that would be indicators of level of use. Conclusions. To study why some users deploy more advanced features than others, theories of post-adoption require a rich formative dependent variable that measures level of use. We have demonstrated that a context sensitive literature review followed by refinement through a consensus seeking process is a suitable methodology to validate the content of this dependent variable. This is the first step of instrument development prior to statistical confirmation with a larger sample.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this article, the prevailing official view of supervision as a regulatory instrument is examined as it applies to the social services sector in Sweden. The study is based on a comparison of the views expressed on the design of supervision as a regulatory instrument by two government commissions, the Supervision Commission and the Commission on Supervision within the Social Services (UTIS), and on the positions taken by the Government regarding the definitions of the concept of supervision proposed by these commissions. The view of supervision as a regulatory instrument expressed in these policy documents is analysed with the help of a theoretical framework describing the components, their functions and the governance characteristics of control systems. In the framework separate interrelated characteristics of the components are identified and summarized into two models of control systems. The analysis shows that supervision in the Swedish social services sector can be described in terms of both a disciplinary and non-disciplinary system. By its system theoretical basis and the identification of interrelated characteristics the study contributes to a broadened understanding of the construction and functions of supervision as a regulatory instrument and of how supervision within the Swedish social sector is meant to be designed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Use of geographical information systems (GIS) in inland fisheries has hitherto been essentially restricted to site evaluation for aquaculture development and assessment of limnological changes in time and space in individual water bodies. The present GIS study was conducted on the land-use pattern of the catchments of nine reservoirs in Sri Lanka, for which detailed fishery data, viz. yield, fishing intensity, landing size of major constituent species, together with selected limnological data such as conductivity and chlorophyll-a, were available. Potential statistical relationships (linear, curvilinear, exponential and second-order polynomial) of fish yield (FY, in kg ha−1 yr−1) to different land-use patterns, such as forest cover (FC, in km2) and shrub-land (SL, in km2), either singly, or in combination, and/or the ratio of each land type to reservoir area (RA in km2) and reservoir capacity (RC in km3), were explored. Highly significant relationships were evident between FY to the ratio of SL and/or FC+SL to RA and/or RC. Similarly, the above land-use types to RA and RC ratios were significantly related to limnological features of the reservoirs. The relationships of FY to various parameters obtained in this study were much better correlated than those relationships of FY to limnological and biological parameters used in yield prediction in tropical and temperate lacustrine waters previously.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

One of the major challenges of MIS activities is the difficulty in measuring the effectiveness of delivered systems. The principal purpose of my research is to explore this field in order to develop an instrument by which to measure such effectiveness. Conceptualisation of Information System (IS) Effectiveness has been substantially framed by DeLone and McLean's (1992) Success; Model. But with the innovation in Information Technology (IT) over the past decade, and the constant pressure in IT to improve performance, there is merit in undertaking a fresh appraisal of the issue. This study built on the model of IS Success developed by DeLone and MeLean, but was broadened to include related research from the domains of IS, Management and Marketing. This analysis found that an effective IS function is built on three pillars: the systems implemented; the information held and delivered by these systems; and, the service provided in support of the IS function. A common foundation for these pillars is the concept of stakeholder needs. In seeking to appreciate the effectiveness: of delivered IS applications in relation to the job performance of stakeholders, this research developed an understanding of what quality means in an IT context I argue that quality is a more useful criterion for effectiveness than the more customary measures of use and user satisfaction. Respecification of the IS Success Model was then proposed. The second phase of the research was to test this model empirically through judgment panels, focus groups and interviews. Results consistently supported the structure and components of the respecified model. Quality was determined as a multi-dimensional construct, with the key dimensions for the quality of delivered IS differing from those used in the research from other disciplines. Empirical work indicated that end-user stakeholders derived their evaluations of quality by internally evaluating perceived performance of delivered IS in relation to their expectations for such performance. A short trial explored whether, when overt measurement of expectations was concurrent with the measurement of perceptions, a more revealing appraisal of delivered IS quality was provided than when perceptions alone were measured. Results revealed a difference between the two measures. Using the New IS Success Model as the foundation, and drawing upon the related theoretical and empirical research, an instrument was developed to measure the quality/effectiveness of delivered IS applications. Four trials of this instrument, QUALIT, are documented. Analysis of results from preliminary trials indicates promise in terms of business value: the instrument is simple to administer and has the capacity to pinpoint areas of weakness. The research related to the respecification of the New IS Success Model and the associated empirical studies, including the development of QTJALIT, have both contributed to the development of theory about IS Effectiveness. More precisely, my research has reviewed the components of an information system, the dimensions comprising these components and the indicators of each, and based upon these findings, formulated an instrument by which to measure the effectiveness of a delivered IS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Invoking the resource-based view (RBV), this study investigates relationships between management control systems (MCSs) use, including information use from performance measurement systems (PMSs), and organisational capabilities in the context of academic units of Australian universities. Increased competition and attention to distinctive capabilities amongst universities, particularly at their strategic operating unit level of Schools 1, provides the setting for application of this theoretic perspective. The objective of this study is to model various relationships between diagnostic and interactive use of MCSs, attention given to centrally-imposed and discretionary types of PMS information, the strength of capabilities of the academic unit and, in turn, performance of the academic units. This objective is investigated using a field survey in which a mail survey instrument is administered to a census of all Heads of Schools in all 39 universities in Australia. Valid responses were received from 166 Heads. Principal components factor analysis finds that Heads conceived capabilities of their unit in functional dimensions, not in generic dimensions as found in prior literature; Heads also considered performance measures in terms of their importance (critical or discretionary) rather than type (financial versus non-financial). Partial least-squares analysis is then used for path modelling, and several significant results are obtained. Highlights are that diagnostic MCS use and centrally-imposed performance measures, i.e., key performance indicators, but not interactive MCS use or discretionary performance measures, significantly relate to some or all of the strength of capabilities in the fields of teaching, research and networking, and in turn indirectly relate to performance of the academic units. The findings have practical implications for styles of control systems use; focus on selected key performance measures; and development of organisational capabilities for achievement of superior performance by academic schools in universities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automated laparoscopic instrument capable of non-invasive measurement of tip/tissue interaction forces for direct application in robotic assisted minimally invasive surgery systems_ is introduced in this paper. It has the capability to measure normal grasping forces as well as lateral interaction forces without any sensor mounted on the tip jaws. Further to non-invasive actuation of the tip, the proposed instrument is also able to change the grasping direction during surgical operation. Modular design of the instrument allows conversion between surgical modalities (e.g., grasping, cutting, and dissecting). The main focus of this paper is on evaluation of the grasping force capability of the proposed instrument. The mathematical formulation of fenestrated insert is presented and its non-linear behaviour is studied. In order to measure the stiffness of soft tissues, a device was developed that is also described in this paper. Tissue characterisation experiments were conducted and results are presented and analysed here. The experimental results verify the capability of the proposed instrument in accurately measuring grasping forces and in characterising artificial tissue samples of varying stiffness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of this study was to compare the increase of the root canal area after instrumentation with EndoSequence or ProTaper rotary systems. Methods: Twenty-two mesial root canals from mandibular molars were instrumented. Teeth were mounted on a base, numbered, and divided into 2 groups; teeth from 1-11 (PT group) were instrumented by using the ProTaper system, and teeth from 12-22 (ES group) were instrumented by using the EndoSequence system. Cone beam computed tomography was performed on all teeth before and after instrumentation. Measurements at 3,5, and 7 mm as well as differences in instrument performance were statistically compared by the Student t test at 5% significance level. Results: Both systems increased significantly the root canal area (P < .05) at all levels. Comparison between the rotary systems showed significantly greater increase (P < .05) for EndoSequence at 3 mm, with no statistically significant difference (P < .05) at the other levels. Conclusions: Both rotary systems increased significantly the root canal area. (J Endod 2010;36:1179-1182)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An automatic Procedure with a high current-density anodic electrodissolution unit (HDAE) is proposed for the determination of aluminium, copper and zinc in non-ferroalloys by flame atonic absorption spectrometry, based on the direct solid analysis. It consists of solenoid valve-based commutation in a flow-injection system for on-line sample electro-dissolution and calibration with one multi-element standard, an electrolytic cell equipped with two electrodes (a silver needle acts as cathode, and sample as anode), and an intelligent unit. The latter is assembled in a PC-compatible microcomputer for instrument control, and far data acquisition and processing. General management of the process is achieved by use of software written in Pascal. Electrolyte compositions, flow rates, commutation times, applied current and electrolysis time mere investigated. A 0.5 mol l(-1) HNO3 solution was elected as electrolyte and 300 A/cm(2) as the continuous current pulse. The performance of the proposed system was evaluated by analysing aluminium in Al-allay samples, and copper/zinc in brass and bronze samples, respectively. The system handles about 50 samples per hour. Results are precise (R.S.D < 2%) and in agreement with those obtained by ICP-AES and spectrophotometry at a 95% confidence level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As compared with continuous rotary systems, reciprocating motion is believed to increase the fatigue resistance of NiTi instruments. We compared the cyclic fatigue and torsional resistance of reciprocating single-file systems and continuous rotary instrumentation systems in simulated root canals. Eighty instruments from the ProTaper Universal, WaveOne, MTwo, and Reciproc systems (n = 20) were submitted to dynamic bending testing in stainless-steel simulated curved canals. Axial displacement of the simulated canals was performed with half of the instruments (n = 10), with back-and-forth movements in a range of 1.5 mm. Time until fracture was recorded, and the number of cycles until instrument fracture was calculated. Cyclic fatigue resistance was greater for reciprocating systems than for rotary systems (P < 0.05). Instruments from the Reciproc and WaveOne systems significantly differed only when axial displacement occurred (P < 0.05). Instruments of the ProTaper Universal and MTwo systems did not significantly differ (P > 0.05). Cyclic fatigue and torsional resistance were greater for reciprocating systems than for continuous rotary systems, irrespective of axial displacement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A complete census of planetary systems around a volume-limited sample of solar-type stars (FGK dwarfs) in the Solar neighborhood (d a parts per thousand currency signaEuro parts per thousand 15 pc) with uniform sensitivity down to Earth-mass planets within their Habitable Zones out to several AUs would be a major milestone in extrasolar planets astrophysics. This fundamental goal can be achieved with a mission concept such as NEAT-the Nearby Earth Astrometric Telescope. NEAT is designed to carry out space-borne extremely-high-precision astrometric measurements at the 0.05 mu as (1 sigma) accuracy level, sufficient to detect dynamical effects due to orbiting planets of mass even lower than Earth's around the nearest stars. Such a survey mission would provide the actual planetary masses and the full orbital geometry for all the components of the detected planetary systems down to the Earth-mass limit. The NEAT performance limits can be achieved by carrying out differential astrometry between the targets and a set of suitable reference stars in the field. The NEAT instrument design consists of an off-axis parabola single-mirror telescope (D = 1 m), a detector with a large field of view located 40 m away from the telescope and made of 8 small movable CCDs located around a fixed central CCD, and an interferometric calibration system monitoring dynamical Young's fringes originating from metrology fibers located at the primary mirror. The mission profile is driven by the fact that the two main modules of the payload, the telescope and the focal plane, must be located 40 m away leading to the choice of a formation flying option as the reference mission, and of a deployable boom option as an alternative choice. The proposed mission architecture relies on the use of two satellites, of about 700 kg each, operating at L2 for 5 years, flying in formation and offering a capability of more than 20,000 reconfigurations. The two satellites will be launched in a stacked configuration using a Soyuz ST launch vehicle. The NEAT primary science program will encompass an astrometric survey of our 200 closest F-, G- and K-type stellar neighbors, with an average of 50 visits each distributed over the nominal mission duration. The main survey operation will use approximately 70% of the mission lifetime. The remaining 30% of NEAT observing time might be allocated, for example, to improve the characterization of the architecture of selected planetary systems around nearby targets of specific interest (low-mass stars, young stars, etc.) discovered by Gaia, ground-based high-precision radial-velocity surveys, and other programs. With its exquisite, surgical astrometric precision, NEAT holds the promise to provide the first thorough census for Earth-mass planets around stars in the immediate vicinity of our Sun.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate, ex vivo, the precision of five electronic root canal length measurement devices (ERCLMDs) with different operating systems: the Root ZX, Mini Apex Locator, Propex II, iPex, and RomiApex A-15, and the possible influence of the positioning of the instrument tips short of the apical foramen. Material and Methods: Forty-two mandibular bicuspids had their real canal lengths (RL) previously determined. Electronic measurements were performed 1.0 mm short of the apical foramen (-1.0), followed by measurements at the apical foramen (0.0). The data resulting from the comparison of the ERCLMD measurements and the RL were evaluated by the Wilcoxon and Friedman tests at a significance level of 5%. Results: Considering the measurements performed at 0.0 and -1.0, the precision rates for the ERCLMDs were: 73.5% and 47.1% (Root ZX), 73.5% and 55.9% (Mini Apex Locator), 67.6% and 41.1% (Propex II), 61.7% and 44.1% (iPex), and 79.4% and 44.1% (RomiApex A-15), respectively, considering ±0.5 mm of tolerance. Regarding the mean discrepancies, no differences were observed at 0.0; however, in the measurements at -1.0, the iPex, a multi-frequency ERCLMD, had significantly more discrepant readings short of the apical foramen than the other devices, except for the Propex II, which had intermediate results. When the ERCLMDs measurements at -1.0 were compared with those at 0.0, the Propex II, iPex and RomiApex A-15 presented significantly higher discrepancies in their readings. Conclusions: Under the conditions of the present study, all the ERCLMDs provided acceptable measurements at the 0.0 position. However, at the -1.0 position, the ERCLMDs had a lower precision, with statistically significant differences for the Propex II, iPex, and RomiApex A-15.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Within this PhD thesis matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) has been used as a reliable tool for the quantitative characterization of giant molecules, such as alkyl substituted and unsubstituted large polycyclic aromatic hydrocarbons (PAH), which cannot be characterized by conventional analytic techniques due to their lack of solubility. The use of the MALDI solvent-free technique for the sample preparation and the application of the standard addition method have allowed the quantitative characterization of synthetic PAH mixtures. The knowledge, acquired by studying these representative systems, has been then transferred to the quantitative analyses of complex and slightly soluble natural PAH mixtures, such as mesophase pitch. Moreover, the possibility to ionize intractable and insoluble molecules via mass spectrometry has been recognized to be not only a powerful analytical method, but also to represent a unique change to handle giant aromatic systems and to deposit them on a surface for further investigations, in a process, which is defined as “soft-landing”. Within this novel deposition technique, ions of the desired analytes or analyte mixtures are generated by means of an MS ionization source, discriminated by their different mass to charge ratios via a mass analyzer and landed with retention of their structure on a desired surface. This soft-deposition is guaranteed by the use of decelerating potentials, which have in this work been recognized to influence the final packing of the analyte molecules reaching the landing surface. For a more detailed study of the electrical field action on disc-like and rod-like molecules, soft-landing-independent experiments have been additionally carried out. As a result unidirectionally ordered films of the analyte molecules have been obtained due to the application of an external electrical strength. This versatile alignment technique has then been used for obtaining ordered layers of semiconducting materials for the fabrication of organic field effect transistors (OFET) with improved performances.