942 resultados para Infrared emissions
Resumo:
The free radical polymerization of styrene in bulk was monitored by ESR and FT near-infrared spectroscopy at 70°C for a series of concentrations of the initiator, dimethyl 2,2′-azobis(isobutyrate). In order to obtain detailed kinetic information over the intire conversion range, and the gel effect range in particular, conversion and free radical concentration data points were accumulated with exceptionally short time intervals. The polystyrene radical concentration ([St•]) went through a sharp maximum at the gel effect, a feature that has hitherto escaped observation due to the rapid concentration changes in the gel effect range relative to the data point time intervals of previous studies. Temperature measurements throughout the polymerization were employed to calculate that a temperature increase was not the cause of the [St•] maximum, which thus appeares to be a genuine feature of the gel effect of this system under isothermal conditions. The propagation rate constant (kp) as a function of monomer conversion exhibited a marked dependence on initiator concentration at high monomer conversion; the sharp decrease in kp with increasing conversion was shifted to higher conversions with increasing initiator concentration.
Resumo:
Objectives: The present study aimed to investigate the feasibility and practicalities or testing children in special school settings using transient evoked otoacoustic emissions (TEOAE) and tympanometry. Children studying in special schools, particularly those with intellectual impairment, may be highly susceptible to hearing pathologies and can be difficult to assess using traditional test batteries. Researchers have recently suggested the possible applicability of TEOAE testing. in lieu of conventional behavioral methods, as a hearing screening device for persons with intellectual impairment. However, to date. few publications have detailed the particulars and results of such testing. Methods: A total of 489 children, with a mean age of 9.6 years, were tested in 15 special schools. Case information was obtained regarding birth history, medical history and type,degree of impairment, for later comparison with screening results. TEOAEs were collected using Quickscreen mode of the ILO292 Otodynamics Analyzer, whilst tympanometry was performed utilizing a Madsen Zodiac 901 Middle Ear Analyzer. Results: In total, 80% of students were able to be tested using TEOAEs. Average test time per ear was 2 min. However, a large proportion (40 of those able to be tested) failed TEOAE testing in at least one ear. No significant effects were found between could-not-test (CNT) cases and case history factors, A significant difference in TEOAE failure rates was found across history of neonatal special care nursery residency and history of parental concern regarding possible hearing impairment. Failure rates were higher for those who indicated positive histories. A total of 74% of subjects could be tested using tympanometry, with 25% of those able to be tested failing in at least one ear. Notably, neither type nor degree of impairment had any significant bearing on CNT or failure rates for tympanometry or TEOAE screening. Conclusions: Findings of the present investigation lend support to the review of hearing screening programs for children in special schools. with TEOAEs presenting as a potential alternative procedure. Further examination of the performance measures of protocols incorporating TEOAEs would now be advantageous. (C) 2002 Elsevier Science Ireland Ltd. All rights reserved.
Resumo:
Handedness, as a potentially influencing, nonpathologic factor, has not been investigated in relation to transient evoked otoacoustic emissions (TEOAEs). The present study aimed to examine the effects of handedness on the TEOAE spectrum in entry-level schoolchildren, with attention also to possible ear asymmetry. A total of 228 subjects (114 males, 114 females, mean age = 6.3 years) were tested using the ILO292 Otodynamics Analyzer (Quickscreen mode) in quiet rooms in 22 schools. For statistical analysis, subjects were matched for factors such as handedness, gender, age, and history of recent ear infection. The results from subjects with passing TEOAE, pure-tone screening, and tympanometry revealed no significant handedness effect overall, although a significant ear asymmetry effect on the measurement parameters of AB difference, noise level, response level, whole-wave reproducibility, band reproducibility, and signal-to-noise ratios was found.
Resumo:
The molecular orientation in a conventionally extruded PVC pipe, a uniaxially oriented PVC pipe and a biaxially oriented PVC pipe has been studied via Infrared dichroism. The degree of order or crystallinity has also been studied by Differential Scanning Calorimetry and also via Infrared Spectroscopy. The fundamental structural difference between the conventional and oriented pipes was that polymer chains were preferentially aligning in the hoop direction for oriented pipes whereas they were fairly isotropic in the conventional pipe with a slight preferential alignment in the axial direction. Analysis of the C-Cl stretching mode indicated that the uniaxially oriented pipe had much higher alignment of the C-Cl bond in the axial direction than the biaxial pipe, which correlates with higher fracture toughness for circumferential cracking in the biaxial pipe. Both DSC and Infrared spectroscopy detected little change in the crystallinity or order in the oriented pipes compared to the conventionally extruded pipes. (C) 2002 Kluwer Academic Publishers.
Resumo:
Evoked otoacoustic emissions have demonstrated potential for application in the community-based hearing screening of paediatric populations. Distortion-product otoacoustic emissions (DPOAEs), as opposed to transient evoked otoacoustic emissions (TEOAEs), have not been extensively researched in this regard. The current study aimed to describe the range of DPOAE values obtained in a large cohort (1576 ears) of 6-year-old children in school settings and to examine possible ear asymmetry, gender and history of ear infection effects on the data. Results indicated a variety of significant effects, particularly in the high frequencies, for DPOAE signal-to-noise ratio. The measurement parameter, DPOAE amplitude (DP-amp), was found to display potentially less clinical applicability due to large standard deviation values. Use of descriptive normative data, as derived in the present investigation, may contribute toward future improvements in the hearing screening of 6-year-old schoolchildren
Resumo:
This study compares the performance of the Quickscreen and Default protocols of the ILO-96 Otodynamics Analyzer in recording transient evoked otoacoustic emissions (TEOAEs) from adults using clinical decision analysis. Data were collected from 25 males (mean age = 29.0 years, SD = 6.8) and 35 females (mean age = 28.1 years, SD = 9.6). The results showed that the mean signal-to-noise ratios obtained from the Quickscreen were significantly greater than those from the Default protocol at 1,2, and 4 kHz. The comparison of the performance of the two protocols, based on the results using receiver operating characteristics curves, revealed a higher performance of the Quickscreen than the Default protocol at 1 and 4 kHz but not at 2 kHz. In view of the enhanced performance of the Quickscreen over the Default protocol in general, the routine use of the Default protocol for testing adults in audiology clinics should be reconsidered.
Resumo:
Because of the adverse effect of CO2 from fossil fuel combustion on the earth's ecosystems, the most cost-effective method for CO2 capture is an important area of research. The predominant process for CO2 capture currently employed by industry is chemical absorption in amine solutions. A dynamic model for the de-absorption process was developed with monoethanolamine (MEA) solution. Henry's law was used for modelling the vapour phase equilibrium of the CO2, and fugacity ratios calculated by the Peng-Robinson equation of state (EOS) were used for H2O, MEA, N-2 and O-2. Chemical reactions between CO2 and MEA were included in the model along with the enhancement factor for chemical absorption. Liquid and vapour energy balances were developed to calculate the liquid and vapour temperature, respectively.