999 resultados para Implante de Prótese de Válvulas Cardíacas
Resumo:
Próteses sobre implantes esteticamente favoráveis estão diretamente relacionadas com a condição dos tecidos moles e duros que as envolvem. A preservação dos tecidos mucogengivais ao redor de implantes dentários instalados na maxila anterior propicia um sorriso harmonioso, com uma estética bastante agradável. No entanto, em alguns casos, isso não ocorre principalmente pela grande reabsorção tecidual na região, na qual deveria ter sido realizado enxerto ósseo, antes mesmo da instalação dos implantes. Desse modo, o objetivo deste trabalho foi apresentar uma solução reabilitadora estética para essas possíveis falhas durante o planejamento com reabilitações sobre implantes, por meio de gengiva artificial cerâmica.
Resumo:
The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.
Resumo:
Osseointegrated implants have specific nature distinguish them from natural teeth making them more susceptible to the efforts generated by mastication. The absence of periodontal ligament, which absorbs the masticatory forces and allows the movement of the teeth interfere with the reception of occlusal loads and therefore the predictability of implants. In the boneimplant interface did not occur the phenomena of dissipation of impact, even the movement induced. Thus, during planning and installation of implant prosthesis, the type and characteristics of occlusal pattern adopted should be established with criteria to be no grounds for future failures. In this regard we highlight the occlusal overload generated by several reasons like the presence of premature contacts, interference during motion excursive, deleterious habits and inappropriate extensions on cantilevers. Thus, the objective is to provide a review of the literature regarding the importance of occlusion in oral rehabilitation with implants. Factors to be considered in establishing a favorable occlusion, consistent with prostheses on implants will be described
Resumo:
In part I of this article, the factors related to the establishment of a favourable occlusion for the implant prosthodontics as well as its real importance in this kind of rehabilitation were showed up. However, it is known that the occlusal characteristics adopted in implant prosthodontics show specific patterns which must be different between each other in accordance to the type of prosthesis installed. The objective of the second part of this work is to present to the reader, by a literature review, those characteristics, justifying the reason because they must be associated to specific kind of prosthesis for favor the treatment established.
Resumo:
Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.
Resumo:
INTRODUÇÃO: A maioria dos pacientes com perda auditiva, incluindo casos de perdas severas, é beneficiada com o uso de aparelho de amplificação sonora individual. Acredita-se que o implante coclear estabeleça melhores resultados na reabilitação de uma criança com perda auditiva nos casos em que a gravidade da deficiência torna os aparelhos acústicos convencionais incapazes de fornecer informação sonora adequada, já que estes necessitam de reserva coclear suficiente para que ocorra detecção acústica. OBJETIVO: Avaliar se em pacientes portadores de surdez pré-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. SÍNTESE DOS DADOS: Revisão sistemática realizada a partir de consulta a artigos científicos selecionados por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Entre os 2169 artigos consultados, 12 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Entre os desenhos de estudos analisados na revisão, 7 são do tipo coorte prospectivo e 5 são estudos transversais. CONCLUSÃO: O implante coclear demonstrou, através de diversos estudos, ser atualmente, a melhor alternativa para os casos de perdas auditivas bilaterais severas ou profundas, atingindo resultados superiores em percepção e desenvolvimento de fala em crianças pré-linguais quando comparados aos aparelhos de amplificação sonora convencionais.
Resumo:
The copolymer poly (L-co-D,L lactic acid), PLDLA, has gained prominence in the field of temporary prostheses due to the fact that their time of degradation is quite compatible with the requirement in the case of osseous fracture. In this work the in vivo degradation of devices from copolymer, as a system of plates and screws, used in fixation of the tibia of rabbits was studied. The devices were implanted in 15 adult rabbits, albinos, New Zealand race, and they were used as control devices of alloys of titanium (Ti-6Al-4V/ V grade). The use of copolymers, synthesized in the laboratory, was tested in the repair of fracture in rabbits'tibias, being assessed in the following times: 2 weeks, 2 months and 3 months. Morphological analysis of tissue surrounding the plate and screw system, for 2 weeks of implantation, showed the presence of osteoblasts, indicating a pre bone formation. After 2 months there was new bone formation in the region in contact with the polymer. This bone growth occurred simultaneously with the process of PLDLA degradation, invading the region where there was polymer and after 3 months there was an intense degradation of the copolymer and hence greater tissue invasion compared to 2 months which characterized bone formation in a region where the polymer degraded. The in vivo degradation study of the devices for PLDLA by means of histological evaluations during the period of consolidation of the fracture showed the efficiency of plate and screw system, and it was possible to check formation of bone tissue at the implantation site, without the presence of inflammatory reaction
Resumo:
A surdez profunda é uma deficiência que afeta a personalidade, o relacionamento e todo o estilo de vida do paciente. Incapacita os indivíduos de escutarem sons ambientes como sirenes e alarmes que constituem alerta em situações da vida diária e não permite a modulação vocal, tornando a voz esteticamente ruim. A prótese auditiva convencional é eficiente no tratamento de grande parte das deficiências auditivas, porém existem pacientes que não conseguem obter discriminação de palavras e sentenças mesmo com uma prótese auditiva potente. O implante coclear é a alternativa atual para estes pacientes. OBJETIVO: Avaliar o resultado auditivo dos pacientes adultos implantados com o implante coclear multicanal pelo Grupo de Implante Coclear da Disciplina de Otorrinolaringologia da Faculdade de medicina da Universidade de São Paulo. FORMA DE ESTUDO: Estudo de série. CASUÍSTICA E MÉTODO: Foram selecionados 61 pacientes com surdez profunda bilateral que utilizam o implante coclear multicanal por pelo menos seis meses e estudados os resultados auditivos através de testes de reconhecimento de palavras e sentenças. RESULTADOS: O PTA médio obtido pelos pacientes foi 38.7 dB NPS. A média em reconhecimento de sentenças em formato aberto foi de 71.3%, vogais em 86.5%, monossílabos em 52.60% e consoante medial em 52.6%. A maioria dos pacientes está apta ao uso do telefone. CONCLUSÃO: A avaliação auditiva obtida seis meses após a primeira programação do implante demonstra que pacientes de língua portuguesa obtêm excelentes resultados em testes de reconhecimento de palavras e sentenças em apresentação aberta, readquirindo uma audição útil.
Resumo:
Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.
Resumo:
OBJETIVO: Avaliar a incidência de trombo intracardíaco e de tromboembolismo nos três primeiros meses após a troca valvar por bioprótese e identificar fatores de risco para a formação de trombo. MÉTODO:Incluídos 184 pacientes, entre 15 e 75 anos de idade, submetidos a implante de bioprótese e realizados ecocardiogramas transtorácico e transesofágico (ETE) na fase hospitalar, média 8,4±3 dias, e três meses após, média 97,4±21,7 dias. RESULTADOS: Incidência de trombo foi significativamente mais elevada nos pacientes com prótese em posição mitral ou mitroaórtica (21,0%) do que em posição aórtica (2,8%), p<0,001. A análise de regressão logística multivariada identificou a prótese em posição mitral ou mitroaórtica como a única variável independente para a formação de trombo. No seguimento de três meses o ETE evidenciou trombo em 35 (20,7%) dos 169 pacientes com evolução ecocardiográfica, 31,7% nos mitrais e 3,1% nos aórticos, p<0,001. No 3º mês a análise de regressão logística multivariada também identificou a prótese em posição mitral ou mitroaórtica como a única variável independente para a formação de trombo. Durante os três meses de seguimento, três (1,6%) pacientes faleceram e oito (4,3%) apresentaram fenômeno embólico, todos para território cerebral. CONCLUSÃO: A incidência de trombo nos três primeiros meses, após o implante da bioprótese foi 14,1% nos 10 primeiros dias e 20,7% em três meses; a prótese em posição mitral ou mitroaórtica foi identificada como fator de risco para a formação de trombo; a incidência de fenômenos embólicos diagnosticados clinicamente foi inferior à proporção de trombo atrial documentado pelo ecocardiograma.
Resumo:
OBJETIVO: Estudar retrospectivamente os resultados de 264 pacientes submetidos à implementação cirúrgica de válvula modelo Omnicarbon entre abril 1985 e maio 1995. MÉTODOS: No momento da cirurgia, a média de idade dos pacientes que receberam essa prótese mecânica era de 57±11 anos. As válvulas modelo Omnicarbon foram colocadas em posição aórtica em 36% dos casos, na posição mitral em 44% dos casos, e nas duas posições em 20% dos casos. O seguimento clínico foi feito cuidadosamente, com a maioria dos pacientes submetidos ao exame físico em nossa clínica. Levando em conta o histórico do caso, os cardiologistas faziam perguntas aos pacientes sobre as complicações relacionadas à válvula. RESULTADOS: O seguimento acumulado dos pacientes foi de 1291 anos, com média de seguimento de 5,4 anos. A sobrevida após 10 anos foi de 79,4±3,9%, incluindo todas as causas de morte e os casos de mortalidade precoce. As complicações relatadas durante os 11 anos de estudo incluem: tromboembolismo (0,1 %), hemorragia (0,4%), endocardite (0,2%), e insuficiência não-estrutural (1,2%). Não foram detectadas anemia hemolítica, trombose valvar, ou insuficiência estrutural durante esse longo período de estudo. A capacidade funcional desses pacientes foi avaliada subjetivamente pelo sistema de classificação da NYHA. Com o tempo de seguimento maior do que 5 anos em média, nossos pacientes que receberam a válvula modelo Omnicarbon se encontram na classe I ou II da NYHA. CONCLUSÃO: As próteses mecânicas modelo Omnicarbon apresentam um bom desempenho clínico por até 10 anos, tanto em posição aórtica quanto mitral. Os resultados indicam uma baixa incidência de tromboembolismo e complicações hemorrágicas.
Resumo:
OBJETIVO: Avaliar a redução do volume de hiperplasia intimal após angioplastia com stents com sirolimus (Cypher®) comparados com os stents não-recobertos de estrutura metálica fina (Pixel®) em pacientes com vasos pequenos. MÉTODOS: Oitenta pacientes com doença arterial coronariana foram prospectivamente incluídos em duas séries consecutivas de tratamento, sendo a primeira empregando stents com sirolimus (50) e a segunda stents não-recobertos de estrutura metálica fina (30). RESULTADOS: Os resultados foram: menor porcentual de obstrução da prótese através do ultra-som intracoronário [5,0% (EP = 0,77) x 39,0% (EP = 4,72), p < 0,001], menor perda tardia intra-stent [0,25 mm (EP = 0,03) x 1,11 mm (EP = 0,13), p < 0,001] e no segmento do vaso [0,30 mm (EP = 0,04) x 0,83 mm (EP = 0,11), p < 0,001], e também menor reestenose intra-stent (0% x 33,3%, p < 0,001) e no segmento do vaso (4% x 36,7%, p < 0,001) com os stents com sirolimus. A sobrevivência livre de eventos foi de 96% com os stents com sirolimus x 86,7% com os stents não-recobertos (p = 0,190). CONCLUSÃO: Os pacientes com vasos de pequeno calibre após o implante de stents com sirolimus evoluem com menor hiperplasia intimal (menor porcentual de obstrução intra-stent e menor perda tardia) do que quando são utilizados stents não-recobertos de estrutura metálica fina. Isto resultou em redução significativa da reestenose angiográfica aos oito meses de evolução.
Resumo:
Mulher com 61 anos de idade, portadora há 11 anos de prótese mecânica, foi internada com dispnéia súbita, palidez e fibrilação atrial. A avaliação diagnóstica incluiu ecocardiografia transesofágica, que demonstrou restrição importante da mobilidade de um dos folhetos da prótese mitral e imobilidade do outro, juntamente com imagem de espessamento compatível com trombo aderido à valva. Foi feito o diagnóstico de trombose de prótese mecânica mitral e instituída terapia trombolítica (rtPA) com sucesso. A paciente está em acompanhamento há mais de um ano, com evolução satisfatória.