955 resultados para Immediate implants


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Treatment of severe compromised tooth in the maxillary anterior area still poses great challenge to the clinicians. Several treatment modalities have been proposed to restore the function and aesthetics in teeth with advanced periodontal disease. The present study aims to report a case of traumatic injury of a left-maxillary central incisor with ridge preservation, orthodontic movement, and implant therapy. A 45-year-old woman underwent the proposed treatment for her left central incisor: basic periodontal therapy, xenogenous bone graft, and guided bone regeneration (GBR). Six months after the graft procedure, orthodontic movement by means of alignment and leveling was made and a coronal displacement of the gingival margin and vertical bone apposition could be observed after 13 months of active movement. Afterwards, a dental implant was placed followed by a connective tissue graft and immediate provisionalization of the crown. In conclusion, orthodontic movement was effective to improve the gingival tissue and alveolar bone prior to implant placement favoring the aesthetic results. Six years postoperatively, the results revealed height and width alveolar bone gain indicating that the treatment proposed was able to restore all the functional and aesthetic parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Maintaining the volume of the alveolar process after extraction can be achieved by immediate implant placement and guided bone regeneration, with or without the use of biomaterials. The authors present a case report with a 10 years follow-up, rehabilitation using osseointegrated implants in the extraction area and maintenance of the volume of the alveolar process with autogenous cortical bone shavings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Placement of implants in fresh sockets is an alternative to try to reduce physiological resorption of alveolar ridge after tooth extraction. This surgery can be used to preserve the bone architecture and also accelerate the restorative procedure. However, the diastasis observed between bone and implant may influence osseointegration. So, autogenous bone graft and/or biomaterials have been used to fill this gap. Considering the importance of bone repair for treatment with implants placed immediately after tooth extraction, this study aimed to present a literature review about biomaterials surrounding immediate dental implants. The search included 56 articles published from 1969 to 2012. The results were based on data analysis and discussion. It was observed that implant fixation immediately after extraction is a reliable alternative to reduce the treatment length of prosthetic restoration. In general, the biomaterial should be used to increase bone/implant contact and enhance osseointegration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little is known about the benefits of low-level laser therapy (LLLT) on improvement of stability of dental implants. The aim of this randomized clinical study was to assess the LLLT effect on implants stability by means of resonance frequency analysis (RFA). Thirty implants were distributed bilaterally in the posterior mandible of eight patients. At the experimental side, the implants were submitted to LLLT (830 nm, 86 mW, 92.1 J/cm(2), 0.25 J, 3 s/point, at 20 points), and on the control side, the irradiation was simulated (placebo). The first irradiation was performed in the immediate postoperative period, and it was repeated every 48 h in the first 14 days. The initial implant stability quotient (ISQ) of the implants was measured by means of RFA. New ISQ measurements were made after 10 days, 3, 6, 9, and 12 weeks. The initial ISQ values ranged from 65-84, with a mean of 76, undergoing a significant drop in stability from the 10th day to the 6th week in the irradiated group, and presenting a gradual increase from the 6th to the 12th week. The highest ISQ values were observed on the 10th day in the irradiated group, and the lowest in the 6th week in both groups. Under the conditions of this study, no evidence was found of any effect of LLLT on the stability of the implants when measured by RFA. Since high primary stability and good bone quality are of major relevancy for a rigid bone-implant interface, additional LLLT may have little impact macroscopically.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To assess the clinical and radiographic outcomes of immediate transmucosal placement of implants into molar extraction sockets. STUDY DESIGN: Twelve-month multicenter prospective cohort study. MATERIAL AND METHODS: Following molar extraction, tapered implants with an endosseous diameter of 4.8 mm and a shoulder diameter of 6.5 mm were immediately placed into the sockets. Molars with evidence of acute periapical pathology were excluded. After implant placement and achievement of primary stability, flaps were repositioned and sutured allowing a non-submerged, transmucosal healing. Peri-implant marginal defects were treated according to the principles of guided bone regeneration (GBR) by means of deproteinized bovine bone mineral particles in conjunction with a bioresrobable collagen membrane. Standardized radiographs were obtained at baseline and 12 months thereafter. Changes in depth and width of the distance from the implant shoulder (IS) and from the alveolar crest (AC) to the bottom of the defect (BD) were assessed. RESULTS: Eighty-two patients (42 males and 40 females) were enrolled and followed for 12 months. They contributed with 82 tapered implants. Extraction sites displayed sufficient residual bone volume to allow primary stability of all implants. Sixty-four percent of the implants were placed in the areas of 36 and 46. GBR was used in conjunction with the placement of all implants. No post-surgical complications were observed. All implants healed uneventfully yielding a survival rate of 100% and healthy soft tissue conditions after 12 months. Radiographically, statistically significant changes (P<0.0001) in mesial and distal crestal bone levels were observed from baseline to the 12-month follow-up. CONCLUSIONS: The findings of this 12-month prospective cohort study showed that immediate transmucosal implant placement represented a predictable treatment option for the replacement of mandibular and maxillary molars lost due to reasons other than periodontitis including vertical root fractures, endodontic failures and caries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: A satisfactory clinical outcome in dental implant treatment relies on primary stability for immediate load bearing. While the geometric design of an implant contributes to mechanical stability, the nature of the implant surface itself is also critically important. Biomechanical and microcomputerized tomographic evaluation of implant osseointegration was performed to compare alternative structural, chemical and biochemical, and/or pharmaceutical surface treatments applied to an identical established implant design. Materials and Methods: Dental implants with the same geometry but with 6 different surface treatments were tested in vivo in a sheep model (pelvis). Peri-implant bone density and removal torque were compared at 2, 4, and 8 weeks after implantation. Implant surfaces tested were: sandblasted and acid-etched titanium (Ti), sandblasted and etched zirconia, Ti coated with calcium phosphate (CaP), Ti modified via anodic plasma-chemical treatment (APC), bisphosphonate-coated Ti (Ti + Bisphos), and Ti coated with collagen containing chondroitin sulfate (CS). Results: All dental implants were well integrated at the time of sacrifice. There were no significant differences observed in peri-implant bone density between implant groups. After 8 weeks of healing, removal torque values for Ti, Ti + CaP, Ti + Bisphos, and Ti + collagen + CS were significantly higher than those for zirconia and Ti + APC. Conclusions: Whereas the sandblasted/acid-etched Ti implant can still be considered the reference standard surface for dental implants, functional surface modifications such as bisphosphonate or collagen coating seem to enhance early peri-implant bone formation and should be studied further.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this review was to evaluate the clinical outcomes for the different time points of implant placement following tooth extraction. MATERIALS AND METHODS: A PubMed search and a hand search of selected journals were performed to identify clinical studies published in English that reported on outcomes of implants in postextraction sites. Only studies that included 10 or more patients were accepted. For implant success/survival outcomes, only studies with a mean follow-up period of at least 12 months from the time of implant placement were included. The following outcomes were identified: (1) change in peri-implant defect dimension, (2) implant survival and success, and (3) esthetic outcomes. RESULTS AND CONCLUSIONS: Of 1,107 abstracts and 170 full-text articles considered, 91 studies met the inclusion criteria for this review. Bone augmentation procedures are effective in promoting bone fill and defect resolution at implants in postextraction sites, and are more successful with immediate (type 1) and early placement (type 2 and type 3) than with late placement (type 4). The majority of studies reported survival rates of over 95%. Similar survival rates were observed for immediate (type 1) and early (type 2) placement. Recession of the facial mucosal margin is common with immediate (type 1) placement. Risk indicators included a thin tissue biotype, a facial malposition of the implant, and a thin or damaged facial bone wall. Early implant placement (type 2 and type 3) is associated with a lower frequency of mucosal recession compared to immediate placement (type 1).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The objectives of this systematic review are (1) to quantitatively estimate the esthetic outcomes of implants placed in postextraction sites, and (2) to evaluate the influence of simultaneous bone augmentation procedures on these outcomes. MATERIALS AND METHODS Electronic and manual searches of the dental literature were performed to collect information on esthetic outcomes based on objective criteria with implants placed after extraction of maxillary anterior and premolar teeth. All levels of evidence were accepted (case series studies required a minimum of 5 cases). RESULTS From 1,686 titles, 114 full-text articles were evaluated and 50 records included for data extraction. The included studies reported on single-tooth implants adjacent to natural teeth, with no studies on multiple missing teeth identified (6 randomized controlled trials, 6 cohort studies, 5 cross-sectional studies, and 33 case series studies). Considerable heterogeneity in study design was found. A meta-analysis of controlled studies was not possible. The available evidence suggests that esthetic outcomes, determined by esthetic indices (predominantly the pink esthetic score) and positional changes of the peri-implant mucosa, may be achieved for single-tooth implants placed after tooth extraction. Immediate (type 1) implant placement, however, is associated with a greater variability in outcomes and a higher frequency of recession of > 1 mm of the midfacial mucosa (eight studies; range 9% to 41% and median 26% of sites, 1 to 3 years after placement) compared to early (type 2 and type 3) implant placement (2 studies; no sites with recession > 1 mm). In two retrospective studies of immediate (type 1) implant placement with bone graft, the facial bone wall was not detectable on cone beam CT in 36% and 57% of sites. These sites had more recession of the midfacial mucosa compared to sites with detectable facial bone. Two studies of early implant placement (types 2 and 3) combined with simultaneous bone augmentation with GBR (contour augmentation) demonstrated a high frequency (above 90%) of facial bone wall visible on CBCT. Recent studies of immediate (type 1) placement imposed specific selection criteria, including thick tissue biotype and an intact facial socket wall, to reduce esthetic risk. There were no specific selection criteria for early (type 2 and type 3) implant placement. CONCLUSIONS Acceptable esthetic outcomes may be achieved with implants placed after extraction of teeth in the maxillary anterior and premolar areas of the dentition. Recession of the midfacial mucosa is a risk with immediate (type 1) placement. Further research is needed to investigate the most suitable biomaterials to reconstruct the facial bone and the relationship between long-term mucosal stability and presence/absence of the facial bone, the thickness of the facial bone, and the position of the facial bone crest.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE The aim of this work was to study the peri-implant soft tissues response, by evaluating both the recession and the papilla indexes, of patients treated with implants with two different configurations. In addition, data were stratified by tooth category, smoking habit and thickness of buccal bone wall. MATERIALS AND METHODS The clinical trial was designed as a prospective, randomized-controlled multicenter study. Adults in need of one or more implants replacing teeth to be removed in the maxilla within the region 15-25 were recruited. Following tooth extraction, the site was randomly allocated to receive either a cylindrical or conical/cylindrical implant. The following parameters were studied: (i) Soft tissue recession (REC) measured by comparing the gingival zenith (GZ) score at baseline (permanent restoration) with that of the yearly follow-up visits over a period of 3 years (V1, V2 and V3). (ii) Interdental Papilla Index (PI): PI measurements were performed at baseline and compared with that of the follow-up visits. In addition, data were stratified by different variables: tooth category: anterior (incisors and canine) and posterior (first and second premolar); smoking habit: patient smoker (habitual or occasional smoker at inclusion) or non-smoker (non-smoker or ex-smoker at inclusion) and thickness of buccal bone wall (TB): TB ≤ 1 mm (thin buccal wall) or TB > 1 mm (thick buccal wall). RESULTS A total of 93 patients were treated with 93 implants. At the surgical re-entry one implant was mobile and then removed; moreover, one patient was lost to follow-up. Ninety-one patients were restored with 91 implant-supported permanent single crowns. After the 3-year follow-up, a mean gain of 0.23 mm of GZ was measured; moreover, 79% and 72% of mesial and distal papillae were classified as >50%/ complete, respectively. From the stratification analysis, not significant differences were found between the mean GZ scores of implants with TB ≤ 1 mm (thin buccal wall) and TB > 1 mm (thick buccal wall), respectively (P < 0.05, Mann-Whitney U-test) at baseline, at V1, V2 and V3 follow-up visits. Also, the other variables did not seem to influence GZ changes over the follow-up period. Moreover, a re-growth of the interproximal mesial and distal papillae was the general trend observed independently from the variables studied. CONCLUSIONS Immediate single implant treatment may be considered a predictable option regarding soft tissue stability over a period of 3 years of follow-up. An overall buccal soft tissue stability was observed during the GZ changes from the baseline to the 3 years of follow-up with a mean GZ reduction of 0.23 mm. A nearly full papillary re-growth can be detectable over a minimum period of 2 years of follow-up for both cylindrical and conical/cylindrical implants. Both the interproximal papilla filling and the midfacial mucosa stability were not influenced by variables such as type of fixture configuration, tooth category, smoke habit, and thickness of buccal bone wall of ≤ 1 mm (thin buccal wall).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM To associate the dimension of the facial bone wall with clinical, radiological, and patient-centered outcomes at least 10 years after immediate implant placement with simultaneous guided bone regeneration in a retrospective study. MATERIAL AND METHODS Primary endpoint was the distance from the implant shoulder (IS) to the first bone-to-implant contact (IS-BIC10y ). Secondary endpoints included the facial bone thickness (BT10y ) 2, 4, and 6 mm apical to the IS, and the implant position. At baseline, the horizontal defect width (HDWBL ) from the implant surface to the alveolar wall was recorded. At recall, distance from the IS to the mucosal margin (IS-MM10y ), degree of soft tissue coverage of the mesial and distal aspects of the implants (PISm10y , PISd10y ; Papilla Index), pocket probing depth (PPD10y ), and patient-centered outcomes were determined. Width of the keratinized mucosa (KM), Full-Mouth Plaque and Bleeding Score (FMPS, FMBS) were available for both time points. RESULTS Of the 20 patients who underwent immediate implant placement with simultaneous guided bone regeneration and transmucosal healing, nine males and eight females with a median age of 62 years (42 min, 84 max) were followed up for a median period of 10.5 y (min 10.1 max 11.5). The 10-year implant survival rate was 100%. Multivariate regression analysis revealed a correlation of the IS-BIC10y , controlled for age and gender, with four parameters: HDWBL (P = 0.03), KMBL -10 (P = 0.02), BT10 4 mm (P = 0.01), and BT10 6 mm (P = 0.01). CONCLUSION Within the conditions of the present study, the horizontal defect width was the main indicator for the vertical dimension of the facial bone. The facial bone dimension was further associated with a reduction in the width of the keratinized mucosa and the dimension of the buccal bone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To provide 2-year clinical- and patient-oriented data with regard to mandibular overdenture assisted by 2 immediately loaded unsplinted implants. Material and methods In this pre-post design, Phase-I clinical trial, 18 edentate individuals (62.4 ± 7.7 years) received a new set of complete denture. Then, following standard procedures, 3 threaded implants (OsseoSpeed TX™, Dentsply Implants, Mölndal, Sweden) were placed in the mandible in each patient, and locator abutments (Zest Anchors LLC, Escondido, U.S.A.) were inserted on the right and left side implants. The midline implant served as a control for within-patient comparison. The immediate loading was conducted within 24 h of surgery. Data were collected at baseline (T0), 12 (T1) and 24 (T2) months after immediate loading. The clinical outcomes included implant survival rate, crestal bone level changes and implant stability. These criteria were assessed through clinical and radiographic examinations as well as resonance frequency analysis. Patient-centered outcomes included patient satisfaction and oral health-related quality of life measured using validated questionnaires. Brunner-Langer approach was used for statistical analysis. Results Implant survival rate for immediate loaded implants was 91.7% at 2-year follow-up. None of the unloaded implants failed. There was no statistically significant difference at baseline and follow-ups with regard to clinical outcomes between loaded and unloaded implants. Patient satisfaction and quality of life improved (p < 0.0001) from baseline to 2-year follow-up. Conclusion Immediate loading protocol did not negatively affect clinical outcomes, satisfaction and quality of life of patients wearing 2-unsplinted-implant mandibular overdenture for 2 years. This conclusion requires confirmation by randomized control trials. Clinical significance statement Mandibular overdenture assisted by two immediately-loaded unsplinted implants is successful treatment based on 2-year clinical and patient-based outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.