991 resultados para INFERIOR VENA-CAVA


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/Aims: Cytokines have a significant role in the response to injury following liver transplantation, but the origin and course of such molecules are not completely known. The aim of this study was to evaluate the production and liver metabolism of the inflammatory cytokines interleukin (IL)-1 beta, IL-6, IL-8, interferon (IFN)-Y and tumor necrosis factor (TNF)-alpha in orthotopic liver transplantation (OLT), comparing the conventional and the piggyback methods. Methodology: We performed a study of 30 patients who underwent elective OLT and were randomized for the conventional or piggyback techniques at the beginning of the operation. The amount of cytokines and their hepatic metabolism were calculated based on plasma concentrations and vascular blood flow at 2, 5, 10, 15, 30, 60, 90, and 120 minutes after revascularization. Results: The amount of IL-1 beta in portal blood was higher in patients who underwent surgery using the conventional technique (estimate interest = 63,783.9 +/- 16,586.1 pg/min, versus 11,979.6 +/- 16,585.7 pg/min in the piggyback group, p=0.035). There were no significant differences between the two operative`s methods for IL-6, IL-8, IFN-Y and TNF-alpha production. The hepatic metabolism of cytokines was not different between groups. Although all the curves showed higher amounts of cytokines with the conventional technique, these were not statistically significant. Conclusion: The study shows the similarity between the two techniques concerning the stimuli for the production of inflammatory molecules.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To evaluate retrospectively the midterm and long-term results of percutaneous endovascular treatment of venous outflow obstruction after pediatric liver transplantation. MATERIALS AND METHODS: During a 9-year period, 18 children with obstruction of a hepatic vein (HV) or inferior vena cava (IVC) anastomosis underwent percutaneous transluminal angioplasty (PTA) with balloon dilation or stent placement in case of PTA failure after liver transplantation. Patients` body weights ranged from 7.7 kg to 42.6 kg (mean, 18.8 kg +/- 9). Potential predictors of patency were compared between balloon dilation and stent placement groups. RESULTS: Forty-two procedures were performed (range, 1-11 per patient; mean, 2). Technical and initial clinical success were achieved in all cases. Major complications included one case of pulmonary artery stent embolization and one case of hemothorax. Three children (25%) with HV obstruction were treated with PTA and nine (75%) were treated with stent placement. Three children with IVC obstruction (75%) were treated with PTA and one (25%) was treated with a stent. There were two children with simultaneous obstruction at the HV and IVC; one was treated with PTA and the other with a stent. Cases of isolated HV stenosis have a higher probability of patency with balloon-expandable stent treatment compared with balloon dilation (P < .05). Follow-up time ranged from 7 days to 9 years (mean, 42 months +/- 31), and the primary assisted patency rate was 100% when stent placement was performed among the first three procedures. CONCLUSIONS: In cases of venous outflow obstruction resulting from HV and/or IVC lesions after pediatric liver transplantation, percutaneous endovascular treatment with balloon dilation or stent placement is a safe and effective alternative treatment that results in long-term patency.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: In this study, we analyzed the time course of hemodynamic efficiency and follow-up in Fontan candidates who underwent the bidirectional Glenn procedure for staged intracardiac cavopulmonary connection (ICPC). Methods: Between 1991 and 2008, 52 patients with univentricular heart (mean age, 3.3 years; range, 2-8 years; 27 female patients [51.9%]) underwent ICPC. The cardiac malformations were as follows: tricuspid atresia, 25 cases (48.0%); common ventricle, 16 cases (30.7%); and pulmonary atresia with intact ventricular septum, 11 cases (21.1%). The intracardiac cavopulmonary procedure was indicated for all 52 cases. In 42 patients (80.7%), an intra-atrial lateral tunnel was constructed with a bovine pericardium patch. In the last 10 consecutive cases (19.3%), we performed a modified surgical technique in which we implanted an intra-atrial corrugated bovine pericardium tube sutured around the superior and inferior vena cava ostium. In all cases, a 4-mm fenestration was made to reduce the intratunnel pressure. All 52 patients had previously undergone a Glenn operation. Results: There were 2 hospital deaths (3.8%) and no recorded late deaths. During the follow-up, all patients were medicated with antiplatelet drugs. To evaluate the hemodynamic performance, we used Doppler echocardiography, computed tomography, and magnetic nuclear resonance studies. There were no prosthesis thromboses during this follow-up period. To evaluate cardiac arrhythmias, we conducted a Holter study. The last 10 patients with an intra-atrial conduit (IAC) presented with sinus rhythm and no arrhythmias during the last 4 years. The 50 surviving patients (96.1%) have been followed up for 6 to 204 months; all these patients are free of reoperation. Conclusion: The Glenn operation, which is performed at an early age, prepares the pulmonary bed to receive the ICPC. The midterm results of the intracardiac Fontan procedure seem to be good. The modified surgical procedure (IAC) can be a good alternative technique to the Fontan procedure in suitable patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background/purpose: The introduction of the piggyback technique for reconstruction of the liver outflow in reduced-size liver transplants for pediatric patients has increased the incidence of hepatic venous outflow block (HVOB). Here, we proposed a new technique for hepatic venous reconstruction in pediatric living-donor liver transplantation. Methods: Three techniques were used: direct anastomosis of the orifice of the donor hepatic veins and the orifice of the recipient hepatic veins (group 1); triangular anastomosis after creating a wide triangular orifice in the recipient inferior vena cava at the confluence of all the hepatic veins (group 2); and a new technique, which is a wide longitudinal anastomosis performed at the anterior wall of the inferior vena cava (group 3). Results: In groups 1 and 2, the incidences of HVOB were 27.7% and 5.7%, respectively. In group 3, no patient presented HVOB (P = .001). No difference was noted between groups 2 and 3. Conclusions: Hepatic venous reconstruction in pediatric living-donor liver transplantation must be preferentially performed by using a wide longitudinal incision at the anterior wall of the recipient inferior vena cava. As an alternative technique, triangulation of the recipient inferior vena cava, including the orifices of the 3 hepatic veins, may be used. Published by Elsevier Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Absence of the horizontal segment of the left portal vein (PV) or absence of bifurcation of the portal vein (ABPV) is extremely rare anomaly. The aim of this study was to study the extra-hepatic PV demonstrating the importance of its careful assessment for the purpose of split-liver transplantation. Human cadaver livers (n = 60) were obtained from routine autopsies. The cutting plane of the liver consisted of a longitudinal section made immediately on the left of the supra-hepatic inferior vena cava through the gallbladder bed preserving the arterial, portal and biliary branches in order to obtain two viable grafts (right lobe-segments V, VI, VII, and VIII and left lobe-segments II, III, and IV) as defined by the main portal scissure. The PV was dissected out and recorded for application of the liver splitting. The PV trunk has been divided into right and left branch in 50 (83.3%) cases. A trifurcation of the PV was found in 9 (15.2%) cases, 3 (5%) was a right anterior segmental PV arising from the left PV and 6 (10%) a right posterior segmental PV arising from the main PV. ABPV occurred in 1 (1.6%) case. Absence of bifurcation of the portal vein is a rare anatomic variation, the surgeon must be cautious and aware of the existence of this exceptional PV anomaly either pre or intra-operatively for the purpose of hepatectomies or even split-liver transplantation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solid pseudopapillary neoplasm of the pancreas is an uncommon but distinctive pancreatic neoplasm with low metastatic potential [1]. Therefore, whenever feasible, an organ-preserving operation should be performed. As previously reported, women with solid pseudopapillary neoplasm of the pancreas may be best treated by more conservative procedures [2]. Recently, laparoscopic pancreatic resections became more common and are being performed in highly specialized centers. There are only six cases of laparoscopic resection for solid pseudopapillary neoplasm of pancreas published in the English literature and, to our knowledge, laparoscopic resection of uncinate process of the pancreas has never been reported [3-6]. This video demonstrates the technical aspects of a totally laparoscopic resection of the uncinate process of the pancreas in a patient with solid pseudopapillary neoplasm. A 26-year-old woman with a 4-cm solid pseudopapillary pancreatic neoplasm was referred for surgical treatment. According to preoperative echoendoscopy, there was a safe margin between neoplasm and main pancreatic duct. The patient was placed in supine position with the surgeon standing between her legs. Four trocars, one 10-mm and three 5-mm, were used. At inspection, the inferior vena cava, transverse colon, duodenum, and pancreas are clearly identified. A Kocher maneuver was performed with complete exposure of pancreatic head and uncinate process. The uncinate process was dissected from the superior mesenteric vein and venous branches were divided between metallic clips or by use of laparoscopic coagulation shears (LCS; Ethicon Endo Surgery Industries, Cincinnati, OH, USA). Blood supply of the duodenum was preserved by ligature of small pancreatic branches from inferior pancreatoduodenal artery. Transection of pancreatic parenchyma was performed using laparoscopic coagulation shears, which is an effective tool for cutting the pancreas [7, 8]. Surgical specimen was removed through a suprapubic incision inside a retrieval bag. A hemostatic absorbable tissue (Surgicel; Ethicon Inc., Cincinnati, OH) was placed in the cutting pancreatic surface, and one round 19F Blake abdominal drain (Ethicon) was left in place. Operative time was 180 minutes and blood loss estimated in 40 ml with no blood transfusion. Hospital stay was 4 days. The patient did not have postoperative pancreatitis or pancreatic leakage, and the abdominal drain was removed on the tenth postoperative day. Final pathology confirmed the diagnosis of solid pseudopapillary neoplasm of pancreas with free surgical margins. The patient was well and asymptomatic 2 months after the procedure. Laparoscopic resection of uncinate process of the pancreas is safe and feasible and should be considered for patients suffering from pancreatic neoplasms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The diagnosis of acute pulmonary thromboembolism (APT) and its severity is challenging. No previous study has examined whether there is a linear relation between plasma DNA concentrations and the severity of APT. We examined this hypothesis in anesthetized dogs. We also examined the changes in plasma DNA concentrations in microspheres lung embolization and whether the therapy of APT with nitrite could modify APT-induced changes in plasma DNA concentrations. In vitro DNA release from blood clots was also studied. Methods: APT was induced with autologous blood clots (saline, 1, 3, or 5 ml/kg) injected into the right atrium. A group of dogs received 300 pm microspheres into the inferior vena cava to produce similar pulmonary hypertension. Another group of dogs received 6.75 mu mol/kg nitrite after APT with blood clots of 5 ml/kg. Hemodynamic evaluations were carried out for 120 min. DNA was extracted from plasma samples using QIAamp DNA Blood Mini Kit and quantified using Quant-iT (TM) PicoGreen (R) dsDNA detection kit at baseline and 120 min after APT. Results: APT produced dose-dependent increases in plasma DNA concentrations. which correlated positively with pulmonary vascular resistance (P=0.002, r=0.897) and with mean pulmonary arterial pressure (P=0.006, r=0.856). Conversely, lung embolization with microspheres produced no significant changes in plasma DNA concentrations. While nitrite attenuated APT-induced pulmonary hypertension, it produced no changes in plasma DNA concentrations. Blood clots released dose-dependent amounts of DNA in vitro. Conclusions: Cell-free DNA concentrations increase in proportion to the severity of APT, probably as a result of increasing amounts of thrombi obstructing the pulmonary vessels. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular - Ramo de especialização: Ultrassonografia Cardiovascular

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abdominal tumors that can grow through vascular lumen and spread to the right heart are rare. Although these tumors have different histologic aspects, they may cause similar abdominal and cardiac symptoms and are a serious risk factor for pulmonary embolism and sudden death when they reach the right atrium and tricuspid valve. The best treatment is radical surgical resection of the entire tumor using cardiopulmonary bypass with or without deep hypothermia and total circulatory arrest. We report the cases of two patients, the first with leiomyosarcoma of the inferior vena cava and the other with intravenous leiomyomatosis of the uterus that showed intravascular growth up to right atrium and ventricle, who underwent successful radical resection in a one-stage procedure with the use of cardiopulmonary bypass. We discuss the clinical and histologic aspects and imaging diagnosis and review the literature.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism. MATERIAL AND METHODS: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs, and body spaces (82 total sites). RESULTS: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8-70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%), right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 hours after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho = 0.719, p < 0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in periumbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction. CONCLUSION: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post-mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A now 36-year-old woman developed a suprahepatic inferior vena cava stenosis, 9 years after liver transplantation for extensive liver echinococcosis. The lesion was treated by percutaneous angioplasty and stenting. Five years later, recurrence of echinococosis with intrastent stenosis together with clinical symptoms, prompted surgical treatment. Hepato-atrial anastomosis was performed under cardiopulmonary bypass with good result.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Compromised growth after operation remains a significant problem in the cardiovascular field. Some benefit of absorbable suture materials has been demonstrated for arterial anastomoses. However, for the low-pressure zone, few data are available. METHODS: To assess growth in high- versus low-pressure zones we transected the abdominal aorta (high-pressure zone) as well as the inferior vena cava (low-pressure zone) in 10 young mongrel dogs using for reanastomosis 7-0 nonabsorbable versus absorbable running sutures in random order. RESULTS: All animals survived and were evaluated over 12 months including body weight (gain, 212% +/- 45% for nonabsorbable versus 218% +/- 8% for absorbable; not significant), angiography, and, after elective sacrifice, detailed studies of aorta and vena cava. Systematic complication of angiographic data at 12 months showed at the suture level an area of 13.8 mm2 for nonabsorbable versus 24.3 +/- 14.4 mm2 for absorbable sutures in the high-pressure zone as compared with 12.9 +/- 4.9 mm2 for nonabsorbable versus 25.3 +/- 15.4 mm2 for absorbable sutures in the low-pressure zone. Residual lumen, calculated as a function of the area above and below the suture, accounted for 35% +/- 10% for nonabsorbable versus 92% +/- 12% for absorbable sutures (p < 0.001) in the high-pressure zone as compared with 37% +/- 13% for nonabsorbable versus 75% +/- 15% for absorbable sutures (p < 0.003) in the low-pressure zone (high versus low, not significant). Poststenotic dilatation accounted for 199% +/- 22% for nonabsorbable versus 126% +/- 43% for absorbable sutures (p < 0.01) in the high-pressure zone. In the low-pressure zone, poststenotic dilatation remained below the inflow area, and the residual poststenotic lumen accounted for 52% +/- 14% for nonabsorbable versus 77% +/- 16% for absorbable sutures (p < 0.004). Macroscopic, light, and scanning electron microscopic studies confirmed different growth patterns in high- versus low-pressure zones. CONCLUSIONS: Aortic narrowing resulted in poststenotic dilatation and unrestricted outflow path (hourglass-type stenosis). Caval narrowing was followed by restriction of poststenotic outflow path (funnel-type stenosis). Absorbable suture material allows for superior growth in both high- and low-pressure zones.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

L'imagerie est de plus en plus utilisée en médecine forensique. Actuellement, les connaissances nécessaires pour interpréter les images post mortem sont faibles et surtout celles concernant les artéfacts post mortem. Le moyen radiologique le plus utilisé en médecine légale est la tomodensitométrie multi-coupes (TDMC). Un de ses avantages est la détection de gaz dans le corps. Cette technique est utile au diagnostic d'embolie gazeuse mais sa très grande sensibilité rend visible du gaz présent même en petite quantité. Les premières expériences montrent que presque tous les corps scannés présentent du gaz surtout dans le système vasculaire. Pour cette raison, le médecin légiste est confronté à un nouveau problème : la distinction entre du gaz d'origine post-mortem et une embolie gazeuse vraie. Pour parvenir à cette distinction, il est essentiel d'étudier la distribution de ces gaz en post mortem. Aucune étude systématique n'a encore été réalisée à ce jour sur ce sujet.¦Nous avons étudié l'incidence et la distribution des gaz présents en post mortem dans les vaisseaux, dans les os, dans les tissus sous-cutanés, dans l'espace sous-dural ainsi que dans les cavités crânienne, thoracique et abdominale (82 sites au total) de manière à identifier les facteurs qui pourraient distinguer le gaz post-mortem artéfactuel d'une embolie gazeuse¦Les données TDMC de 119 cadavres ont été étudiées rétrospectivement. Les critères d'inclusion des sujets sont l'absence de lésion corporelle permettant la contamination avec l'air extérieur, et, la documentation du délai entre le moment du décès et celui du CT-scan (p.ex. rapport de police, protocole de réanimation ou témoin). La présence de gaz a été évaluée semi-quantitativement par deux radiologues et codifiée. La codification est la suivante : grade 0 = pas de gaz, grade 1 = une à quelques bulles d'air, grade 2 = structure partiellement remplie d'air, grade 3 = structure complètement remplie d'air.¦Soixante-quatre des 119 cadavres présentent du gaz (62,2%), et 56 (75,7%) ont montré du gaz dans le coeur. Du gaz a été détecté le plus fréquemment dans le parenchyme hépatique (40%); le coeur droit (ventricule 38%, atrium 35%), la veine cave inférieure (infra-rénale 30%, supra-rénale 26%), les veines sus-hépatiques (gauche 26%, moyenne 29%, droite 22 %), et les espaces du porte (29%). Nous avons constaté qu'une grande quantité de gaz liée à la putréfaction présente dans le coeur droit (grade 3) est associée à des collections de gaz dans le parenchyme hépatique (sensibilité = 100%, spécificité = 89,7%). Pour décrire nos résultats, nous avons construit une séquence d'animation qui illustre le processus de putréfaction et l'apparition des gaz à la TDMC post-mortem.¦Cette étude est la première à montrer que l'apparition post-mortem des gaz suit un modèle de distribution spécifique. L'association entre la présence de gaz intracardiaque et dans le parenchyme hépatique pourrait permettre de distinguer du gaz artéfactuel d'origine post-mortem d'une embolie gazeuse vraie. Cette étude fournit une clé pour le diagnostic de la mort due à une embolie gazeuse cardiaque sur la base d'une TDMC post-mortem.¦Abstract¦Purpose: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism.¦Material and Methods: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs and body spaces (82 total sites).¦Results: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8 to 70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%); right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 h after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho=0.719, p<0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in peri-umbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction.¦Conclusion: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post- mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To assess the performance of 45F vs. 36F smartcanula in CPB with gravity drainage alone. METHODS: Twenty patients were randomly assigned to two groups receiving for venous drainage a smartcanula which is collapsed over a mandrel for trans-atrial insertion into the inferior vena cava and expanded in situ to either 45F or 36F. RESULTS: Valve replacement/repair was realized in 7/10 and/or CABG in 6/10 for 36F (69+/-13 years) vs. 5/10 and 5/10, respectively, for 45F (63+/-11 years: NS). Body weight and surface area (BSA) were 83+/-9 kg (1.9+/-0.2 m2, max 2.2 m2) for 36F vs. 79+/-6 kg: NS (1.9+/-0.1 m2 (NS), max 2.1 m2) for 45F. Insertion and access orifice diameter (area) was 6 mm and 10 mm (78.5 mm2) for the 36F vs. 6 mm and 13 mm (132 mm2) for the 45F (+69%). Calculated target pump flow (2.4 l/min/m2) was 4.7+/-0.4 l/min for 36F vs. 4.5+/-0.3 l/min for 45F. Achieved pump flow accounted for 5.0+/-0.3 l/min for 36F (8% above target) vs. 4.8+/-0.3 l/min for 45F (8% above target): NS. The water balance during the pump run (clear volume added minus hemofilter and urine output) was 2.2+/-0.3 l for 36F vs. 2.0 l for 45F: NS. CONCLUSION: Due to its 'open' wall (the vena cava provides the seal), its reduced wall thickness (range: 0.0-0.4 mm), and its self-expanding design, the 36F smartcanula requiring a 30F access orifice has sufficient drainage capacity by gravity alone for full CPB in adults with a BSA up to 2.2 mm2.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Our objective was to evaluate efficacy and patency of metallic stent placement for symptomatic Budd-Chiari syndrome (BCS) due to prothrombotic disorders. Eleven patients with proved BCS due to prothrombotic disorders were referred for endovascular treatment because of refractory ascites (n=9), abdominal pain (n=8), jaundice (n=6), and/or gastrointestinal bleeding (n=4). Stents were inserted for stenosed hepatic vein (n=7), inferior vena cava (n=2), or mesenterico-caval shunt (n=2). Clinical efficacy and stent patency was evaluated by clinical and Doppler follow-up. After a mean follow-up of 21 months, 6 patients had fully patent stents without reintervention (primary stent patency: 55%). Two patients with hepatic vein stenosis had stent thrombosis and died 4 months after procedure. Restenosis occurred in 3 cases (2 hepatic vein and 1 mesenterico-caval shunt stenosis) and were successfully treated by balloon angioplasty (n=2) and addition of new stents (n=1) leading to a 82% secondary stent patency. Of 9 patients with patent stent, 7 were asymptomatic (77%) at the end of the study. Stent placement is a safe and effective procedure to control of symptomatic BCS. Prothrombotic disorder does not seem to jeopardize patency in anticoagulated patients.