986 resultados para INCREMENTAL EXERCISE
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The perceived exertion has been used for the intensity control and exercise prescription. Among the various scales that estimate the perceived exertion, the Borg’s RPE scale is one of the best known. However, for populations with low levels of schooling or with visual difficulties such as the elderly, the application of these scales becomes more difficult. In previous studies, a color scale of perceived exertion was developed to aim for assistance in application of the scale and interpretation of perceived exertion. This scale showed high correlation with the Borg’s scale and proved to be valid to estimate the perceived exertion. Thereby, the aim of this study was to assess the validity of the color scale of perceived exertion to measure the perceived exertion in adult women of different ages. Participated in the study 12 young adult women with age of 21,7 ± 1,5 years old, and 10 elderly women with age of 60,3 ± 3,5 years old. The participants were submitted to an incremental exercise of treadmill walking with stages of 2 minutes duration. The inicial load was 5,5 km/h and inclination of 6% for young women and 2% for elderly women, both with 2% increments at each stage completed, without changing the speed. Heart rate and oxygen comsuption responses were determined at the 30 finals seconds of each stage. At the 60 finals seconds of each stage participants indicated the perceived exertion for the overall body, for the legs and for the chest, primarily in the color scale and following in the tradicional Borg’s scale. The analysis of variance for repeated measures was used to assess the effect of different loads on the perceived exertion and physiological responses. The correlations betwen physiological variables, color scale and Borg’s scale were analyzed in group and individually. In all analysis the significance...(Complete abstract click electronic access below)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The aim of the study was to investigate the effects of acute supplementation of sodium bicarbonate (NaHCO3) on maximal accumulated oxygen deficit (MAOD) determined by a single supramaximal effort (MAODALT) in running and the correlation with 200- and 400-m running performances. Fifteen healthy men (age, 23 ± 4 years; maximal oxygen uptake, 50.6 ± 6.1 mL·kg(-1)·min(-1)) underwent a maximal incremental exercise test and 2 supramaximal efforts at 110% of the intensity associated with maximal oxygen uptake, which was carried out after ingesting either 0.3 g·kg(-1) body weight NaHCO3 or a placebo (dextrose) and completing 200- and 400-m performance tests. The study design was double-blind, crossover, and placebo-controlled. Significant differences were found between the NaHCO3 and placebo conditions for MAODALT (p = 0.01) and the qualitative inference for substantial changes showed a very likely positive effect (98%). The lactic anaerobic contribution in the NaHCO3 ingestion condition was significantly higher (p < 0.01) and showed a very likely positive effect (99% chance), similar to that verified for peak blood lactate concentration (p < 0.01). No difference was found for time until exhaustion (p = 0.19) or alactic anaerobic contribution (p = 0.81). No significant correlations were observed between MAODALT and 200- and 400-m running performance tests. Therefore, we can conclude that both MAODALT and the anaerobic lactic metabolism are modified after acute NaHCO3 ingestion, but it is not correlated with running performance.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose The purpose of the study was to investigate a possible association between the distance covered in the Hoff test with parameters of maximal oxygen uptake (V_O2MAX), anaerobic threshold, anaerobic fitness, and body composition of professional adult soccer players. Methods Twenty-five professional soccer players (20 ± 3 years) participated in the study. On different days the athletes performed: a graded incremental exercise test in a laboratory to measure V_O2MAX; a specific soccer field test called the Hoff test; a running anaerobic sprint test (RAST); an incremental test on an oval circuit to determine the velocity relative to anaerobic threshold (VAnT) and an estimation of body composition. Results The average V_O2MAX corresponded to 4.1 ± 0.1 L min-1 (54.1 ± 1.2 mL kg-1 min-1 ). The average distance covered during the Hoff test was 1,442.4 ± 30.0 m. The distance covered during the Hoff test showed significant correlations with absolute and expressed in an appropriated scale V_O2MAX (r = 0.44, p = 0.02; r = 0.42, p = 0.02, respectively) while no significant differences were found with body composition, VAnT and RAST variables. Conclusions The present study demonstrated that the distance covered during the Hoff test has weak correlation with V_O2MAX determined in treadmill running, and no correlation with VAnT, body composition and RAST outcomes, probably due to the non-specificity of the proposed tests when associated with the Hoff test.
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Treatment with recombinant human erythropoietin (rhEpo) induces a rise in blood oxygen-carrying capacity (CaO(2)) that unequivocally enhances maximal oxygen uptake (VO(2)max) during exercise in normoxia, but not when exercise is carried out in severe acute hypoxia. This implies that there should be a threshold altitude at which VO(2)max is less dependent on CaO(2). To ascertain which are the mechanisms explaining the interactions between hypoxia, CaO(2) and VO(2)max we measured systemic and leg O(2) transport and utilization during incremental exercise to exhaustion in normoxia and with different degrees of acute hypoxia in eight rhEpo-treated subjects. Following prolonged rhEpo treatment, the gain in systemic VO(2)max observed in normoxia (6-7%) persisted during mild hypoxia (8% at inspired O(2) fraction (F(I)O(2)) of 0.173) and was even larger during moderate hypoxia (14-17% at F(I)O(2) = 0.153-0.134). When hypoxia was further augmented to F(I)O(2) = 0.115, there was no rhEpo-induced enhancement of systemic VO(2)max or peak leg VO(2). The mechanism highlighted by our data is that besides its strong influence on CaO(2), rhEpo was found to enhance leg VO(2)max in normoxia through a preferential redistribution of cardiac output toward the exercising legs, whereas this advantageous effect disappeared during severe hypoxia, leaving augmented CaO(2) alone insufficient for improving peak leg O(2) delivery and VO(2). Finally, that VO(2)max was largely dependent on CaO(2) during moderate hypoxia but became abruptly CaO(2)-independent by slightly increasing the severity of hypoxia could be an indirect evidence of the appearance of central fatigue.
Resumo:
BACKGROUND:
Robotics-assisted tilt table technology was introduced for early rehabilitation of neurological patients. It provides cyclical stepping movement and physiological loading of the legs. The aim of the present study was to assess the feasibility of this type of device for peak cardiopulmonary performance testing using able-bodied subjects.
METHODS:
A robotics-assisted tilt table was augmented with force sensors in the thigh cuffs and a work rate estimation algorithm. A custom visual feedback system was employed to guide the subjects' work rate and to provide real time feedback of actual work rate. Feasibility assessment focused on: (i) implementation (technical feasibility), and (ii) responsiveness (was there a measurable, high-level cardiopulmonary reaction?). For responsiveness testing, each subject carried out an incremental exercise test to the limit of functional capacity with a work rate increment of 5 W/min in female subjects and 8 W/min in males.
RESULTS:
11 able-bodied subjects were included (9 male, 2 female; age 29.6 ± 7.1 years: mean ± SD). Resting oxygen uptake (O
Resumo:
BACKGROUND: The robotics-assisted tilt table (RATT), including actuators for tilting and cyclical leg movement, is used for rehabilitation of severely disabled neurological patients. Following further engineering development of the system, i.e. the addition of force sensors and visual bio-feedback, patients can actively participate in exercise testing and training on the device. Peak cardiopulmonary performance parameters were previously investigated, but it also important to compare submaximal parameters with standard devices. The aim of this study was to evaluate the feasibility of the RATT for estimation of submaximal exercise thresholds by comparison with a cycle ergometer and a treadmill. METHODS: 17 healthy subjects randomly performed six maximal individualized incremental exercise tests, with two tests on each of the three exercise modalities. The ventilatory anaerobic threshold (VAT) and respiratory compensation point (RCP) were determined from breath-by-breath data. RESULTS: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill: oxygen uptake (V'O2) at VAT was [mean (SD)] 1.2 (0.3), 1.5 (0.4) and 1.6 (0.5) L/min, respectively (p < 0.001); V'O2 at RCP was 1.7 (0.4), 2.3 (0.8) and 2.6 (0.9) L/min, respectively (p = 0.001). High correlations for VAT and RCP were found between the RATT vs the cycle ergometer and RATT vs the treadmill (R on the range 0.69-0.80). VAT and RCP demonstrated excellent test-retest reliability for all three devices (ICC from 0.81 to 0.98). Mean differences between the test and retest values on each device were close to zero. The ventilatory equivalent for O2 at VAT for the RATT and cycle ergometer were similar and both were higher than the treadmill. The ventilatory equivalent for CO2 at RCP was similar for all devices. Ventilatory equivalent parameters demonstrated fair-to-excellent reliability and repeatability. CONCLUSIONS: It is feasible to use the RATT for estimation of submaximal exercise thresholds: VAT and RCP on the RATT were lower than the cycle ergometer and the treadmill, but there were high correlations between the RATT vs the cycle ergometer and vs the treadmill. Repeatability and test-retest reliability of all submaximal threshold parameters from the RATT were comparable to those of standard devices.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Educação Física, Programa de Pós-Graduação Stricto-Sensu em Educação Física, 2015.