943 resultados para Hysteresis current control
Resumo:
A multilevel inverter with 12-sided polygonal voltage space vector structure is proposed in this paper. The present scheme provides elimination of common mode voltage variation and 5(th) and 7(th) order harmonics in the entire operating range of the drive. The proposed multi level structure is achieved by cascading only the conventional two-level inverters with asymmetrical DC link voltages. The bandwidths problems associated with conventional hexagonal voltage space vector structure current controllers, due to the presence of 5(th) and 7(th) harmonics, in the over modulation region, is absent in the present 12-sided structure. So a linear voltage control up to 12-step operation is possible, from the present twelve sided scheme, with less current control complexity. An open-end winding structure is used for the induction motor drive.
Resumo:
High frequency PWM inverters produce an output voltage spectrum at the fundamental reference frequency and around the switching frequency. Thus ideally PWM inverters do not introduce any significant lower order harmonics. However, in real systems, due to dead-time effect, device drops and other non-idealities lower order harmonics are present. In order to attenuate these lower order harmonics and hence to improve the quality of output current, this paper presents an \emph{adaptive harmonic elimination technique}. This technique uses an adaptive filter to estimate a particular harmonic that is to be attenuated and generates a voltage reference which will be added to the voltage reference produced by the current control loop of the inverter. This would have an effect of cancelling the voltage that was producing the particular harmonic. The effectiveness and the limitations of the technique are verified experimentally in a single phase PWM inverter in stand-alone as well as g rid interactive modes of operation.
Resumo:
A new type of multi-port isolated bidirectional DC-DC converter is proposed in this study. In the proposed converter, transfer of power takes place through addition of magnetomotive forces generated by multiple windings on a common transformer core. This eliminates the need for a centralised storage capacitor to interface all the ports. Hence, the requirement of an additional power transfer stage from the centralised capacitor can also be eliminated. The converter can be used for a multi-input, multi-output (MIMO) system. A pulse width modulation (PWM) strategy for controlling simultaneous power flow in the MIMO converter is also proposed. The proposed PWM scheme works in the discontinuous conduction mode. The leakage inductance can be chosen to aid power transfer. By using the proposed converter topology and PWM scheme, the need to compute power flow equations to determine the magnitude and direction of power flow between ports is alleviated. Instead, a simple controller structure based on average current control can be used to control the power flow. This study discusses the operating phases of the proposed multi-port converter along with its PWM scheme, the design process for each of the ports and finally experimental waveforms that validate the multi-port scheme.
Resumo:
A regenerative or circulating-power method is presented in this paper for heat run test on the legs of a three-level neutral point clamped (NPC) inverter. This test ensures that only losses are drawn from the dc supply, while rated power is circulated between the two legs, thus minimising wastage of energy. A proportional-resonant (PR) controller based current control scheme is proposed here for the circulating power test setup in NPC inverter. Simulation and experimental results are presented to validate the controller design at various operating conditions. Results of thermal test on the inverter legs are presented at two different operating conditions.
Resumo:
In this paper, a simple single-phase grid-connected photovoltaic (PV) inverter topology consisting of a boost section, a low-voltage single-phase inverter with an inductive filter, and a step-up transformer interfacing the grid is considered. Ideally, this topology will not inject any lower order harmonics into the grid due to high-frequency pulse width modulation operation. However, the nonideal factors in the system such as core saturation-induced distorted magnetizing current of the transformer and the dead time of the inverter, etc., contribute to a significant amount of lower order harmonics in the grid current. A novel design of inverter current control that mitigates lower order harmonics is presented in this paper. An adaptive harmonic compensation technique and its design are proposed for the lower order harmonic compensation. In addition, a proportional-resonant-integral (PRI) controller and its design are also proposed. This controller eliminates the dc component in the control system, which introduces even harmonics in the grid current in the topology considered. The dynamics of the system due to the interaction between the PRI controller and the adaptive compensation scheme is also analyzed. The complete design has been validated with experimental results and good agreement with theoretical analysis of the overall system is observed.
Resumo:
A power filter is necessary to connect the output of a power converter to the grid so as to reduce the harmonic distortion introduced in the line current and voltage by the power converter. Many a times, a transformer is also present before the point of common coupling. Magnetic components often constitute a significant part of the overall weight, size and cost of the grid interface scheme. So, a compact inexpensive design is desirable. A higher-order LCL-filter and a transformer are increasingly being considered for grid interconnection of the power converter. This study proposes a design method based on a three-winding transformer, that generates an integrated structure that behaves as an LCL-filter, with both the filter inductances and the transformer that are merged into a single electromagnetic component. The parameters of the transformer are derived analytically. It is shown that along with a filter capacitor, the transformer parameters provide the filtering action of an LCL-filter. A single-phase full-bridge power converter is operated as a static compensator for performance evaluation of the integrated filter transformer. A resonant integrator-based single-phase phase locked loop and stationary frame AC current controller are employed for grid frequency synchronisation and line current control, respectively.
Resumo:
Closed loop control of a grid connected VSI requires line current control and dc bus voltage control. The closed loop system comprising PR current controller and grid connected VSI with LCL filter is a higher order system. Closed loop control gain expressions are therefore difficult to obtain directly for such systems. In this work a simplified approach has been adopted to find current and voltage controller gain expressions for a 3 phase 4 wire grid connected VSI with LCL filter. The closed loop system considered here utilises PR current controller in natural reference frame and PI controller for dc bus voltage control. Asymptotic frequency response plot and gain bandwidth requirements of the system have been used for current control and voltage controller design. A simplified lower order model, derived for closed loop current control, is used for the dc bus voltage controller design. The adopted design method has been verified through experiments by comparison of the time domain response.
Resumo:
1. Plateau pikas Ochotona curzoniae are considered a pest species on the Tibetan Plateau because they compete with livestock for forage and their burrowing could contribute to soil erosion. The effectiveness of pest control programmes in Tibet has not been measured, and it is not known whether changes in livestock management have exacerbated problems with plateau pikas or compromised their control. This study measured the impact of control programmes and livestock management for forage conservation on populations of plateau pikas in alpine meadow in Naqu District, central Tibet, during 2004 and 2005.2. Current techniques for controlling plateau pikas in spring cause large reductions in abundance, but high density-dependent rates of increase result in no differences between treated and untreated populations by the following autumn. Rates of increase from spring to autumn are not influenced by standing plant biomass or concurrent grazing by yaks Bos grunniens and Tibetan sheep Ovis aries.3. In autumn there was significantly lower biomass outside fenced areas with year-round livestock grazing compared with inside fenced areas with equivalent or higher numbers of plateau pikas but predominantly winter grazing by livestock. Inside fenced areas, control of plateau pikas in spring produced no detectable effect on standing plant biomass at the end of the following summer compared with uncontrolled populations of plateau pikas.4. Regardless of their initial density, populations of plateau pikas declined rapidly over winter outside fenced areas where there was very low standing plant biomass in autumn. However, inside fenced areas with higher plant biomass in autumn, low-density populations of plateau pikas declined more slowly than high-density populations.5. Synthesis and applications. Current control programmes have limited effect because populations of plateau pikas can recover in one breeding season. There was no apparent increase in forage production in areas where plateau pikas were controlled. However, plateau pikas appear to benefit from changes in grazing management, with low-density populations declining less over winter inside fenced areas than elsewhere. It was not evident that control programmes are warranted or that they will improve the livelihoods of Tibetan herders.
Resumo:
本文介绍了一个用于供电系统的DPCS,以及智能控制─实时专家系统控制在DPCS中的应用、特点和实现。
Resumo:
The liver fluke remains an economically significant parasite of livestock and is emerging as an important zoonotic infection of humans. The incidence of the disease has increased in the last few years, as a possible consequence of changes to the World's climate. Future predictions suggest that this trend is likely to continue. Allied to the changing pattern of disease, reports of resistance to triclabendazole (TCBZ) have appeared in the literature, although they do not all represent genuine cases of resistance. Nevertheless, any reports of resistance are a concern, because triclabendazole is the only drug that has high activity against the migratory and damaging juvenile stages of infection. How to deal with the twin problems (of increasing incidence and drug resistance) is the overall theme of the session on “Trematodes: Fasciola hepatica epidemiology and control” and of this review to introduce the session.
Greater knowledge of fluke epidemiology and population genetics will highlight those regions where surveillance is most required and indicate how quickly resistant populations of fluke may arise. Models of disease risk are becoming increasingly sophisticated and precise, with more refined data analysis programmes and Geographic Information Systems (GIS) data. Recent improvements have been made in our understanding of the action of triclabendazole and the ways in which flukes have become resistant to it. While microtubules are the most likely target for drug action, tubulin mutations do not seem to be involved in the resistance mechanism. Rather, upregulation of drug uptake and metabolism processes appear to be more important and the data relating to them will be discussed. The information may help in the design of new treatment strategies or pinpoint potential molecular markers for monitoring fluke populations. Advances in the identification of novel targets for drugs and vaccines will be made by the various “-omics” technologies that are now being applied to Fasciola. A major area of concern in the current control of fasciolosis is the lack of reliable tests for the diagnosis of drug (TCBZ) resistance. This has led to inaccurate reports of resistance, which is hindering successful disease management, as farmers may be encouraged to switch to less effective drugs. Progress with the development of a number of new diagnostic tests will be reviewed.
Resumo:
Background: Fasciola spp. liver fluke cause pernicious disease in humans and animals. Whilst current control is unsustainable due to anthelmintic resistance, gene silencing (RNA interference, RNAi) has the potential to contribute to functional validation of new therapeutic targets. The susceptibility of juvenile Fasciola hepatica to double stranded (ds)RNA-induced RNAi has been reported. To exploit this we probe RNAi dynamics, penetrance and persistence with the aim of building a robust platform for reverse genetics in liver fluke. We describe development of standardised RNAi protocols for a commercially-available liver fluke strain (the US Pacific North West Wild Strain), validated via robust transcriptional silencing of seven virulence genes, with in-depth experimental optimisation of three: cathepsin L (FheCatL) and B (FheCatB) cysteine proteases, and a σ-class glutathione transferase (FheσGST).
Methodology/Principal Findings: Robust transcriptional silencing of targets in both F. hepatica and Fasciola gigantica juveniles is achievable following exposure to long (200–320 nt) dsRNAs or 27 nt short interfering (si)RNAs. Although juveniles are highly RNAi-susceptible, they display slower transcript and protein knockdown dynamics than those reported previously. Knockdown was detectable following as little as 4h exposure to trigger (target-dependent) and in all cases silencing persisted for ≥25 days following long dsRNA exposure. Combinatorial silencing of three targets by mixing multiple long dsRNAs was similarly efficient. Despite profound transcriptional suppression, we found a significant time-lag before the occurrence of protein suppression; FheσGST and FheCatL protein suppression were only detectable after 9 and 21 days, respectively.
Conclusions/Significance: In spite of marked variation in knockdown dynamics, we find that a transient exposure to long dsRNA or siRNA triggers robust RNAi penetrance and persistence in liver fluke NEJs supporting the development of multiple-throughput phenotypic screens for control target validation. RNAi persistence in fluke encourages in vivo studies on gene function using worms exposed to RNAi-triggers prior to infection.
Resumo:
Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica Ramo Energia
Resumo:
The globalization of trade in fish has created many challenges for the developing world specifically with regard to food safety and quality. International organisations have established a good basis for standards in international trade. Whilst these requirements are frequently embraced by the major importers (such as Japan, the EU and the USA), they often impose additional safety requirements and regularly identify batches which fail to meet their strict standards. Creating an effective national seafood control system which meets both the internal national needs as well the requirements for the export market can be challenging. Many countries adopt a dual system where seafood products for the major export markets are subject to tight control whilst the majority of the products (whether for the local market or for more regional trade) are less tightly controlled. With regional liberalization also occurring, deciding on appropriate controls is complex. In the Sultanate of Oman, fisheries production is one of the countries' chief sources of economic revenue after oil production and is a major source of the national food supply. In this paper the structure of the fish supply chain has been analysed and highlighted the different routes operating for the different markets. Although much of the fish are consumed within Oman, there is a major export trade to the local regional markets. Much smaller quantities meet the more stringent standards imposed by the major importing countries and exports to these are limited. The paper has considered the development of the Omani fish control system including the key legislative documents and the administrative structures that have been developed. Establishing modern controls which satisfy the demands of the major importers is possible but places additional costs on businesses. Enhanced controls such as HACCP and other management standards are required but can be difficult to justify when alternative markets do not specify these. These enhanced controls do however provide additional consumer protection and can bring benefits to local consumers. The Omani government is attempting to upgrade the system of controls and has made tremendous progress toward the implementation of HACCP and introducing enhanced management systems into its industrial sector. The existence of strengthened legislative and government support, including subsidies, has encouraged some businesses to implement HACCP. The current control systems have been reviewed and a SWOT analysis approach used to identify key factors for their future development. The study shows that seafood products in the supply chain are often exposed to lengthy handling and distribution process before reaching the consumers, a typical issue faced by many developing countries. As seafood products are often perishable, they safety is compromised if not adequately controlled. The enforcement of current food safety laws in the Sultanate of Oman is shared across various government agencies. Consequently, there is a need to harmonize all regulatory requirements, enhancing the domestic food protection and to continue to work towards a fully risk-based approach in order to compete successfully in the global market.
Resumo:
INTRODUÇÃO: O vírus da dengue é transmitido pela picada do mosquito Aedes aegypti e, o atual programa de controle não atinge o objetivo de impedir sua transmissão. Este trabalho objetivou analisar a relação entre a distribuição espaço-temporal de casos de dengue e os indicadores larvários no município de Tupã, de janeiro de 2004 a dezembro de 2007. MÉTODOS: Foram construídos indicadores larvários por quarteirão e totalidade do município. Utilizou-se o método cross-lagged correlation para avaliar a correlação entre casos de dengue e indicadores larvários. Foi utilizado estimador kernel para análise espacial. RESULTADOS: A correlação cruzada defasada entre casos de dengue e indicadores larvários foi significativa. Os mapas do estimador Kernel da positividade de recipientes indicam uma distribuição heterogênea, ao longo do período estudado. Nos dois anos de transmissão, a epidemia ocorreu em diferentes regiões. CONCLUSÕES: Não ficou evidenciada relação espacial entre infestação larvária e ocorrência de dengue. A incorporação de técnicas de geoprocessamento e análise espacial no programa, desde que utilizados imediatamente após a realização das atividades, podem contribuir com as ações de controle, indicando os aglomerados espaciais de maior incidência.
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system