442 resultados para Hemodynamics


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. Methods: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. Results: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). Conclusion: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise. (ECHOCARDIOGRAPHY, Volume 26, November 2009).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background -Schistosomiasis is a highly prevalent disease with >200 million infected people. Pulmonary hypertension is one of the pulmonary manifestations in this disease, particularly in its hepatosplenic presentation. The aim of this study was to determine the prevalence of pulmonary hypertension in schistosomiasis patients with the hepatosplenic form of the disease. Methods and Results -All patients with hepatosplenic schistosomiasis followed up at the gastroenterology department of our university hospital underwent echocardiographic evaluation to search for pulmonary hypertension. Patients presenting with systolic pulmonary artery pressure >40 mm Hg were further evaluated through right heart catheterization. Our study showed an 18.5% prevalence of patients with elevated systolic pulmonary artery pressure at echocardiography. Invasive hemodynamics confirmed the presence of pulmonary hypertension in 7.7% (95% confidence interval, 3.3 to 16.7) of patients, with a prevalence of precapillary (arterial) pulmonary hypertension of 4.6% (95% confidence interval, 1.5 to 12.7). Conclusions -Our study reinforces the role of echocardiography as a screening tool in the investigation of pulmonary hypertension, together with the need for invasive monitoring for a proper diagnosis. We conclude that hepatosplenic schistosomiasis may account for one of the most prevalent forms of pulmonary hypertension worldwide, justifying the development of further studies to evaluate the effect of specific pulmonary hypertension treatment in this particular form of the disease. (Circulation. 2009; 119: 1518-1523.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to determine whether estrogen therapy enhances postexercise muscle sympathetic nerve activity (MSNA) decrease and vasodilation, resulting in a greater postexercise hypotension. Eighteen postmenopausal women received oral estrogen therapy (ET; n = 9, 1 mg/day) or placebo (n = 9) for 6 mo. They then participated in one 45-min exercise session (cycle ergometer at 50% of oxygen uptake peak) and one 45-min control session (seated rest) in random order. Blood pressure (BP, oscillometry), heart rate (HR), MSNA (microneurography), forearm blood flow (FBF, plethysmography), and forearm vascular resistance (FVR) were measured 60 min later. FVR was calculated. Data were analyzed using a two-way ANOVA. Although postexercise physiological responses were unaltered, HR was significantly lower in the ET group than in the placebo group (59 +/- 2 vs. 71 +/- 2 beats/min, P < 0.01). In both groups, exercise produced significant decreases in systolic BP (145 +/- 3 vs. 154 +/- 3 mmHg, P = 0.01), diastolic BP (71 +/- 3 vs. 75 +/- 2 mmHg, P = 0.04), mean BP (89 +/- 2 vs. 93 +/- 2 mmHg, P = 0.02), MSNA (29 +/- 2 vs. 35 +/- 1 bursts/min, P < 0.01), and FVR (33 +/- 4 vs. 55 +/- 10 units, P = 0.01), whereas it increased FBF (2.7 +/- 0.4 vs. 1.6 +/- 0.2 ml (.) min(-1) (.) 100 ml(-1), P = 0.02) and did not change HR (64 +/- 2 vs. 65 +/- 2 beats/min, P = 0.3). Although ET did not change postexercise BP, HR, MSNA, FBF, or FVR responses, it reduced absolute HR values at baseline and after exercise.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Changes in the shape of the capnogram may reflect changes in lung physiology. We studied the effect of different ventilation/perfusion ratios (V/Q) induced by positive end-expiratory pressures (PEEP) and lung recruitment on phase III slope (S(III)) of volumetric capnograms. Methods Seven lung-lavaged pigs received volume control ventilation at tidal volumes of 6 ml/kg. After a lung recruitment maneuver, open-lung PEEP (OL-PEEP) was defined at 2 cmH(2)O above the PEEP at the onset of lung collapse as identified by the maximum respiratory compliance during a decremental PEEP trial. Thereafter, six distinct PEEP levels either at OL-PEEP, 4 cmH(2)O above or below this level were applied in a random order, either with or without a prior lung recruitment maneuver. Ventilation-perfusion distribution (using multiple inert gas elimination technique), hemodynamics, blood gases and volumetric capnography data were recorded at the end of each condition (minute 40). Results S(III) showed the lowest value whenever lung recruitment and OL-PEEP were jointly applied and was associated with the lowest dispersion of ventilation and perfusion (Disp(R-E)), the lowest ratio of alveolar dead space to alveolar tidal volume (VD(alv)/VT(alv)) and the lowest difference between arterial and end-tidal pCO(2) (Pa-ETCO(2)). Spearman`s rank correlations between S(III) and Disp(R-E) showed a =0.85 with 95% CI for (Fisher`s Z-transformation) of 0.74-0.91, P < 0.0001. Conclusion In this experimental model of lung injury, changes in the phase III slope of the capnograms were directly correlated with the degree of ventilation/perfusion dispersion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the arterial and venous blood flow in women who underwent upper limb axillary dissection surgery for the treatment of breast cancer. Sixty women were divided into two groups: group 1 (G1)-30 women who underwent breast surgery with axillary dissection level II or III (55.6 +/- A 8.6 years); group 2 (G2)-control, 30 women with no breast cancer (57.4 +/- A 7.0 years). Blood flow profile was evaluated by a continuous wave ultrasound Doppler device (Nicolet Vascular Versalab SE(A (R))) with an 8 MHz probe. Axillary, brachial arteries and veins, arm circumference, volumes, and the ankle-brachial index (ABI) were examined. Wilcoxon test and Mann-Whitney tests were applied to analyze blood flow velocity intra-group and between G1 and G2, respectively. The G1 results showed no lymphedema and no peripheral arterial disease (ABI > 0.9). Moreover, the mean blood flow velocity of the vessels ipsilateral to the surgery was significantly higher than the contralateral ones for all vessels examined (P < 0.05). The mean velocity of blood flow of the vessels contralateral to surgery was significantly higher than the axillary artery in G2 (P < 0.05). It can be concluded that women who underwent axillary dissection due to breast cancer showed probable stenosis in the arterial and venous axillary and brachial vessels of the upper limb ipsilateral to the surgery, confirmed by the increase of blood flow velocity, and such obstruction might affect the limb contralateral to the operation site.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The current therapy of acute pulmonary embolism is focused on removing the mechanical obstruction of the pulmonary vessels. However, accumulating evidence suggests that pulmonary vasoconstriction drives many of the hemodynamic changes found in this condition. We examined the effects of stimulation of soluble guanylate cyclase with BAY 41-2272 (5-Cyclopropyl-2-[1-(2-fluoro-benzyl)-1H-pyrazolo[3,4-b]pyridin-3-yl]-pyrimidin-4-ylamine) in an anesthetized dog model of acute pulmonary embolism. Hemodynamic and arterial blood gas evaluations were performed in non-embolized dogs treated with vehicle (N = 5), and in embolized dogs (intravenous injections of microspheres) that received BAY 41-2272 intravenously in doses of 0.03, 0.1, 0.3, and 1 mg/kg/h or vehicle (1 ml/kg/h of 1.13% ethanol in saline, volume/volume). Plasma cGMP and thiobarbituric acid reactive substances concentrations were determined using a commercial enzyme immunoassay and a fluorometric method, respectively. The infusion of BAY 41-2272 resulted in a decrease in pulmonary artery pressure by similar to 29%, and in pulmonary vascular resistance by similar to 46% of the respective increases induced by lung embolization (both P<0.05). While the higher doses of BAY 41-2272 produced no additional effects on the pulmonary circulation, they caused significant arterial hypotension and reduction in systemic vascular resistance (both P<0.05). Although BAY 41-2272 increased cGMP concentrations (P<0.05), it did not affect the hypoxemia and the increased oxidative stress caused by lung embolization. These results suggest that stimulation of soluble guanylate cyclase with low (but not high) doses of BAY 41-2272 produces selective pulmonary vasodilation during acute pulmonary embolism. The dose-dependent systemic effects produced by BAY 41-2272, however, may limit its usefulness in larger doses. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Inhibition of matrix metalloproteinases (MMPs) improves the hemodynamics during acute pulmonary embolism (APE) and oxidative stress upregulates MMPs. We compared the effects of different NO-cGMP pathway activators on APE-induced increases in MMPs. Materials and Methods: Hemodynamic and biochemical evaluations were performed in non-embolized dogs treated with saline (N = 5), and in microspheres embolized dogs receiving saline (n = 9), or nitrite (6.75 mu mol/kg i.v. over 15 min followed by 0.28 mu mol/kg/min; n = 5), or sildenafil (0.25 mg/kg; n = 5), or BAY 41-2272 (0.03, 0.1, 0.3, and 1 mg/kg/h; n = 5). Plasma thiobarbituric acid reactive substances (TBARS) concentrations were determined. Zymograms of plasma samples were performed, and in vitro antioxidant effects or inhibition of MMPs by these drugs were examined. Results: APE increased mean pulmonary artery pressure by similar to 25 mmHg. Nitrite, BAY 41-2272, or sildenafil reversed this increase by similar to 40% (P < 0.05). Similar effects were seen on the pulmonary vascular resistance. While both nitrite and sildenafil produced no systemic effects, the highest dose of BAY 41-2272 produced systemic hypotension (P<0.05). While nitrite and sildenafil blunted the increases in plasma pro-MMP-9 levels and TBARS (all P < 0.05), BAY 41-2272 produced no such effects. Nitrite and sildenafll produced in vitro antioxidant effects and inhibited MMPs only at high concentrations. BAY 41-2272 produced no such effects. Conclusions: Activation of the NO-cGMP pathway with nitrite or sildenafil, but not with BAY 41-2272, attenuates APE-induced oxidative stress and increased MMP-9 levels. These findings are consistent with the idea that NO-cGMP pathway activators with antioxidant effects prevent the release of MMP-9 during APE. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Positive end-expiratory pressure (PEEP) and sustained inspiratory insufflations (SI) during acute lung injury (ALI) are suggested to improve oxygenation and respiratory mechanics. We aimed to investigate the hemodynamic effects of PEEP with and without alveolar recruiting maneuver in a mild ALI model induced by inhalation of hydrochloric acid. Thirty-two pigs were randomly allocated into four groups (Control-PEEP, Control-SI, ALI-PEEP and ALI-SI). ALI was induced by intratracheal instillation of hydrochloric acid. PEEP values were progressively increased and decreased from 5, 10, 15 and 20 cmH(2)O in all groups. Three SIs maneuvers of 30 cmH(2)O for 20 s were applied to the assignable groups between each PEEP level. Transesophageal echocardiography (TEE), global hemodynamics, oxygenation indexes and gastric tonometry were measured 5 min after the maneuvers had been concluded and at each established value of PEEP (5, 10, 15 and 20 cmH(2)O). The cardiac index, ejection fraction and end-diastolic volume of right ventricle were significantly (P < 0.001) decreased with PEEP in both Control and ALI groups. Left ventricle echocardiography showed a significant decrease in end-diastolic volume at 20 cmH(2)O of PEEP (P < 0.001). SIs did not exert any significant hemodynamic effects either early (after 5 min) or late (after 3 h). In a mild ALI model induced by inhalation of hydrochloric acid, significant hemodynamic impairment characterized by cardiac function deterioration occurred during PEEP increment, but SI, probably due to low applied values (30 cmH(2)O), did not exert further negative hemodynamic effects. PEEP should be used cautiously in ALI caused by acid gastric content inhalation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Valve surgery in children is aimed at restoring correct hemodynamics with few reoperations and limited resort to prostheses, which would imply early deterioration or definitive hypocoagulation. OBJECTIVES: Report a series of paediatric pts with acquired mitral valve disease, mostly due to rheumatic disease, in whom it was possible, for the great majority, to repair the damaged valve. DEMOGRAPHICS: Fifty children with predominant mitral valve disease, 47 rheumatic (94%) and 3 after endocarditis were consequently operated by the same surgical team over the last five years. Ages were 12.5+/-3.1 yrs and weights 33.2+/-8.4 Kg, 30 pts presented with predominant mitral regurgitation and 20 pts had significant stenosis. In 8 pts there also moderate to severe aortic regurgitation and in 2 pts severe tricuspid regurgitation was present. Patients were not operated during the acute phase of the disease. Five pts were reoperations and from those, all but one received mechanical prosthesis. RESULTS: In all operations the intention was to repair the mitral valve. In 46 pts complex mitral valvuloplasties were performed extended comissurotomies, shortening of chordae, chordal replacement with PTFE, and reconstruction of valve leaflefts by direct patching or pericardial extension of the retracted posterior leaflet (78.2% cases), plus reshaping of the annulus by using a fixed prosthetic CE ring (sizes 26 to 32) in every case. Ring sizes correlated poorly with body weights, but correlation was close and positive for the use of pericardial advancement of the posterior leaflet (p<0.01). There was no operative mortality, but one pt died early from sepsis and there was no late mortality. Maximum follow up extends now to 50 months (median 28 months) and functional evaluation, at latest follow up, as assessed by Doppler Echocardiography, showed residual mitral regurgitation, mild-moderate in 4 pts and LA-LV gradients mild in 5 and moderate in 2 pts. NYHA functional class, at present follow-up is class I for 43 pts (88%) and class II in the remaining 6 pts. Along the follow-up period 2 pts had to be reoperated for early repair failures and other three for late failures, presently freedom for reoperation is 91.8% at 5 years. CONCLUSIONS: Mitral valve repair in children with rheumatic lesions can be achieved for the great majority of cases by using different techniques. Pericardial extension of the retracted posterior leaflet allowed the use of a bigger size prosthetic ring. Intermediate functional results are good with fair functional classes and few reoperations but follow-up is short and does not allow us to draw conclusions about the long-term results of the repair in these rheumatic patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Mesenchymal stem/stromal cells have unique properties favorable to their use in clinical practice and have been studied for cardiac repair. However, these cells are larger than coronary microvessels and there is controversy about the risk of embolization and microinfarctions, which could jeopardize the safety and efficacy of intracoronary route for their delivery. The index of microcirculatory resistance (IMR) is an invasive method for quantitatively assessing the coronary microcirculation status. OBJECTIVES: To examine heart microcirculation after intracoronary injection of mesenchymal stem/stromal cells with the index of microcirculatory resistance. METHODS: Healthy swine were randomized to receive by intracoronary route either 30x106 MSC or the same solution with no cells (1% human albumin/PBS) (placebo). Blinded operators took coronary pressure and flow measurements, prior to intracoronary infusion and at 5 and 30 minutes post-delivery. Coronary flow reserve (CFR) and the IMR were compared between groups. RESULTS: CFR and IMR were done with a variance within the 3 transit time measurements of 6% at rest and 11% at maximal hyperemia. After intracoronary infusion there were no significant differences in CFR. The IMR was significantly higher in MSC-injected animals (at 30 minutes, 14.2U vs. 8.8U, p = 0.02) and intragroup analysis showed a significant increase of 112% from baseline to 30 minutes after cell infusion, although no electrocardiographic changes or clinical deterioration were noted. CONCLUSION: Overall, this study provides definitive evidence of microcirculatory disruption upon intracoronary administration of mesenchymal stem/stromal cells, in a large animal model closely resembling human cardiac physiology, function and anatomy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rupture of aortic aneurysms (AA) is a major cause of death in the Western world. Currently, clinical decision upon surgical intervention is based on the diameter of the aneurysm. However, this method is not fully adequate. Noninvasive assessment of the elastic properties of the arterial wall can be a better predictor for AA growth and rupture risk. The purpose of this study is to estimate mechanical properties of the aortic wall using in vitro inflation testing and 2D ultrasound (US) elastography, and investigate the performance of the proposed methodology for physiological conditions. Two different inflation experiments were performed on twelve porcine aortas: 1) a static experiment for a large pressure range (0 – 140 mmHg); 2) a dynamic experiment closely mimicking the in vivo hemodynamics at physiological pressures (70 – 130 mmHg). 2D raw radiofrequency (RF) US datasets were acquired for one longitudinal and two cross-sectional imaging planes, for both experiments. The RF-data were manually segmented and a 2D vessel wall displacement tracking algorithm was applied to obtain the aortic diameter–time behavior. The shear modulus G was estimated assuming a Neo-Hookean material model. In addition, an incremental study based on the static data was performed to: 1) investigate the changes in G for increasing mean arterial pressure (MAP), for a certain pressure difference (30, 40, 50 and 60 mmHg); 2) compare the results with those from the dynamic experiment, for the same pressure range. The resulting shear modulus G was 94 ± 16 kPa for the static experiment, which is in agreement with literature. A linear dependency on MAP was found for G, yet the effect of the pressure difference was negligible. The dynamic data revealed a G of 250 ± 20 kPa. For the same pressure range, the incremental shear modulus (Ginc) was 240 ± 39 kPa, which is in agreement with the former. In general, for all experiments, no significant differences in the values of G were found between different image planes. This study shows that 2D US elastography of aortas during inflation testing is feasible under controlled and physiological circumstances. In future studies, the in vivo, dynamic experiment should be repeated for a range of MAPs and pathological vessels should be examined. Furthermore, the use of more complex material models needs to be considered to describe the non-linear behavior of the vascular tissue.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: In previous papers, we described a new experimental model of congenital diaphragmatic hernia in rabbits, and we also reported noninvasive therapeutic strategies for prevention of the functional and structural immaturity of the lungs associated with this defect. In addition to lung hypoplasia, pulmonary hypertension, biochemical, and structural immaturity of the lungs, the hemodynamics of infants and animals with congenital diaphragmatic hernia are markedly altered. Hence, cardiac hypoplasia has been implicated as a possible cause of death in patients with congenital diaphragmatic hernia, and it is hypothesized to be a probable consequence of fetal mediastinal compression by the herniated viscera. Cardiac hypoplasia has also been reported in lamb and rat models of congenital diaphragmatic hernia. The purpose of the present experiment was to verify the occurrence of heart hypoplasia in our new model of surgically produced congenital diaphragmatic hernia in fetal rabbits. METHODS: Twelve pregnant New Zealand rabbits underwent surgery on gestational day 24 or 25 (normal full gestational time - 31 to 32 days) to create left-sided diaphragmatic hernias in 1 or 2 fetuses per each doe. On gestational day 30, all does again underwent surgery, and the delivered fetuses were weighed and divided into 2 groups: control (non-surgically treated fetuses) (n = 12) and congenital diaphragmatic hernia (n = 9). The hearts were collected, weighed, and submitted for histologic and histomorphometric studies. RESULTS: During necropsy, it was noted that in all congenital diaphragmatic hernia fetuses, the left lobe of the liver herniated throughout the surgically created defect and occupied the left side of the thorax, with the deviation of the heart to the right side, compressing the left lung; consequently, this lung was smaller than the right one. The body weights of the animals were not altered by congenital diaphragmatic hernia, but heart weights were decreased in comparison to control fetuses. The histomorphometric analysis demonstrated that congenital diaphragmatic hernia promoted a significant decrease in the ventricular wall thickness and an increase in the interventricular septum thickness. CONCLUSION: Heart hypoplasia occurs in a rabbit experimental model of congenital diaphragmatic hernia. This model may be utilized for investigations in therapeutic strategies that aim towards the prevention or the treatment of heart hypoplasia caused by congenital diaphragmatic hernia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The purpose of this study was to assess portal hemodynamics in patients with portal hypertension due to hepatosplenic schistosomiasis as well as to assess the contribution of splanchnic hyperflow to the pathophysiology of the portal hypertension. METHODS: Sixteen patients with schistosomal portal hypertension and previous history of upper digestive bleeding due to esophageal varices rupture underwent elective esophagogastric devascularization and splenectomy and were prospectively studied. All patients underwent intraoperative invasive hemodynamic portal monitoring with a 4F-thermodilution catheter. The intraoperative portal hemodynamic assessment was conducted after laparotomy (initial) and after esophagogastric devascularization (final). RESULTS: The initial portal pressure was elevated (mean 28.5 ± 4.5 mm Hg), and a significant drop of 25% was observed at the end of the surgery (21.9 ± 4.9 mm Hg). The initial portal flow was elevated (mean 1766.9 ± 686.6 mL/min). A significant fall (42%) occurred at the end of the surgical procedure (1025.62 ± 338.7 mL/min). Fourteen patients (87.5%) presented a portal flow of more than 1200 mL/min, and in 5 cases, values greater than 2000 mL/min were observed. CONCLUSIONS: Esophagogastric devascularization and splenectomy promote a significant reduction of the elevated portal pressure and flow in schistosomal portal hypertension. These data favor the hypothesis of portal hyperflow in the physiopathology of portal hypertension of schistosomiasis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To report the role played by transesophageal echocardiography during implantation of self-expanding aortic endoprostheses (stent) at a hemodynamics laboratory. METHODS: Thirteen patients underwent stent implantation in the descending thoracic aorta with the aid of transesophageal echocardiography during the entire procedure. Indications for stenting were as follows: 8 aortic dissections, 2 true aneurysms, 2 penetrating atherosclerotic ulcers, and 1 traumatic pseudoaneurysm. RESULTS: No complications resulting from the use of transesophageal echocardiography were observed. In 12 patients, the initial result was considered appropriate, with total or partial resolution of the major lesion confirmed by a posterior examination. In 1 patient, the procedure was suspended after transesophageal echocardiography and angiography showed that the proximal aortic diameter was inappropriate. Transesophageal echocardiography contributed to clarifying relevant points, such as aortic diameter, anatomic detail of the intimal lesion, and location and size of the communicating orifice. In addition, it facilitated placing the stent in the target lesion, reduced the time of exposure to radiation and the use of contrast medium, and provided rapid identification of intercurrent events, possibly reducing the total duration of the procedure. CONCLUSION: The use of transesophageal echocardiography during placement of aortic stents seems appropriate. The actual advantages of the procedure will be defined in a comparative prospective study.