STAC is a mobile application (app) designed to promote the benefits of climate-aware urban development in Subtropical environments. Although, STAC is primarily tool for understanding climate efficient buildings in Brisbane, Australia, it also demonstrates how other exemplary buildings operate in other subtropical cities of the world. The STAC research and development team applied research undertaken by the Centre for Subtropical Design (Brisbane) to profile buildings past and present that have contributed to the creation of a vibrant society, a viable economy, a healthy environment, and an authentic sense of place. In collaboration with researchers from the field of Interaction Design, this knowledge and data was collated, processed and curated for presentation via a custom mobile application designed to distribute this important research for review and consideration on-location in local settings and for comparison across all other global subtropical regions and projects identified by this research. This collaboration adopted a Design-based Research (DBR) Methodology guided by the main tenets of research and design iteration and cross-discipline collaboration in real-world settings, resulting in the formulation of contextually-sensitive design principles, theories, and tools for design intervention. Combined with significant context review of available technology and data and subsequent case study analysis of exemplar design applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intelligent buildings should be sustainable, healthy, technologically aware, meet the needs of occupants and business, and should be flexible and adaptable to deal with change. This means the processes of design, construction, commissioning and facilities management including post occupancy evaluation are all equally important. Buildings comprise many systems devised by many people and yet the relationship between buildings and people can only work satisfactorily if there is integrated team with a holistic vision. The address will discuss some trends in the design and management of intelligent buildings for this century.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mirror lightpipes are useful for providing healthy and energy-efficient daylight into buildings where windows and skylights are unsuitable, insufficient or generate too much heat gain. The lightpipes have been installed in dozens of buildings in the UK. Field monitoring has been carried out to assess their performance in four different buildings: the headquaters of a major insurance company, a health clinic, a residential building and a college dining hall In those cases where lighipipes with moderate aspect ratios were installed, good illuminance of up to 450 lux has been obtained with internal/external illuminance ratios around 1%. When long and narrow lightpipes with many bends are used, however, the ratio reduced to around 0.1%. These results showed that lightpipes can be effective daylighting devices provided that excessive aspect ratios and numbers of bends are avoided. Lightpipes with larger diameters should be used whenever possible. The lightpipes often improved signiScantly the visual quality af the interior environment, and high user satisfaction was found even in buildings where a relatively low level of daylight was admitted through the lightpipes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Energy efficient office buildings are intended to provide a comfortable and healthy environment for their occupants as well as reducing the energy consumption of the building. They are often designed as "showcase" buildings illustrating the potential for savings through some innovative design technology. But do such buildings actually deliver the desired energy savings and satisfactory comfort conditions for occupants? Measurements of a "green" University campus building in Victoria, Australia, designed with an innovative fabric energy storage system, demonstrate that the ventilation system is not providing acceptable indoor air quality conditions. The design strategies used to reduce energy consumption have had negative consequences on the air quality of the building. Insufficient fresh air is being drawn into the building leading to an excessive build up of carbon dioxide. It is recommended that monitoring systems need to use a wider range of measurements than temperature alone to guarantee good quality indoor air and working conditions and that commissioning of buildings should include adequate monitoring of the operational performance of the building. Designers need to be made aware of the potential consequences of their decisions when attempting innovative energy-efficient designs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This exploratory mixed method study investigated the factors, including access to nature (i.e. parks and gardens), impacting on inner city high-rise residents' health and wellbeing. Analysis of the integrated findings revealed that a range of factors (including accessibility, choice and control and tenure) impact on residents' health and wellbeing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Owners and tenants of sustainable buildings are now realising the sustainable building that they own or occupy and also how they use the building have a significant impact on their work practices. These stakeholders are demanding sustainability outcomes such as improved occupant health and performance, lower energy and material consumption use as well as encouraging healthy ecosystem in their sustainable building. Clearly the level of user knowledge about a sustainable building and its technologies makes a difference about the actual behaviour towards sustainable buildings (Knott 2007, Stenberg 2007) There remains two major challenge faced by sustainable building occupants: (i) addressing the gap between an occupant's expectations of sustainable building outcomes and what the building actually provides and (ii) overcoming the lack of user knowledge about sustainability design and operation for a particular with regards to performance (Jailani et. al, 2011). This is an innovative study designed to address these challenges. It uses a focus group approach to investigate the gap between (a) user expectations and (b) sustainable building performance, with reference to the relationship between interactive learning process and the level of implementation of sustainability in commercial buildings. The outcome from the study will provide a post-occupancy evaluation of the perception of occupants in sustainable buildings. Most importantly, this information can then assist architects and designers in private and government organisations to successfully develop future sustainable design and policy which can fully capitalise on the original intention when delivering sustainable buildings, as well as providing an innovative feedback mechanism between occupiers and architects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the accelerated trend of global warming, the thermal behavior of existing buildings, which were typically designed based on current weather data, may not be able to cope with the future climate. This paper quantifies, through computer simulations, the increased cooling loads imposed by potential global warming and probable indoor temperature increases due to possible undersized air-conditioning system. It is found from the sample office building examined that the existing buildings would generally be able to adapt to the increasing warmth of 2030 year Low and High scenarios projections and 2070 year Low scenario projection. However, for the 2070 year High scenario, the study indicates that the existing office buildings, in all capital cities except for Hobart, will suffer from overheating problems. When the annual average temperature increase exceeds 2°C, the risk of current office buildings subjected to overheating will be significantly increased. For existing buildings which are designed with current climate condition, it is shown that there is a nearly linear correlation between the increase of average external air temperature and the increase of building cooling load. For the new buildings, in which the possible global warming has been taken into account in the design, a 28-59% increase of cooling capacity under 2070 High scenario would be required to improve the building thermal comfort level to an acceptable standard.