976 resultados para Grafting compatibility


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The complications of impaction bone grafting in revision hip replacement includes fracture of he femur and subsidence of the prosthesis. In this in vitro study we aimed to investigate whether the use of vibration, combined with a perforated tamp during the compaction of morsellised allograft would reduce peak loads and hoop strains in the femur as a surrogate marker of the risk of fracture and whether it would also improve graft compaction and prosthetic stability. We found that the peak loads and hoop strains transmitted to the femoral cortex during graft compaction and subsidence of the stem in subsequent mechanical testing were reduced. This innovative technique has the potential to reduce the risk of intra-operative fracture and to improve graft compaction and therefore prosthetic stability. © 2007 British Editorial Society of Bone and Joint Surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Silicon nanoparticles between 2.5 nm and 30 nm in diameter were functionalized by means of photoassisted hydrosilylation reactions in the aerosol phase with terminal alkenes of varying chain length. Using infrared spectroscopy and nuclear magnetic resonance, the chemical composition of the alkyl layer was determined for each combination of particle size and alkyl chain length. The spectroscopic techniques were used to determine that smaller particles functionalized with short chains in the aerosol phase tend to attach to the interior (β) alkenyl carbon atom, whereas particles >10 nm in diameter exhibit attachment primarily with the exterior (α) alkenyl carbon atom, regardless of chain length. © 2011 American Chemical Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vibration is commonly used in civil engineering applications to efficiently compact aggregates. This study examined the effect of vibration and drainage on bone graft compaction and cement penetration in an in vitro femoral impaction bone grafting model with the use of 3-dimensional micro-computed tomographic imaging. Three regions were analyzed. In the middle and proximal femoral regions, there was a significant increase in the proportion of bone grafts with a reciprocal reduction in water and air in the vibration-assisted group (P < .01) as compared with the control group, suggesting tighter graft compaction. Cement volume was also significantly reduced in the middle region in the vibration-assisted group. No difference was observed in the distal region. This study demonstrates the value of vibration and drainage in bone graft compaction, with implications therein for clinical application and outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-covalent functionalization of CoMoCAT single-wall carbon nanotubes (SWNTs) by bovine serum albumin (BSA) was achieved. Photoluminescence spectra for the functionalized nanotubes showed good dispersion by BSA functionalization. Raman spectra were taken for the sonicated SWNT-BSA solution to establish the signal versus concentration correlation. Cellular uptake of functionalized carbon nanotubes by mouse macrophage (RAW264.7) was then investigated using Raman spectroscopy. For a seeding density of 50% confluence in a culture solution containing 10 μg/ml of BSA-SWNTs, uptake of 200 μg/ml by the macrophages was recorded after 23hr incubation, indicating an active uptake of SWNTs. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new algorithm, representing an important advance in determination of the functional relationship, is first reported here. The algorithm is very useful and convenient for analyzing the incorporation of impurities. To show how the algorithm works, two early and well-known vapor phase epitaxy (VPE) experiments-Ashen's (Ashen, D. J.; Dean, P. J.; Hurle, D. T. J.; Mullin, J. B.; Royle, A.; White, A. M. Gallium Arsenide and Related Compounds, Institute of Physics Conference Series 24, 1974; Institute of Physics: London, 1975; p 229.), involving the doping of silicon and DiLorenzo's (DiLorenzo, J. V. J. Cryst. Growth 1972, 17, 189.), involving the mole fraction effect-are calculated to find the functional relationship between the Si contamination and the partial pressure of HCl. The calculated curves agree with the experimental results. A conclusion that the calculated values are greater than the true values has been drawn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discovers some shortcomings in the algorithm for the incorporation of Si into GaAs in the GaAs VPE process. These faults arise from neglecting a link, the compatibility relationship, in chemical thermodynamics. The meaning of said relationship is as follows: In an equilibrium complex system, each species can only contribute one and the same quantity (its equilibrium quantity) to the different equilibria of the various reactions involving it; yet even under this restriction, every equilibrium constant is satisfied, and all the reaction equilibria coexist compatibly in the system. Only by adding the relationship can the equilibrium theory for the complex system be complete. This paper also tells its position in chemical thermodynamics. Such a compatibility concept directly leads to an equivalence principle: In a complex system, a certain species can usually be simultaneously formed by many chemical reactions; when the system has reached equilibrium under fixed environmental conditions, the equilibrium quantity of said species calculated according to each chemical equation of these reactions will be equal and the various reaction approaches will be equivalent, provided that for all the reactants and all the other products of these reactions their equilibrium quantities in the system are respectively taken as corresponding knowns for the calculations, which is extremely useful for seeking a functional relation among the species' equilibrium quantities in a system (Si contamination is one of the examples). Under the guidance of those arguments, the various schools' algorithms for the Si contamination can be uniformized and simplified, and the contamination quantity relation between Si and O, two very important impurities, is found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to improve stimulus-response compatibility of touchpad in pen-based user interface, we present the tilt cursor, i.e. a cursor dynamically reshapes itself to providing the 3D orientation cue of pen. We also present two experiments that evaluate the tilt cursor’s performance in circular menu selection and specific marking menu selection tasks. Results show that in a specific marking menu selection task, the tilt cursor significantly outperforms the shape-fixed arrow cursor and the live cursor [4]. In addition, results show that by using the tilt cursor, the response latencies for adjusting drawing directions are smaller than that by using the other two kinds of cursors.