924 resultados para GAS-SENSING PROPERTIES


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The gas transport of hydrogen, oxygen, nitrogen, carbon dioxide, and methane gases in a series of poly(aryl ether ketone)s was examined. These polymer membranes have a wide range of permeability coefficients and permselectivity coefficients, showing excellent gas-transport properties. The enhanced interchain interaction in the polymers due to intermolecular hydrogen bonds and ionic bonds results in a considerable increase in permselectivity but a decrease in permeability. On the contrary, the polymers with bulky arkyl substituents show significantly increased permeability. The causes of this trend are interpreted in terms of the free volume, interchain distance, and glass transition temperature together with the respective contribution of gas solubility and diffusivity to the overall permeability. Of interest is the observation that the ionomer IMPEK-K+, which simultaneously contains bulky isopropyl substituents and pendant carboxylate groups, exhibits over twice higher CO2 permeability and 15% higher CO2/CH4 permselectivity than those of bisphenol-A p'olysulfone (PSF). The possibility of using the new synthesized poly(aryl ether ketone)s in gas separation membrane application is also discussed. (C) 1997 John Wiley & Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of aromatic copolyimides was prepared from 1,4-bis(3,4-dicarboxyphenoxy)benzene dianhydride (HQDPA) and 2,2-bis(3,4-dicarboxyphenyl)hexafluoroisopropane dianhydride (6FDA) with 3,3'-dimethyl-4,4'-methylene dianiline (DMMDA) by a chemical imidization. The gas permeability coefficients of the copolyimides to H-2, CO2, O-2, N-2 and CH4 were measured under 7 atm. pressure. The fractional free volume of 6FDA-DMMDA is larger than that of HQDPA-DMMDA, while the chain segmental mobility of 6FDA-DMMDA is lower than that of HQDPA-DMMDA. The gas permeability of 6FDA-DMMDA is much higher than that of HQDPA-DMMDA but the permselectivity of 6FDA-DMMDA for H-2, CO2, O-2, N-2 over CH4 is lower than that of HQDPA-DMMDA. The experimental values of the gas permeability coefficients of the copolyimides are in satisfactory agreement with the values estimated from the gas permeability coefficients of the constituent homopolyimides and their weight fractions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The gas transport properties of a series polyetherimides, which were prepared from 1,4-bis(3,4-dicarboxyphenoxy)benzene dianhydride (HQDPA) with 1,3-phenylenediamine or 3,5-diaminobenzic acid (DBA) or its esters are reported. The effects of carboxylic group (-COOH) and carboxylic ether groups (-COOR), at five positions of 1,3-phenylenediamine moiety, on H-2, CO2, O-2, and N-2 permeability, diffusivity, and solubility of the polyetherimides were investigated. The gas permeability, diffusion, and solubility coefficients of the polyetherimides containing COOR are bigger than those of HQDPA-PDA, but the ideal separation factors and ideal diffusivity selectivity factors are much smaller than that of HQDPA-PDA because COOR decreases chain segmental packing efficiency and increases chain segmental mobility. The permeability coefficients of HQDPA-DBA to H-2, CO2, and O-2 are bigger than those of HQDPA-PDA; the ideal separation factors for gas pairs H-2/N-2, CO2/N-2, and O-2/N-2 are also much bigger than those of HQDPA-PDA. Both the diffusion coefficients of CO2 and O-2 and the ideal diffusivity selectivity factors for CO2/N-2 and O-2/N-2 are bigger than those of HQDPA-PDA because COOH decreases both chain segmental packing efficiency and chain segmental mobility. The copolyimides, which were prepared from 3,5-diaminobenzic acid and 3,5-diaminobenzic esters, have both high permeability and high permselectivity. (C) 1997 John Wiley & Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The gas permeation properties of a series of cardo polyaryletherketone materials are reported, In this series, the hydrogen atoms of benzene rings on the backbone are systematically replaced with different alkyl substituents. The effects of temperature and structure variation on gas permeability and selectivity are discussed in detail. The experimental results revealed that the polyetherketone obtained by the introduction of dimethyl and diisopropyl substituents to phenolphthalein unit is 3 similar to 6 times more permeable than the unmodified one for the gases studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The monolayer and deposition behaviour of a symmetrically substituted copper tetra-4-(2, 4-di-t-amylphenoxy) phthalocyanine (tapCuPc) and an asymmetrically substituted copper [tri-4-(2, 4-di-t-amylphenoxy)-mono-4-(-2-methoxyethoxy)]phthalocyanine (AsyCuPc) were investigated. The results on monolayer behaviour and spectroscopic characterization of the LB films show that both CuPc molecules in a monolayer at the air-water interface and the LB films are stacked and inclined. The gas-sensitive properties show that the responding speed of AsyCuPc LB film is faster than that of tapCuPc LB film.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A high quality NaA zeolite membrane, which shows a H-2/n-C4H10 permselectivity of 106, has been synthesized on a seeded alpha-Al2O3 support by a multistage synthesis method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

First, the direct and indirect electrochemical oxidation of ammonia has been studied by cyclic voltammetry at glassy carbon electrodes in propylene carbonate. In the case of the indirect oxidation of ammonia, its analytical utility of indirect for ammonia sensing was examined in the range from 10 and 100 ppm by measuring the peak current of new wave resulting from reaction between ammonia and hydroquinone, as function of ammonia concentration, giving a sensitivity 1.29 x 10(-7) A ppm(-1) (r(2)=0.999) and limit-of-detection 5 ppm ammonia. Further, the direct oxidation of ammonia has been investigated in several room temperature ionic liquids (RTILs), namely 1-butyl-3-methylimidazolium tetrafluoroborate ([C(4)mim] [BF4]), 1-butyl-3-methylimiclazolium trifluoromethylsulfonate ([C4mim] [OTf]), 1-Ethyl -3-methylimidazolium bis(trifluoromethylsulfonyl)imide ([C(2)mim] [NTf2]), 1-butyl-3-methylimidazolium bis(tritluoromethylsulfonyl)imide ([C4mim] [NTf2]) and 1-butyl-3-methylimidazolium hexafluorophosphate ([C4mim] [PF6]) on a 10 put diameter Pt microdisk electrode. In four of the RTILs studied, the cyclic voltammetric analysis suggests that ammonia is initially oxidized to nitrogen, N-2, and protons, which are transferred to an ammonia molecule, forming NH4+ via the protonation of the anion(s) (A(-)). However, in [C4mim] [PF6], the protonated anion was formed first, followed by NH4+. In all five RTILs, both HA and NH4+ are reduced at the electrode surface, forming hydrogen gas, which is then oxidized. The analytical ability of this work has also been explored further, giving a limit-of-detection close to 50 ppm in [C(2)mim] [NTf2], [C(4)mim] [OTf], [C(4)mim] [BF4], with a sensitivity of ca. 6 x 10(-7) A ppm(-1) (r(2) = 0.999) for all three ionic liquids, showing that the limit of detection was ca. ten times larger than that in propylene carbonate since ammonia in propylene carbonate might be more soluble in comparison with RTILs when considering the higher viscosity of RTILs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report a simple and facile methodology for constructing Pt (6.3 mm x 50 mu m) and Cu (6.3 mm x 30 mu m) annular microband electrodes for use in room temperature ionic liquids (RTILs) and propose their use for amperometric gas sensing. The suitability of microband electrodes for use in electrochemical analysis was examined in experiments on two systems. The first system studied to validate the electrochemical responses of the annular microband electrode was decamethylferrocene (DmFc), as a stable internal reference probe commonly used in ionic liquids, in [Pmim][NTf2], where the diffusion coefficients of DmFc and DmFc(+) and the standard electron rate constant for the DmFc/DmFc(+) couple were determined through fitting chronoamperometric and cyclic voltammetric responses with relevant simulations. These values are independently compared with those collected from a commercially available Pt microdisc electrode with excellent agreement. The second system focuses on O-2 reduction in [Pmim][NTf2], which is used as a model for gas sensing. The diffusion coefficients of O-2 and O-2(-) and the electron transfer rate constant were again obtained using chronoamperometry and cyclic voltammetry, along with simulations. Results determined from the microbands are again consistent to those evaluated from the Pt microdisc electrode when compared these results from home-made microband and commercially available microdisc electrodes. These observations indicate that the fabricated annular microband electrodes are suitable for quantitative measurements. Further the successful use of the Cu electrodes in the O-2 system suggests a cheap disposable sensor for gas detection. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The fabrication and operation of an ammonia chemoresistor is described. The sensor responds to changes in the resistance (impedance) of a thin layer of conductive polymer is due to changes in ammonia concentration. The polyaniline film was deposited by electroless plating (dipping) method on interdigitated array made by photolithographic technique. The PANI film was characterized by UV/VIS and IR Spectroscopy and respectively, Atomic Force Microscopy. Impedance Spectroscopy was used for sensor characterization