967 resultados para Fusão Vertebral
Resumo:
Vertebral fracture assessments (VFAs) using dual-energy X-ray absorptiometry increase vertebral fracture detection in clinical practice and are highly reproducible. Measures of reproducibility are dependent on the frequency and distribution of the event. The aim of this study was to compare 2 reproducibility measures, reliability and agreement, in VFA readings in both a population-based and a clinical cohort. We measured agreement and reliability by uniform kappa and Cohen's kappa for vertebral reading and fracture identification: 360 VFAs from a population-based cohort and 85 from a clinical cohort. In the population-based cohort, 12% of vertebrae were unreadable. Vertebral fracture prevalence ranged from 3% to 4%. Inter-reader and intrareader reliability with Cohen's kappa was fair to good (0.35-0.71 and 0.36-0.74, respectively), with good inter-reader and intrareader agreement by uniform kappa (0.74-0.98 and 0.76-0.99, respectively). In the clinical cohort, 15% of vertebrae were unreadable, and vertebral fracture prevalence ranged from 7.6% to 8.1%. Inter-reader reliability was moderate to good (0.43-0.71), and the agreement was good (0.68-0.91). In clinical situations, the levels of reproducibility measured by the 2 kappa statistics are concordant, so that either could be used to measure agreement and reliability. However, if events are rare, as in a population-based cohort, we recommend evaluating reproducibility using the uniform kappa, as Cohen's kappa may be less accurate.
Resumo:
Neste trabalho descrevemos a apresentação clínica e dos exames de imagem, bem como a utilização da radioterapia exclusiva, em um caso de hemangioma vertebral sintomático. Após três meses de seguimento, houve melhora parcial da dor. Recomendamos dose total de 40 Gy, em frações diárias de 2 Gy. Em seguida é apresentada revisão da literatura.
Resumo:
OBJETIVO: Os autores estabeleceram uma metodologia para avaliar carcinoma espinocelular de cabeça e pescoço, identificando e distinguindo áreas de grande atividade metabólica dentro da neoplasia, associando dados simultaneamente adquiridos, obtidos por diferentes modalidades de aquisição de imagens, combinando informações metabólicas e anatômicas num único exame. MATERIAIS E MÉTODOS: A população estudada consistiu de 17 pacientes com carcinoma espinocelular pertencentes aos arquivos do Departamento de Imagem do Hospital do Câncer, São Paulo. As imagens de tomografia computadorizada (TC) e da tomografia por emissão de pósitrons (PET) com 2-[F-18]-fluoro-2-deoxi-d-glucose (18F-FDG-PET) foram simultaneamente adquiridas utilizando aparelho não dedicado. Os dados originais foram transferidos para uma estação de trabalho independente com o programa Entegra 2NT para gerar a fusão de imagens da PET e TC. RESULTADOS: Os achados foram definidos como positivos na presença de focos com aumento da concentração do radiofármaco em áreas não relacionadas à sua distribuição normal. CONCLUSÃO: A fusão de imagens simultaneamente adquiridas num único exame (18F-FDG-PET e TC) possibilitou o mapeamento topográfico metabólico das lesões estudadas e foi possível localizar áreas de maior atividade metabólica dentro do próprio tumor, verificando recidivas ou metástases, possibilitando aumentar as opções quanto ao planejamento radioterápico ou cirúrgico.
Resumo:
OBJETIVO: Desenvolver e testar a similaridade de modelo de coluna lombar tipo manequim para treinamento de punção transpedicular em vertebroplastia percutânea. MATERIAIS E MÉTODOS: Foram confeccionadas 30 vértebras lombares à base, principalmente, de metacrilato, gesso e etil-vinil-acetato, a partir de molde de borracha baseado em vértebra humana. Os discos intervertebrais foram feitos com silicone para que houvesse similaridade anatômica e fusão de cinco vértebras. O segmento da coluna foi acondicionado no interior de um manequim coberto por tela de etil-vinil-acetato para que não fosse possível a visualização direta. Foi realizado curso teórico para seis especializandos de radiologia e neurorradiologia, que testaram o modelo para vários parâmetros de similaridade com a realidade, realizando 30 punções transpediculares, em três sessões de dez procedimentos por dia, com intervalo de uma semana entre cada sessão. RESULTADOS: Cada aluno realizou 30 punções transpediculares, porém oito punções foram desconsideradas, pois se observaram problemas de manufatura dos modelos durante estes procedimentos. Após a realização das punções, todos os participantes preencheram o formulário de similaridade, com 100% de respostas positivas em relação à similaridade do modelo. CONCLUSÃO: Foi possível o desenvolvimento de modelo para punção transpedicular com similaridade satisfatória com o ser humano, configurando um instrumento de treinamento de vertebroplastia.
Resumo:
This report describes a solution for a restenosis and for the fracture of a stent in the vertebral artery in a patient suffering from vertebrobasilar symptoms. Angiography demonstrates restenosis of a vertebral stent as well as its fracture and migration into the subclavian artery. This complication was managed percutaneously by passing a guide wire through the fractured stent. Pre-dilatation and kissing balloon techniques were applied in both the vertebral and subclavian arteries to modify the stent's dimensions and shape it into the form of a "ring." Postprocedural angiography demonstrated an excellent final result with the assistance of StentBoost visualization. Control angiography at six months also utilized StentBoost imaging and confirmed the patency of the bifurcation and that the stent was not displaced.
Resumo:
A tendinite calcária aguda pré-vertebral é uma condição benigna e rara que apresenta calcificação das fibras do músculo longo do pescoço com reação inflamatória local, sendo esta uma das formas de apresentação menos frequentes da doença por deposição de hidroxiapatita de cálcio. Manifesta-se com dor cervical aguda e/ou odinofagia, podendo ser erroneamente diagnosticada como abscesso retrofaríngeo, espondilodiscite ou alteração decorrente de trauma. Os achados radiológicos na tendinite calcária pré-vertebral são patognomônicos. O conhecimento de tais achados é muito importante, pois o correto diagnóstico possibilita a resolução precoce dos sintomas e evita intervenções desnecessárias em um paciente que apresenta afecção com boa resposta ao tratamento conservador.
Resumo:
Costela intratorácica é definida como uma anomalia congênita rara, possivelmente causada por uma fusão incompleta dos processos cefálico e caudal dos esclerótomos durante a embriogênese. Frequentemente é achado incidental, porém, pode estar associada a malformações vertebrais e a alguns sintomas como dor torácica. O quadro apresentado é de costela intratorácica à esquerda, associada a malformação vertebral, com quadro clínico inespecífico.
Resumo:
O rim em bolo é uma rara anormalidade do trato urinário que pode ser diagnosticada em qualquer faixa etária. Durante investigação de infecção urinária recorrente em criança de 12 anos, foi revelada em tomografia computadorizada contrastada a presença de rim direito ectópico, com fusão renal, drenado por dois ureteres. Foi iniciado tratamento profilático com nitrofurantoína e o paciente se encontra assintomático.
Resumo:
By using DSC data is shown that there are empirical correlations between lattice enthalpy, melting enthalpy and the temperature of melting for adducts, and that is possible, using only a single DSC curve, estimate the value of DM Hmq.
Resumo:
This work describes a process for metal recovery from spent NiMo and CoMo/Al2O3 commercial hydrorefining catalysts. The samples were treated by fusion with potassium hydrogen sulfate (5 h, 600 ºC) with a KHSO4/catalyst mass ratio of 10:1. After fusion the solid was solubilized in water (100 ºC), leaving silicon compounds as residue. Losses of nickel and cobalt may reach 16 wt% of the amount present in the sample, depending on the silicon content. Soluble metals were isolated by selective precipitation techniques (nickel, cobalt, aluminum) or by solvent extraction with methyl-isobutyl ketone (molybdenum) in a hydrochloric acid medium. All metals were recovered in very good yields except for nickel and cobalt in the presence of considerable amounts of silicon. Soluble wastes consist of potassium/sodium sulfates/chlorides. Solid wastes correspond to about 4 wt% of the catalyst and can be discarded in industrial dumps.
Resumo:
This work presents a study on the determination of the optimal experimental conditions for processing spent commercial zeolites in order to recover lanthanide elements and eventually other elements. The process is based on the fusion of the sample with potassium hydrogenosulfate (KHSO4). Three experimental parameters were studied: temperature, reaction time and catalyst/flux mass ratio. After fusion the solid was dissolved in water and the amount of insoluble matter was used to determine the efficiency of the process. The optimized experimental parameters depend on the composition of the sample processed. Under such conditions the insoluble residue corresponds to SiO2. Lanthanide elements and aluminum present in solution were isolated by conventional precipitation techniques; the yields were at least 75 wt%. The final generated wastes correspond to neutral colorless solutions containing alkali chlorides/sulfates and solids that can be disposed of in industrial dumps.
Resumo:
The aim of the present work is to investigate the effects of blending and chemical interesterification reactions on the softening and melting behavior of chicken fat, its stearin and medium chain triacylglycerols, and blends thereof in various ratios. Chemical interesterification is a promising alternative to the current processes of modifying the physical properties of fats. In the experimental design 7 samples corresponding to 7 different blend proportions were used. The results were represented in triangular diagrams. The addition of stearin influenced the softening and melting points. The mixture response surface methodology proved to be an extremely useful tool for the optimization of the fat mixtures.
Resumo:
Invocatio: Q.D.B.V.
Resumo:
Binary mixture phase diagrams are normally obtained from thermal analysis involving freezing point curves. However, that approach is not always reliable and easy to follow to all kinds of mixtures in any proportion. In fact, even for a simple system, such as NaCl-H2O, this freezing methodology gives mixed results when one starts from a solid-solution system, due mostly to the formation of the NaCl.2H2O, which has an incongruent melting point, and the dependence of its solubility with the temperature. In this work we report a trustworthy, simple and cheap method involving heating curves to drawn the NaCl-H2O phase diagram.