Nuclear charge radii of short-lived isotopes can be probed in a nuclear-model independent way via isotope shift measurements. For this purpose a novel technique was developed at GSI, Darmstadt. It combines two-photon laser spectroscopy in the 2s-3s electronic transition of lithium, resonance ionization, and detection via quadrupole mass spectrometry. In this way an accuracy of 5e-5 which is necessary for the extraction of nuclear charge radii, and an overall detection efficiency of 1e-4 is reached. This allowed an isotope shift measurement of Li-11 for the first time at the TRIUMF facility in Vancouver. Additionally, uncertainties in the isotope shift for all other lithium isotopes were reduced by about a factor of four compared to previous measurements at GSI. Results were combined with recent theoretical mass shift calculations in three-electron systems and root-mean-square nuclear charge radii of all lithium isotopes, particulary of the two-neutron halo nucleus Li-11, were determined. Obtained charge radii decrease continuously from Li-6 to Li-9, while a strong increase between Li-9 and Li-11 is observed. This is compared to predictions of various nuclear models and it is found that a multicluster model gives the best overall agreement. Within this model, the increase in charge radius between Li-9 and Li-11is to a large extend caused by intrinsic excitation of the Li-9-like core while the neutron-halo correlation contributes only to a small extend.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thrust fault-related folds in carbonate rocks are characterized by deformation accommodated by different structures, such as joints, faults, pressure solution seams, and deformation bands. Defining the development of fracture systems related to the folding process is significant both for theoretical and practical purposes. Fracture systems are useful constrains in order to understand the kinematical evolution of the fold. Furthermore, understanding the relationships between folding and fracturing provides a noteworthy contribution for reconstructing the geodynamic and the structural evolution of the studied area. Moreover, as fold-related fractures influence fluid flow through rocks, fracture systems are relevant for energy production (geothermal studies, methane and CO2 , storage and hydrocarbon exploration), environmental and social issues (pollutant distribution, aquifer characterization). The PhD project shows results of a study carried out in a multilayer carbonate anticline characterized by different mechanical properties. The aim of this study is to understand the factors which influence the fracture formation and to define their temporal sequence during the folding process. The studied are is located in the Cingoli anticline (Northern Apennines), which is characterized by a pelagic multilayer characterized by sequences with different mechanical stratigraphies. A multi-scale analysis has been made in several outcrops located in different structural positions. This project shows that the conceptual sketches proposed in literature and the strain distribution models outline well the geometrical orientation of most of the set of fractures observed in the Cingoli anticline. On the other hand, the present work suggests the relevance of the mechanical stratigraphy in particular controlling the type of fractures formed (e.g. pressure solution seams, joints or shear fractures) and their subsequent evolution. Through a multi-scale analysis, and on the basis of the temporal relationship between fracture sets and their orientation respect layering, I also suggest a conceptual model for fracture systems formation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Surgical dislocation of the hip in the treatment of acetabular fractures allows the femoral head to be safely displaced from the acetabulum. This permits full intra-articular acetabular and femoral inspection for the evaluation and potential treatment of cartilage lesions of the labrum and femoral head, reduction of the fracture under direct vision and avoidance of intra-articular penetration with hardware. We report 60 patients with selected types of acetabular fracture who were treated using this approach. Six were lost to follow-up and the remaining 54 were available for clinical and radiological review at a mean follow-up of 4.4 years (2 to 9). Substantial damage to the intra-articular cartilage was found in the anteromedial portion of the femoral head and the posterosuperior aspect of the acetabulum. Labral lesions were predominantly seen in the posterior acetabular area. Anatomical reduction was achieved in 50 hips (93%) which was considerably higher than that seen in previous reports. There were no cases of avascular necrosis. Four patients subsequently required total hip replacement. Good or excellent results were achieved in 44 hips (81.5%). The cumulative eight-year survivorship was 89.0% (95% confidence interval 84.5 to 94.1). Significant predictors of poor outcome were involvement of the acetabular dome and lesions of the femoral cartilage greater than grade 2. The functional mid-term results were better than those of previous reports. Surgical dislocation of the hip allows accurate reduction and a predictable mid-term outcome in the management of these difficult injuries without the risk of the development of avascular necrosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To clarify the patterns of frontobasal and frontosinal fractures in children and teenagers and to analyze whether the patterns relate to developmental stage of the facial skeleton.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aims of the study were (1) to determine the cumulative two to twenty-year survivorship of the hip after open reduction and internal fixation of displaced acetabular fractures, (2) to identify factors predicting conversion to total hip arthroplasty or hip arthrodesis, and (3) to create a predictive model that calculates an individual's probability of early need for total hip arthroplasty or hip arthrodesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Falls and fractures in the elderly are among the leading causes of disability. We investigated whether pacemaker implantation prevents falls in patients with SND in a large cohort of patients. Methods. Patient demographics and medical history were collected prospectively. Fall history was retrospectively reconstituted from available medical records. The 10-year probability for major osteoporotic fractures was calculated retrospectively from available medical records using the Swiss fracture risk assessment tool FRAX-Switzerland. Results. During a mean observation period of 2.3 years after implantation, the rates of fallers and injured fallers with fracture were reduced to 15% and 6%, respectively. This corresponds to a relative reduction in the number of fallers of 75% (P < 0.001) and of injured fallers of 63% (P = 0.014) after pacemaker implantation. Similarly, the number of falls was reduced from 60 (48%) before pacemaker implantation to 22 (18%) thereafter (relative reduction 63%, P = 0.035) and the number of falls with injury from 22 (18%) to 7 (6%), which corresponds to a relative reduction of 67%, P = 0.013. Conclusion. In patients with SND, pacemaker implantation significantly reduces the number of patients experiencing falls, the total number of falls, and the risk for osteoporotic fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the difference between the effects of a 5-day and a 1-day course of antibiotics on the incidence of postoperative infection after displaced fractures of the orbit. A total of 62 patients with orbital blow-out fractures were randomly assigned to two groups, both of which were given amoxicillin/clavulanic acid 1.2g intravenously every 8h from the time of admission to 24h postoperatively. The 5-day group were then given amoxicillin/clavulanic acid 625mg orally every 8h for 4 further days. The 1-day group were given placebo orally at the same time intervals. Follow up appointments were 1, 2, 4, 6, and 12 weeks, and 6 months, postoperatively. An infection in the orbital region was the primary end point. Sixty of the 62 patients completed the study. Two of the 29 patients in the 5-day group (6.8%) and 1/31 patients in the 1-day group (3.2%) developed local infections. In the 5-day group 1 patient developed diarrhoea. In the 1-day group 1 patient developed a rash on the trunk. There were no significant differences in the incidence of infection or side effects between the groups. We conclude that in displaced orbital fractures a postoperative 1-day course of antibiotics is as effective in preventing infective complications as a 5-day regimen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To present the functional and radiographic outcome 1 and 6 years after application of a new intramedullary fixation device for proximal humerus fractures. DESIGN: Retrospective case series. SETTING: Level II orthopaedic surgery hospital. PATIENTS: Twenty-six consecutive patients (average age 68.9 years) with 2-, 3- and 4-part fractures of the proximal humerus were operated at a single institution. Follow-up was performed after 1 year (26 patients) and 6 years (16 patients). INTERVENTION: All patients were treated with closed reduction and intramedullary helix wires. MAIN OUTCOME MEASUREMENTS: The Constant-Murley score and the University of California Los Angeles (UCLA) score. Clinical complications and radiological posttraumatic arthritis were recorded. RESULTS: The average Constant-Murley score was 70.3 (points) and 70.7 after 1 and 6 years, respectively; the average UCLA score was 27.2 and 31.5 after 1 and 6 years, respectively. Major complications were 4 revisions for 3 secondary fragment displacements and 1 nonunion with partial avascular osteonecrosis in the first postoperative year. Complications were found predominantly in 4-part fractures (3/5, 60%). There were no further complications or progressive posttraumatic arthritis up to 6 years following surgery. CONCLUSION: The helix wire is well suited for displaced or unstable 2- and 3-part proximal humerus fractures. Adequate functional outcome, a low number of implant displacements, a low number of application morbidity, and infrequent implant removals were recorded. The use of this device is not recommended for 4-part fractures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to assess the ability to extract surgically relevant information from plain radiographs in trimalleolar fractures and to compare this with the information gathered from computed tomography (CT).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Fractures of the mandible (lower jaw) are a common occurrence and usually related to interpersonal violence or road traffic accidents. Mandibular fractures may be treated using open (surgical) and closed (non-surgical) techniques. Fracture sites are immobilized with intermaxillary fixation (IMF) or other external or internal devices (i.e. plates and screws) to allow bone healing. Various techniques have been used, however uncertainty exists with respect to the specific indications for each approach. OBJECTIVES The objective of this review is to provide reliable evidence of the effects of any interventions either open (surgical) or closed (non-surgical) that can be used in the management of mandibular fractures, excluding the condyles, in adult patients. SEARCH METHODS We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 28 February 2013), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library 2013, Issue 1), MEDLINE via OVID (1950 to 28 February 2013), EMBASE via OVID (1980 to 28 February 2013), metaRegister of Controlled Trials (to 7 April 2013), ClinicalTrials.gov (to 7 April 2013) and the WHO International Clinical Trials Registry Platform (to 7 April 2013). The reference lists of all trials identified were checked for further studies. There were no restrictions regarding language or date of publication. SELECTION CRITERIA Randomised controlled trials evaluating the management of mandibular fractures without condylar involvement. Any studies that compared different treatment approaches were included. DATA COLLECTION AND ANALYSIS At least two review authors independently assessed trial quality and extracted data. Results were to be expressed as random-effects models using mean differences for continuous outcomes and risk ratios for dichotomous outcomes with 95% confidence intervals. Heterogeneity was to be investigated to include both clinical and methodological factors. MAIN RESULTS Twelve studies, assessed as high (six) and unclear (six) risk of bias, comprising 689 participants (830 fractures), were included. Interventions examined different plate materials and morphology; use of one or two lag screws; microplate versus miniplate; early and delayed mobilization; eyelet wires versus Rapid IMF™ and the management of angle fractures with intraoral access alone or combined with a transbuccal approach. Patient-oriented outcomes were largely ignored and post-operative pain scores were inadequately reported. Unfortunately, only one or two trials with small sample sizes were conducted for each comparison and outcome. Our results and conclusions should therefore be interpreted with caution. We were able to pool the results for two comparisons assessing one outcome. Pooled data from two studies comparing two miniplates versus one miniplate revealed no significant difference in the risk of post-operative infection of surgical site (risk ratio (RR) 1.32, 95% CI 0.41 to 4.22, P = 0.64, I(2) = 0%). Similarly, no difference in post-operative infection between the use of two 3-dimensional (3D) and standard (2D) miniplates was determined (RR 1.26, 95% CI 0.19 to 8.13, P = 0.81, I(2) = 27%). The included studies involved a small number of participants with a low number of events. AUTHORS' CONCLUSIONS This review illustrates that there is currently inadequate evidence to support the effectiveness of a single approach in the management of mandibular fractures without condylar involvement. The lack of high quality evidence may be explained by clinical diversity, variability in assessment tools used and difficulty in grading outcomes with existing measurement tools. Until high level evidence is available, treatment decisions should continue to be based on the clinician's prior experience and the individual circumstances.