985 resultados para Femoral nerve block


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cervical zygapophysial joint nerve blocks typically are performed with fluoroscopic needle guidance. Descriptions of ultrasound-guided block of these nerves are available, but only one small study compared ultrasound with fluoroscopy, and only for the third occipital nerve. To evaluate the potential usefulness of ultrasound-guidance in clinical practice, studies that determine the accuracy of this technique using a validated control are essential. The aim of this study was to determine the accuracy of ultrasound-guided nerve blocks of the cervical zygapophysial joints using fluoroscopy as control.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To compare analgesic efficacy of preoperative versus postoperative administration of carprofen and to determine, if preincisional mepivacaine epidural anesthesia improves postoperative analgesia in dogs treated with carprofen. STUDY DESIGN: Blind, randomized clinical study. ANIMALS: Dogs with femoral (n=18) or pelvic (27) fractures. METHODS: Dogs were grouped by restricted randomization into 4 groups: group 1 = carprofen (4 mg/kg subcutaneously) immediately before induction of anesthesia, no epidural anesthesia; group 2 = carprofen immediately after extubation, no epidural anesthesia; group 3 = carprofen immediately before induction, mepivacaine epidural block 15 minutes before surgical incision; and group 4 = mepivacaine epidural block 15 minutes before surgical incision, carprofen after extubation. All dogs were administered carprofen (4 mg/kg, subcutaneously, once daily) for 4 days after surgery. Physiologic variables, nociceptive threshold, lameness score, pain, and sedation (numerical rating scale [NRS], visual analog scale [VAS]), plasma glucose and cortisol concentration, renal function, and hemostatic variables were measured preoperatively and at various times after surgery. Dogs with VAS pain scores >30 were administered rescue analgesia. RESULTS: Group 3 and 4 dogs had significantly lower pain scores and amount of rescue analgesia compared with groups 1 and 2. VAS and NRS pain scores were not significantly different among groups 1 and 2 or among groups 3 and 4. There was no treatment effect on renal function and hemostatic variables. CONCLUSIONS: Preoperative carprofen combined with mepivacaine epidural anesthesia had superior postoperative analgesia compared with preoperative carprofen alone. When preoperative epidural anesthesia was performed, preoperative administration of carprofen did not improve postoperative analgesia compared with postoperative administration of carprofen. CLINICAL RELEVANCE: Preoperative administration of systemic opioid agonists in combination with regional anesthesia and postoperative administration of carprofen provides safe and effective pain relieve in canine fracture repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To report clinical features associated with iatrogenic peripheral nerve injury in dogs and cats admitted (1997-2006) to a referral teaching hospital. STUDY DESIGN: Retrospective study. ANIMALS: Dogs (n=18), 9 cats. METHODS: Patients had acute signs of monoparesis attributable to sciatic nerve dysfunction that developed after treatment. Neurologic examination and electrodiagnostic testing were performed. Surgical therapy was used for nerve entrapment and delayed reconstructive surgery used in other cases. RESULTS: Of 27 nerve injuries, 25 resulted from surgery (18 with treatment of pelvic injuries). Iliosacral luxation repair resulted in tibial (4 cats) and peroneal (3 dogs) nerve dysfunction. Other causes were intramedullary pinning of femoral fractures (3), other orthopedic surgery (cemented hip prosthesis [2] and tibial plateau-leveling osteotomy [1]), and perineal herniorrhaphy [1]. Nerve injury occurred after intramuscular injection (1 cat, 1 dog). Immediate surgical treatment was removal of intramedullary nails, extruded cement, or entrapping suture. Delayed nerve transplantation was performed in 2 dogs. Within 1 year, 13 patients recovered completely, clinical improvement occurred in 7, and there was no improvement in 7. Five of the 7 dogs that did not recover had acetabular or ilium fracture. CONCLUSION: Iatrogenic sciatic nerve injury occurred most commonly during treatment of pelvic orthopedic diseases and had a poor prognosis. Clinical variation in sciatic nerve dysfunction in dogs and cats can be explained by species anatomic differences. CLINICAL RELEVANCE: Iatrogenic sciatic nerve injury leads to severely debilitating locomotor dysfunction with an uncertain prognosis for full-functional recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: A previous study of radiofrequency neurotomy of the articular branches of the obturator nerve for hip joint pain produced modest results. Based on an anatomical and radiological study, we sought to define a potentially more effective radiofrequency method. DESIGN: Ten cadavers were studied, four of them bilaterally. The obturator nerve and its articular branches were marked by wires. Their radiological relationship to the bone structures on fluoroscopy was imaged and analyzed. A magnetic resonance imaging (MRI) study was undertaken on 20 patients to determine the structures that would be encountered by the radiofrequency electrode during different possible percutaneous approaches. RESULTS: The articular branches of the obturator nerve vary in location over a wide area. The previously described method of denervating the hip joint did not take this variation into account. Moreover, it approached the nerves perpendicularly. Because optimal coagulation requires electrodes to lie parallel to the nerves, a perpendicular approach probably produced only a minimal lesion. In addition, MRI demonstrated that a perpendicular approach is likely to puncture femoral vessels. Vessel puncture can be avoided if an oblique pass is used. Such an approach minimizes the angle between the target nerves and the electrode, and increases the likelihood of the nerve being captured by the lesion made. Multiple lesions need to be made in order to accommodate the variability in location of the articular nerves. CONCLUSIONS: The method that we described has the potential to produce complete and reliable nerve coagulation. Moreover, it minimizes the risk of penetrating the great vessels. The efficacy of this approach should be tested in clinical trials.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A via de acesso arterial é um importante sítio de complicações após a realização de procedimentos coronários invasivos. Dentre as estratégias para a redução de complicações vasculares, encontra-se estabelecida a eficácia da técnica radial. Os dispositivos de oclusão vascular propiciam maior conforto ao paciente, reduzindo o tempo de hemostasia e repouso no leito. Entretanto, a inconsistência de dados comprovando sua segurança limita sua adoção rotineira como estratégia para redução de complicações vasculares, requerendo evidências de estudos randomizados com metodologia adequada. O objetivo deste estudo foi comparar a incidência de complicações no sítio de punção arterial entre a técnica radial e a técnica femoral com utilização de Angio-Seal em pacientes com síndrome coronariana aguda sem supradesnível do segmento ST submetidos à estratégia invasiva precoce. Trata-se de um ensaio clínico unicêntrico, de não inferioridade, no qual duzentos e quarenta pacientes foram randomizados para a técnica radial ou técnica femoral com utilização de Angio-Seal. O objetivo primário foi a ocorrência de complicações no sítio de punção arterial até 30 dias após o procedimento, incluindo sangramento grave, hematoma >= 5 cm, hematoma retroperitoneal, síndrome compartimental, pseudoaneurisma, fístula arteriovenosa, infecção, isquemia de membro, oclusão arterial, lesão de nervo adjacente ou necessidade de reparo vascular cirúrgico. Em relação às características demográficas e clínicas, houve diferença apenas quanto ao gênero, com presença maior de pacientes do sexo feminino no grupo radial (33,3% versus 20,0%, p=0,020). Não se observaram diferenças entre os grupos quanto ao diagnóstico de admissão, alterações isquêmicas presentes no eletrocardiograma, elevação de marcadores de necrose miocárdica ou escores de risco, bem como quanto à farmacoterapia antitrombótica adjunta e características da intervenção coronária percutânea. A hemostasia foi obtida na totalidade dos procedimentos do grupo radial com a utilização da pulseira compressora seletiva TR Band e em 95% dos procedimentos realizados pela técnica femoral com o Angio-Seal (p=0,029). Exceto pela maior incidência de oclusão arterial no grupo radial comparado ao femoral, não houve diferenças entre os demais desfechos analisados. Segundo o teste de não inferioridade para complicações na via de acesso arterial aos 30 dias, verificou-se que a utilização do Angio-Seal não produziu resultados inferiores ao acesso radial, considerando-se a margem de 15% (12,5% versus 13,3%, diferença -0,83%, IC 95% -9,31 - 7,65, p para não inferioridade <0,001). Os resultados principais deste estudo demonstram que, em uma população de pacientes com diagnóstico de síndrome coronariana aguda sem supradesnível do segmento ST, submetida à estratificação de risco invasiva, a utilização do dispositivo de oclusão vascular Angio-Seal confere ao procedimento efetivado pelo acesso femoral inferioridade na incidência de complicações no sítio de punção arterial aos 30 dias quando comparado ao acesso radial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background and Objectives: Improved ultrasound and needle technology make popliteal sciatic nerve blockade a popular anesthetic technique and imaging to localize the branch point of the common peroneal and posterior tibial components is important because successful blockade techniques vary with respect to injection of the common trunk proximally or separate injections distally. Nerve stimulation, ultrasound, cadaveric and magnetic resonance studies demonstrate variability in distance and discordance between imaging and anatomic examination of the branch point. The popliteal crease and imprecise, inaccessible landmarks render measurement of the branch point variable and inaccurate. The purpose of this study was to use the tibial tuberosity, a fixed bony reference, to measure the distance of the branch point. Method: During popliteal sciatic nerve blockade in the supine position the branch point was identified by ultrasound and the block needle was inserted. The vertical distance from the tibial tuberosity prominence and needle insertion point was measured. Results: In 92 patients the branch point is a mean distance of 12.91 cm proximal to the tibial tuberosity and more proximal in male (13.74 cm) than female patients (12.08 cm). Body height is related to the branch point distance and is more proximal in taller patients. Separation into two nerve branches during local anesthetic injection supports notions of more proximal neural anatomic division. Limitations: Imaging of the sciatic nerve division may not equal its true anatomic separation. Conclusion: Refinements in identification and resolution of the anatomic division of the nerve branch point will determine if more accurate localization is of any clinical significance for successful nerve blockade.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sciatic nerve blockade (SNB) can be performed at several point along its anatomic course. Proximal SNB techniques described include the classic Labat, sacral (Mansur), infragluteal (Raj), and anterior approches Distal SNB techniques include the mid-femoral, posterior and lateral popliteal and mid-tibial approaches. The anatomic region of the lower extramity to be anesthetixzed will determine the appropriate SNB technique to use for the operative procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background. The inferior hypogastric plexus mediates pain sensation through the sympathetic chain for the lower abdominal and pelvic viscera and is thought to be a major structure involved in numerous pelvic and perineal pain syndromes and conditions. Objectives. The objective of this study was to demonstrate the structures affected by an inferior hypogastric plexus blockade utilizing the transsacral approach. Study Design. This is an observational study of fresh cadaver subjects. Setting. The cadaver injections and dissections were performed at the Department of Forensic Sciences and Insurance Medicine, Semmelweis University, Budapest, Hungary after obtaining institutional review board approval. Methods. 5 fresh cadavers underwent inferior hypogastric plexus blockade with radiographic contrast and methylene blue dye injection by the transsacral fluoroscopic technique described by Schultz followed by dissection of the pelvic and perineal structures to localize distribution of the indicator dye. Radiographs demonstrating correct needle localization by contrast spread in the specific tissue plane and photographs of the dye distribution after cadaver dissection were recorded for each subject. Results. In all cadavers the dye spread to the posterior surface of the rectum and the superior hypogastric plexus. The dye also demonstrated distribution to the anterior sacral nerve roots of S1, 2, and 3 with bilateral spread in 3 cadavers and ipsilateral spread in 2 of them. Limitations. The small number of cadaver specimens in this study limits the results and generalization of their clinical significance. Conclusions. Inferior hypogastric plexus blockade by a transsacral approach results in distribution of dye to the anterior sacral nerve roots and superior hypogastric plexus as demonstrated by dye spread in freshly dissected cadavers and not by local anesthetic spread to other pelvic and perineal viscera.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study investigated the actions of the polyether marine toxin Pacific ciguatoxin-1 (P-CTX-1) on neuronal excitability in rat dorsal root ganglion (DRG) neurons using patch-clamp recording techniques. Under current-clamp conditions, bath application of 2-20 nM P-CTX-1 caused a rapid, concentration-dependent depolarization of the resting membrane potential in neurons expressing tetrodotoxin (TTX)-sensitive voltage-gated sodium (Na-v,.) channels. This action was completely suppressed by the addition of 200 nM TTX to the external solution, indicating that this effect was mediated through TTX-sensitive Na-v channels. In addition, P-CTX-1 also prolonged action potential and afterhyperpolarization (AHP) duration. In a subpopulation of neurons, P-CTX-1 also produced tonic action potential firing, an effect that was not accompanied by significant oscillation of the resting membrane potential. Conversely, in neurons expressing TTX-resistant Na-v currents, P-CTX-1 failed to alter any parameter of neuronal excitability examined in this study. Under voltage-clamp conditions in rat DRG neurons, P-CTX-1 inhibited both delayed-rectifier and 'A-type' potassium currents in a dose-dependent manner, actions that Occurred in the absence of alterations to the voltage dependence of activation. These actions appear to underlie the prolongation of the action potential and AHP. and contribute to repetitive firing. These data indicate that a block of potassium channels contributes to the increase in neuronal excitability, associated with a modulation of Na-v. channel gating, observed clinically in response to ciguatera poisoning. (c) 2004 Elsevier Inc. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Little is known about the nature of the calcium channels controlling neurotransmitter release from preganglionic parasympathetic nerve fibres. In the present study, the effects of selective calcium channel antagonists and amiloride were investigated on ganglionic neurotransmission. Conventional intracellular recording and focal extracellular recording techniques were used in rat submandibular and pelvic ganglia, respectively. Excitatory postsynaptic potentials and excitatory postsynaptic currents preceded by nerve terminal impulses were recorded as a measure of acetylcholine release from parasympathetic and sympathetic preganglionic fibres following nerve stimulation. The calcium channel antagonists omega-conotoxin GVIA (N type), nifedipine and nimodipine (L type), omega-conotoxin MVIIC and omega-agatoxin IVA (P/Q type), and Ni2+ (R type) had no functional inhibitory effects on synaptic transmission in both submandibular and pelvic ganglia. The potassium-sparing diuretic, amiloride, and its analogue, dimethyl amiloride, produced a reversible and concentration-dependent inhibition of excitatory postsynaptic potential amplitude in the rat submandibular ganglion. The amplitude and frequency of spontaneous excitatory postsynaptic potentials and the sensitivity of the postsynaptic membrane to acetylcholine were unaffected by amiloride. In the rat pelvic ganglion, amiloride produced a concentration-dependent inhibition of excitatory postsynaptic currents without causing any detectable effects on the amplitude or configuration of the nerve terminal impulse. These results indicate that neurotransmitter release from preganglionic parasympathetic and sympathetic nerve terminals is resistant to inhibition by specific calcium channel antagonists of N-, L-, P/Q- and R-type calcium channels. Amiloride acts presynaptically to inhibit evoked transmitter release, but does not prevent action potential propagation in the nerve terminals, suggesting that amiloride may block the pharmacologically distinct calcium channel type(s) on rat preganglionic nerve terminals. (C) 1999 IBRO. Published by Elsevier Science Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Areal bone mineral density (aBMD) is the most common surrogate measurement for assessing the bone strength of the proximal femur associated with osteoporosis. Additional factors, however, contribute to the overall strength of the proximal femur, primarily the anatomical geometry. Finite element analysis (FEA) is an effective and widely used computerbased simulation technique for modeling mechanical loading of various engineering structures, providing predictions of displacement and induced stress distribution due to the applied load. FEA is therefore inherently dependent upon both density and anatomical geometry. FEA may be performed on both three-dimensional and two-dimensional models of the proximal femur derived from radiographic images, from which the mechanical stiffness may be redicted. It is examined whether the outcome measures of two-dimensional FEA, two-dimensional, finite element analysis of X-ray images (FEXI), and three-dimensional FEA computed stiffness of the proximal femur were more sensitive than aBMD to changes in trabecular bone density and femur geometry. It is assumed that if an outcome measure follows known trends with changes in density and geometric parameters, then an increased sensitivity will be indicative of an improved prediction of bone strength. All three outcome measures increased non-linearly with trabecular bone density, increased linearly with cortical shell thickness and neck width, decreased linearly with neck length, and were relatively insensitive to neck-shaft angle. For femoral head radius, aBMD was relatively insensitive, with two-dimensional FEXI and threedimensional FEA demonstrating a non-linear increase and decrease in sensitivity, respectively. For neck anteversion, aBMD decreased non-linearly, whereas both two-dimensional FEXI and three dimensional FEA demonstrated a parabolic-type relationship, with maximum stiffness achieved at an angle of approximately 15o. Multi-parameter analysis showed that all three outcome measures demonstrated their highest sensitivity to a change in cortical thickness. When changes in all input parameters were considered simultaneously, three and twodimensional FEA had statistically equal sensitivities (0.41±0.20 and 0.42±0.16 respectively, p = ns) that were significantly higher than the sensitivity of aBMD (0.24±0.07; p = 0.014 and 0.002 for three-dimensional and two-dimensional FEA respectively). This simulation study suggests that since mechanical integrity and FEA are inherently dependent upon anatomical geometry, FEXI stiffness, being derived from conventional two-dimensional radiographic images, may provide an improvement in the prediction of bone strength of the proximal femur than currently provided by aBMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To determine the subbasal nerve density and tortuosity at 5 corneal locations and to investigate whether these microstructural observations correlate with corneal sensitivity. Method: Sixty eyes of 60 normal human subjects were recruited into 1 of 3 age groups, group 1: aged ,35 years, group 2: aged 35–50 years, and group 3: aged .50 years. All eyes were examined using slit-lamp biomicroscopy, noncontact corneal esthesiometry, and slit scanning in vivo confocal microscopy. Results: The mean subbasal nerve density and the mean corneal sensitivity were greatest centrally (14,731 6 6056 mm/mm2 and 0.38 6 0.21 millibars, respectively) and lowest in the nasal mid periphery (7850 6 4947 mm/mm2 and 0.49 6 0.25 millibars, respectively). The mean subbasal nerve tortuosity coefficient was greatest in the temporal mid periphery (27.3 6 6.4) and lowest in the superior mid periphery (19.3 6 14.1). There was no significant difference in mean total subbasal nerve density between age groups. However, corneal sensation (P = 0.001) and subbasal nerve tortuosity (P = 0.004) demonstrated significant differences between age groups. Subbasal nerve density only showed significant correlations with corneal sensitivity threshold in the temporal cornea and with subbasal nerve tortuosity in the inferior and nasal cornea. However, these correlations were weak. Conclusions: This study quantitatively analyzes living human corneal nerve structure and an aspect of nerve function. There is no strong correlation between subbasal nerve density and corneal sensation. This study provides useful baseline data for the normal living human cornea at central and mid-peripheral locations