926 resultados para Fecal coliforms
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Aquicultura - FCAV
Resumo:
The objective of this work was to evaluate the microbiological quality and shelf life of Nile tilapia fillets subjected to different smoking methods and storing conditions. Two smoking processes (cold or hot) were used in fillets with or without pigmentation. Products were stored under refrigeration or freezing, and monitored continually for 28 days for evaluation of their shelf life. Frozen fillets were monitored for 146 days for analysis of thiobarbituric acid (TBA) only. Hot- and cold-smoking reduced the coliform quantity, respectively, by 99.78% and 97.80%. Product storage under refrigeration allowed a 99.73% coliform reduction, and storage under freezing reduced them by 99.83%. Fecal coliform values were within the allowed limits. TBA values in fillets reached their maximum on the 14th storage day. TBA values were higher in treatments under refrigeration storage than in those under freezing, as well as in cold-smoked fillets in comparison to the hot-smoked ones. Hot-smoked process, followed by refrigeration storage, is the most adequate technique to ensure quality and a larger shelf life for Nile tilapia fillets, regardless of pigmentation process.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia e Ciência de Alimentos - IBILCE
Resumo:
The objective of this study was to compare the efficiency of washing and trimming broiler carcasses to reduce bacterial contamination. At the poste-visceration site, 100 broiler carcasses were collected during 4 visits to a slaughterhouse in Santa Catarina State, Brazil. Birds were from the same flock, age, and approximately 2.4 kg of weight. Groups were as follows: group 1, with fecal contamination; group 2, without fecal contamination; group 3, with fecal contamination and trimmed; group 4, with fecal contamination and washed; group 5, with fecal contamination, and washed and trimmed. Carcass washings were performed with at least 1.5 L/bird of potable water (0.5 to 1 mg/kg of residual chlorine) at room temperature (20-25 degrees C) using spray cabinets with 44 spray nozzles distributed into 2 chambers (pressure of 2 kgf/cm(2) and 4 kgf/cm(2)). Washed carcasses (trimmed or not) showed significantly (P < 0.05) lower counts of aerobic mesophiles (plate count agar) on the third evaluation, and even lower (P < 0.01) counts for total coliforms (CT) and fecal coliforms (Escherichia coli). Trimmed carcasses showed significantly lower counts (P < 0.05) for plate count agar; however, we observed higher counts for E. coli (P < 0.05). The association of both treatments (washing and trimming) showed significantly higher (P < 0.05) counts for coliforms (CT and E. coli). We can conclude that the washing method is overall more efficient than the trimming method to decontaminate chicken carcasses at the postevisceration site. Hopefully, our findings can help poultry companies to minimize production costs by applying the washing method for carcass decontamination.
Resumo:
We conducted a study of the quality of water distributed by Artesian Well in relation to water supply served by the public for purposes of human consumption of UNESP Campus Guaratinguetá. Two sections of the network were randomly chosen and monitored for 105 days: the stretch of the pipeline started off the Water Treatment Station of the Autonomous Service of Water, Sewage and waste in the Municipality of Guaratinguetá and ended in a point consumption of the Child Family Center, while the section B began at the output of an artesian well and finished in a point of consumption of the Department of Civil Engineering. It is the deterioration of water quality in parts A and B, through comparative analysis of Bicarbonates, Total Hardness, Total Iron, free residual chlorine, pH, Total Residual, Turbidity, Conductivity, Color, Fecal Coliforms and Total Coliforms. Among the observations that can be highlighted: the Total Hardness was found in highest concentration in the extract; for Total Iron significant variations were obtained for both parts, and reduction of this parameter in two points of consumption analyzed, not the expected increase concentration, because the contact of water along the pipe, the CRL showed significant depletion to section A, which can be related to impurities in the water, the presence of biofilm on the walls of pipes, or because this is the stretch of greater extent to be covered by water for pH, this indicated that the water is alkaline and slightly acidic stretch in section B; Turbidity was found for the higher concentration to the passage, and a considerable reduction of this parameter at point consumption due to deposition of particulate matter along the stretch, the conductivity also showed a higher concentration in the extract, as well as an increase in this parameter at the point of consumption. Upon leaving ... (Complete abstract click electronic access below)
Resumo:
Pós-graduação em Ciências Ambientais - Sorocaba
Resumo:
Introduction and Objective: Microorganisms are responsible for multiple infections and pathologies; this is why it is important to control microbes that can be found in the triple syringe used for irrigation in different dental procedures. The aim of this study was to identify cultivable species of microbes (fungus and bacteria) found in some dental units water lines of a private dental clinic from Medellín, Colombia. Materials and Methods: Random samples were taken from 11 chairs from a total of 89; a sample of water of 500ml was collected from the triple syringe of each selected chair. The study aim to search for the presence of total coliforms, filamentous fungi and leavened Results: the average presence of microorganisms was between 40CFU and more of 200 CFU. Microorganisms such as Aeromona salmonicida, Actinobacilus sp and Pseudomona maltophil were isolated. No total coliforms neither fecal coliforms were found. Conclusions: the high levels of contamination suggest that there is a mature biofilm in somewhere of the dental unit water line, but the absence of total and fecalis coliforms suggest that the water had been treated.
Resumo:
The Current work to assess the capacity of water potability samples for that, we used seven different brands of mineral water, bought locally, and also collected seven samples of public drinking fountains located in different places on campus headquarters of the State University of Maringá. The parameters analyzed were presence of fecal and total coliform, turbidity, color and compounds with UV-absorption at 254 nm. On the analysis of coliforms, two brands of mineral water and four samples of drinkers showed presence of total coliform, but no analysis indicated the presence of fecal coliforms. In the turbidity parameter, all samples were within the limits allowed by law, for both cases. No apparent color attribute, two samples of mineral water and a sample of drinking were outside the range required by law. Finally, the determination of UV showed the values of light absorption of each sample at a wavelength of 254nm, however, does not yet exist in Brazil a regulation on this parameter. With such analysis, it was possible to compare the results with current legislation. After these findings, it appears that more stringent hygienic practices should be adopted throughout the processing of mineral water as drinking in public. It is also necessary for greater oversight over the other parameters for determining the quality of water.
Resumo:
Pós-graduação em Microbiologia Agropecuária - FCAV
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The great demand for animal protein was responsible for the increase on the broilers production and hence, the generation of waste from the poultry slaughter was increased as well, which in turn, propelled the development of techniques that allow the reuse and recycling of these wastes. The objective of this study was to evaluate the efficiency of composting on the treatment and recycling of solid waste from poultry slaughterhouse. The solid waste was from a commercial poultry slaughterhouse and was composed of viscera, muscle, fat, bone, blood and feathers that was mixed with a source of carbon, rice husk. Initially, a windrow with a volume of 1.5m(3) was built, and then some parameters were monitored: temperature, total solids (TS), volatile (VS), N, P, K, organic carbon (C), composting organic matter (COC), organic matter resistant to composting (MORC), chemical oxygen demand (COD), mass and volume of the windrow, most probable number (MPN) of total and fecal coliforms, as well as their reductions during the process. The maximum temperature reached in the center of the windrow was 53.3 degrees C (weekly average) since reductions of weight of TS and VS and volume during the pre-composting were 36.1, 44.3 and 23.3%, respectively and during the composting process was 21.8, 23.8 and 4.4%. The low volume reduction can be associated with high concentrations of MORC (40.1%) which can be mainly related to the quality of the carbon source. The process produced satisfactory total reductions of TS, VS and volume that were respectively, 50.1, 57.5 and 26.7%. However reductions were observed in 43% of amount of nitrogen in the final compound. Despite reductions in nitrogen content, composting proved to be an effective method in the treatment of solid waste from poultry slaughterhouse.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)