936 resultados para FUCOSE-RICH POLYSACCHARIDE


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a novel activating mutation (E604K) of the calcium-sensing receptor in a family with autosomal dominant hypocalcemia. Whereas all affected individuals exhibited marked hypocalcemia, some cases with untreated hypocalcemia exhibited seizures in infancy, whereas others were largely asymptomatic from birth into adulthood. The missense mutation E604K (G2182A, GenBank accession no. U20759), which affects an amino acid residue in the C terminus of the cysteine-rich domain of the extracellular head, co-segregated with hypocalcemia in all seven individuals for whom DNA was available. Two unaffected, normocalcemic members of the family did not exhibit the mutation. The molecular impact of the mutation on two key components of the signaling response was assessed in HEK-293 cells transiently transfected with cDNA corresponding to either the wild-type calcium-sensing receptor or the E604K mutation derived by site-directed mutagenesis. There was a significant leftward shift in the concentration response curves for the effects of extracellular Ca2+ on both intracellular Ca2+ mobilization (determined by aequorin luminescence) and MAPK activity (determined by luciferase expression). The C terminus of the cysteine-rich domain of the extracellular head may normally act to suppress receptor activity in the presence of low extracellular Ca2+ concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A stickiness testing device based on the probe tack test has been designed and tested. It was used to perform in situ characterization of drying hemispherical drops with an initial radius 3.5 mm. Tests were carried out in two drying temperatures, 63 and 95 degreesC. Moisture and temperature histories of the drying drops of fructose, honey, sucrose, maltodextrin and sucrose-maltodextrin mixtures were determined. The rates of moisture evaporation of the fructose solution was the fastest while those of the maltodextrin solution was the lowest. A profile reversal was observed when the temperature profiles of these materials were compared. Different modes of failure were observed during the stickiness tests. Pure fructose and honey solutions remained completely sticky and failed cohesively until the end of drying. Pure sucrose solution remained sticky and failed cohesively until complete crystallization occurred. The surface of the maltodextrin drops formed a skin shortly after the start of drying. It exhibited adhesive failure and reached a state of non-adhesion. Addition of maltodextrin significantly altered the stickiness of sucrose solution. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Copyright © 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The '10/90 gap' was first highlighted by the Global Forum for Health Research. It refers to the finding that 90% of worldwide medical research expenditure is targeted at problems affecting only 10% of the world's population. Applying research results from the rich world to the problems of the poor may be a tempting, potentially easy and convenient solution for this gap. This paper had the objective of presenting arguments that such an approach runs the risk of exporting failure. Health interventions that are shown to be effective in the specific context of a Western industrialized setting will not necessarily work in the developing world.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Crossed immunoelectrophoresis (IEC) was used for detection of free and complexed circulating polisaccharide anodic antigen (AgCA) of Schistosoma mansoni in sera of infected hamsters. An attempt was also done to detect AgCA in human sera from patients infected with S. mansoni. The conditions for isolation and detection of complexed AgCA were established. The sensitivity of IEC was increased by incorporation of 2% polyethylene glicol (PEG) to the agarose and by maintaining the system at 4°C during the electrophoretic run. Free AgCA was detected in 12 and the complexed in 30 of the 37 hamsters sera analysed. Correlation between AgCA (free and complexed) and the parasite load was observed. AgCA was not detected, under the experimental conditions used, in human sera from 7 patients in the acute and 23 in the chronic phase of infection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two sheep antisera, one of which raised against polysaccharide (Po) and other against protein (Pt) components of Schistosoma mansoni adult worms, were assessed by ELISA for their ability to detect circulating parasite antigens in patients with different clinical forms of chronic schistosomiasis mansoni. The former antiserum detected parasite antigens in liver granulomata and the latter in renal glomeruli from schistosomiasis patients and mice experimentally infected with S. mansoni. In general, the levels and/or positivity rate of circulating antigens and specific IgG antibodies were significantly higher in patients with hepatointestinal (HI) and hepatosplenic (HS) forms than in mild intestinal (I) forms. An association between Po antigens and clinical features of the disease was observed, as the level of these antigens was low (137 ng/ml) as well as the positivity rate (7.9%) in patients with I forms; values that were intermediate (593 ng/ml and 33.3%) in those with HI forms, and high (1.563 ng/ml and 50.0%) in more severe HS forms. The Pt antigens were detected in the studied clinical forms not differing statistically but, the positivity rate was significantly higher in HS forms comparatively to I forms. The antisera studied revealed distinct circulating antigen profiles, and the prognostic value of Po and Pt antigens was suggested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dot-enzyme-linked immunosorbent assay (Dot-ELISA) for pneumococcal antigen detection was standardized in view of the need for a rapid and accurate immunodiagnosis of acute pneumococcal pneumonia. A total of 442 pleural fluid effusion samples (PFES) from children with clinical and laboratory diagnoses of acute bacterial pneumonia, plus 38 control PFES from tuberculosis patients and 20 negative control serum samples from healthy children were evaluated by Dot-ELISA. The samples were previously treated with 0.1 M EDTA pH 7.5 at 90°C for 10 min and dotted on nitrocellulose membrane. Pneumococcal omniserum diluted at 1:200 was employed in this assay for antigen detection. When compared with standard bacterial culture, counterimmunoelectrophoresis and latex agglutination techniques, the Dot-ELISA results showed relative indices of 0.940 to sensitivity, 0.830 to specificity and 0.760 to agreement. Pneumococcal omniserum proved to be an optimal polyvalent antiserum for the detection of pneumococcal antigen by Dot-ELISA. Dot-ELISA proved to be a practical alternative technique for the diagnosis of pneumococcal pneumonia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Serum samples from 242 HIV-positive persons were studied for the detection of capsular polysaccha-ride antigen of Cryptococcus neoformans; 193 of these patients presented less than 300 CD4+ cells/µl of blood and 49 patients had more than 300 CD4+ cells/µl. None of them had symptoms or signs characteristic of cryptococcosis. The capsular antigen of C. neofarmans was detected by latex agglutination technique with pronase pre-treatment (IMMY, Crypto-Latex Antigen Detection System, Immunomycologics Inc., OK, USA); in 61% of the samples, ELISA technique was also used (Premier, Cryptococcal Antigen, Meridian Diagnostic Inc., Cincinatti, Oh, USA). The comparative study of both methods showed that the results obtained were similar in 96.9% of the cases. The capsular antigen was detected in 13 out of 193 (6.7%) patients with less than 300 CD4+ cells/µl. Cryptococcosis was confirmed mycologically in 3 of these 13 cases (23%) by the isolation of C. neoformans in CSF or blood cultures. Three patients, who had presented negative results of both tests for capsular antigen, suffered disseminated cryptococcosis 4 to 8 months later. The predictive diagnostic value of capsular antigen detection of C. neoformans seems tobe low and we believe that it should not be done routinely in asymptomatic HIV-positive persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work was planned by taking into account all the knowledge accumulated from the immunological study of paracoccidioidomycosis. It aimed at comparing a polysaccharide antigen from Histoplasma capsulatum to a classic histoplasmin with the help of intradermal tests of delayed type of hypersensitivity. Tests were applied to 115 individuals in Santo Amaro, a town in the state of São Paulo. Positive results using classic histoplasmin were obtained in 46.0% cases whereas positive results using the polysaccharide antigen at its hightest concentration were obtained in 51.30% cases. The major conclusion in this investigation is that it is possible to use the polysaccharide antigen as histoplasmin instead of the filtrate antigen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Currently, a learning management system (LMS) plays a central role in any e-learning environment. These environments include systems to handle the pedagogic aspects of the teaching–learning process (e.g. specialized tutors, simulation games) and the academic aspects (e.g. academic management systems). Thus, the potential for interoperability is an important, although over looked, aspect of an LMS. In this paper, we make a comparative study of the interoperability level of the most relevant LMS. We start by defining an application and a specification model. For the application model, we create a basic application that acts as a tool provider for LMS integration. The specification model acts as the API that the LMS should implement to communicate with the tool provider. Based on researches, we select the Learning Tools Interoperability (LTI) from IMS. Finally, we compare the LMS interoperability level defined as the effort made to integrate the application on the study LMS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Work Project, presented as part of the requirements for the Award of a Masters Degree in Economics from the NOVA – School of Business and Economics

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Fucose-Mannose Ligand (FML) of Leishmania donovani is a complex glycoproteic fraction. Its potential use as a tool for diagnosis of human visceral leishmaniasis was tested with human sera from Natal, Rio Grande do Norte, Brazil. The FML-ELISA test, showed 100% sensitivity and 96% specificity, identifying patients with overt kala-azar (p < 0.001, when compared to normal sera), and subjects with subclinical infection. More than 20% apparently healthy subjects with positive reaction to FML developed overt kala-azar during the following 10 months. In the screening of human blood donnors, a prevalence of 5% of sororeactive subjects was detected, attaining 17% in a single day. The GP36 glycoprotein of FHL is specifically reconized by human kala-azar sera. The immunoprotective effect of FML on experimental L. donovanii infection was tested in swiss albino mice. The protection scheemes included three weekly doses of FML, supplemented or not with saponin by the subcutaneous or intraperitoneal routes and challenge with 2x 10(7) amastigotes of Leishmania donovani. An enhancement of 80.0 % in antibody response (p<0.001) and reduction of 85.5 % parasite liver burden (p<0.001) was detected in animals immunized with FML saponin, unrespectivety of the immunization route.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain the Ph.D degree in Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: During histoplasmosis, Histoplasma capsulatum soluble antigens (CFAg) can be naturally released by yeast cells. Because CFAg can be specifically targeted during infection, in the present study we investigated CFAg release in experimental murine histoplasmosis, and evaluated the host humoral immune response against high-molecular-mass antigens (hMMAg. >150 kDa), the more immunogenic CFAg fraction. METHODS: Mice were infected with 2.2x10(4) H. capsulatum IMT/HC128 yeast cells. The soluble CFAg, IgG anti-CFAg, IgG anti-hMMAg, and IgG-hMMAg circulating immune complexes (CIC) levels were determined by enzymelinked immunosorbent assay, at days 0, 7, 14, and 28 post-infection. RESULTS: We observed a progressive increase in circulating levels of CFAg, IgG anti-CFAg, IgG anti-hMMAg, and IgG-hMMAg CIC after H. capsulatum infection. The hMMAg showed a high percentage of carbohydrates and at least two main immunogenic components. CONCLUSIONS: We verified for the first time that hMMAg from H. capsulatum IMT/HC128 strain induce humoral immune response and lead to CIC formation during experimental histoplasmosis.