119 resultados para FIB
Resumo:
This study aimed to assess the sanitary quality of water, and wet and dry sand from three beaches located in the South Coast region of Sao Paulo State, Brazil, selected taking into account the frequency of tourists and the water quality (good, fair and poor). Thirty-six water samples each of wet and dry sand and seawater were collected monthly over a period of one year and analyzed for fecal indicator bacteria (FIB: thermotolerant coliforms, Escherichia coli, and enterococci), presumptive Staphylococcus aureus, Pseudomonas aeruginosa, Candida albicans and dermatophytes. The results revealed FIB concentrations more elevated in dry sand followed by wet sand and water. P. aeruginosa and presumptive S. aureus were detected with a similar frequency in water and sand samples, but maximum concentrations and geometric means were higher in dry sand. C. albicans was detected only in water samples whereas the dermatophyte Microsporum sp. was isolated exclusively from dry and wet sand samples. This evaluation showed also that the environment had a significant influence on P. aeruginosa but not on presumptive S. aureus concentrations. According to threshold values proposed in the literature for E. coli and enterococci dry sand densities, none of the beaches would be considered of sufficient quality for recreational activities.
Resumo:
L’utilizzo degli FRP (Fiber Reinforced Polymer) nel campo dell’ingegneria civile riguarda essenzialmente il settore del restauro delle strutture degradate o danneggiate e quello dell’adeguamento statico delle strutture edificate in zona sismica; in questi settori è evidente la difficoltà operativa alla quale si va in contro se si volessero utilizzare tecniche di intervento che sfruttano materiali tradizionali. I motivi per cui è opportuno intervenire con sistemi compositi fibrosi sono: • l’estrema leggerezza del rinforzo, da cui ne deriva un incremento pressoché nullo delle masse sismiche ed allo stesso tempo un considerevole aumento della duttilità strutturale; • messa in opera senza l’ausilio di particolari attrezzature da un numero limitato di operatori, da cui un minore costo della mano d’opera; • posizionamento in tempi brevi e spesso senza interrompere l’esercizio della struttura. Il parametro principale che definisce le caratteristiche di un rinforzo fibroso non è la resistenza a trazione, che risulta essere ben al di sopra dei tassi di lavoro cui sono soggette le fibre, bensì il modulo elastico, di fatti, più tale valore è elevato maggiore sarà il contributo irrigidente che il rinforzo potrà fornire all’elemento strutturale sul quale è applicato. Generalmente per il rinforzo di strutture in c.a. si preferiscono fibre sia con resistenza a trazione medio-alta (>2000 MPa) che con modulo elastico medio-alto (E=170-250 GPa), mentre per il recupero degli edifici in muratura o con struttura in legno si scelgono fibre con modulo di elasticità più basso (E≤80 GPa) tipo quelle aramidiche che meglio si accordano con la rigidezza propria del supporto rinforzato. In questo contesto, ormai ampliamente ben disposto nei confronti dei compositi, si affacciano ora nuove generazioni di rinforzi. A gli ormai “classici” FRP, realizzati con fibre di carbonio o fibre di vetro accoppiate a matrici organiche (resine epossidiche), si affiancano gli FRCM (Fiber Reinforced Cementitious Matrix), i TRM (Textile Reinforced Mortars) e gli SRG (Steel Reinforced Grout) che sfruttano sia le eccezionali proprietà di fibre di nuova concezione come quelle in PBO (Poliparafenilenbenzobisoxazolo), sia un materiale come l’acciaio, che, per quanto comune nel campo dell’edilizia, viene caratterizzato da lavorazioni innovative che ne migliorano le prestazioni meccaniche. Tutte queste nuove tipologie di compositi, nonostante siano state annoverate con nomenclature così differenti, sono però accomunate dell’elemento che ne permette il funzionamento e l’adesione al supporto: la matrice cementizia
Resumo:
L’approccio performance-based nell’Ingegneria sismica è una metodologia di progetto che tiene esplicitamente in conto la performance dell’edificio tra i criteri progettuali. Nell’ambito dei metodi PBEE (Performance-Based Earthquake Engineering) di seconda generazione, quello proposto dal PEER (Pacific Earthquake Engineering Research Center) risulta essere il più diffuso. In esso la performance dell’edificio oggetto di studio viene valutata in termini quantitativi secondo le 3D’s (dollars, deaths, downtime – soldi, decessi, inutilizzo), quantità di notevole interesse per l’utente finale. Il metodo si compone di quattro step, indipendenti tra loro fino alla sintesi finale. Essi sono: l’analisi di pericolosità, l’analisi strutturale, l’analisi di danno, l’analisi delle perdite o di loss. Il risultato finale è la curva di loss, che assegna ad ogni possibile perdita economica conseguente all’evento sismico una probabilità di superamento nell’arco temporale di riferimento. Dopo la presentazione del metodo PEER, si è provveduto ad una sua applicazione su di un caso di studio, nella fattispecie un telaio piano di quattro campate, multipiano, in calcestruzzo armato, costruito secondo le norme del ’92. Per l’analisi di pericolosità si è fatto ricorso alle mappe di pericolosità disponibili sul sito INGV, mentre per l’analisi strutturale si è utilizzato il software open-source OpenSees. Le funzioni di fragilità e quelle di loss sono state sviluppate facendo riferimento alla letteratura scientifica, in particolare il bollettino Fib numero 68 “Probabilistic performance-based seismic design”. In questa sede ci si è concentrati unicamente sulla stima delle perdite economiche, tralasciando le altre due variabili decisionali. Al termine del procedimento si è svolta un’analisi di sensitività per indagare quali parametri influenzino maggiormente la curva di loss. Data la curva di pericolosità, il legame EDP(IM) e la deformazione ultima a collasso risultano essere i più rilevanti sul risultato dell’analisi.
Resumo:
We have realized a Data Acquisition chain for the use and characterization of APSEL4D, a 32 x 128 Monolithic Active Pixel Sensor, developed as a prototype for frontier experiments in high energy particle physics. In particular a transition board was realized for the conversion between the chip and the FPGA voltage levels and for the signal quality enhancing. A Xilinx Spartan-3 FPGA was used for real time data processing, for the chip control and the communication with a Personal Computer through a 2.0 USB port. For this purpose a firmware code, developed in VHDL language, was written. Finally a Graphical User Interface for the online system monitoring, hit display and chip control, based on windows and widgets, was realized developing a C++ code and using Qt and Qwt dedicated libraries. APSEL4D and the full acquisition chain were characterized for the first time with the electron beam of the transmission electron microscope and with 55Fe and 90Sr radioactive sources. In addition, a beam test was performed at the T9 station of the CERN PS, where hadrons of momentum of 12 GeV/c are available. The very high time resolution of APSEL4D (up to 2.5 Mfps, but used at 6 kfps) was fundamental in realizing a single electron Young experiment using nanometric double slits obtained by a FIB technique. On high statistical samples, it was possible to observe the interference and diffractions of single isolated electrons traveling inside a transmission electron microscope. For the first time, the information on the distribution of the arrival time of the single electrons has been extracted.
Resumo:
In this thesis, elemental research towards the implantation of a diamond-based molecular quantum computer is presented. The approach followed requires linear alignment of endohedral fullerenes on the diamond C(100) surface in the vicinity of subsurface NV-centers. From this, four fundamental experimental challenges arise: 1) The well-controlled deposition of endohedral fullerenes on a diamond surface. 2) The creation of NV-centers in diamond close to the surface. 3) Preparation and characterization of atomically-flat diamondsurfaces. 4) Assembly of linear chains of endohedral fullerenes. First steps to overcome all these challenges were taken in the framework of this thesis. Therefore, a so-called “pulse injection” technique was implemented and tested in a UHV chamber that was custom-designed for this and further tasks. Pulse injection in principle allows for the deposition of molecules from solution onto a substrate and can therefore be used to deposit molecular species that are not stable to sublimation under UHV conditions, such as the endohedral fullerenes needed for a quantum register. Regarding the targeted creation of NV-centers, FIB experiments were carried out in cooperation with the group of Prof. Schmidt-Kaler (AG Quantum, Physics Department, Johannes Gutenberg-Universität Mainz). As an entry into this challenging task, argon cations were implanted into (111) surface-oriented CaF2 crystals. The resulting implantation spots on the surface were imaged and characterized using AFM. In this context, general relations between the impact of the ions on the surface and their valency or kinetic energy, respectively, could be established. The main part of this thesis, however, is constituted by NCAFM studies on both, bare and hydrogen-terminated diamond C(100) surfaces. In cooperation with the group of Prof. Dujardin (Molecular Nanoscience Group, ISMO, Université de Paris XI), clean and atomically-flat diamond surfaces were prepared by exposure of the substrate to a microwave hydrogen plasma. Subsequently, both surface modifications were imaged in high resolution with NC-AFM. In the process, both hydrogen atoms in the unit cell of the hydrogenated surface were resolved individually, which was not achieved in previous STM studies of this surface. The NC-AFM images also reveal, for the first time, atomic-resolution contrast on the clean, insulating diamond surface and provide real-space experimental evidence for a (2×1) surface reconstruction. With regard to the quantum computing concept, high-resolution NC-AFM imaging was also used to study the adsorption and self-assembly potential of two different kinds of fullerenes (C60 and C60F48) on aforementioned diamond surfaces. In case of the hydrogenated surface, particular attention was paid to the influence of charge transfer doping on the fullerene-substrate interaction and the morphology emerging from self-assembly. Finally, self-assembled C60 islands on the hydrogen-terminated diamond surface were subject to active manipulation by an NC-AFM tip. Two different kinds of tip-induced island growth modes have been induced and were presented. In conclusion, the results obtained provide fundamental informations mandatory for the realization of a molecular quantum computer. In the process it was shown that NC-AFM is, under proper circumstances, a very capable tool for imaging diamond surfaces with highest resolution, surpassing even what has been achieved with STM up to now. Particular attention was paid to the influence of transfer doping on the morphology of fullerenes on the hydrogenated diamond surface, revealing new possibilities for tailoring the self-assembly of molecules that have a high electron affinity.
Resumo:
In the current study, we analyze the effectiveness of an organosilane compound, 3-mercapto-propyl-tri-methoxy-silane (abbreviated PropS-SH), in the corrosion protection of fire-gilded bronzes. Firstly, the coating was applied on as-gilded bronze. Subsequently, it was also applied on pre-patinated bronze, because the substrate on which protective coatings are applied in real conservation interventions are corroded artifacts (cleaning procedures never remove all the corrosion products). Aiming to obtain results that simulate the situation of real artifacts, a dropping test that simulates outdoor exposure in runoff conditions (unsheltered areas of monuments) was employed in order to prepatinate the gilded bronze samples, which are the substrate for applying the protective coating. The preparation of the samples by applying the protective coating was performed in collaboration with the Corrosion Studies Centre “Aldo Daccò” from Ferrara University. After the artificial exposure cycles the samples underwent investigations through a variety of spectroscopic methods including SEM, Raman, FIB, AAS and color measurements. In order to evaluate the possible removal of the organosilane coating, protected samples were subjected to laser cleaning tests and characterized by SEM/EDS so as to assess the changes in composition and morphology of the treated surfaces. The laser cleaning treatment was performed at the Institute of Applied Physics “Nello Carrara” (CNR Sesto Fiorentino (FI)). The morphology and chemical composition of the samples was observed before and after the operation in order to obtain information about the fluence and type of laser which are best suited to the removal of this type of coating.
Resumo:
We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.
Resumo:
Aim To analyze alcohol use, clinical data and laboratory parameters that may affect FIB-4, an index for measuring liver fibrosis, in HCV-monoinfected and HCV/HIV-coinfected drug users. Patients and Methods Patients admitted for substance abuse treatment between 1994 and 2006 were studied. Socio-demographic data, alcohol and drug use characteristics and clinical variables were obtained through hospital records. Blood samples for biochemistry, liver function tests, CD4 cell count, and serology of HIV and HCV infection were collected at admission. Multivariate linear regression was used to analyze the predictors of FIB-4 increase. Results A total of 472 (83% M, 17% F) patients were eligible. The median age at admission was 31 years (Interquartile range (IQR) 27–35 years), and the median duration of drug use was 10 years (IQR 5.5–15 years). Unhealthy drinking (>50 grams/day) was reported in 32% of the patients. The FIB-4 scores were significantly greater in the HCV/HIV-coinfected patients (1.14, IQR 0.76–1.87) than in the HCV-monoinfected patients (0.75, IQR 0.56–1.11) (p<0.001). In the multivariate analysis, unhealthy drinking (p = 0.034), lower total cholesterol (p = 0.042), serum albumin (p<0.001), higher GGT (p<0.001) and a longer duration of addiction (p = 0.005) were independently associated with higher FIB-4 scores in the HCV-monoinfected drug users. The effect of unhealthy drinking on FIB-4 scores disappeared in the HCV/HIV-coinfected patients, whereas lower serum albumin (p<0.001), a lower CD4 cell count (p = 0.006), higher total bilirubin (p<0.001) and a longer drug addiction duration (p<0.001) were significantly associated with higher FIB-4 values. Conclusions Unhealthy alcohol use in the HCV-monoinfected patients and HIV-related immunodeficiency in the HCV/HIV-coinfected patients are important risk factors associated with liver fibrosis in the respective populations.
Resumo:
BACKGROUND: The effect of alcohol on liver disease in HIV infection has not been well characterized. METHODS: We performed a cross-sectional multivariable analysis of the association between lifetime alcohol use and liver fibrosis in a longitudinal cohort of HIV-infected patients with alcohol problems. Liver fibrosis was estimated with 2 noninvasive indices, "FIB-4," which includes platelets, liver enzymes, and age; and aspartate aminotransferase/platelet ratio index ("APRI"), which includes platelets and liver enzymes. FIB-4 <1.45 and APRI <0.5 defined the absence of liver fibrosis. FIB-4 >3.25 and APRI >1.5 defined advanced liver fibrosis. The main independent variable was lifetime alcohol consumption (<150 kg, 150 to 600 kg, >600 kg). RESULTS: Subjects (n = 308) were 73% men, mean age 43 years, 49% with hepatitis C virus (HCV) infection, 60% on antiretroviral therapy, 49% with an HIV RNA load <1,000 copies/ml, and 18.7% with a CD4 count <200 cells/mm(3) . Forty-five percent had lifetime alcohol consumption >600 kg, 32.7% 150 to 600 kg, and 22.3% <150 kg; 33% had current heavy alcohol use, and 69% had >9 years of heavy episodic drinking. Sixty-one percent had absence of liver fibrosis and 10% had advanced liver fibrosis based on FIB-4. In logistic regression analyses, controlling for age, gender, HCV infection, and CD4 count, no association was detected between lifetime alcohol consumption and the absence of liver fibrosis (FIB-4 <1.45) (adjusted odds ratio [AOR] = 1.12 [95% CI: 0.25 to 2.52] for 150 to 600 kg vs. <150 kg; AOR = 1.11 [95% CI: 0.52 to 2.36] for >600 kg vs. <150 kg; global p = 0.95). Additionally, no association was detected between lifetime alcohol use and advanced liver fibrosis (FIB-4 >3.25). Results were similar using APRI, and among those with and without HCV infection. CONCLUSIONS: In this cohort of HIV-infected patients with alcohol problems, we found no significant association between lifetime alcohol consumption and the absence of liver fibrosis or the presence of advanced liver fibrosis, suggesting that alcohol may be less important than other known factors that promote liver fibrosis in this population.
Resumo:
The single electron transistor (SET) is a charge-based device that may complement the dominant metal-oxide-semiconductor field effect transistor (MOSFET) technology. As the cost of scaling MOSFET to smaller dimensions are rising and the the basic functionality of MOSFET is encountering numerous challenges at dimensions smaller than 10nm, the SET has shown the potential to become the next generation device which operates based on the tunneling of electrons. Since the electron transfer mechanism of a SET device is based on the non-dissipative electron tunneling effect, the power consumption of a SET device is extremely low, estimated to be on the order of 10^-18J. The objectives of this research are to demonstrate technologies that would enable the mass produce of SET devices that are operational at room temperature and to integrate these devices on top of an active complementary-MOSFET (CMOS) substrate. To achieve these goals, two fabrication techniques are considered in this work. The Focus Ion Beam (FIB) technique is used to fabricate the islands and the tunnel junctions of the SET device. A Ultra-Violet (UV) light based Nano-Imprint Lithography (NIL) call Step-and-Flash- Imprint Lithography (SFIL) is used to fabricate the interconnections of the SET devices. Combining these two techniques, a full array of SET devices are fabricated on a planar substrate. Test and characterization of the SET devices has shown consistent Coulomb blockade effect, an important single electron characteristic. To realize a room temperature operational SET device that function as a logic device to work along CMOS, it is important to know the device behavior at different temperatures. Based on the theory developed for a single island SET device, a thermal analysis is carried out on the multi-island SET device and the observation of changes in Coulomb blockade effect is presented. The results show that the multi-island SET device operation highly depends on temperature. The important parameters that determine the SET operation is the effective capacitance Ceff and tunneling resistance Rt . These two parameters lead to the tunneling rate of an electron in the SET device, Γ. To obtain an accurate model for SET operation, the effects of the deviation in dimensions, the trap states in the insulation, and the background charge effect have to be taken into consideration. The theoretical and experimental evidence for these non-ideal effects are presented in this work.
Resumo:
Background: We investigated changes in biomarkers of liver disease in HIV–HCV-coinfected individuals during successful combination antiretroviral therapy (cART) compared to changes in biomarker levels during untreated HIV infection and to HIV-monoinfected individuals. Methods: Non-invasive biomarkers of liver disease (hyaluronic acid [HYA], aspartate aminotransferase-to-platelet ratio index [APRI], Fibrosis-4 [FIB-4] index and cytokeratin-18 [CK-18]) were correlated with liver histology in 49 HIV–HCV-coinfected patients. Changes in biomarkers over time were then assessed longitudinally in HIV–HCV-coinfected patients during successful cART (n=58), during untreated HIV-infection (n=59), and in HIV-monoinfected individuals (n=17). The median follow-up time was 3.4 years on cART. All analyses were conducted before starting HCV treatment. Results: Non-invasive biomarkers of liver disease correlated significantly with the histological METAVIR stage (P<0.002 for all comparisons). The mean ±sd area under the receiver operating characteristic (AUROC) curve values for advanced fibrosis (≥F3 METAVIR) for HYA, APRI, FIB-4 and CK-18 were 0.86 ±0.05, 0.84 ±0.08, 0.80 ±0.09 and 0.81 ±0.07, respectively. HYA, APRI and CK-18 levels were higher in HIV–HCV-coinfected compared to HIV-monoinfected patients (P<0.01). In the first year on cART, APRI and FIB-4 scores decreased (-35% and -33%, respectively; P=0.1), mainly due to the reversion of HIV-induced thrombocytopaenia, whereas HYA and CK-18 levels remained unchanged. During long-term cART, there were only small changes (<5%) in median biomarker levels. Median biomarker levels changed <3% during untreated HIV-infection. Overall, 3 patients died from end-stage liver disease, and 10 from other causes. Conclusions: Biomarkers of liver disease highly correlated with fibrosis in HIV–HCV-coinfected individuals and did not change significantly during successful cART. These findings suggest a slower than expected liver disease progression in many HIV–HCV-coinfected individuals, at least during successful cART.
Resumo:
Although AST-to-platelet ratio index (APRI) and FIB-4 have been compared with liver biopsy in patients with hepatitis C virus (HCV), hepatitis B virus (HBV), HIV/HCV co-infection, and HIV/HBV co-infection, Johannessen and Lemoine stress that they have not been validated in HIV mono-infected populations in SSA. However, this is unlikely to occur because liver biopsy does not play a role in HIV management and the procedure carries its own risks for complication. Clinicians using APRI and FIB-4 in this setting should be aware of this limitation and should interpret test results in the context of each patient's clinical scenario. This article is protected by copyright. All rights reserved.
Resumo:
BACKGROUND: Hyperosmolar therapy, using either mannitol or hypertonic saline (HTS), is considered the treatment of choice for intracranial hypertension. However, hyperosmolar agents may impair coagulation and platelet function, limiting their use in patients at risk for hemorrhage. Despite this, studies evaluating the effects of mannitol compared to other hyperosmolar agents in dogs are largely lacking. The aim of this study was to compare the in vitro effects on global hemostasis and platelet function of 20 % mannitol and 3 % HTS on canine blood. METHODS: Citrated whole blood from 15 healthy dogs was diluted with 0.9 % saline, 20 % mannitol and 3 % HTS in ratios of 1:16 and 1:8. Rotational thromboelastometry (ROTEM) was used to assess clotting time (CT), clot formation time (CFT) and maximal clot firmness (MCF) following extrinsic activation (Ex-tem) and after platelet inhibition (Fib-tem). A platelet function analyzer (PFA-100) was used to assess closure time (CtPFA). RESULTS: No significant differences were observed between untreated whole blood and samples diluted with saline. Samples diluted with both mannitol and HTS were hypocoagulable compared to untreated whole blood samples. At a dilution of 1:16, no significant differences were found between any measured parameter in samples diluted with saline compared to mannitol or HTS. At a 1:8 dilution, CtPFA was prolonged in samples diluted with mannitol and HTS compared to saline, and CtPFA was prolonged more with mannitol than HTS. Ex-tem CT was increased at a 1:8 dilution with mannitol compared to HTS. Ex-tem CFT was prolonged at a 1:8 dilution with both agents compared to saline, and was prolonged more with mannitol than HTS. Ex-tem MCF was reduced at a 1:8 dilution with both agents compared to saline. DISCUSSION AND CONCLUSIONS: Data in this study indicate that both mannitol and HTS affect canine platelet function and whole blood coagulation in vitro in a dose-dependent fashion. The most pronounced effects were observed after high dilutions with mannitol, which impaired platelet aggregation, clot formation time, clot strength, and fibrin formation significantly more than HTS. Further in vivo studies are necessary before recommendations can be made
Resumo:
OBJECTIVES To evaluate the diagnostic performance of seven non-invasive tests (NITs) of liver fibrosis and to assess fibrosis progression over time in HIV/HCV co-infected patients. METHODS Transient elastography (TE) and six blood tests were compared to histopathological fibrosis stage (METAVIR). Participants were followed over three years with NITs at yearly intervals. RESULTS Area under the receiver operating characteristic curve (AUROC) for significant fibrosis (> = F2) in 105 participants was highest for TE (0.85), followed by FIB-4 (0.77), ELF-Test (0.77), APRI (0.76), Fibrotest (0.75), hyaluronic acid (0.70), and Hepascore (0.68). AUROC for cirrhosis (F4) was 0.97 for TE followed by FIB-4 (0.91), APRI (0.89), Fibrotest (0.84), Hepascore (0.82), ELF-Test (0.82), and hyaluronic acid (0.79). A three year follow-up was completed by 87 participants, all on antiretroviral therapy and in 20 patients who completed HCV treatment (9 with sustained virologic response). TE, APRI and Fibrotest did not significantly change during follow-up. There was weak evidence for an increase of FIB-4 (mean increase: 0.22, p = 0.07). 42 participants had a second liver biopsy: Among 38 participants with F0-F3 at baseline, 10 were progessors (1-stage increase in fibrosis, 8 participants; 2-stage, 1; 3-stage, 1). Among progressors, mean increase in TE was 3.35 kPa, in APRI 0.36, and in FIB-4 0.75. Fibrotest results did not change over 3 years. CONCLUSION TE was the best NIT for liver fibrosis staging in HIV/HCV co-infected patients. APRI-Score, FIB-4 Index, Fibrotest, and ELF-Test were less reliable. Routinely available APRI and FIB-4 performed as good as more expensive tests. NITs did not change significantly during a follow-up of three years, suggesting slow liver disease progression in a majority of HIV/HCV co-infected persons on antiretroviral therapy.
Resumo:
About 200 volcanic ash layers were recovered during DSDP Leg 57. The volcanic glass in some of these layers was investigated petrographically and chemically in this study. Volcanic glass is mainly rhyolitic and/or rhyodacitic in chemical composition, and its refractive index ranges from 1.496 to 1.529. Some volcanic ash layers consist of multiple grains of different chemical compositions. All the volcanic glass belongs to the tholeiitic and the calc-alkalic volcanic rock series, in SiO2-(Na2O + K2O) diagram and FeO*/MgO-SiO2 diagram. We correlated successfully three volcanic ash layers from the standpoint of chemical composition and biostratigraphy. Hydration of volcanic glass from Leg 57 is less intense than in other DSDP cores.