920 resultados para Evaluation of different sources of carbohydrates


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study evaluated muscle, adipose and bone tissue growth in young Mediterranean buffaloes slaughtered with different weights. Twenty eight non-castrated males, approximately 14 months old and 330 kilos, were distributed in four experimental and one control groups. Received the same diet during a non-fixed period and when reached the pre-established weights (450 kg, 480 kg, 510 kg, 540 kg) were fasted for 16 hours and slaughtered. NRC 1996, level 2, ruminal simulation program for non-castrated animals with a daily weight gain of 1.40 kg determined percentage composition of experimental diet (dry matter): coast cross hay (20.6%), corn silage (7.8%), cotton seed (8.2%), humid corn silage (46%) and commercial mineral concentrate (17.4%), representing 13% of crude protein and 2,68% of metabolizable energy (Mcal/kg). Feed was offered ad libitum twice daily. Slaughter of control group occurred after 30 days of an adaptation period. The other ones were weighted each 28 days until reached pre-established weight. Carcasses were chilled for 18 hours under -5 degrees C. Ninth, 10 degrees and 11 degrees ribs of the half left carcass were submitted to HH section and according to the statistical regression analysis (SAS, 1996), allometric coefficient value was negative (b<1) demonstrating the early growth of muscle in relation to empty carcass weight.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The buffalo is a domestic animal species of growing world-wide importance. Research to improve genetic improvement programs is important to maintain the productivity of buffalo. The objective this research was to evaluate the growth of Brazilian buffalo to two years of age with different growth curves. Growth curves consolidate the information contained in the weight-age data into three or four biologically meaningful parameters. The data included 31,452 weights at birth and 120, 205, 365, 550 and 730 days of buffalo (n = 5,178) raised on pasture without supplementation. Logistic, Gompertz, quadratic logarithmic, and linear hyperbolic curves (designated L, G, QL, and LH, respectively) were fitted to the data by using proc NUN of SAS (SAS Institute, Inc., Cary, NC, USA). The parameters estimates for L [WT= A * (((1 + exp (-k * AGE)))**-m)] were A = 865.1 +/- 5.42; k= 0.0028 +/- 0.00002; M= 3.808 +/- 0.007; R(2) = 0.95. For G [WT= A * exp (-b * exp (-k * age)] the parameters estimates were A= 967.6 +/- 7.23; k = 0.00217 +/- 0.000015; b = -2.8152 +/- 0.00532. For QL [WT= A + b*age + k*(age*age) + m*log (age)] parameters estimates were A= 37.41 +/- 0.48; k= 0.00019 +/- 6.4E(-6); b= 0.539 +/- 0.006; m= 2.32 +/- 0.23; R(2)=0.96. For LH [WT= A + b*AGE + k*(1/AGE)] the parameters estimates were A= 23.15 +/- 0.44; k=15.16 +/- 0.66; b= 0.707 +/- 0.001; R(2)= 0.96. Each of these curves fit these data equally well and could be used for characterizing growth to two years in beef buffalo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objectives of the present study were to estimate the population of the normal and degenerated preantral follicles of buffaloes in different reproductive phases and to classify the different types of degeneration of ovarian preantral follicles. For this, 18 ovaries were divided in three groups: prepubertal, non pregnat and pregnant adult females. The ovaries were collected from a slaughterhouse (Frigol - Brazil) and processed for classic histological examination. The follicular population was estimated according to Cahill et al. (1979) and calculated according to Gougeon & Chainy (1987). Young buffaloes, pregnant and non pregnat adults presented an average number of 15.5, 3.7 and 8.9 preantral follicles with normal morphology and type I (the degeneration was observed just in oocyte) and II (oocyte and granulosa cells were degenerated) degeneration, respectively. This experiment demonstrated that the proportions of primordial, primary and secondary follicles were affected by reproductive phase. A significant difference was observed considering the proportions of preantral follicles with normal morphology and Type I degeneration in all reproductive phases evaluated. The primary follicles presented more percentage of Type I degeneration that the others follicles and the primordial and primary follicles presented more percentage of Type II degeneration in three reproductive phases evaluated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Doppler ultrasonography is an important tool for evaluating hepatic portal hemodynamics. However, no study in dogs of different body weights, in the range encountered in routine clinical veterinary practice, has been reported. It can be difficult to obtain an ideal insonation angle when evaluating the main portal vein, so evaluation of the right portal vein branch has been described in humans as an alternative. The aim of this study was to analyze, through Doppler ultrasonography, the hemodynamics in the right portal vein branch in dogs of different body weights.Methods: Thirty normal dogs were divided in three groups by weight, in order to establish normal values for mean velocity, flow volume and portal congestion index of the right portal vein branch by means of Doppler ultrasonography.Results: In all dogs ideal insonation angles were obtained for the right portal vein branch. The average velocity was similar in the three groups, but the portal congestion index and the flow volume differed, showing that the weight of the dog can influence these values.Conclusion: Doppler ultrasonography for the evaluation of flow in the right branch of the portal vein could be a viable alternative, or complement, to examining the main vessel segment. This is especially so in those animals in which an ideal insonation angle for examination of the main portal vein is hard to obtain. In addition, the weight of the dog must be considered for the correct evaluation of the portal system hemodynamics, particularly for portal blood flow and the congestion index.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study used bovine ribs to comparatively assess the deformation, roughness, and mass loss for 3 different types of surface treatments with burs, used in osteotomies, for the installation of osseointegrated implants.Materials and Methods: The study used 25 bovine ribs and 3 types of helical burs (2.0 mm and 3.0 mm) for osteotomies during implant placement (a steel bur [G1], a bur with tungsten carbide film coating in a carbon matrix [G2], and a zirconia bur [G3]), which were subdivided into 5 subgroups: 1, 2, 3, 4, and 5, corresponding to 0, 10, 20, 30, and 40 perforations, respectively. The surface roughness (mean roughness [Ra], partial roughness, and maximum roughness) and mass (in grams) of all the burs were measured, and the burs were analyzed in a scanning electron microscope before and after use. Data were tabulated and statistically analyzed by use of the Kruskal-Wallis test, and when a statistically significant difference was found, the Dunn test was used.Results: There was a loss of mass in all groups (G1, G2, and G3), and this loss was gradual, according to the number of perforations made (1, 2, 3, 4, and 5). However, this difference was not statistically significant (P < .05). Regarding the roughness, G3 presented an increase in Ra, partial roughness, and maximum roughness (P < .05) compared with G2 and an increase in Ra compared with G1. There was no statistically significant difference (P > .05) between G1 and G2. The scanning electron microscopy analysis found areas of deformation in all the 2.0-mm samples, with loss of substrates, and this characteristic was more frequent in G3.Conclusions: The 2.0-mm zirconia burs had a greater loss of substrates and abrasive wear in the cutting area. They also presented an increased roughness when compared with the steel and the tungsten carbide coating film in carbon matrix. There was no statistically significant difference (P < .05) between G1 and G2 in any mechanical test carried out. (C) 2012 American Association of Oral and Maxillofacial Surgeons J Oral Maxillofac Surg 70:e608-e621, 2012

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns.Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05).Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05).Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the biomechanical behavior of a mandibular distal extension removable partial denture (DERPD) associated with an implant and different retention system, by bidimensional finite element method. Five hemimandible models with a canine and external hexagon implant at second molar region associated with DERPD were simulated: model A, hemimandible with a canine and a DERPD; model B, hemimandible with a canine and implant with a healing abutment associated to a DERPD; model C, hemimandible with a canine and implant with an ERA attachment associated to a DERPD; model D, hemimandible with a canine and implant with an O'ring attachment associated to a DERPD; and model E, hemimandible with a canine and implant-supported prosthesis associated to a DERPD. Cusp tips were loaded with 50 N of axial or oblique force (45 degrees). Finite element analysis was performed in ANSYS 9.0. model E showed the higher displacement and overload in the supporting tissues; the patterns of stress distribution around the dental apex of models B, C, and D were similar. The association between a DERPD and an osseointegrated implant using the ERA or O'ring systems shows lower stress values. Oblique forces showed higher stress values and displacement. Oblique forces increased the displacement and stress levels in all models; model C displayed the best stress distribution in the supporting structures; healing abutment, ERA, and O'ring systems were viable with RPD, but DERPD association with a single implant-supported prosthesis was nonviable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite a plethora of in situ studies and clinical trials evaluating the efficacy of fluoridated dentifrices on caries control, in vitro pH cycling models are still broadly used because they mimic the dynamics of mineral loss and gain involved in caries formation. This paper critically reviews the current literature on existing pH-cycling models for the in vitro evaluation of the efficacy of fluoridated dentifrices for caries control, focusing on their strengths and limitations. A search was undertaken in the MEDLINE electronic journal database using the keywords "pH-cycling", "demineralization", "remineralization", "in vitro", "fluoride", "dentifrice". The primary outcome was the decrease of demineralization or the increase of remineralization as measured by different methods (e. g.: transverse microradiography) or tooth fluoride uptake. Inclusion of studies, data extraction and quality assessment were undertaken independently and in duplicate by two members of the review team. Disagreements were solved by discussion and consensus or by a third party. One hundred and sixteen studies were included, of which 42 addressed specifically the comparison of dentifrices using different pH-cycling models. The other studies included meta-analysis or reviews, data about the effect of different fluoride sources on de-remineralization, different methods for analysis de-remineralization and chemical variables and characteristics of dental hard tissues that might have influence on de-remineralization processes. Generally, the studies presented ability to detect known results established by clinical trials, to demonstrate dose-related responses in the fluoride content of the dentifrices, and to provide repeatability and reproducibility between tests. In order to accomplish these features satisfactorily, it is mandatory to take into account the type of substrate and baseline artificial lesion, as well as the adequate response variables and statistical approaches to be used. This critical review of literature showed that the currently available pH-cycling models are appropriate to detect dose-response and pH-response of fluoride dentifrices, and to evaluate the impact of new active principles on the effect of fluoridated dentifrices, as well as their association with other anti-caries treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this in vivo study was to evaluate the performance of laser fluorescence (LF) comparing different cut-off limits for occlusal caries detection. One hundred and thirty first permanent molars were selected. Visual examination and LF assessments were performed independently. The extent of caries was assessed after operative intervention. New cut-off limits were established and compared with those proposed by the manufacturer and by Lussi et al. (Eur J Oral Sci 109:14-19, 2001). Similar sensitivity and higher specificity was found at D(2) (considering as disease only dentin caries) when the LF cut-off limits proposed by Lussi et al. and the new one were compared. At the D(3) threshold (considering as disease only deep dentin caries), no statistically significant difference among the cut-off limits for sensitivity was found. However, the new cut-off limits showed higher specificity. The LF device provided good ability to detect dentin caries lesions. Furthermore, the new cut-off limits and the values proposed by Lussi et al. could be suggested for the in vivo detection of occlusal caries.