747 resultados para Espectrometria de fluorescencia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple and fast method to determine Ca, K and Mg in a single aliquot of medicinal plants by HR-CS FAAS is proposed. The secondary lines for Ca (239.856 nm) and K (404.414 nm), and the alternate line measured at wing of the secondary line for Mg at (202.588 nm) allowed calibration within the 20 - 500 mg.L-1 Ca and K, and 1.0 - 80 mg.L-1 Mg. Twenty samples and three plant certified materials were analyzed. Results were in agreement at a 95% confidence level with reference values. Limits of detection were 2.4 mg.L-1 Ca, 1.9 mg.L-1 K and 0.3 mg.L-1 Mg. The RSD (n=12) were ≤ 5.1% and recoveries were between 83 and 108% for all analytes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes instrumental strategies for the determination of Mn in a wide range concentration by high-resolution continuum source flame atomic absorption spectrometry technique (HR-CS F AAS) by means of different atomic lines (primary at 279.482 nm, secondary at 403.075 nm and alternative at 209.250 nm). These lines provided complementary concentration intervals, and large sample dilutions became unnecessary. The proposed method was applied to tap water, metal alloy certified material and foliar fertilizer. Accuracy for secondary line were evaluated by tests of significance (t Student test) with reference materials from the Institute of Technological Research of São Paulo, and the results were in agreement at the 95% confidence level. For primary and alternative lines, recovery is were in the 84-116% range and the RSD were 6.1% for all wavelengths. Analytical curves in the 0.1 - 2.0 mg L-1 (279.482 nm), 2.0 - 25 mg L-1 (403.075 nm), 25 - 500 mg L-1 (209.250 nm) intervals were obtained with linear correlation coefficient better than 0.9991. The detection limits were 3.3x10-3 mg L-1 (279.482 nm), 7.4 x 10-3 mg L-1 (403.075 nm), 3.9 mg L- 1 (209.250 nm). The found Mn concentrations were < 3.3x10-3 mg L-1 (tap water), 1.00 ± 0.04 (% m/m) (alloy IPT 25), 7235 ± 175 mg L-1 (foliar fertilizer 1), 4990 ± 132 mg L-1 (foliar fertilizer 2). A method was developed to detect interference of Fe in the Mn primary line (279.482 nm) using the ratio of absorbances of other lines of the triplet (279.827 nm and 280,108 nm).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythrina verna is a medicinal plant used to calm agitation popularly known as mulungu. We purchased the barks of E. verna from a commercial producer and analyzed the alkaloid fraction of the bark by CG-MS and HRESI-MS. Five erythrinian alkaloids were identified: erysotrine, erythratidine, erythratidinone, epimer, and 11-hydroxieritratidinone. Here we report the compound 11-hydroxieritratidinone for the first time as a natural product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solutions of [hydroxy(tosyloxy)iodo]benzene (HTIB or Koser's reagent) in acetonitrile were analyzed using high resolution electrospray ionization mass spectrometry (ESI-MS) and electrospray ionization tandem mass spectrometry (ESI-MS/MS) under different conditions. Several species were characterized in these analyses. Based on these data, mechanisms were proposed for the disproportionation of the iodine(III) compounds in iodine(V) and iodine(I) species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Erythrina verna is a medicinal plant used to calm agitation popularly known as mulungu. We purchased the barks of E. verna from a commercial producer and analyzed the alkaloid fraction of the bark by CG-MS and HRESI-MS. Five erythrinian alkaloids were identified: erysotrine, erythratidine, erythratidinone, epimer, and 11-hydroxieritratidinone. Here we report the compound 11-hydroxieritratidinone for the first time as a natural product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La extinción de fluorescencia ("quenching") multif1uoróforo ha sido empleada para obtener información dinámica y estructural especialmente en muestras biológicas tales como proteínas y ácidos nucleicos

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La preservación del medio ambiente, el avance en las técnicas para que el impacto de la actividad humana sobre la fauna y flora sea lo menor posible, hacen que se deban monitorizar los diversos indicadores de calidad. El presente estudio viene motivado debido a que actualmente existen sistemas de medida y control en continuo de la calidad de las aguas, al margen de los estudios de laboratorio por toma de muestras, a través de los cuales se obtienen indicadores de calidad. El desarrollo tecnológico en analizadores en continuo para la medida de fósforo, amonio, DBO y otros, hacen que cada vez se consiga un control más exhaustivo de la calidad en tiempo real. Sin embargo, la detección temprana de contaminantes que no deben encontrarse presentes en el agua, hacen que el desarrollo de sensores de detección de estos contaminantes sea de gran utilidad. A este respecto, las técnicas mediante fluorescencia presentan enormes ventajas, ya que no existe contacto directo con la muestra, reduciéndose el desgaste y alargando el tiempo entre mantenimientos, como se ha comprobado en numerosos desarrollos con tecnología láser. Para la producir fluorescencia, tradicionalmente se vienen utilizando en el laboratorio principalmente lámparas de gas y monocromadores. Los nuevos LED de alta potencia en el espectro ultravioleta son una alternativa muy interesante que además puede ser aplicada en los mencionados sistemas de medición en continuo. En este trabajo se realiza un estudio de viabilidad de estos dispositivos como fuentes de excitación para la producción de fluorescencia tomando como contaminantes los hidrocarburos. El funcionamiento en estaciones en continuo hace que se tenga que realizar además ensayos de vida acelerados, así como estudios de modos de trabajo. Al respecto de la fluorescencia producida, se estudia la influencia de factores que pueden afectar a las medidas, tales como la temperatura. El estudio del espectro y su análisis para la identificación del contaminante es otro de los puntos desarrollados en este trabajo. Por último, y dado que la monitorización se realiza en modo continuo, es necesario un sistema de comunicaciones compacto y fiable: en este apartado se analizan los metamateriales como solución tecnológica, ya que se adapta perfectamente a la filosofía de estas estaciones de medición. ABSTRACT Currently the monitoring of quality indicators is a need to preserve the environment and minimize the impact of human activity on the fauna and flora. Currently there are measuring systems and continuous monitoring of water quality, regardless of sampling laboratory studies, through which quality indicators are obtained. Technological development in continuous analyzers for the measurement of phosphorus, ammonia, BOD and others increasingly make a more comprehensive real-time quality control is achieved. However, early detection of contaminants that should not be present in the water, make the development of sensors for detecting these contaminants is very useful. In this regard, fluorescence techniques have huge advantages, since there is no direct contact with the sample, reducing wear and extending the time between maintenance, as has been demonstrated in numerous developments in laser technology. To produce fluoresce, traditionally are being used mainly gas lamps and monochromators at the laboratory. The new high-power LEDs in the ultraviolet spectrum are a very interesting alternative that can also be applied in the above continuous measurement systems. In this paper a viability study of these devices as excitation sources to produce fluorescence using hydrocarbon as contaminants is performed. The stations in continuous operation makes it necessary to also perform accelerated life tests and studies operating modes. In regard to the fluorescence produced, the influence of factors that may affect the measurements, such as temperature is studied. The study of the spectrum and analysis to identify the contaminant is another of the points developed in this work. Finally, since the monitoring is carried out in continuous mode, a compact and reliable communication is necessary: in this section metamaterials as a technological solution is analyzed since it fits perfectly with the philosophy of these measuring stations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A constante preocupação com o aumento do uso de agrotóxicos nas lavouras e os riscos gerados pelos resíduos destes compostos fazem com que os órgãos responsáveis pela fiscalização de alimentos no Brasil controlem a presença dessas substâncias nos produtos que chegam à mesa do consumidor. Atualmente, um dos grandes problemas na produção de alimentos é a utilização de substâncias proibidas em lavouras, muitas das quais não possuem estudos nem limites máximos de resíduos (LMR) estabelecidos, assim como a utilização de substâncias já registradas, mas em quantidades ou métodos de manejo incorretos. Ambos os casos podem resultar em sérios problemas à saúde humana. O objetivo deste estudo foi a avaliação da determinação de morfolina em amostras de manga utilizando técnicas como a Extração em Fase Sólida e a Cromatografia Gasosa acoplada à Espectrometria de Massas (SPE-GC-MS), assim como a Microextração em Sorvente Empacotado e Cromatografia Gasosa acoplada à Espectrometria de Massas (MEPS-GC-MS). Um segundo objetivo deste estudo consistiu em desenvolver, validar e avaliar uma metodologia analítica capaz de identificar quantitativamente a morfolina em amostras de manga por Cromatografia Líquida de Ultra Eficiência acoplada a Espectrometria de Massas em tandem (UHPLC-MS/MS). Para análise por GC-MS fez-se necessária a etapa de derivatização do analito, de forma que o mesmo aumentasse sua volatilidade e diminuísse a polaridade. A comparação entre as técnicas SPE e MEPS não foi possível devido ao efeito de matriz causado pela contaminação do liner e da coluna cromatográfica. Já a metodologia validada por UHPLC-MS/MS seguiu os critérios exigidos pelo Manual de Garantia da Qualidade Analítica, do Ministério da Agricultura Pecuária e Abastecimento (MAPA). O método foi aplicado em mangas de diferentes variedades obtidas no comércio local. Não foram encontrados resíduos de morfolina em nenhuma das amostras investigadas, de acordo com a metodologia proposta. Os resultados apresentados neste trabalho estabelecem metodologias eficientes, rápidas e de baixo custo na determinação de morfolina em amostras de manga.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Na primeira parte do trabalho, foram investigados materiais ativos para eletro-oxidar etanol e acetaldeído seletivos para a rota C2 (Carbono 2) e, também, ativos para eletro-oxidar hidrogênio molecular, visando a aplicação em células a combustível de hidrogênio indireto. Neste tipo de célula, um processador de combustível externo desidrogena o etanol e os produtos desta reação, contendo H2, acetaldeído e, possivelmente, etanol residual, são direcionados para alimentar o ânodo. Neste sentido, o eletrocatalisador anódico pode ser ativo para a eletro-oxidação de etanol residual, bem como acetaldeído, mas este deve catalisar a reação via C2 com o objetivo de evitar a formação de espécies que envenenam a superfície catalítica (CO ou CHx), ou seja, a ligação C-C deve permanecer intacta. Os eletrocatalisadores bimetálicos foram formados por M/Pt/C (onde M = W, Ru ou Sn) e os produtos reacionais foram analisados por DEMS On-line. Os resultados mostraram que Ru/Pt/C e Sn/Pt/C apresentaram maiores taxas de reação global, no entanto, eles não foram seletivos. Por outro lado, W2/Pt3/C foi mais seletivo para a rota C2, dada a não formação de CH4 e CO2. Além disso, este material também foi ativo e estável para a eletro-oxidação de H2, mesmo na presença de acetaldeído, o que o torna um potencial catalisador para aplicação no ânodo de células a combustível de hidrogênio indireto. Na segunda parte do trabalho, o objetivo foi relacionado com o estudo de eletrocatalisadores seletivos para a rota C1 (Carbono 1). A oxidação eletroquímica do etanol e de seus produtos reacionais foram investigados por DEMS on-line em temperatura ambiente e intermediária (245oC). Para temperatura ambiente, utilizou-se solução aquosa de ácido sulfúrico (H2SO4) e, para temperatura intermediária, utilizou-se ácido sólido (CsH2PO4) como eletrólito. Os eletrocatalisadores investigados foram formados por SnOxRuOx-Pt/C e Pt/C. Em temperatura ambiente, os resultados de polarização potenciodinâmica mostraram uma maior atividade eletrocatalítica para o material SnOxRuOx-Pt/C, com eficiência de corrente para formação de CO2 de 15,6% contra 15,2% para Pt/C, sob condições estagnantes, sem controle por transporte de massa. O stripping de resíduos reacionais, após a eletro-oxidação de etanol bulk, sob condições de fluxo, mostraram o acúmulo de espécies com 1 átomo de carbono (CO e CHx) que causam o bloqueio dos sítios ativos e são oxidadas eletroquimicamente somente em mais altos potenciais (ca. 1,0 V). Por outro lado, as curvas de polarização a 245oC mostraram maiores valores de eficiências de correntes para formação de CO2 (45% para Pt/C em ambos potenciais 0,5 V e 0,8 V contra 36% e 50% para SnOxRuOx-Pt/C em 0,5 V e 0,8 V respectivamente) quando comparado com os valores obtidos em temperatura ambiente, mas com atividades similares para SnOxRuOx-Pt/C e Pt/C. Para ambos os eletrocatalisadores, os estudos de espectrometria de massas a 245oC evidenciaram que as rotas eletroquímicas ocorrem em paralelo com rotas puramente químicas, envolvendo catálise heterogênea, de decomposição do etanol, produzindo H2 e CO2 como produtos majoritários.