997 resultados para Equipamentos de Proteção


Relevância:

40.00% 40.00%

Publicador:

Resumo:

This monograph presents the main objective of analyzing the redundancy protection systems of protection for redundancy and block of energies against accident in presses and rotating equipment. After understanding two specific goals, on this case, show the systems of protection against accidents in rotating equipments, presses and similar; and discuss the vulnerabilities of current systems of protection against accidents in presses and similar, we will propose a system of autonomous redundancy of Programmable Logic Controller (PLC) operating simultaneously taking online in the event of failure of one of the two. The methodology was worked through a revision of a variety of bibliography, and interpretation of national and international standards as well as access to research on systems, practices used in industrial and companies supplying products and of companies and energy blockages solutions

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This monograph presents the main objective of analyzing the redundancy protection systems of protection for redundancy and block of energies against accident in presses and rotating equipment. After understanding two specific goals, on this case, show the systems of protection against accidents in rotating equipments, presses and similar; and discuss the vulnerabilities of current systems of protection against accidents in presses and similar, we will propose a system of autonomous redundancy of Programmable Logic Controller (PLC) operating simultaneously taking online in the event of failure of one of the two. The methodology was worked through a revision of a variety of bibliography, and interpretation of national and international standards as well as access to research on systems, practices used in industrial and companies supplying products and of companies and energy blockages solutions

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Os acidentes envolvendo veículos de duas rodas, são um dos maiores problemas da segurança rodoviária atual, no âmbito Europeu. Um dos tipos de acidentes que pode causar danos mais graves aos ocupantes desses veículos é o embate com guardas de segurança. Em consequência disso, neste trabalho foram desenvolvidas opiniões, abonatórias ou não, ao uso de dispositivos de proteção para motociclistas acoplados nas guardas de segurança. Estas opiniões vão partir de dados estatísticos, de estudos e exemplos concretos de vários autores e publicações relacionados com esta temática, sendo que o tipo de dispositivo de proteção para motociclistas que vai estar mais em foco e sendo ele o mais habitual nas estradas portuguesas será a saia metálica. Estes dispositivos de segurança para motociclistas ainda não são de uso obrigatório nas guardas de segurança na maioria dos países do continente Europeu, segundo a norma europeia EN 1317, apesar deste tipo de proteção já estar normalizada segundo padrões de lesões biomecânicos na zona da cabeça, cervical e anca/abdómen descritos na norma EN 1317 UNE 135900 – 1:2003, em alguns países é descurado o uso destas proteções, por não serem obrigatórias e porque ainda se tornam mais dispendiosas que as guardas de segurança habituais (barreiras de metal simples). Este estudo serviu essencialmente para verificar se estes dispositivos salvaguardam ou não a vida dos utilizadores de duas rodas, pois, se pelo contrário, aumentam ainda o risco, ou de lesões mais gravosas ou mesmo de morte, aquando o embate com as mesmas, os gastos associados a este tipo de equipamentos serão totalmente inúteis e desnecessários.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A atividade de técnico responsável das instalações eléctricas é, e será sempre, cada vez mais, uma atividade estimulante e com constante necessidade de atualização e evolução. Trata-se de uma atividade extremamente vasta e diferenciada, requerendo, por um lado, um profundo conhecimento, relativamente a normas, regulamentos, materiais, equipamentos, soluções técnicas e tecnologias e, por outro lado, a intervenção numa diversificada área de instalações. A constante e acelerada evolução técnica, tecnológica e conceptual de equipamentos e das instalações elétricas, faz com que o corpo normativo não possa ser estático, mas antes que possa evoluir de forma a poder contemplar e dar resposta a essas novas realidades. Para se poder ser, de uma forma cabal, responsável pelo projeto, execução e exploração de instalações elétricas é imprescindível o conhecimento exato dos diversos diplomas legais, em vigor, que enquadram a instalação e a actividade em questão. O presente artigo tem como objetivo principal, sistematizar e apresentar o corpo normativo relativo à aparelhagem de proteção, comando e seccionamento de baixa tensão.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical energy is present in the lives of all people and is extremely important that it be delivered to end users with plenty of quality, safety and low costs. The electric power substations are responsible for transmission and distribution of electricity generating sources to consumers, and with technological advances and the subsequent automation of same, the electricity began to be delivered with greater continuity and reliability. Protection systems in substations are largely responsible for making the electricity reaches the final consumer with quality, since their function is to prevent the spread of any type of failure occurred at any point of transmission to the load centers. These systems consist primarily by the current transformers and potential, by the protective relays and circuit breakers and switchgear. The processors send the necessary data to the relays and, if those detect any abnormality in the system, operate the opening command of the branch circuit breakers to isolate where the fault. Therefore, it is essential to better understand the operation of such equipment, as well as the overall system. This work aims to study the main substation equipment, current transformers and potential and, especially, protection relays, in order to obtain the advantages that automated systems can provide

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Large electric motors require greater care when driving, especially during continuous operation since they are part of day-to-day manufacturing sector, acting essentially to ensure that no damage occurs to the production process and equipment that are part of the same system. This work includes the analysis of electrical protection in a system comprised of a three phase induction motor driven by a frequency converter as well as an analysis of the functions of a multifunction electronic relay. It is presented a comparison between the existing functions in a converter and a relay and a real case is described in order to exemplify the use of an electric motor and features that are aimed at their protection, and the system in which it is inserted. Based on the results, it is of great importance in this field of performance studies, generating relevant results, which may be exposed in order to unify into a single document, different sources of information that are arranged randomly, improve utilization motor and extend the life of equipment forming part of the electrical installation

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O uso de radiações ionizantes (R.I.), nas mais variadas atividades tem aumentado nas últimas décadas. Com o avanço tecnológico, novos e sofisticados equipamentos emissores de R.I. tem surgido no cenário nacional, o que torna imperativo a difusão do conhecimento sobre os conceitos de proteção radiológica junto à comunidade em geral, e neste sentido, o curso de física médica desenvolve um importante papel, quer seja no aspecto informativo quanto formativo de cidadãos e profissionais críticos e politicamente corretos, que possam contribuir com as Políticas Públicos dos órgãos normatizadores e fiscalizadores das atividades de vigilância sanitária. Conforme a legislação atual (Resolução SS-625 de 14/12/1994, da Secretaria de Estado da Saúde, e Portaria 453 de 01/06/1998 da Vigilância Sanitária do Ministério da Saúde), todos os serviços que utilizam radiações ionizantes devem realizar testes de avaliação dos parâmetros radiométricos dos equipamentos emissores de R.I., sendo exigidos as medidas de Levantamento Radiométrico das instalações, o Teste de Radiação de Fuga do cabeçote emissor e a implementação de Programa de Garantia de Qualidade dos equipamentos e dos procedimentos radiológicos. Este procedimento tem como objetivo principal a obtenção de imagens radiográficas com qualidade e a segurança de pacientes e profissionais, evitando a exposição desnecessária à radiação de pacientes e profissionais. A correta realização de procedimentos radiológicos além de reduzir a dose nos pacientes também promove significativa diminuição nos custos, por não haver necessidade da repetição dos exames. No Brasil, conforme dados da Secretaria de Atenção à Saúde SAS/MS, atualmente existem instalados 4.469 mamógrafos, 25.930 aparelhos de raios-x médicos, 39.438 aparelhos de raios-x odontológicos e...(Resumo completo, clicar acesso eletrônico abaixo)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The proposed of scanning of an electrical industrial substation HV is associated with a segment of the Electrotechnical area and aims the study and preliminary application of digital technologies in the protection, control, measurement and automation maneuvers aimed at a Industrial Electrical System typical High Voltage. Well intended to supervision, protection and control of major electrical and thermal quantities involved in a substation, such as voltage levels, current, temperature, power factor, loads of transformers and circuit feeders, status of interlocking devices, switching equipment maneuvers, etc

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Electrical installations in industries involving high currents and voltages considered. On the other side is the common appearance of electrical failures, caused by human error, defects in electrical equipment or electrical installation aging itself. These failures are varied, those with the highest rate of occurrence and cause much damage to electrical installations, are overcurrent and overvoltage. Therefore there is a need to project a system that can detect and minimize possible effects caused by faults in electrical installations industries. Protection systems in electric industries emerge as an alternative to control especially voltage and current magnitudes. Engineered based on the functions of the relays, protection systems are an indispensable tool for any industrial substation. But the project of such systems becomes increasingly more complex, due to technological development. Electrical equipment not develop at the same speed that the protective devices (relays), making it indispensable knowledge of integration of technologies

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the growth of the demand on electric energy in the last decades, the urban distribution and transmission systems have experienced a bigger necessity to improve on the substations, the automation procedures and techniques on the operation maneuvers of such systems, in a sense that better attends the quality levels, availability, continuity and operational reliability. In this way, the objective of the present paper is to perform a study of protection and control on an electrical industrial system involving the procedures of digitizing and maneuvers automatism utilizing operational techniques and other pertinent information used in a typical high-voltage Industrial Electrical System. Analysis were made on short-circuits to specify the main components of the 138 [kV] substation, in addition, there were used digital MiCOM relays to make the protection of the present elements. With that, a program was developed to allow the user to monitor the condition of circuit-breakers through a supervision screen being able to simulate some kinds of faults, as well as observing the characteristics of each device. This way, the importance of having a fast and reliable system that ensures the equipment’s protection and the industrial process continuity due to faults on the electrical system is noticeable. It’s important to highlight that all this digitizing was mainly favored by the development of digital technology on the last years, mainly on microelectronics, also with the appearance of supervision gadgets allowing the development of complex systems in supervision and electric energy control

Relevância:

30.00% 30.00%

Publicador:

Resumo:

After the discovery of ionizing radiation, its applications in various fields of science began to take significant proportions. In the case of medicine, there are the application areas in radiotherapy, diagnostic radiology and nuclear medicine. It was then necessary to create the field of radiological protection to establish the conditions necessary for the safe use of such ionizing radiation. Apply knowledge obtained during the graduation stage and in the practice of radiological protection in the areas of nuclear medicine and diagnostic radiology. In the area of nuclear medicine, tests were made in the Geiger-Muller counters (GM) and the dose calibrator (curiometer), the monitoring tests of radiation, waste management, clean of the Therapeutic room and testing the quality control of gamma-chambers. In the area of radiology, were performed tests of quality control equipment for conventional X-ray equipment and x-ray fluoroscopy, all following the rules of the National Health Surveillance Agency (ANVISA), and reporting of tests. The routine developed in the fields of nuclear medicine in hospitals has proved very useful, since the quality control of GM counters contribute to the values of possible contamination are more reliable. The control of dose calibrator enables the patient not to receive different doses of the recommended amounts, which prevents the repetition of tests and unnecessary exposure to radiation. The management of waste following the rules and laws established and required for its management. Tests for quality control of gamma chambers help to evaluate its medical performance through image. In part of diagnostic radiology, tests for quality control are performed in order to verify that the equipment is acceptable for usage or if repairs are needed. The knowledge acquired at the internship consolidated the learning of graduation course

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este projeto de pesquisa trata sobre a influência de processos educacionais e de conscientização junto a dois grupos de famílias, em três gerações, que convivem em áreas de proteção dos mananciais da represa Billings, reservas de produção hídrica de alta importância estratégica para gestão de um ambiente e seus ecossistemas frágeis com uma acentuada necessidade preservacionista e estrutural para a manutenção de sua qualidade para as atuais e futuras gerações. A importância dos resultados obtidos pela pesquisa sobre o longo processo de conscientização destas comunidades são fundamentais para perceber o status em que se encontram, seja a partir das condições e de seu status quanto as relações da escola na formação da consciência ambiental através de observações das condições de vida no próprio habitat, pela questão da terra, da relação fundiária conquistada quanto à propriedade em que residem, pelo esgotamento sanitário, incluindo condição e destino dos dejetos e águas residuárias, origem da água para dessedentação e da gestão sobre as doenças. Além destas questões este trabalho buscou importantes relações quanto às condições das fontes hídricas e seus usos múltiplos pela comunidade local, seja para lazer e consumo de bens naturais, tipos de tratamento da poluição e contaminação ambiental, infra-estrutura e equipamentos públicos existentes como suporte sustentável a qualidade de vida dos cidadãos locais.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Área de Proteção Ambiental de Jenipabu was created by Decreto 12,620/95, covering the beaches of Redinha Nova, Santa Rita and Jenipabu and Campina communities in the municipality of Extremoz, and Africa community fragment, in Natal. This protected area was created in the context of expansion of tourism in Rio Grande do Norte, in the 1990s, in which PRODETUR investments made possible the installation of infrastructure equipment, mainly in the Via Costeira and Ponta Negra beach in Natal by inserting it in the sun and sea tourism route to Northeast Brazil. In this context the beach Jenipabu in Extremoz, became one of the main attractions for those visiting Natal, due to the natural elements of its landscape, its dune field, which is offered to tourists the buggy ride. In December 1994 the excess buggy rides held in these dunes led to IBAMA ban their access to buggy for carrying out environmental study. This measure resulted in the creation of APAJ in 1995 with the goal of ordering the use and occupation to protect its ecosystems, especially the dunes, the disordered tourism. Given this context, this work aims to analyze the process of creating the APAJ and changes in the geographic space of its beaches, Redinha Nova, Santa Rita and Jenipabu, from the materialization of tourism process, as well as their implications for its residents. To this end, this paper presents a discussion of environmental currents that developed in the western portion of the globe, focusing on the need to regulate small areas of the national territory in protected areas, and an analysis of public policies that enabled the implementation tourism in APAJ as well as the laws and decrees governing the process of creation and management. Using the theory of circuits of urban economy of the Santos (2008) to analyze the territory used by tourism on the beaches of Redinha Nova, Santa Rita and Jenipabu, showing their dependent relationship with the territory used by the upper circuit on the Via Costeira and in the Ponta Negra beach and its influence on the APAJ urbanization process. Ending with the analysis of the influence of the materialization of tourism in the transformation of stocks ways of being-in-space and space-be of the Santa Rita and Jenipabu beaches in each geographical situation of APAJ among the first decades of the twentieth century to the 2014. Fieldwork was conducted between 2012 and 2014, performing actions of qualitative interviews with older residents of Santa Rita and Jenipabu beaches, interviews with structured questionnaire with merchants of APAJ and collecting GPS points trades, identifying and mapping the territory used by the lower circuit in APAJ beaches.