947 resultados para Energy-distribution


Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aimed to study evaporation distribution in a protected environment. The experiment was set up in polyethylene greenhouse at the Lageado Experimental Farm in the School of Agronomic Sciences (FCA, UNESP-Botucatu) in the winter of 2005. 132 500-ml plastic micro evaporimeters (13.7 diameter) were used used to obtain evaporation values and analyze spatial energy distribution. These micro evaporimeters were distributed in 44 equidistant points, at three different heights from the soil surface: 0.40, 0.80 and 1.20cm The tunnel-type greenhouse was 7.5 m wide, 27.5 m long and 3.20 m high at the center, and was covered with black shadow screen (sombrite) on the sides. Southeast/northwest orientation, based on true north, was used foro othe greenhouse longitudinal axis. For variable comparison, a geostatistics was used through the □GS+ program. From obtained data, it was concluded that: there was spatial variability at different points and heights of the microevaporation values obtained from micro evaporimeters were not greenhouse; the Class A Pan installed outside the greenhouse can be used to evaluate the internal evaporation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work aimed to study the energy distribution in protected environment during the winter of 2005. A plastic tunnel (27.5 m long, 7.5 m wide, 3.2 m high in the center and 2.00 m high in both lateral sides) was covered with polyethylene 100 micra and black shadow screen (sombrite) in lateral sides at the FCA/UNESP, Botucatu - SP. 142 minievaporimeters (500 ml volume and 147 cm2 area) were evenly distributed and set up at three heights: 0.40 m; 0.80 m and 1.20 m from soil surface in order to analyze energy distribution along the studied area. The greenhouse longitudinal axis was northwest/southeast, based on true north. Geosatistics principles and the GS+ Program were adopted to compare variables. From obtained results, it was concluded that there were significant evaporation variations at different points anf heights; the highest values were the ones closest to the soil surface (0.40m) in July and at highest heights (0.80 and 1.20m). Highest evaporations occurred in the southeastern side of the greenhouse.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The need for high reliability and environmental concerns are making the underground networks the most appropriate choice of energy distribution. However, like any other system, underground distribution systems are not free of failures. In this context, this work presents an approach to study underground systems using computational tools by integrating the software PSCAD/EMTDC with artificial neural networks to assist fault location in power distribution systems. Targeted benefits include greater accuracy and reduced repair time. The results presented here shows the feasibility of the proposed approach. © 2012 IEEE.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este trabalho apresenta uma análise da qualidade de energia realizado em um sistema real de distribuição de energia elétrica, a partir das diferentes classes de consumo atendida pela concessionária. O estudo foi realizado em duas etapas, sendo a primeira através de medições realizadas no secundário de transformadores da rede de distribuição que atende ao sistema da CEA (Companhia de Eletricidade do Amapá), previamente classificados por classe de atendimento sendo, classe comercial, residencial e mista. Através do estudo torna-se possível a identificação e a caracterização de fontes geradoras de harmônicos no sistema, possibilitando assim a análise do nível de injeção de harmônicos em sua rede de distribuição, bem como a avaliação dos impactos que essas fontes distribuídas de geração harmônica podem provocar na qualidade de energia fornecida pela concessionária. A etapa final do estudo apresenta o uso de um fluxo de carga harmônico trifásico, onde a partir do perfil harmônico obtido no estudo, é feita uma avaliação de forma global do sistema.