910 resultados para Energy performance rating


Relevância:

90.00% 90.00%

Publicador:

Resumo:

The behaviour of building occupants can have a significant impact on in-use energy performance. In these pilot studies, based on the Elaboration Likelihood Model, interactivity was incorporated in the design of behavioural interventions to assess its effectiveness in promoting energy-saving behaviours. An interactive poster and an interactive prompt were designed to ‘nudge’ occupants’ behaviours towards energy-saving. The poster was installed in an office building and was intended to encourage occupants to save energy by taking the stairs, rather than the lifts, by providing them with cumulative metaphorical feedback. The prompt was installed in student halls of residence and intended to act as a reminder to the occupants to turn the lights off by providing them with an immediate playful reward. The results showed that interactivity can ‘nudge’ occupants’ behaviours when it is combined with a clear message/feedback. The results also suggest that simple immediate feedback can be effective in encouraging energy-efficient behaviours.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Different treatments that could be implemented in the home environ-ment are evaluated with the objective of reaching a more rational and efficient use of energy. We consider that a detailed knowledge of energy-consuming behaviour is paramount for the development and implementation of new technologies, services and even policies that could result in more rational energy use. The proposed evaluation methodology is based on the development of economic experiments implemented in an experimental economics laboratory, where the behaviour of individuals when making decisions related to energy use in the domestic environment can be tested.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dynamic system test methods for heating systems were developed and applied by the institutes SERC and SP from Sweden, INES from France and SPF from Switzerland already before the MacSheep project started. These test methods followed the same principle: a complete heating system – including heat generators, storage, control etc., is installed on the test rig; the test rig software and hardware simulates and emulates the heat load for space heating and domestic hot water of a single family house, while the unit under test has to act autonomously to cover the heat demand during a representative test cycle. Within the work package 2 of the MacSheep project these similar – but different – test methods were harmonized and improved. The work undertaken includes:  • Harmonization of the physical boundaries of the unit under test. • Harmonization of the boundary conditions of climate and load. • Definition of an approach to reach identical space heat load in combination with an autonomous control of the space heat distribution by the unit under test. • Derivation and validation of new six day and a twelve day test profiles for direct extrapolation of test results.   The new harmonized test method combines the advantages of the different methods that existed before the MacSheep project. The new method is a benchmark test, which means that the load for space heating and domestic hot water preparation will be identical for all tested systems, and that the result is representative for the performance of the system over a whole year. Thus, no modelling and simulation of the tested system is needed in order to obtain the benchmark results for a yearly cycle. The method is thus also applicable to products for which simulation models are not available yet. Some of the advantages of the new whole system test method and performance rating compared to the testing and energy rating of single components are:  • Interaction between the different components of a heating system, e.g. storage, solar collector circuit, heat pump, control, etc. are included and evaluated in this test. • Dynamic effects are included and influence the result just as they influence the annual performance in the field. • Heat losses are influencing the results in a more realistic way, since they are evaluated under "real installed" and representative part-load conditions rather than under single component steady state conditions.   The described method is also suited for the development process of new systems, where it replaces time-consuming and costly field testing with the advantage of a higher accuracy of the measured data (compared to the typically used measurement equipment in field tests) and identical, thus comparable boundary conditions. Thus, the method can be used for system optimization in the test bench under realistic operative conditions, i.e. under relevant operating environment in the lab.   This report describes the physical boundaries of the tested systems, as well as the test procedures and the requirements for both the unit under test and the test facility. The new six day and twelve day test profiles are also described as are the validation results.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Recent studies have shown that the optical properties of building exterior surfaces are important in terms of energy use and thermal comfort. While the majority of the studies are related to exterior surfaces, the radiation properties of interior surfaces are less thoroughly investigated. Development in the coil-coating industries has now made it possible to allocate different optical properties for both exterior and interior surfaces of steel-clad buildings. The aim of this thesis is to investigate the influence of surface radiation properties with the focus on the thermal emittance of the interior surfaces, the modeling approaches and their consequences in the context of the building energy performance and indoor thermal environment. The study consists of both numerical and experimental investigations. The experimental investigations include parallel field measurements on three similar test cabins with different interior and exterior surface radiation properties in Borlänge, Sweden, and two ice rink arenas with normal and low emissive ceiling in Luleå, Sweden. The numerical methods include comparative simulations by the use of dynamic heat flux models, Building Energy Simulation (BES), Computational Fluid Dynamics (CFD) and a coupled model for BES and CFD. Several parametric studies and thermal performance analyses were carried out in combination with the different numerical methods. The parallel field measurements on the test cabins include the air, surface and radiation temperatures and energy use during passive and active (heating and cooling) measurements. Both measurement and comparative simulation results indicate an improvement in the indoor thermal environment when the interior surfaces have low emittance. In the ice rink arenas, surface and radiation temperature measurements indicate a considerable reduction in the ceiling-to-ice radiation by the use of low emittance surfaces, in agreement with a ceiling-toice radiation model using schematic dynamic heat flux calculations. The measurements in the test cabins indicate that the use of low emittance surfaces can increase the vertical indoor air temperature gradients depending on the time of day and outdoor conditions. This is in agreement with the transient CFD simulations having the boundary condition assigned on the exterior surfaces. The sensitivity analyses have been performed under different outdoor conditions and surface thermal radiation properties. The spatially resolved simulations indicate an increase in the air and surface temperature gradients by the use of low emittance coatings. This can allow for lower air temperature at the occupied zone during the summer. The combined effect of interior and exterior reflective coatings in terms of energy use has been investigated by the use of building energy simulation for different climates and internal heat loads. The results indicate possible energy savings by the smart choice of optical properties on interior and exterior surfaces of the building. Overall, it is concluded that the interior reflective coatings can contribute to building energy savings and improvement of the indoor thermal environment. This can be numerically investigated by the choice of appropriate models with respect to the level of detail and computational load. This thesis includes comparative simulations at different levels of detail.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work aims to study and analyze strategies and measures to improve energy performance in residential and service buildings, in order to minimize energy losses and energy consumption. Due to the high energy dependence of European Union (EU), including Portugal and Slovenia, and high percentage of energy consumption in the building sector, there was a need to adopt strategies at European level with ambitious goals. This came to force EU - Member States to take measures to achieve the proposed targets for energy consumption reduction. To this end, EU - Member States have adapted the laws to their needs and formed specialized agencies and qualified experts on energy certification, which somehow evaluate buildings according to their performance. In this study, the external characteristics of the building in order to meet its thermal needs and from there to survey the existing and possible constructive solutions to be used at the envelope will be examined, in order to increase comfort and reduce the need of use technical means of air conditioning. The possibility of passive heating and ventilation systems also will be discussed. These techniques are developed in parallel with the deployment and design of the building. In this manner, to reduce the energy consumption, various techniques and technologies exploit natural resources. Thus, appear the more sustainable and efficient buildings, so-called Green Buildings have been appeared. The study ends with the identification of measures used in several buildings, proving the economic return in the medium to long term, as well as the satisfaction of their users.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

PEDRINI, Aldomar; WESTPHAL, F. S.; LAMBERT, R.. A methodology for building energy modelling and calibration in warm climates. Building And Environment, Australia, n. 37, p.903-912, 2002. Disponível em: . Acesso em: 04 out. 2010.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nowadays, evaluation methods to measure thermal performance of buildings have been developed in order to improve thermal comfort in buildings and reduce the use of energy with active cooling and heating systems. However, in developed countries, the criteria used in rating systems to asses the thermal and energy performance of buildings have demonstrated some limitations when applied to naturally ventilated building in tropical climates. The present research has as its main objective to propose a method to evaluate the thermal performance of low-rise residential buildings in warm humid climates, through computational simulation. The method was developed in order to conceive a suitable rating system for the athermal performance assessment of such buildings using as criteria the indoor air temperature and a thermal comfort adaptive model. The research made use of the software VisualDOE 4.1 in two simulations runs of a base case modeled for two basic types of occupancies: living room and bedroom. In the first simulation run, sensitive analyses were made to identify the variables with the higher impact over the cases´ thermal performance. Besides that, the results also allowed the formulation of design recommendations to warm humid climates toward an improvement on the thermal performance of residential building in similar situations. The results of the second simulation run was used to identify the named Thermal Performance Spectrum (TPS) of both occupancies types, which reflect the variations on the thermal performance considering the local climate, building typology, chosen construction material and studied occupancies. This analysis generates an index named IDTR Thermal Performance Resultant Index, which was configured as a thermal performance rating system. It correlates the thermal performance with the number of hours that the indoor air temperature was on each of the six thermal comfort bands pre-defined that received weights to measure the discomfort intensity. The use of this rating system showed to be appropriated when used in one of the simulated cases, presenting advantages in relation to other evaluation methods and becoming a tool for the understanding of building thermal behavior

Relevância:

90.00% 90.00%

Publicador:

Resumo:

An experiment was conducted to evaluate the performance and carcass yield of broilers at 55 days of age fed diets with different levels of metabolizable energy and lysine. Evaluated data of performance were weight gain, feed intake, energy intake, lysine intake, caloric conversion and feed conversion. Carcass assessment was performed based on data from carcass yield, breast weight, whole wings, whole legs, back, head + neck, feet and abdominal fat. A 3 x 3 factorial arrangement was used, with 3 levels of metabolizable energy (3,200; 3,400 and 3,600 kcal ME/kg) and 3 lysine levels (0.95%; 1.05% and 1.15%). There was no interaction between the two factors. Nevertheless, increasing levels of metabolizable energy improved weight gain (745 g; 841 g and 910 g, respectively) and feed intake was higher in broilers receiving the diets with 3,200 and 3,600 kcal ME/kg. Overall performance was not affected by lysine levels. Feed conversion values were 2.69, 2.42 and 2.14 for birds fed diets with 3,200; 3,400 and 3,600 kcal ME/kg, respectively. Carcass yield and breast weight increased with higher levels of energy and lysine in the diets.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This research this based on the seminar on Use of Natural Fluids in Refrigeration and Air-Conditioning Systems conducted in 2007 in Sao Paulo. The event was inserted in the National Plan for Elimination of CFCs, coordinated by the Ministry of Environment and implemented by the United Nations Development Programme (UNDP). The objective of this research is analyze the performance of the hydrocarbons application as zeotropic mixtures in domestic refrigerator and validate the application of technical standards for pull down and cycling (on-off) tests to the mixture R290/R600a (50:50) in domestic refrigerator. It was first developed an computational analysis of R290/R600a (50:50) compared to R134a and other mass fractions of the hydrocarbons mixtures in the standard ASHRAE refrigeration cycle in order to compare the operational characteristics and thermodynamic properties of fluids based on the software REFPROP 6.0. The characteristics of the Lorenz cycle is presented as an application directed to zeotropic mixtures. Standardized pull down and cycling (on-off) tests were conducted to evaluate the performance of the hydrocarbons mixture R290/R600a (50:50) as a drop-in alternative to R134a in domestic refrigerator of 219 L. The results showed that the use of R290/R600a (50:50) with a charge of refrigerant reduced at 53% compared to R134a presents reduced energy performance than R134a. The COP obtained with hydrocarbon mixture was about 13% lower compared to R134a. Pull down times in the refrigerator compartments for fluids analyzed were quite close, having been found a 4,7% reduction in pull down time for the R290/R600a compared to R134a, in the freezer compartment. The data indicated a higher consumption of electric current from the refrigerator when operating with the R290/R600a. The values were higher than about 3% compared to R134a. The charge of 40 g of R290/R600a proved very low for the equipment analyzed

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Belize is currently faced with several critical challenges associated with the production, distribution and use of energy. Despite an abundance of renewable energy resources, the country remains disproportionately dependent on imported fossil fuels, which exposes it to volatile and rising oil prices, limits economic development, and retards its ability to make the investments that are necessary for adapting to climate change, which pose a particularly acute threat to the small island states and low-lying coastal nations of the Caribbean. This transition from energy consumption and supply patterns that are based on imported fossil fuels and electricity towards a more sustainable energy economy that is based on environmentally benign, indigenous renewable energy technologies and more efficient use of energy requires concerted action as the country is already challenged by limited fiscal space which reduces its ability to provide some fiscal incentives, which have been proven to be effective tools for the promotion of sustainable energy markets in a number of countries. This report identifies the fiscal and regulatory barriers to implementation of energy efficiency measures and renewable energy technologies in Belize. Data and information were derived from stakeholder consultations conducted within the country. The major result of the assessment is that the transition of policies and plans into tangible action needs to be increased. In this regard, it is necessary to articulate sub-policies of the National Energy Policy to amend the Public Utilities Commission Act, to develop a grid interconnection policy, to establish minimum energy performance standards for buildings and equipment and to develop a public procurement policy. Finally, decisions on renewable energy and energy efficiency-related incentives from the Government formally requires decision-makers to solve what may be extremely complex optimization problems in order to obtain the lowest-cost provision of energy services to society, thereby weighing the cost of revenue losses with the benefits of fuel and infrastructure expansion savings. The establishment of a management system that is efficient, flexible, and transparent, which will facilitate the implementation of the strategic objectives and outputs in the time available, with the financial resources allocated is recommended. Support is required for additional institutional and capacity strengthening.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study evaluated a nonlinear programming excel workbook PPFR (http://www.fmva.unesp.br/ppfr) for determining the optimum nutrient density and maximize margins. Two experiments were conducted with 240 one-day-old female chicks and 240 one-day-old male chicks distributed in 48 pens (10 chicks per pen, 4 replicates) in a completely randomized design. The treatments include the average price history (2009s and 2010s) for broiler increased and decreased by 25% or 50% (5 treatments to nonlinear feed formulation) and 1 linear feed formulation. Body gain, feed intake, feed conversion were measured at 21, 42 and 56 d of age. Chicks had ad libitum access to feed and water in floor pens with wood shavings as litter. The bio-economic Energy Conversion [BEC= (Total energy intake*Feed weighted cost per kg)/ (Weight gain*kg live chicken cost)] was more sensitive for measuring the bio-economic performance for broilers, and especially with better magnitude. This allowed a better assessment of profitability, the rate of growth and not just energy consumption, the production of broilers, by incorporating energy consumption, allowing for more sensitivity to the new index (BEC). The BEC was demonstrated that the principle of nonlinear formulation minimizes losses significantly (P<0.05), especially under unfavorable conditions the price of chicken in the market. Thus, when considering that a diet of energy supply shows up as the most expensive item of a formulation, it should compose necessarily the formula proposed for a bio-economic index. Thus, there is need to evaluate more accurately, not only the ingredients of a ration, but the impact of nutrients on the stability of a solution, mainly due to the energy requirement. This strategy promotes better accuracy for decision making under conditions of uncertainty, to find alternative post-formulation. From the above, both weight gain and feed conversion, as traditional performance indicators, cannot finalize or predict a performance evaluation of an economic system creating increasingly intense and competitive. Thus, the energy concentration of the diet becomes more important definition to feed formulator, by directly impact profit activity by interactions with the density of nutrients. This allowed a better evaluation of profitability, the rate of energy performance for broilers, by incorporating the energy consumption formula, allowing more sensitivity to the new index (BEC). These data show that nonlinear feed formulation is a toll to offer new opportunities for poultry production to improved profitability.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The research activity described in this thesis is focused mainly on the study of finite-element techniques applied to thermo-fluid dynamic problems of plant components and on the study of dynamic simulation techniques applied to integrated building design in order to enhance the energy performance of the building. The first part of this doctorate thesis is a broad dissertation on second law analysis of thermodynamic processes with the purpose of including the issue of the energy efficiency of buildings within a wider cultural context which is usually not considered by professionals in the energy sector. In particular, the first chapter includes, a rigorous scheme for the deduction of the expressions for molar exergy and molar flow exergy of pure chemical fuels. The study shows that molar exergy and molar flow exergy coincide when the temperature and pressure of the fuel are equal to those of the environment in which the combustion reaction takes place. A simple method to determine the Gibbs free energy for non-standard values of the temperature and pressure of the environment is then clarified. For hydrogen, carbon dioxide, and several hydrocarbons, the dependence of the molar exergy on the temperature and relative humidity of the environment is reported, together with an evaluation of molar exergy and molar flow exergy when the temperature and pressure of the fuel are different from those of the environment. As an application of second law analysis, a comparison of the thermodynamic efficiency of a condensing boiler and of a heat pump is also reported. The second chapter presents a study of borehole heat exchangers, that is, a polyethylene piping network buried in the soil which allows a ground-coupled heat pump to exchange heat with the ground. After a brief overview of low-enthalpy geothermal plants, an apparatus designed and assembled by the author to carry out thermal response tests is presented. Data obtained by means of in situ thermal response tests are reported and evaluated by means of a finite-element simulation method, implemented through the software package COMSOL Multyphysics. The simulation method allows the determination of the precise value of the effective thermal properties of the ground and of the grout, which are essential for the design of borehole heat exchangers. In addition to the study of a single plant component, namely the borehole heat exchanger, in the third chapter is presented a thorough process for the plant design of a zero carbon building complex. The plant is composed of: 1) a ground-coupled heat pump system for space heating and cooling, with electricity supplied by photovoltaic solar collectors; 2) air dehumidifiers; 3) thermal solar collectors to match 70% of domestic hot water energy use, and a wood pellet boiler for the remaining domestic hot water energy use and for exceptional winter peaks. This chapter includes the design methodology adopted: 1) dynamic simulation of the building complex with the software package TRNSYS for evaluating the energy requirements of the building complex; 2) ground-coupled heat pumps modelled by means of TRNSYS; and 3) evaluation of the total length of the borehole heat exchanger by an iterative method developed by the author. An economic feasibility and an exergy analysis of the proposed plant, compared with two other plants, are reported. The exergy analysis was performed by considering the embodied energy of the components of each plant and the exergy loss during the functioning of the plants.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The general aim of this work is to contribute to the energy performance assessment of ventilated façades by the simultaneous use of experimental data and numerical simulations. A significant amount of experimental work was done on different types of ventilated façades with natural ventilation. The measurements were taken on a test building. The external walls of this tower are rainscreen ventilated façades. Ventilation grills are located at the top and at the bottom of the tower. In this work the modelling of the test building using a dynamic thermal simulation program (ESP-r) is presented and the main results discussed. In order to investigate the best summer thermal performance of rainscreen ventilated skin façade a study for different setups of rainscreen walls was made. In particular, influences of ventilation grills, air cavity thickness, skin colour, skin material, orientation of façade were investigated. It is shown that some types of rainscreen ventilated façade typologies are capable of lowering the cooling energy demand of a few percent points.