992 resultados para Enamel micromorphology


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article reports clinical procedures used to remove residual bonded resin and enamel stains following bracket debonding at the conclusion of orthodontic treatment. A water-cooled fine-tapered diamond bur was used for resin removal, followed by enamel surface finishing using a commercially available microabrasion paste. It was noted that residual tooth coloration remained yellowish because of enamel translucency; the yellow dentin shade showed through. Additional tooth shade lightening was achieved using carbamide peroxide dental bleaching solution in custom-formed trays. This report describes a safe and effective technique that optimizes tooth appearance at the conclusion of orthodontic therapy. Mechanical resin removal, enamel microabrasion, and tooth bleaching are employed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To review of the current status of enamel microabrasion method and its results 18 years after the development and application of this method. Methods: A technique performing enamel microabrasion with hydrochloric acid mixed with pumice and other techniques employing a commercially available compound of hydrochloric acid and fine-grit silicon carbide particles in a water-soluble paste have been described. Much has been learned about the application of this esthetic technique, long-term treatment results and microscopic changes to the enamel surface that has significant clinical implications. The latest treatment protocol is presented and photographic case histories document the treatment results. Clinical observations made over 18 years are discussed. Results: According to our findings, the dental enamel microabrasion technique is a highly satisfactory, safe and effective procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to investigate the penetration of a conventional adhesive material into enamel bleached with 16% carbamide peroxide and 38% hydrogen peroxide using optical light microscopy.Methods: Extracted human teeth were randomly divided into eight experimental groups with six specimens each, according to the bleaching material and time interval after bleaching and before the bonding procedure. Groups were designated as follows: control group, restorations in unbleached teeth; restorations performed immediately after bleaching; restorations performed 7 days after bleaching; restorations performed 14 days after bleaching; and restorations performed 30 days after bleaching. The length of resin tags was measured with an Axiophot photomicroscope at 400x magnification for the calculation of the proportion of tags of study groups compared to the respective control groups. Analysis of variance was applied for comparison between groups; data were transformed into arcsine (p < 0.05).Results: the specimens of experimental groups, in which restorations were performed 7, 14, and 30 days after bleaching, showed better penetration of adhesive material into enamel than specimens restored immediately after bleaching. There was no statistically significant difference between the bleaching materials employed or in the interaction between bleaching agent and time interval.Conclusions: This suggests that a time interval of at least 7 days should be allowed between enamel bleaching and placement of adhesive bonding agents for accomplishment of composite resin restorations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study's purpose was to assess the amount of dental enamel loss on primary incisors after manual or mechanical microabrasion with a phosphoric acid/pumice poste. Methods: Ten exfoliated primary maxillary incisors were bisected faciolingually and the resulting 20 halves were randomly assigned to 2 groups: group 1 (N=10) manual technique (plastic spatula); and group 2 (N=10) mechanical technique (rubber cup attached to a low-speed handpiece). Microabrasion was performed on the buccal surface using an abrasive paste prepared with 37% phosphoric acid and pumice. Ten 20-second applications alternated with 20-second risings were performed in each group. Enamel thickness measurements made under stereomi-croscopy before and after microabrasion were analyzed statistically by analysis of variance and pairwise t test. Results: There was a statistically significant difference (P=.003) between the manual and mechanical techniques. The mechanical technique produced a mean enamel loss of 274.16 mu m (66% of total enamel thickness), while the mean enamel loss with the manual technique was 152.59 mu m (39% of total enamel thickness). Conclusion: Manual microabrasion using a plastic spatula removed less enamel, but was sufficient to eliminate most superficial stains and defects, and may be a viable option for the microabrasive technique on primary teeth. (Pediatr Dent 2008;30:420-3) Received March 15, 2007 / Lost Revision September 19, 2007 / Revision Accepted October 19, 2007

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Predicting risk of posteruptive enamel breakdown (PEB) of molar-incisor hypomineralization (MIH) opacity is a difficult but important clinical task. Therefore, there is a need to evaluate these aspects through longitudinal studies.Objective. The aim of this longitudinal study was to analyse the relationship between colours of MIH opacity of children aged 6-12 (baseline) and other clinical and demographic variables involved in the increase in severity of MIH.Materials and methods. A blinded prospective 18-month follow-up was conducted with 147 individuals presenting mild MIH. Tooth-based incidence of increase in severity of MIH (PEB or atypical restorations) was used as dependent measurement. Enamel opacities were recorded according to colour shades of white, yellow and brown, allowing assessment of susceptibility to structural loss over time, according to colour of MIH opacity. Poisson regression models were used to adjust the results for demographic and clinical variables.Results. Brown and yellow MIH opacities were at higher risk for PEB and atypical restorations than those of white ones, even after adjustment for clinical and demographic variables.Conclusion. Teeth presenting mild MIH severity associated with yellow and brown enamel opacities were at high risk for increase in severity of MIH than lighter ones. This result could help clinicians determine a risk-based treatment for children with MIH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the trans-enamel and trans-dentinal cytotoxic effects of a 35% H2O2 bleaching gel on an odontoblast-like cell lines (MDPC-23) after consecutive applications.Fifteen enamel/dentine discs were obtained from bovine central incisor teeth and placed individually in artificial pulp chambers. Three groups (n = 5 discs) were formed according to the following enamel treatments: G1: 35% H2O2 bleaching gel (15 min); G2: 35% H2O2 bleaching gel (15 min) + halogen light (20 s); G3: control (no treatment). After repeating the treatments three consecutive times, the extracts (culture medium + gel components that had diffused through enamel/dentine discs) in contact with the dentine were collected and applied to previously cultured MDPC-23 cells (50 000 cells cm(-2)) for 24 h. Cell metabolism was evaluated by the MTT assay and data were analysed statistically (alpha = 5%; Kruskal-Wallis and Mann-Whitney U-test). Cell morphology was analysed by scanning electron microscopy.Cell metabolism decreased by 92.03% and 82.47% in G1 and G2 respectively. G1 and G2 differed significantly (P < 0.05) from G3. Regardless of halogen light activation, the application of the bleaching gel on the cultured odontoblast-like cells caused significantly more severe cytotoxic effects than those observed in the nontreated control group. In addition, significant morphological cell alterations were observed in G1 and G2.After three consecutive applications of a 35% H2O2 bleaching agent, the diffusion of the gel components through enamel and dentine caused severe toxic effects to cultured pulp cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the efficacy of the laser fluorescence (LF) device in detecting in vitro demineralization and remineralization of smooth surface caries-like lesions. Background Data: The early detection of smooth surface caries-like lesions is important to provide proper management of carious lesions, and allows monitoring of them over time. Also, some authors suggest that LF could be useful in monitoring the caries pathological process. Materials and Methods: Seventy-eight blocks of bovine teeth were obtained, and then submitted to artificial caries lesion induction and to a pH-cycling process. Superficial microhardness (SMH) and laser fluorescence analysis were performed at baseline, after induction of caries-like lesions, and after the pH-cycling regimen to promote remineralization. Results: Friedman's and multiple comparison tests were performed for all variables. SMH analysis showed significant differences (p < 0.05) between baseline (286.77 +/- 1.49 Vickers hardness number [VHN] units), before (38.48 +/- 0.85 VHN), and after remineralization (131.93 +/- 2.63 VHN). Baseline values for LF were extremely low (2.71 +/- 0.05), and a statistically significant difference was observed only after remineralization (3.61 +/- 0.08), as demonstrated by the increase in LF values. Conclusion: The LF device did not show efficacy for monitoring in vitro demineralization and remineralization of smooth enamel surfaces.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gingival recession was created in six mongrel dogs. The dogs were divided into two groups based on treatment: group 1-AlloDerm only, group 2-AlloDerm + Emdogain. The histologic results were compared. At the end of the study, the mean values were, for groups I and 2, respectively: 0.06 and 0.32 mm for cementum regeneration; -0.75 and -0.86 mm for bone regeneration; -2.15 and -3.11 mm for attachment level; and 4.90 and 5.51 mm for defect extent. The epithelial formation parameter was 2.88 mm in group 1 and 2.15 mm in group 2, which was a statistically significant difference. It could be concluded that Emdogain did not result in beneficial effects when associated with AlloDerm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the influence of different light sources for in-office bleaching on surface microhardness of human enamel. One hundred and five blocks of third molars were distributed among seven groups. The facial enamel surface of each block was polished and baseline Knoop microhardness of enamel was assessed with a load of 25 g for 5 s. Subsequently, the enamel was treated with 35% hydrogen peroxide bleaching agent and photo-activated with halogen light (group A) during 38 s, LED (group B) during 360 s, and high intensity diode laser (group C) during 4 s. The groups D (38 s), E (360 s), and F (4 s) were treated with the bleaching agent without photo-activated. The control (group G) was only kept in saliva without any treatment. Microhardness was reassessed after 1 day of the bleaching treatment, and after 7 and 21 days storage in artificial saliva. The mean percentage and standard deviation of microhardness in Knoop Hardness Number were: A 97.8 +/- 13.1 KHN; B 95.5 +/- 12.7 KHN; C 84.2 +/- 13.6 KHN; D 128.6 +/- 20.5 KHN; E 133.9 +/- 14.2 KHN; F 123.9 +/- 14.2 KHN; G 129.8 +/- 18.8 KHN. Statistical analysis (p < 0.05; Tukey test) showed that microhardness percentage values were significantly lower in the groups irradiated with light when compared with the non-irradiated groups. Furthermore, the non-irradiated groups showed that saliva was able to enhance the microhardness during the measurement times. The enamel microhardness was decreased when light sources were used during the bleaching process and the artificial saliva was able to increase microhardness when no light was used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated comparatively by scanning electron microscopy (SEM) the effect of different dental conditioners on dentin micromorphology, when used according to the same protocol. Forty dentin sticks were obtained from 20 caries-free third human molars and were assigned to 4 groups corresponding to 3 conditioners (phosphoric acid 37%, Clearfil SE Bond and iBond) and an untreated control group. After application of the conditioners, the specimens were immersed in 50% ethanol solution during 10 s, chemically fixed and dehydrated to prepare them to SEM analysis. In the control group, dentin surface was completely covered by smear layer and all dentinal tubules were occluded. In the phosphoric acid-etched group, dentin surface was completely clean and presented exposed dentinal tubule openings; this was the only group in which the tubules exhibited the funnel-shaped aspect. In the groups conditioned with Clearfil SE Bond primer and iBond, which are less acidic than phosphoric acid, tubule openings were occluded or partially occluded, though smear layer removal was observed. SE Bond was more efficient in removing the smear layer than iBond. In the Clearfil SE Bond group, the cuff-like aspect of peritubular dentin was more evident. It may be concluded all tested conditioners were able to change dentin morphology. However, it cannot be stated that the agent aggressiveness was the only cause of the micromorphological alterations because a single morphological pattern was not established for each group, but rather an association of different aspects, according to the aggressiveness of the tested conditioner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different secondary caries models may present different results. The purpose of this study was to compare different in vitro secondary caries models, evaluating the obtained results by polarized-light microscopy (PLM), scanning electron microscopy (SEM), and energy dispersive X-ray spectroscopy (EDS). Standardized human enamel specimens (n = 12) restored with different materials (Z250 conventional composite resin-CRZ, Freedom polyacid-modified composite resin-CRF, Vitremer resin-modified glass-ionomer-GIV, and Fuji IX conventional glass-ionomer cement-GIF) were submitted to microbiological (MM) or chemical caries models (CM). The control group was not submitted to any caries model. For MM, specimens were immersed firstly in sucrose broth inoculated with Streptococcus mutans ATCC 35688, incubated at 37 degrees C/5% CO(2) for 14 days and then in remineralizing solution for 14 days. For CM, specimens were submitted to chemical pH-cycling. Specimens were ground, submitted to PLM and then were dehydrated, gold-sputtered and submitted to SEM and EDS. Results were statistically analyzed by Kruskall-Wallis and Student-Newman-Keuls tests (alpha = 0.05). No differences between in vitro caries models were found. Morphological differences in enamel demineralization were found between composite resin and polyacid-modified composite resin (CRZ and CRF) and between the resin-modified glass-ionomer and the glass-ionomer cement (GIF and GIV). GIF showed higher calcium concentration and less demineralization, differing from the other materials. In conclusion, the glass-ionomer cement showed less caries formation under both in vitro caries models evaluated. (C) 2009 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 90B: 635-640, 2009