965 resultados para Electric energy


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Based on the report for the unit “Project IV” of the PhD programme on Technology Assessment under the supervision of Dr.-Ing. Marcel Weil and Prof. Dr. António Brandão Moniz. The report was presented and discussed at the Doctorate Conference on Technologogy Assessment in July 2013 at the University Nova Lisboa, Caparica campus.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

To find sustainable solutions for the production of energy, it is necessary to create photovoltaic technologies that make every photon count. To pursue this necessity, in the present work photodetectors of zinc oxide embedded with nano-structured materials, that significantly raise the conversion of solar energy to electric energy, were developed. The novelty of this work is on the development of processing methodologies in which all steps are in solution: quantum dots synthesis, passivation of their surface and sol-gel deposition. The quantum dot solutions with different capping agents were characterized by UVvisible absorption spectroscopy, spectrofluorimetry, dynamic light scattering and transmission electron microscopy. The obtained quantum dots have dimensions between 2 and 3nm. These particles were suspended in zinc acetate solutions and used to produce doped zinc oxide films with embedded quantum dots, whose electric response was tested. The produced nano-structured zinc oxide materials have a superior performance than the bulk, in terms of the produced photo-current. This indicates that an intermediate band material should have been produced that acts as a photovoltaic medium for solar cells. The results are currently being compiled in a scientific article, that is being prepared for possible submission to Energy and Environmental Science or Nanoscale journals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Eletrónica Industrial e de Computadores

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia Civil

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aquest projecte realitza una auditoria ambiental de l’edifici de l’Àrea de Territori, Medi Ambient, Paisatge i Espai Urbà de l’Ajuntament de Sitges, com a primer pas per a la implantació d’un sistema de gestió ambiental (SGA), en acord amb el Reglament (CE) nº 761/2001, i la posterior obtenció d’un certificat de gestió i auditories ambientals (EMAS). L’auditoria s’inicia amb la identificació dels aspectes ambientals de l’edifici, mitjançant la recopilació de dades sobre consums energètics i hídrics, la estimació de la generació de residus i enquestes de mobilitat als treballadors. Aquestes dades són utilitzades per determinar els aspectes ambientals significatius i posteriorment, exposar una sèrie de propostes de millora per tal de corregir-los o minimitzar-los, com ara sistemes d’estalvi d’aigua, d’enllumenat, de producció d’electricitat i l’educació ambiental dels treballadors. Per a la implantació d’un SGA en la situació actual de l’edifici, es necessària, entre altres coses, la implantació d’un sistema de registre que arxivi els consums d’aigua, energia i generació de residus, per tal de dur un control de les despeses de cadascun dels vectors. A més, caldrà implementar un Programa de bones pràctiques ambientals en l’oficina per tal de reduir el consum elèctric, d’aigua i generació de residus, i la seva classificació per part dels treballadors.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Some demographic and epidemiological patterns of the rural population of Monte Negro, locality situated in the State of Rondônia (Brazil), Western Amazonia, are described based on a sample of 924 randomly selected individuals, approximately 10% of the whole population. The main features of this sample are (1) the illiteracy rates in the parental generation were 23% for fathers and 20% for mothers. Among children, this figure dropped to 6%; (2) housing in Monte Negro is characterized by being constructed with wood (92%), and also a floor (75%). Nevertheless, only 32% of these houses had electric energy; (3) the mean ages for the parental generation were 41.9 for males and 36.3 for females. These values for the offspring generation were 12.2 and 10.5, respectively; (4) the sex-ratio of the offspring generation was 1.32;(5) the bioassay of kinship was estimated as .033 for this long range migrant population; (6) the prevalence of some macrophage dependent infectious disease was conspicuously high; (7) the reported number of malarial episodes among males and females was statistically different, suggesting that malaria may be, in part, a "professional" disease; (8) the prevalence of serum-positive reactions against B-hepatitis is distressing. It has a strong age dependence and reaches 74% among adult males. Conversely, signs of active infection (AgHbs) rises to 16% among children.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

En aquest projecte es pretén implementar un dispositiu capaç de ser auto-suficient i no dependre de cap tipus de pila, bateria o fil elèctric que l’abasteixi d’energia elèctrica. El dispositiu recol·lectarà la energia magnètica generada per la corrent elèctrica a un fil i la transformarà en energia elèctrica, que serà emmagatzemada per el seu posterior ús. A demès, aquest projecte s’ha desenvolupat en col·laboració amb un segon projecte, dintre del qual s’implementarà una xarxa de sensors, mitjançant el protocol MIWI. Aquest projecte es divideix en tres grans blocs. El primer bloc del projecte serà una introducció teòrica de tots els coneixements relacionats amb el concepte d’energy harvesting i els mecanismes físic implicats. Al segon bloc podrem veure com s’han realitzat els càlculs, simulacions i posada en marxa, dels diferents elements que formaran el dispositiu recol·lector d’energia. Per últim en el tercer bloc veurem el prototip ja implementat. Es valoraran els resultats obtinguts, i es veuran els temps que necessitarà per alimentar al microcontrolador.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In distributed energy production, permanent magnet synchronous generators (PMSG) are often connected to the grid via frequency converters, such as voltage source line converters. The price of the converter may constitute a large part of the costs of a generating set. Some of the permanent magnet synchronous generators with converters and traditional separately excited synchronous generators couldbe replaced by direct-on-line (DOL) non-controlled PMSGs. Small directly networkconnected generators are likely to have large markets in the area of distributed electric energy generation. Typical prime movers could be windmills, watermills and internal combustion engines. DOL PMSGs could also be applied in island networks, such as ships and oil platforms. Also various back-up power generating systems could be carried out with DOL PMSGs. The benefits would be a lower priceof the generating set and the robustness and easy use of the system. The performance of DOL PMSGs is analyzed. The electricity distribution companies have regulations that constrain the design of the generators being connected to the grid. The general guidelines and recommendations are applied in the analysis. By analyzing the results produced by the simulation model for the permanent magnet machine, the guidelines for efficient damper winding parameters for DOL PMSGs are presented. The simulation model is used to simulate grid connections and load transients. The damper winding parameters are calculated by the finite element method (FEM) and determined from experimental measurements. Three-dimensional finite element analysis (3D FEA) is carried out. The results from the simulation model and 3D FEA are compared with practical measurements from two prototype axial flux permanent magnet generators provided with damper windings. The dimensioning of the damper winding parameters is case specific. The damper winding should be dimensioned based on the moment of inertia of the generating set. It is shown that the damper winding has optimal values to reach synchronous operation in the shortest period of time after transient operation. With optimal dimensioning, interferenceon the grid is minimized.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Diplomityössä tarkasteltiin lentoaseman terminaalirakennuksen energia- ja ainevirtoja sekä sisäilman ominaisuuksia. Esimerkkikohteena oli Helsinki-Vantaan lentoaseman keskiterminaalirakennus, jonka 1. ja 2. rakennusvaiheen ulkovaippa muodosti taserajan. Taseen ulkopuolisista tekijöistä tarkasteltiin jäähdytysenergian tuotantoa ja ulkoilman laatua. Työn yhtenä tavoitteena oli muodostaa rakennukselle energiatase. Taseen avulla saatiin tietoa energian jakautumisesta eri toimintoihin ja löydettiin tekijät, joita suunnittelussa tulee painottaa. Terminaalin lähiympäristössä tutkittiin ulkoilman laatua mittausten avulla. Mittaustietoja käytetään apuna tulevaisuuden ilmanottosuunnittelussa. Työssä tarkasteltiin energia- ja ainevirtoina lämpö-, jäähdytys- ja sähköenergian sekä veden ostoa, tuotantoa ja kulutusta sekä prosessointia. Terminaalin lämpötarpeesta hieman yli puolet katettiin kaukolämmöllä. Loput noin 45 % lämpöenergiasta saatiin ns. ilmaisenergioista. Näistä merkittävimmäksi havaittiin sähkölaitteiden luovuttama lämpömäärä. Lämpöhäviöiden kannalta merkittäviä energiavirtoja olivat ilmanvaihdon ja vuotoilmojen kautta siirtyvät energiavirrat, joiden osuuden todettiin olevan noin 80 % terminaalin kokonaislämpöhäviöistä. Vaipan lämmöneristyskyky ja kyky absorboida auringon säteilyä todettiin hyviksi. Tulevaisuudessa tärkeitä suunnittelunäkökohtia tulevat olemaan ilmanvaihdon ja vuotoilman kautta siirtyvien energiavirtojen hallinta sekä sähköenergian ominaiskulutuksen pienentäminen. Ulkoilma todettiin mittauksin hyvätasoiseksi. Lento- ja maaliikenteen päästöarvot olivat lähellä toisiaan ja selvästi ohjearvoja alemmalla tasolla. Päästöjen sijaintiin vaikuttivat liikennemääriä enemmän tuuliolosuhteet. Tulevaisuudessa tuloilma voidaan johtaa terminaaliin yhtä hyvin joko lento- tai maaliikenteen puolelta.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Nowadays the Finnish-Russian electric energy interaction is carried out through the back-to-back DC Vyborg substation and several power plants working synchronously with Finnish power system. Constant amount of energy flows in one direction — from Russia to Finland. But the process of electricity market development in Russian energy system makes the new possibilities of electrical cooperation available. The goal of master's thesis is to analyze the current state and possible evolution trends of North-West Russian system in relation with future possible change in power flow between Russia and Finland. The research is done by modelling the market of North-West Russia and examination of technical grid restrictions. The operational market models of North-West region of Russia for the years 2008 and 2015 were created during the research process. The description of prepared market models together with modelling results and their analysis are shown in the work. The description of power flow study process and results are also presented.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A system for disposal and recovery of the main effluents and chemical waist from isotope separation plants and enriched compounds-15N and 34S production has been carried out at the Stable Isotope Laboratory (LIE) of the CENA/USP. Around four hundred thousand liters of effluents has been recovered yearly. Among the recovered chemical wastes, the more relevant are: ammonia; brome; ammonium and sodium sulfate; sodium hydroxide; sulfur dioxide; and hydrochloric acid. Chemical wastes containg recoverable heavy metals (Ag, Cr and Cu) and solvents (methanol, ethanol and acetone) are processed and recovered. Gaseous emissions, mainly H2S are used for recovery of heavy metals solutions. The minimization of the residues waters, as well the reduction of electric energy consume was established using a water deionization system. A cost/effect balance of the process is reported.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The influence of natural aging furthered by atmospheric corrosion of parts of electric transformers and materials, as well as of concrete poles and cross arms containing corrosion inhibitors was evaluated in Manaus. Results for painted materials, it could showed that loss of specular gloss was more intensive in aliphatic polyurethane points than in acrylic polyurethane ones. No corrosion was observed for metal and concrete samples until 400 days of natural aging. Corrosion in steel reinforcement was noticed in some poles, arising from manufacturing faults, such as low cement content, water/cement ratio, thin concrete cover thickness, etc. The performance of corrosion inhibitors was assessed by many techniques after natural and accelerated aging in a 3.5% saline aqueous solution. The results show the need for better chemical component selection and its concentration in the concrete mixture.