854 resultados para Drug-monitoring systems


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a robust assay based on MEKC for cefepime in human serum and plasma with internal quality assurance is reported. Sample preparation comprises protein precipitation in the presence of SDS at pH 4.5. This is a gentle approach for which decomposition of cefepime during sample handling is negligible. After hydrodynamic sample injection of the supernatant, analysis occurs in a phosphate/borate buffer at pH 9.1 with 75 mM SDS using normal polarity and analyte detection at 257 nm. The MEKC run time interval and throughput are about 5 min and seven samples per hour, respectively. The calibration range for cefepime is 1-60 μg/mL, with 1 μg/mL being the LOQ. The performance of the assay with multilevel internal calibration was assessed with calibration and control samples. The assay is shown to be simple, inexpensive, reproducible, and robust. It was applied to determine cefepime levels in the sera of critically ill patients and to assess the instability of cefepime in patient and control samples. Our data revealed that serum containing cefepime can be stored at -20°C for a short time, whereas for long-term storage, samples have to be kept at -70°C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New directly acting antivirals (DAAs) that inhibit hepatitis C virus (HCV) replication are increasingly used for the treatment of chronic hepatitis C. A marked pharmacokinetic variability and a high potential for drug-drug interactions between DAAs and numerous drug classes have been identified. In addition, ribavirin (RBV), commonly associated with hemolytic anemia, often requires dose adjustment, advocating for therapeutic drug monitoring (TDM) in patients under combined antiviral therapy. However, an assay for the simultaneous analysis of RBV and DAAs constitutes an analytical challenge because of the large differences in polarity among these drugs, ranging from hydrophilic (RBV) to highly lipophilic (telaprevir [TVR]). Moreover, TVR is characterized by erratic behavior on standard octadecyl-based reversed-phase column chromatography and must be separated from VRT-127394, its inactive C-21 epimer metabolite. We have developed a convenient assay employing simple plasma protein precipitation, followed by high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) for the simultaneous determination of levels of RBV, boceprevir, and TVR, as well as its metabolite VRT-127394, in plasma. This new, simple, rapid, and robust HPLC-MS/MS assay offers an efficient method of real-time TDM aimed at maximizing efficacy while minimizing the toxicity of antiviral therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE Therapeutic drug monitoring of patients receiving once daily aminoglycoside therapy can be performed using pharmacokinetic (PK) formulas or Bayesian calculations. While these methods produced comparable results, their performance has never been checked against full PK profiles. We performed a PK study in order to compare both methods and to determine the best time-points to estimate AUC0-24 and peak concentrations (C max). METHODS We obtained full PK profiles in 14 patients receiving a once daily aminoglycoside therapy. PK parameters were calculated with PKSolver using non-compartmental methods. The calculated PK parameters were then compared with parameters estimated using an algorithm based on two serum concentrations (two-point method) or the software TCIWorks (Bayesian method). RESULTS For tobramycin and gentamicin, AUC0-24 and C max could be reliably estimated using a first serum concentration obtained at 1 h and a second one between 8 and 10 h after start of the infusion. The two-point and the Bayesian method produced similar results. For amikacin, AUC0-24 could reliably be estimated by both methods. C max was underestimated by 10-20% by the two-point method and by up to 30% with a large variation by the Bayesian method. CONCLUSIONS The ideal time-points for therapeutic drug monitoring of once daily administered aminoglycosides are 1 h after start of a 30-min infusion for the first time-point and 8-10 h after start of the infusion for the second time-point. Duration of the infusion and accurate registration of the time-points of blood drawing are essential for obtaining precise predictions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the multiple case-study was to determine how hospital subsystems (such as physician monitoring and credentialing; quality assurance; risk management; and peer review) were supporting the monitoring of physicians? Three large metropolitan hospitals in Texas were studied and designated as hospitals #1, #2, and #3. Realizing that hospital subsystems are a unique entity and part of a larger system, conclusions were made on the premises of a quality control system, in relation to the tools of government (particularly the Health Care Quality Improvement Act (HCQIA)), and in relation to itself as a tool of a hospital.^ Three major analytical assessments were performed. First, the subsystems were analyzed as to their "completeness"; secondly, the subsystems were analyzed for "performance"; and thirdly, the subsystems were analyzed in reference to the interaction of completeness and performance.^ The physician credentialing and monitoring and the peer review subsystems as quality control systems were most complete, efficient, and effective in hospitals #1 and #3. The HCQIA did not seem to be an influencing factor in the completeness of the subsystem in hospital #1. The quality assurance and risk management subsystem in hospital #2 was not representative of completeness and performance and the HCQIA was not an influencing factor in the completeness of the Q.A. or R.M. systems in any hospital. The efficiency (computerization) of the physician credentialing, quality assurance and peer review subsystems in hospitals #1 and #3 seemed to contribute to their effectiveness (system-wide effect).^ The results indicated that the more complete, effective, and efficient subsystems were characterized by (1) all defined activities being met, (2) the HCQIA being an influencing factor, (3) a decentralized administrative structure, (4) computerization an important element, and (5) staff was sophisticated in subsystem operations. However, other variables were identified which deserve further research as to their effect on completeness and performance of subsystems. They include (1) medical staff affiliations, (2) system funding levels, (3) the system's administrative structure, and (4) the physician staff "cultural" characteristics. Perhaps by understanding other influencing factors, health care administrators may plan subsystems that will be compatible with legislative requirements and administrative objectives. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The improvement and performance of a micellar electrokinetic capillary chromatography assay for cefepime in human serum and plasma with a 50 μm id fused-silica capillary elongated from 40 to 60 cm is reported. Sample preparation with dodecylsulfate protein precipitation at pH 4.5, the pH 9.1 separation medium and the applied voltage were as reported previously[16]. The change resulted in a significant lower current, higher resolution and increased detection time intervals. The performance of the assay with multi-level internal calibration was assessed with calibration and control samples. Quality assurance data of a two year period assessed under the new conditions demonstrated the robustness of the assay. In serum samples of patients who received both cefepime and sulfamethoxazole, cefepime could not be detected due to the inseparability of the two compounds. The presence of an interference can be recognized by an increased peak width (width > 0.2 min), the appearance of a shoulder or an unresolved double peak. The patient data gathered during a three year period reveal that introduction of therapeutic drug monitoring led to a 50% reduction of the median drug level. The data suggest that therapeutic drug monitoring can help to minimize the risk of major adverse reactions and to increase drug safety on an individual basis. This article is protected by copyright. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"March 1990."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Prepared under contract no. HSM 110-70-406.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper investigates the input-output characteristics of structural health monitoring systems for composite plates based on permanently attached piezoelectric transmitter and sensor elements. Using dynamic piezoelectricity theory and a multiple integral transform method to describe the propagating and scattered flexural waves an electro-mechanical model for simulating the voltage input-output transfer function for circular piezoelectric transmitters and sensors adhesively attached to an orthotropic composite plate is developed. The method enables the characterization of all three physical processes, i.e. wave generation, wave propagation and wave reception. The influence of transducer, plate and attached electrical circuit characteristics on the voltage output behaviour of the system is examined through numerical calculations, both in frequency and the time domain. The results show that the input-output behaviour of the system is not properly predicted by the transducers' properties alone. Coupling effects between the transducers and the tested structure have to be taken into account, and adding backing materials to the piezoelectric elements can significantly improve the sensitivity of the system. It is shown that in order to achieve maximum sensitivity, particular piezoelectric transmitters and sensors need to be designed according to the structure to be monitored and the specific frequency regime of interest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. Methods: First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21degreesC) and time (1 h at similar to300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. Results: The mean error scores for SRM and PT factory calibration over a range of 50-1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however. power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. Conclusions: When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.