118 resultados para Drills


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to evaluate the effect of Er:YAG (L) and diamond drills (DD) on: 1) the microshear bond strength (MPa); 2) the adhesive interface of two-step (TS) – Adper Scotchbond Multipurpose and one-step (OS) adhesives – Adper EasyOne, both from 3M ESPE. Material and methods: According to the preparation condition and adhesives, the samples were divided into four groups: DD_TS (control); DD_OS; L_TS and L_OS. 60 bovine incisors were randomly divided into experimental and groups: 40 for microshear bond strength (n = 10) and 20 for the adhesive interface morphology [6 to measure the thickness of the hybrid layer (HL) and length of tags (t) by CLSM (n = 3); 12 to the adhesive interface morphology by SEM (n = 3) and 2 to illustrate the effect of the instruments on dentine by SEM (n = 1)]. To conduct the microshear bond strength test, four cylinders (0.7 mm in diameter and 1 mm in height with area of adhesion of 0.38 mm) were constructed with resin composite (Filtek Z350 XT – 3M ESPE) on each dentin surface treated by either L or DD and after adhesives application. Microshear bond strength was performed in universal testing machine (EMIC 2000) with load cell of 500 kgf and a crosshead speed of 0.5 mm / min. Adhesive interface was characterized by thickness of hybrid layer (HL) and length of tags (t) in nm, with the aid of UTHSCSA ImageTool software. Results: Microshear bond strength values were: L_TS 34.10 ± 19.07, DD_TS 24.26 ± 9.35, L_OS 33.18 ± 12.46, DD_OS 21.24 ± 13.96. Two-way ANOVA resulted in statistically significant differences only for instruments (p = 0.047). Mann-Whitney identified the instruments which determined significant differences for HL thickness and tag length (t). Concerning to the adhesive types, these differences were only observed for (t). Conclusion: It can be concluded that 1) laser Er:YAG results in higher microshear bond strength values regardless of the adhesive system (TS and OS); 2) the tags did not significant affect the microshear bond strength; 3) the adhesive interface was affected by both the instruments for cavity preparation and the type of adhesive system used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Ciência do Solo) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ObjectiveTo compare peri-implant tissue healing at implants installed in sites prepared with conventional drills or a sonic device.Material and methodsIn six Beagle dogs, the mandibular premolars and first molars were extracted bilaterally. After 3 months, full-thickness muco-periosteal flaps were elevated and recipient sites were prepared in both sides of the mandible. In the right side (control), the osteotomies were prepared using conventional drills, while, at the left side (test), a sonic device (Sonosurgery((R))) was used. Two implants were installed in each side of the mandible. After 8weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation.ResultsThe time consumed for the osteotomies at the test was more than double compared to the conventional control sites. No statistically significant differences were found for any of the histological variables evaluated for hard and soft tissue dimensions. Although not statistically significant, slightly higher mineralized bone-to-implant contact was found at the test (65.4%) compared to the control (58.1) sites.ConclusionsSimilar healing characteristics in osseointegration and marginal hard tissue remodeling resulted at implants installed into osteotomies prepared with conventional drills or with the sonic instrument (Sonosurgery((R))).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To compare peri-implant soft- and hard-tissue integration at implants installed juxta- or sub-crestally. Furthermore, differences in the hard and soft peri-implant tissue dimensions at sites prepared with drills or sonic instruments were to be evaluated. Three months after tooth extraction in six dogs, recipient sites were prepared in both sides of the mandible using conventional drills or a sonic device (Sonosurgery(®) ). Two implants with a 1.7-mm high-polished neck were installed, one with the rough/smooth surface interface placed at the level of the buccal bony crest (control) and the second placed 1.3 mm deeper (test). After 8 weeks of non-submerged healing, biopsies were harvested and ground sections prepared for histological evaluation. The buccal distances between the abutment/fixture junction (AF) and the most coronal level of osseointegration (B) were 1.6 ± 0.6 and 2.4 ± 0.4 mm; between AF and the top of the bony crest (C), they were 1.4 ± 0.4 and 2.2 ± 0.2 mm at the test and control sites, respectively. The top of the peri-implant mucosa (PM) was located more coronally at the test (1.2 ± 0.6 mm) compared to the control sites (0.6 ± 0.5 mm). However, when the original position of the bony crest was taken into account, a higher bone loss and a more apical position of the peri-implant mucosa resulted at the test sites. The placement of implants into a sub-crestal location resulted in a higher vertical buccal bone resorption and a more apical position of the peri-implant mucosa in relation to the level of the bony crest at implant installation. Moreover, peri-implant hard-tissue dimensions were similar at sites prepared with either drills or Sonosurgery(®) .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Apical surgeries are part of a segment of root canal treatment by which we can correct or eliminate iatrogenic deficiencies arising from conventional endodontic treatment. Currently no consensus among authors regarding to the factors linked to the surgery success as the execution of an apex resection followed by retropreparation and retrofilling. The apex resection performed 3mm from apical vertex allows the elimination of most apical ramifications, and it is a consensus part of the treatment. The preparation of cavities using ultrasonic tips has advantages over those made with drills such as better cleaning of the cavity, the possibility of lower cutting angle of the apical resection and deeper retropreparation. Another detail to consider is the type of tip, since the diamond tips in a more angulated inclination have higher cutting efficiency but causing increased formation of debris on the dentin walls. Finally, filling the cavity with an apical filling material allows proper sealing of the intracanal contents favoring apical healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nine swines of the White Large race were used for study of the process of bony repair after osteotomy with rotating instruments of low and high-speed, with and without liquid refrigeration. The authors observed, through double blind histopathological analysis, that in every analyzed operative time, the bony repair was processed more appropriately when the osteotomies were accomplished with liquid refrigeration. In the final postoperative times, of fourteen and twenty-eight days, the best results of bony repair were observed in the osteotomy accomplished with drills of low rotation and with liquid refrigeration, while in the postoperative time of seven days, the results of the bony repair of osteotomy accomplished with drills of high rotation and with liquid refrigeration they were better. The authors consider, still, that the process of bony repair in swine display larger proximity in the histological pictures among the studied variables, when compared with other biological models. As most of the works told in the literature it refers the use of dogs, the authors consider that the present work guarantees your importance in the sense of looking for a closer model of the man.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Produção Vegetal) - FCAV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: A growing interest to preserve teeth into the mouth by patients resulted in the increasing number of endodontic retreatments, and when these happen, many different types of irritants are extruded through the foramen. Objective: This study analyzed in vitro the amount of debris extruded through the foramen using four instrumentation techniques during endodontic retreatment. Material and methods: Forty mesial-buccal roots of first molars were selected, instrumented with anatomical diameter up to size #30 ISO file and then obturated with gutta-percha and grossman sealer by lateral condensation. After, they were separated and randomly allocated into four groups with 10 teeth each for the endodontic retreatment procedure: G1 – conventional technique + solvent, G2 – conventional technique without solvent, G3 – ProTaper retreatment + solvent, G4 – ProTaper retreatment without solvent. In all groups, gutta-percha in the coronal portion was removed by using size 1-3 Gates Glidden drills. All teeth were irrigated with distilled water. The debris extruded through the foramen were collected and weighed by an analytical balance. Results: Group 4 had the lowest average for material extrusion through the foramen followed by groups 2, 3 and 1. When Tukey test for statistical analysis was applied, no significant difference among groups were found (p = 0.5664). Conclusion: We conclude that all instrumentation techniques used in this study produced debris which goes beyond the foramen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The laser driven ion acceleration is a burgeoning field of resarch and is attracting a growing number of scientists since the first results reported in 2000 obtained irradiating thin solid foils by high power laser pulses. The growing interest is driven by the peculiar characteristics of the produced bunches, the compactness of the whole accelerating system and the very short accelerating length of this all-optical accelerators. A fervent theoretical and experimental work has been done since then. An important part of the theoretical study is done by means of numerical simulations and the most widely used technique exploits PIC codes (“Particle In Cell'”). In this thesis the PIC code AlaDyn, developed by our research group considering innovative algorithms, is described. My work has been devoted to the developement of the code and the investigation of the laser driven ion acceleration for different target configurations. Two target configurations for the proton acceleration are presented together with the results of the 2D and 3D numerical investigation. One target configuration consists of a solid foil with a low density layer attached on the irradiated side. The nearly critical plasma of the foam layer allows a very high energy absorption by the target and an increase of the proton energy up to a factor 3, when compared to the ``pure'' TNSA configuration. The differences of the regime with respect to the standard TNSA are described The case of nearly critical density targets has been investigated with 3D simulations. In this case the laser travels throughout the plasma and exits on the rear side. During the propagation, the laser drills a channel and induce a magnetic vortex that expanding on the rear side of the targer is source of a very intense electric field. The protons of the plasma are strongly accelerated up to energies of 100 MeV using a 200PW laser.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technical complications in implant prosthetic cases represent a major challenge in dentistry. This case report describes minimally invasive management to recover an implant with a fractured remnant of a zirconia abutment, including provisional rehabilitation during a sequential treatment protocol in the esthetic zone. A patient was treated with a screw-retained one-piece implant-supported reconstruction made of a customized zirconia abutment with direct ceramic veneering in the maxillary right central incisor position. During the prosthetic try-in, a fracture in the apical portion of the abutment was evident. The first rescue attempt led to fracture of the retrieval instrument. Immediately, an individualized wired construction was applied to bond the existing fractured reconstruction to the neighboring teeth to maintain the peri-implant mucosal architecture. Because the implant screw canal was blocked, a customized round bur had to be manufactured and was placed in the implant axis with a specific bracket tool from the service set to protect the interior implant threads. Then, the drills of the service set were guided by the newly created access to remove the fractured remnants. The implant screw was retapped and the area rinsed with chlorhexidine solution. All remnants were removed without the need for surgical intervention. Neither the implant connection nor the bone-to-implant interface was damaged. The stepwise treatment approach with the customized round bur combined with the system-specific drills of the service set saved the blocked implant so that the patient could be successfully rehabilitated with a new implant reconstruction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In public health preparedness, disaster preparedness refers to the strategic planning of responses to all types of disasters. Preparation and training for disaster response can be conducted using different teaching modalities, ranging from discussion-based programs such as seminars, drills and tabletop exercises to more complex operation-based programs such as functional exercises and full-scale exercises. Each method of instruction has its advantages and disadvantages. Tabletop exercises are facilitated discussions designed to evaluate programs, policies, and procedures; they are usually conducted in a classroom, often with tabletop props (e.g. models, maps or diagrams). ^ Objective. The overall goal of this project was to determine whether tabletop exercises are effective teaching modalities for disaster preparedness, with an emphasis on intentional chemical exposure. ^ Method. The target audience for the exercise was the Medical Reserve Brigade of the Texas State Guard, a group of volunteer healthcare providers and first responders who prepare for response to local disasters. A new tabletop exercise was designed to provide information on the complex, interrelated organizations within the national disaster preparedness program that this group would interact with in the event of a local disaster. This educational intervention consisted of a four hour multipart program that included a pretest of knowledge, lecture series, an interactive group discussion using a mock disaster scenario, a posttest of knowledge, and a course evaluation. ^ Results. Approximately 40 volunteers attended the intervention session; roughly half (n=21) had previously participated in a full scale drill. There was an 11% improvement in fund of knowledge between the pre- and post-test scores (p=0.002). Overall, the tabletop exercise was well received by those with and without prior training, with no significant differences found between these two groups in terms of relevance and appropriateness of content. However, the separate components of the tabletop exercise were variably effective, as gauged by written text comments on the questionnaire. ^ Conclusions. Tabletop exercises can be a useful training modality in disaster preparedness, as evidenced by improvement in knowledge and qualitative feedback on its value. Future offerings could incorporate recordings of participant responses during the drill, so that better feedback can be provided to them. Additional research should be conducted, using the same or similar design, in different populations that are stakeholders in disaster preparedness, so that the generalizability of these findings can be determined.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the tragic events of September, 11 2001 the United States bioterrorism and disaster preparedness has made significant progress; yet, numerous research studies of nationwide hospital emergency response have found alarming shortcomings in surge capacity and training level of health care personnel in responding to bioterrorism incidents. The primary goals of this research were to assess hospital preparedness towards the threat of bioterrorist agents in the Southwest Region of the United States and provide recommendations for its improvement. Since little formal research has been published on the hospital preparedness of Oklahoma, Arizona, Texas and New Mexico, this research study specifically focused on the measurable factors affecting the respective states' resources and level of preparedness, such as funding, surge capacity and preparedness certification status.^ Over 300 citations of peer-reviewed articles and 17 Web sites were reviewed, of which 57 reports met inclusion criteria. The results of the systematic review highlighted key gaps in the existing literature and the key targets for future research, as well as identified strengths and weaknesses of the hospital preparedness in the Southwest states compared to the national average. ^ Based on the conducted research, currently, the Southwest states hospital systems are unable fully meet presidential preparedness mandates for emergency and disaster care: the staffed beds to 1,000 population value fluctuated around 1,5 across the states; funding for the hospital preparedness lags behind hospital costs by millions of dollars; and public health-hospital partnership in bioterrorism preparedness is quite weak as evident in lack of joint exercises and training. However, significant steps towards it are being made, including on-going hospital preparedness certification by the Joint Commission of Health Organization. Variations in preparedness levels among states signify that geographic location might determine a hospital level of bioterrorism preparedness as well, tending to favor bigger states such as Texas.^ Suggested recommendations on improvement of the hospital bioterrorism preparedness are consistent with the existing literature and include establishment and maintenance of solid partnerships between hospitals and public health agencies, conduction of joint exercises and drills for the health care personnel and key partners, improved state and federal funding specific to bioterrorism preparedness objectives, as well as on-going training of the clinical personnel on recognition of the bioterrorism agents.^

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We report on the EPICA Dronning Maud Land (East Antarctica) deep drilling operation. Starting with the scientific questions that led to the outline of the EPICA project, we introduce the setting of sister drillings at NorthGRIP and EPICA Dome C within the European ice-coring community. The progress of the drilling operation is described within the context of three parallel, deep-drilling operations, the problems that occurred and the solutions we developed. Modified procedures are described, such as the monitoring of penetration rate via cable weight rather than motor torque, and modifications to the system (e.g. closing the openings at the lower end of the outer barrel to reduce the risk of immersing the drill in highly concentrated chip suspension). Parameters of the drilling (e.g. core-break force, cutter pitch, chips balance, liquid level, core production rate and piece number) are discussed. We also review the operational mode, particularly in the context of achieved core length and piece length, which have to be optimized for drilling efficiency and core quality respectively. We conclude with recommendations addressing the design of the chip-collection openings and strictly limiting the cable-load drop with respect to the load at the start of the run.