993 resultados para Distributed vertical loads


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents the impact of different types of load models in distribution network with distributed wind generation. The analysis is carried out for a test distribution system representative of the Kumamoto area in Japan. Firstly, this paper provides static analysis showing the impact of static load on distribution system. Then, it investigates the effects of static as well as composite load based on the load composition of IEEE task force report [1] through an accurate time-domain analysis. The analysis shows that modeling of loads has a significant impact on the voltage dynamics of the distribution system with distributed generation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper investigates the oscillatory behavior of power distribution systems in the presence of distributed generation. The analysis is carried out over a distribution test system with two doubly fed induction type wind generators and different types of induction motor loads. The system is linearized by the perturbation method. Eigenvalues are calculated to see the modal interaction within the system. The study indicates that interactions between closely placed converter controllers and induction motor loads significantly influence the damping of the oscillatory modes of the system. The critical modes have a frequency of oscillation between the electromechanical and subsynchronous oscillations of power systems. Time-domain simulations are carried out to verify the validity of the modal analysis and to provide a physical feel for the types of oscillations that occur in distribution systems. Finally, significant parameters of the system that affect the damping and frequency of the oscillation are identified.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A parallel technique, for a distributed memory machine, based on domain decomposition for solving the Navier-Stokes equations in cartesian and cylindrical coordinates in two dimensions with free surfaces is described. It is based on the code by Tome and McKee (J. Comp. Phys. 110 (1994) 171-186) and Tome (Ph.D. Thesis, University of Strathclyde, Glasgow, 1993) which in turn is based on the SMAC method by Amsden and Harlow (Report LA-4370, Los Alamos Scientific Laboratory, 1971), which solves the Navier-Stokes equations in three steps: the momentum and Poisson equations and particle movement, These equations are discretized by explicit and 5-point finite differences. The parallelization is performed by splitting the computation domain into vertical panels and assigning each of these panels to a processor. All the computation can then be performed using nearest neighbour communication. Test runs comparing the performance of the parallel with the serial code, and a discussion of the load balancing question are presented. PVM is used for communication between processes. (C) 1999 Elsevier B.V. B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last decade, distributed generation, with its various technologies, has increased its presence in the energy mix presenting distribution networks with challenges in terms of evaluating the technical impacts that require a wide range of network operational effects to be qualified and quantified. The inherent time-varying behavior of demand and distributed generation (particularly when renewable sources are used), need to be taken into account since considering critical scenarios of loading and generation may mask the impacts. One means of dealing with such complexity is through the use of indices that indicate the benefit or otherwise of connections at a given location and for a given horizon. This paper presents a multiobjective performance index for distribution networks with time-varying distributed generation which consider a number of technical issues. The approach has been applied to a medium voltage distribution network considering hourly demand and wind speeds. Results show that this proposal has a better response to the natural behavior of loads and generation than solely considering a single operation scenario.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The knowledge of interaction between infective larvae setting and the type of grass is important to epidemiological studies and the control of gastrointestinal nematodes in sheep. The objective of this work was to evaluate the effects of three species of forage grasses on pasture characteristics and the vertical distribution of infective larvae (L3) of gastrointestinal nematodes of woolless sheep on the grasses during the rainy season. Sixty non-periparturients ewes were used, naturally infected, equally distributed on 2ha paddocks sowed with Tanzania, star, and gamba grasses, managed under continuous grazing system, from October 2003 to March 2004, at Santa Bárbara farm, Barreiras-Bahia-Brazil. Data of three samples between December 2003 and March 2004 were analyzed by SAS, using split-plot design, with 10 replications. Infective larvae of Haemonchus spp. and Trichostrongylus spp. were observed on forage in all stratus of vertical layer of the grasses without a defined pattern. Pastures with different characteristics under continuous grazing system had good conditions for developing infective larvae of sheep.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Odontologia - FOA

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Usually, ancillary services are provided by large conventional generators; however, with the growing interest in distributed generation to satisfy energy and environmental requirements, it seems reasonable to assume that these services could also be provided by distributed generators in an economical and efficient way. In this paper, a proposal for enhancement of the capacity of active power reserve for frequency control using distributed generators is presented. The goal is to minimize the payments done by the transmission system operator to conventional and distributed generators for this ancillary service and for the energy needed to satisfy loads and system losses, subject to a set of constraints. In order to perform analysis, the proposal was implemented using data of the IEEE 30-bus transmission test system. Comparisons were performed considering conventional generators without and with distributed generators installed in the system.