991 resultados para Diluted nitric acid


Relevância:

80.00% 80.00%

Publicador:

Resumo:

An activated carbon was obtained by chemical activation with phosphoric acid, CM, from a mineral carbon. Afterwards, the carbon was modified with 2 and 5 molL-1, CMox2 and CMox5 nitric acid solutions to increase the surface acid group contents. Immersion enthalpy at pH 4 values and Pb2+ adsorption isotherms were determined by immersing activated carbons in aqueous solution. The surface area values of the adsorbents and total pore volume were approximately 560 m².g-1 and 0.36 cm³g-1, respectively. As regards chemical characteristics, activated carbons had higher acid sites content, 0.92-2.42 meq g-1, than basic sites, 0.63-0.12 meq g-1. pH values were between 7.4 and 4.5 at the point of zero charge, pH PZC. The adsorbed quantity of Pb2+ and the immersion enthalpy in solution of different pH values for CM activated carbon showed that the values are the highest for pH 4, 15.7 mgg-1 and 27.6 Jg-1 respectively. Pb2+ adsorption isotherms and immersion enthalpy were determined for modified activated carbons and the highest values were obtained for the activated carbon that showed the highest content of total acid sites on the surface.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Taloudellisesti tärkeiden metallien varannot ja tuotanto eivät ole jakautuneet tasaisesti. Maantieteelliset alueet, joilla ei ole omia varantoja ovat riippuvaisia muualta tuoduista raaka-aineista. Euroopan komissio ja USA:n energiaministeriö ovat luokitelleet tietyt metallit kriittisiksi niiden taloudellisen merkittävyyden ja saatavuuteen liittyvien epävarmuustekijöiden johdosta. Tällaisten metallien saatavuutta voitaisiin mahdollisesti parantaa lisäämällä niiden talteenottoa jätteistä. Tutkimuksessa kartoitettiin Euroopan komission kriittiseksi luokittelemien metallien pitoisuuksia eräissä jätevirroissa. Kartoitetut jätteet olivat teollisissa poltto-prosesseissa syntyneitä polttojätteitä, prosessiteollisuuden jätesakkoja ja sähkö- ja elektroniikkajätteitä. Kartoituksen perusteella valittiin lupaavimmat jätteet ja suoritettiin niille talteenottokokeita. Talteenottokokeita suoritettiin kolmelle jätteelle. Yhdestä jätesakasta liuotettiin indiumia rikki- ja suolahapoilla. Kahden eri polttojätteen seoksesta liuotettiin galliumia rikkihapolla. Käytettyjen loisteputkien käsittelyprosessista peräisin olleesta sakasta liuotettiin maametalleja rikki- ja suolahapoilla sekä rikki- ja typpihapon seoksella. Indium liukeni heikosti (korkeintaan 25 %) huoneenlämmössä rikkihapolla. Suolahapolla se liukeni paremmin (68 %). Polttojätteen liuotuskokeissa galliumin talteenottoasteen todettiin riippuvan käytetyn liuottimen määrästä. Loisteputkijätesakasta liukeni yttriumia ja europiumia kaikilla käytetyillä happoliuoksilla noin 70–100 %. Käytetyillä happokonsentraatioilla ei havaittu suuria eroja yttriumin ja europiumin liukoisuuksissa. Näitä metalleja voitaisiin mahdollisesti ottaa talteen tämän tyyppisestä sakasta liuottamalla ne happoliuoksella ja saostamalla oksalaattina. Tarvittaessa liuokset voitaisiin puhdistaa tai metallit erottaa toisistaan neste–nesteuutolla, joka on tärkein maametallien tuotantoon käytetty hydrometallurginen menetelmä.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Abstract: The concentration of heavy metals (Cr, Fe, Al, As, Cd, Cu, Pb, Mo, Ni, Se and Zn) was evaluated in the blood of nestling blue macaws (Anodorhynchus hyacinthinus) captured in the Pantanal, Mato Grosso do Sul (n=26) in 2012; this was based on the hypothesis that these birds exhibit levels of these heavy metals in their organism and that these interfere in hatching success, weight and age of the chicks. Blood samples were digested with nitric acid and hydrochloric acid and the quantification of metals was performed by ICP-OES (Optical Emission Spectroscopy and Inductively Coupled Plasma). Blood samples of nestlings showed concentrations of Cr (0.10μg/g) Fe (3.06μg/g) Al (3.46μg/g), Cd (0.25μg/g) Cu (0.74μg/g), Mo (0.33μg/g), Ni (0.61μg/g), Se (0.98μg/g), and Zn (2.08μg/g). The levels of heavy metals found were not associated with weight, age and hatching success of the chicks.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Extensive studies have been initiated to generate enough data to register the methyl homologue (MBC-MIC, see List of Abbreviations, page 14) of benomyl (MBC-BIC) as a commercial product through a joint effort between the federal government and Canadian industry. The objective of this study, as part of the whole project, was to generate fundamental data on the physical properties of the series of benomyl homologues (MBC-MIC, MBC-EIC, MBC-PIC and MBC-BIC). These data include the half lives of these compounds in water at the pH range from 2 to 12; they ranged from 0.7 to 10. 1 hours. Standard solutions of these compounds in concentrated acid were found to be stable for at least two weeks, and in the case of MBC-MIC it was stable at least 1 month. Another major goal of this study was to determine the solubility of each compound in water at different pHs in the range of 1 to 12. The solubility of the compounds ranged from 0.6 jig/mL to 396 fig/mL. In addition, it was possible to prepare stable stock solutions at concentrations > 1 000 |ig/mL in concentrated nitric acid. Several aspects of analytical methods have been improved to accurately assess the solubility and rate of degradation of benomyl and its homologues in alkaline conditions. The determination of melting points was attempted but all compounds decomposed before melting.To complement the studies of the benomyl homologue series attempts were made to explore the presence of any relationships between the structures of the compounds and their properties. Although there were some exceptions, the compound's solubility decreased and half life increased as the molecular size increased from the methyl to the butyl analogue.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Analytical methods for the determination of trace amounts of germanium, tin and arsenic were established using hydride generation coupled with direct current plasma atomic emission spectrometry. A continuous gas flowing batch system for the hydride generation was investigated and was applied to the determination of germanium(Ge), tin(Sn), antimony(Sb) and lead(Pb) (Preliminary results suggest that it is also applicable to arsenic)As) ). With this system, the reproducibility of signals was improved and the determination was speeded up, compared with the conventional batch type hydride generation system. Each determination was complete within one minute. Interferences from a number of transition metal ions, especially from Pd(II), Pt(IV), Ni(II), Cu(II), Co(II), and Fe(II, III), have proven to be very serious under normal conditions, in the determination of germanium, tin, and arsenic. These interference effects were eliminated or significantly reduced in the presence of L-cystine or L-cysteine. Thus, a 10-1000 fold excess of Ni(II), Cu(II), Co(II), Fe(II), Pt(IV), Pd(II), etc. can be tolerated without interference, In the presence of L-cystine or L-cysteine, compared with absence of interference reducing agent. The methods for the determination of Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of standard reference materials gave excellent results of As and Sn contents in agreement with the certified values, showing there was no systematic interference. The detection limits for both germanium and tin were 20 pg ml- I . Preliminary studies were carried out for the determination of antimony and lead. Antimony was found to react with NaBH4, remaInIng from the previous determinations, giving an analytical signal. A reversed injection manner, i.e., injection of the NaBH4 solution prior to the analyte solution was used to avoid uncertainty caused by residual NaBH4 present and to ensure that an excess of NaB H4 was available. A solution of 0.4% L-cysteine was found to reduce the interference from selected transition metal ions, Co(II), Cu(II), Ni(II) and Pt(IV). Hydrochloric acid - hydrogen peroxide, nitric acid - ammonium persulphate, and potassium dichromate malic acid reaction systems for lead hydride generation were compared. The potassium dichromate - malic acid reaction medium proved to be the best with respect to reproducibility and minimal interference. Cu(II), Ni(II), and Fe(II) caused strong interference In lead determinations, which was not reduced by L-cysteine or Lcystine. Sodium citrate, ascorbic acid, dithizone, thiosemicarbazide and penicillamine reduced interferences to some extent. Further interference reduction studies were carried out uSIng a number of amino acids, glycine, alanine, valine, leucine and histidine, as possible interference reducing agents in the determination of germanium. From glycine, alanine, valine to leucine, the interference reduction effect in germanium determinations decreased. Histidine II was found to be very promising In the reduction of interference. In fact, histidine proved more efficient than L-cystine and L-cysteine In the reduction of interference from Ni(II) in the determination of germanium. Signal enhancement by easily ionized elements (EIEs), usually regarded as an interference effect in analysis by DCP-AES, was studied and successfully applied to advantage in improving the sensitivity and detection limit in the determination of As, Ge, Sn, Sb, and Pb. The effect of alkali and alkaline-earth elements on the determination of the above five hydride forming elements was studied. With the appropriate EIE, a signal enhancement of 40-115% was achieved. Linear calibration and good reproducibility were also obtained in the presence of EIEs. III

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The thesis entitled “Synergistic solvent extraction of Thorium(IV) and Uranium(VI) with β-diketones in presence of oxo-donors” embodies the results of the investigations carried out on the extraction of thorium(IV) an uranium(VI) with heterocyclic β-diketones in the presence and absence of various macrocyclic ligands and neutral organophosphorus extractants. The objective of this work is to generate the knowledge base to achieve better selectivity between thorium(IV) and uranium(VI) by understanding the interactions of crown ethers or neutral organophosphorus extractants with metal-heterocyclic β-diketonate complexes. Para-substituted 1-phenyl-3-methyl-4-aroyl-5-pyrazolones, namely,1-phenyl-3-methyl-4-(4-fluorobenzoyl)-5-pyrazolone (HPMFBP) and 1-phenyl-3-methyl-4-(4-toluoyl)-5-pyrazolone (HPMTP) were synthesized and characterized by elemental analysis, IR and H NMR spectral data. The synthesized ligands have been utilized for the extraction of thorium(IV) and uranium(VI) from nitric acid solutions in the presence and absence of various crown ethers. Thorium(IV) and uranium(VI) complexes with HPMPP(1-Phenyl-3-methyl-4-pivaloyl-5-pyrazolone) and neutral organophosphorus extractants were synthesized and characterized by IR and P NMR spectral data to further understand the interactions of neutral organophosphorus extractants with metal-chelates. Solid complexes of thorium(IV) and uranium(VI) with para-substituted 4-aroyl-5-isoxazolones and crown ethers were isolated and characterized by various spectroscopic techniques to further clarify the nature of the extracted complexes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Titania, sulfated titania and chromium loaded sulfated titania were prepared by sol–gel method and characterized using different technique. Phenol is nitrated regioselectively by nitric acid using chromium loaded sulfated titania catalysts. A remarkable ortho selectivity is observed in solid state nitration to yield exclusively ortho-nitrophenol. Compared to the conventional process, phenol nitration over solid acid catalyst is a clean and environment friendly process. Catalytic activity well correlates with the Brönsted acid sites of these catalysts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A análise histopatológica de tecido ósseo exige uma etapa de descalcificação. O método usual consiste na imersão das amostras em ácidos, mas para além de provocarem danos tecidulares, o processo é prolongado. A utilização de micro-ondas acelera a descalcificação, mas não deve comprometer a imagem microscópica. Objetivo: Diminuir a duração da descalcificação, mantendo a qualidade da imagem microscópica. Metodologia: Foram testadas amostras de osso compacto e esponjoso. Realizou-se a descalcificação pelo método convencional e pelo método em micro-ondas, através da adaptação de um protocolo conhecido. Utilizou-se ácido nítrico a 5% e 10%. Resultados: Nos fragmentos de maiores dimensões, após 4 horas com ácido nítrico a 10% em micro-ondas, não se conseguiu uma descalcificação completa, apesar da imagem histológica ser razoável. Nos fragmentos de osso esponjoso, verificou-se uma redução de cerca de 25 horas relativamente ao método convencional. Nas biópsias, houve uma redução de aproximadamente 10 horas, utilizando ácido nítrico a 5%. Com ácido nítrico a 10% houve destruição tecidular. Nos casos em que se obteve uma descalcificação completa, a imagem microscópica apresenta fraca qualidade. Conclusão: A utilização de micro-ondas com ácido nítrico a 5%/10%, aplicando o protocolo deste estudo, reduz a duração da descalcificação, mas compromete a imagem microscópica.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The photochemical evolution of an anthropogenic plume from the New-York/Boston region during its transport at low altitudes over the North Atlantic to the European west coast has been studied using a Lagrangian framework. This plume, originally strongly polluted, was sampled by research aircraft just off the North American east coast on 3 successive days, and 3 days downwind off the west coast of Ireland where another aircraft re-sampled a weakly polluted plume. Changes in trace gas concentrations during transport were reproduced using a photochemical trajectory model including deposition and mixing effects. Chemical and wet deposition processing dominated the evolution of all pollutants in the plume. The mean net O3 production was evaluated to be -5 ppbv/day leading to low values of O3 by the time the plume reached Europe. Wet deposition of nitric acid was responsible for an 80% reduction in this O3 production. If the plume had not encountered precipitation, it would have reached the Europe with O3 levels up to 80-90 ppbv, and CO levels between 120 and 140 ppbv. Photochemical destruction also played a more important role than mixing in the evolution of plume CO due to high levels of both O3 and water vapour showing that CO cannot always be used as a tracer for polluted air masses, especially for plumes transported at low altitudes. The results also show that, in this case, an important increase in the O3/CO slope can be attributed to chemical destruction of CO and not to photochemical O3 production as is often assumed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

New tri-functional ligands of the type R2NCCCH2SCH2CCNR2 (where R = iso-propyl, n-butyl or iso-butyl) were prepared and characterized. The coordination chemistry of these ligands with uranyl and lanthanum(III) nitrates was studied by using the IR, (HNMR)-H-1 and elemental analysis methods. Structures for the compounds [UO2(NO3)(2)((Pr2NCOCH2SCH2CONPr2)-Pr-i-Pr-i)] [UO2(NO3)(2)((Bu2NCOCH2SCH2CONBu2)-Bu-i-Bu-i)(2)] [La(NO3)(3)((Pr2NCOCH2SCH2CONPr2)-Pr-i-Pr-i)(2)] and [La(NO3)(3)((Bu2NCOCH2SCH2CONBu2)-Bu-i-Bu-i)(2)] were determined by single crystal X-ray diffraction. These structures show that the ligand acts as a bidentate chelating ligand and bonds through both the carbamoyl groups to the uranyl and lanthanum(III) nitrate groups. Solvent extraction studies show that the ligand can extract the uranyl ion from the nitric acid medium but does not show any ability to extract the americium (III) ion. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

New hydrophobic, tetradentate nitrogen heterocyclic reagents, 6.6'-bis-(5,6-dialkyl- 1,2,4-triazin-3-yl)2,2'-bipyridines (BTBPs) have been synthesised. These reagents form complexes with lanthanides and crystal structures with 11 different lanthanides have been determined. The majority of the structures show the lanthanide to be 10-coordinate with stoichiometry [Ln(BTBP)(NO3)(3)] although Yb and Lu are 9-coordinate in complexes with stoichiometry [Ln(BTBP)(NO3)(2)(H2O)](NO3). In these complexes the BTBP ligands are tetradentate and planar with donor nitrogens mutually cis i.e. in the cis, cis, cis conformation. Crystal structures of two free molecules, namely C2-BTBP and CyMe4-BTBP have also been determined and show different conformations described as cis, trans, cis and trans, trans, trans respectively. A NMR titration between lanthanum nitrate and C5-BTBP showed that two different complexes are to be found in solution, namely [La(C5-BTBP)(2)](3+) and [La(C5-BTBP)(NO3)(3)]. The BTBPs dissolved in octanol were able to extract Am(III) and Eu(III) from 1 M nitric acid with large separation factors.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The tetradentate ligand (C-5-BTBP) was able to extract americium(III) selectively from nitric acid. In octanol/kerosene the distribution ratios suggest that stripping will be possible. C-5-BTBP has unusual properties and potentially offers a means of separating metals, which otherwise are difficult to separate. For example C-5-BTBP has the potential to separate paliadium(II) from a mixture containing rhodium(III) and ruthenium(H) nitrosyl. In addition, C-5-BTBP has the potential to remove traces of cadmium from effluent or from solutions of other metals contaminated with cadmium. C-5-BTBP has potential as a reagent for the separation of americium(III) from solutions contaminated with iron(III) and nickel(II), hence offering a means of concentrating americium(III) for analytical purposes from nitric acid solutions containing high concentrations of iron(III) or nickel(II).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The extraction of americium(III), curium(III), and the lanthanides(III) from nitric acid by 6,6'- bis (5,5,8,8-tetramethyl-5,6,7,8-tetrahydro-benzo[1,2,4]triazin-3-yl)-[2,2'] bipyridine (CyMe4-BTBP) has been studied. Since the extraction kinetics were slow, N,N'-dimethyl-N,N'-dioctyl-2-(2-hexyloxy-ethyl)malonamide (DMDOHEMA) was added as a phase transfer reagent. With a mixture of 0.01 M CyMe4-BTBP + 0.25 M DMDOHEMA in n -octanol, extraction equilibrium was reached within 5 min of mixing. At a nitric acid concentration of 1 M, an americium(III) distribution ratio of approx. 10 was achieved. Americium(III)/lanthanide(III) separation factors between 50 (dysprosium) and 1500 (lanthanum) were obtained. Whereas americium(III) and curium(III) were extracted as disolvates, the stoichiometries of the lanthanide(III) complexes were not identified unambiguously, owing to the presence of DMDOHEMA. In the absence of DMDOHEMA, both americium(III) and europium(III) were extracted as disolvates. Back-extraction with 0.1 M nitric acid was thermodynamically possible but rather slow. Using a buffered glycolate solution of pH=4, an americium(III) distribution ratio of 0.01 was obtained within 5 min of mixing. There was no evidence of degradation of the extractant, for example, the extraction performance of CyMe4-BTBP during hydrolylsis with 1 M nitric acid did not change over a two month contact.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A future goal in nuclear fuel reprocessing is the conversion or transmutation of the long-lived radioisotopes of minor actinides, such as americium, into short-lived isotopes by irradiation with neutrons. In order to achieve this transmutation, it is necessary to separate the minor actinides(III), [An(Ill)], from the lanthanides(III), [Ln(Ill)], by solvent extraction (partitioning), because the lanthanides absorb neutrons too effectively and hence limit neutron capture by the transmutable actinides. Partitioning using ligands containing only carbon, hydrogen, nitrogen and oxygen atoms is desirable because they are completely incinerable and thus the final volume of waste is minimised [1]. Nitric acid media will be used in the extraction experiments because it is envisaged that the An(III)/Ln(III) separation process could take place after the PUREX process. There is no doubt that the correct design of a molecule that is capable of acting as a ligand or extraction reagent is required for the effective separation of metal ions such as actinides(III) from lanthanides. Recent attention has been directed towards heterocyclic ligands with for the preferential separation of the minor actinides. Although such molecules have a rich chemistry, this is only now becoming sufficiently well understood in relation to the partitioning process [2]. The molecules shown in Figures I and 2 will be the principal focus of this study. Although the examples chosen here are used rather specific, the guidelines can be extended to other areas such as the separation of precious metals [3].