926 resultados para Device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The “third-generation” 3D graphene structures, T-junction graphene micro-wells (T-GMWs) are produced on cheap polycrystalline Cu foils in a single-step, low-temperature (270 °C), energy-efficient, and environment-friendly dry plasma-enabled process. T-GMWs comprise vertical graphene (VG) petal-like sheets that seemlessly integrate with each other and the underlying horizontal graphene sheets by forming T-junctions. The microwells have the pico-to-femto-liter storage capacity and precipitate compartmentalized PBS crystals. The T-GMW films are transferred from the Cu substrates, without damage to the both, in de-ionized or tap water, at room temperature, and without commonly used sacrificial materials or hazardous chemicals. The Cu substrates are then re-used to produce similar-quality T-GMWs after a simple plasma conditioning. The isolated T-GMW films are transferred to diverse substrates and devices and show remarkable recovery of their electrical, optical, and hazardous NO2 gas sensing properties upon repeated bending (down to 1 mm radius) and release of flexible trasparent display plastic substrates. The plasma-enabled mechanism of T-GMW isolation in water is proposed and supported by the Cu plasma surface modification analysis. Our GMWs are suitable for various optoelectronic, sesning, energy, and biomedical applications while the growth approach is potentially scalable for future pilot-scale industrial production.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reducing unwanted trawl bycatch is actively encouraged in Australia, particularly in prawn trawl fisheries. We tested the performance of a Bycatch Reduction Device, the Yarrow Fisheye, during two periods of commercial fishing operations in Australia's Northern Prawn Fishery, by comparing the catches of paired treatment and control nets. We compared the catch weights of the small fish and invertebrate bycatch, and the commercially important tiger prawns, from 42 trawls in 2002. The Yarrow Fisheye reduced the weight of small bycatch by a mean of 22.7%, with no loss of tiger prawn. We also compared the numbers of seasnakes caught in 41 and 72 trawls during the spring trawling seasons of 2004 and 2005, respectively. The Yarrow Fisheye reduced the catches by a mean of 43.3%. Flume-tank tests of the Yarrow Fisheye showed that this device created a slow water-flow region extending over 2 m downstream from its position in the net, and close to where the catch accumulates. Finfish and seasnakes may be exploiting this slow water-flow region to escape via the eye, Although the reductions in fish and seasnake bycatch were excellent, we think they could be further improved by relating differences in fisheye position and localised water displacements, to design and rigging changes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental results pertaining to the initiation, dynamics and mechanism of cavitation erosion on poly(methyl methacrylate) specimens tested in a rotating disk device are described in detail. Erosion normally starts at the location nearest to the center of rotation (CR). As the exposure time to cavitation increases, additional erosion areas or sites appear away from the CR and secondary erosion (induced by eroded pits) spreads upstream and merges with the main pit. The microcracks increase in density towards the end of the incubation period and transform into macrocracks in most cases. A study of light optical photographs and scanning electron micrographs of the eroded area shows that material particles are removed from the network of cracks because of crack joining and pits indicate particle debris. Optical degradation (loss of transmittance) is observed to be greater on the back of the specimen than on the front.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We discuss micro ring resonator based optical logic gates using Kerr-type nonlinearity. Resonant wavelength selectivity is one key factor in achieving the desired gate. Based on basic gates like AND gate, OR gate etc. We proceed to propose a 3-bit binary adder circuit.Due to the presence of more than a single wavelength, the system gets complicated as we increase the number of components in the circuit. Hence it has been observed that for efficient designing and functioning of digital circuits in optical domain, we need a device which can give single wavelength output, filtering out all other wavelengths and at the same time preserve the digital characteristics of the output. We propose such filter-preserver device based on micro ring resonator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of head-mounted displays (HMDs) can produce both positive and negative experiences. In an effort increase positive experiences and avoid negative ones, researchers have identified a number of variables that may cause sickness and eyestrain, although the exact nature of the relationship to HMDs may vary, depending on the tasks and the environments. Other non-sickness-related aspects of HMDs, such as users opinions and future decisions associated with task enjoyment and interest, have attracted little attention in the research community. In this thesis, user experiences associated with the use of monocular and bi-ocular HMDs were studied. These include eyestrain and sickness caused by current HMDs, the advantages and disadvantages of adjustable HMDs, HMDs as accessories for small multimedia devices, and the impact of individual characteristics and evaluated experiences on reported outcomes and opinions. The results indicate that today s commercial HMDs do not induce serious sickness or eyestrain. Reported adverse symptoms have some influence on HMD-related opinions, but the nature of the impact depends on the tasks and the devices used. As an accessory to handheld devices and as a personal viewing device, HMDs may increase use duration and enable users to perform tasks not suitable for small screens. Well-designed and functional, adjustable HMDs, especially monocular HMDs, increase viewing comfort and usability, which in turn may have a positive effect on product-related satisfaction. The role of individual characteristics in understanding HMD-related experiences has not changed significantly. Explaining other HMD-related experiences, especially forward-looking interests, also requires understanding more stable individual traits and motivations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The short duration of the Doppler signal and noise content in it necessitate a validation scheme to be incorporated in the electronic processor used for frequency measurement, There are several different validation schemes that can be employed in period timing devices. A detailed study of the influence of these validation schemes on the measured frequency has been reported here. These studies were carried out by using a combination of a fast A/D converter and computer. Doppler bursts obtained from an air flow were digitised and stored on magnetic discs. Suitable computer programs were then used to simulate the performance of period timing devices with different validation schemes and the frequency of the stored bursts were evaluated. It is found that best results are obtained when the validation scheme enables frequency measurement to be made over a large number of cycles within the burst.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ms Breathless is a 59-year-old lady living with chronic obstructive pulmonary disease (COPD) for several years now, and quit smoking over 20 years ago. She sometimes experiences symptoms of breathlessness, and an unrelenting productive cough, particularly when she comes in contact with dusty places, second-hand smoke, or when her allergies and hay fever play up. Apart from these triggers, her symptoms are well maintained with her inhalers glycopyrronium bromide (Seebri) and indacaterol (Onbrez), and she has been using them for about nine months. Ms Breathless is otherwise healthy, and not taking any other medicines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forage budgeting, land condition monitoring and maintaining ground cover residuals are critical management practices for the long term sustainability of the northern grazing industry. The aim of this project is to do a preliminary investigation into industry need, feasibility and willingness to adopt a simple to use hand-held hardware device and compatible, integrated software applications that can be used in the paddock by producers, to assist in land condition monitoring and forage budgeting for better Grazing Land Management and to assist with compliance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A period timing device suitable for processing laser Doppler anemometer signals has been described here. The important features of this instrument are: it is inexpensive, simple to operate, and easy to fabricate. When the concentration of scattering particles is low the Doppler signal is in the form of a burst and the Doppler frequency is measured by timing the zero crossings of the signal. But the presence of noise calls for the use of validation criterion, and a 5–8 cycles comparison has been used in this instrument. Validation criterion requires the differential count between the 5 and 8 cycles to be multiplied by predetermined numbers that prescribe the accuracy of measurement. By choosing these numbers to be binary numbers, much simplification in circuit design has been accomplished since this permits the use of shift registers for multiplication. Validation accuracies of 1.6%, 3.2%, 6.3%, and 12.5% are possible with this device. The design presented here is for a 16-bit processor and uses TTL components. By substituting Schottky barrier TTLs the clock frequency can be increased from about 10 to 30 MHz resulting in an extension in the range of the instrument. Review of Scientific Instruments is copyrighted by The American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The existing internet computing resource, Biomolecules Segment Display Device (BSDD), has been updated with several additional useful features. An advanced option is provided to superpose the structural motifs obtained from a search on the Protein Data Bank (PDB) in order to see if the three-dimensional structures adopted by identical or similar sequence motifs are the same. Furthermore, the options to display structural aspects like inter- and intra-molecular interactions, ion-pairs, disulphide bonds, etc. have been provided.The updated resource is interfaced with an up-to-date copy of the public domain PDB as well as 25 and 90% non-redundant protein structures. Further, users can upload the three-dimensional atomic coordinates (PDB format) from the client machine. A free molecular graphics program, JMol, is interfaced with it to display the three-dimensional structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of material properties of an environmentally friendly, optically transparent dielectric material, polyterpenol, on the carrier transients within the pentacene-based double-layer MTM device was investigated. Polyterpenol films were RF plasma polymerised under varied process conditions, with resultant films differing in surface chemistry and morphology. Independent of type of polyterpenol, time-resolved EFISHG study of IZO/polyterpenol/pentacene/Au structures showed similar transient behaviour with carriers injected into pentacene from Au electrode only, confirming polyterpenol to be a suitable blocking layer for visualisation of single-species carrier transportation during charging and discharging under different bias conditions. Polyterpenol fabricated under higher input power show better promise due to higher chemical and thermal stability, improved uniformity, and absence of defects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-resolved electric field induced second harmonic generation technique was used to probe the carrier transients within double-layer pentacene-based MIM devices. Polyterpenol thin films fabricated from non-synthetic environmentally sustainable source were used as a blocking layer to assist in visualisation of single-species carrier transportation during charging and discharging under different bias conditions. Results demonstrated that carrier transients were comprised of charging on electrodes, followed by carrier injection and charging of the interface. Polyterpenol was demonstrated to be a sound blocking material and can therefore be effectively used for probing of double-layer devices using EFISHG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we propose an extension to the I/O device architecture, as recommended in the PCI-SIG IOV specification, for virtualizing network I/O devices. The aim is to enable fine-grained controls to a virtual machine on the I/O path of a shared device. The architecture allows native access of I/O devices to virtual machines and provides device level QoS hooks for controlling VM specific device usage. For evaluating the architecture we use layered queuing network (LQN) models. We implement the architecture and evaluate it using simulation techniques, on the LQN model, to demonstrate the benefits. With the architecture, the benefit for network I/O is 60% more than what can be expected on the existing architecture. Also, the proposed architecture improves scalability in terms of the number of virtual machines intending to share the I/O device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The evolutionary function of X chromosome inactivation is thought to be dosage compensation. However, there is, at present, little evidence to suggest that most X chromosome-linked genes require such compensation. Another view--that X chromosome inactivation may be related to sex determination--is examined here. Consider a hypothetical DNA sequence regulating a major structural gene concerned with the determination of maleness. If this regulatory sequence occurs in both X and Y chromosomes and if its copy number in the Y chromosome is significantly greater than in the X chromosome, then the male-determining properties of the Y chromosome could be attributed to this higher copy number. On the other hand, if the Y chromosome has the same copy number of this sequence as the X chromosome, it is difficult to see how determination of two sexes would occur under such circumstances because XX and XY genomes would then be indistinguishable in this regard. Such a situation seems to occur in the human species with respect to the banded krait minor satellite, a repetitious DNA sequence associated with sex determination. This apparent difficulty may be resolved if X chromosome inactivation renders regulatory as well as structural genes nonfunctional and thereby brings about a significant reduction in the effective copy number of X chromosome-linked DNA sequences concerned with sex determination. It is suggested that X chromosome inactivation brings about, in this manner, a critical inequality between XX and XY embryos and that sex determination in humans is a consequence of this inequality. An analogous situation appears to exist in certain insects in which inactivation of a haploid set of chromosomes (and presumably, therefore, a 50% reduction in the effective copy number of most genes) is associated with maleness. If this line of reasoning is correct, it would suggest that sex determination may be the primary function of X chromosome inactivation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A period timing device suitable for processing laser Doppler anemometer signals has been described here. The important features of this instrument are: it is inexpensive, simple to operate, and easy to fabricate. When the concentration of scattering particles is low the Doppler signal is in the form of a burst and the Doppler frequency is measured by timing the zero crossings of the signal. But the presence of noise calls for the use of validation criterion, and a 5–8 cycles comparison has been used in this instrument. Validation criterion requires the differential count between the 5 and 8 cycles to be multiplied by predetermined numbers that prescribe the accuracy of measurement. By choosing these numbers to be binary numbers, much simplification in circuit design has been accomplished since this permits the use of shift registers for multiplication. Validation accuracies of 1.6%, 3.2%, 6.3%, and 12.5% are possible with this device. The design presented here is for a 16-bit processor and uses TTL components. By substituting Schottky barrier TTLs the clock frequency can be increased from about 10 to 30 MHz resulting in an extension in the range of the instrument. Review of Scientific Instruments is copyrighted by The American Institute of Physics.