980 resultados para Denture, Partial, Removable


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The alveolar ridge shape plays an important role in predicting the demand on the support tooth and alveolar bone in the removable partial denture (RPD) treatment. However, these data are unclear when the RPD is associated with implants. This study evaluated the influence of the alveolar ridge shape on the stress distribution of a free-end saddle RPD partially supported by implant using 2-dimensioanl finite element analysis (FEA). Four mathematical models (M) of a mandibular hemiarch simulating various alveolar ridge shapes (1-distal desceding, 2- concave, 3-horizontal and 4-distal ascending) were built. Tooth 33 was placed as the abutment. Two RPDs, one supported by tooth and fibromucosa (MB) and other one supported by tooth and implant (MC) were simulated. MA was the control (no RPD). The load (50N) were applied simultaneously on each cusp. Appropriate boundary conditions were assigned on the border of alveolar bone. Ansys 10.0 software was used to calculate the stress fields and the von Mises equivalent stress criteria (σvM) was applied to analyze the results. The distal ascending shape showed the highest σvM for cortical and medullar bone. The alveolar ridge shape had little effect on changing the σvM based on the same prosthesis, mainly around the abutment tooth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: Adequate preparation of abutment teeth for removable partial denture (RPD) rest seats allows appropriate masticatory force transmission, retention, and stability of supporting structures. It follows that careful preparation will be important for the longevity of the rehabilitation. The present study aimed to clinically evaluate rest seats and undercut areas of abutment teeth in RPD wearers after 2 years of use. MATERIALS AND METHODS: A total of 193 occlusal, incisal, and cingulum rest seats were evaluated in terms of shape, rest adaptation, wear, caries, fractures, and surface type (enamel, composite resin, or amalgam). Two hundred and fourteen undercut areas were evaluated in terms of surface type (enamel or restoration) and integrity. This study was approved by the Research Ethics Committee of the Federal University of Rio Grande do Norte, resolution 196/1996, protocol number 11/05. RESULTS: Intact preparations accounted for 92.2% of the total. Application of the Pearson test (p= 0.289) found no statistically significant differences among the materials on which the rest seats were prepared. For the undercut areas, 20.7% of those obtained on restorative material were nonintact. In addition, Fisher's exact test showed a statistically significant difference (p= 0.001) in surface type; enamel surfaces were shown to be 14 times more stable than restored surfaces. CONCLUSIONS: The results of this study suggest that rest seats are stable, regardless of the material on which they are prepared. Retentive areas were shown to be more stable when they were located in enamel.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The use of clinical indicators of satisfaction (OHIP) can be applied to evaluate the impact of denture use on patient quality of life, since dental problems and disorders interfere in the normal life of individuals. Aim: This study aimed at evaluating the satisfaction level of patients rehabilitated with removable partial dentures (RPD) after 2 years of use. Methods: An observational study was carried out on 28 patients with a mean age of 45 years, treated with RPD at the Department of Dentistry of the Federal University of Rio Grande do Norte in 2005. Patients signed informed consent and answered the Oral Health Impact Profile (OHIP) questionnaire on three occasions: prior to rehabilitation and at 3 months and 2 years of denture use. Repeated-measures ANOVA was applied for data analysis. Results: A difference was found between data obtained at the moment of fitting and three months after denture use (p<0.001). However, no variation was observed when comparing data from 3 months and 2 years of use (p>0.05). The variables of gender and age did not interfere in the result (p>0.05). Conclusions: The degree of patient satisfaction after RPD installation was significant at the moment of fitting and 3 months after denture use, but no significant difference was found between 3 months and 2 years of denture use.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The dual path of insertion concept for removable partial denture (RPD) design may be used in esthetically demanding situations. When compared to conventional RPDs, the main advantage of this design is the minimal use of clasps. This clinical report describes the treatment of a patient with an anterior maxillary edentulous area using a dual path RPD. The diagnostic cast was surveyed to ensure the adequacy of the undercuts on the mesial surfaces of the anterior abutments, where rigid minor connectors were placed. Inverted V-shaped canine cingulum rest seats were prepared to provide resistance to tooth movement during function. The dual path RPD concept allows excellent esthetic results, minimizes tooth preparation, and reduces the tendency toward plaque accumulation in a Kennedy class IV partially edentulous arch.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objectives: The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School.Methods: The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007.Results: 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps.Conclusion: The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Purpose: The aim of this research was to assess, by means of, the bi-dimensional finite element method, the best implant location in the alveolar edge, through stress distribution and support structure displacement of a distal extension removable partial denture associated with an osseointegrated implant of 10.0 x .75 mm, acting as abutment for the denture base.Methods and Materials: Five models in sagittal cut were used to represent: model A-hemi arch containing natural tooth 33 and the distal alveolar edge; model B-similar to model A, but with a conventional removable partial denture to replace the absent teeth; model C (MC)-similar to the previous one, with an implant in the distal region of the edge under the denture base; model D-similar to MC, with the implant in the central region of the edge; model E-similar to MC, with an implant in the mesial region of the edge. With the aid of the finite element program ANSYS 8.0, the models were loaded with strictly vertical forces of 50 N on each cusp tip. Displacement and von Mises Maps were plotted for visualization of results.Results: The introduction of implant diminished the tendency of intrusion of the removable partial denture in all situations. The maximum stress was observed on implant in all situations. Approximating implant in direction of support teeth was benefit for stress distribution.Conclusion: Model D presented the lowest value for maximum tendency to displacement when compared with those found in the other models; model E demonstrated better relief with regard to demand from the abutment tooth; locating the implant near of the abutment tooth influenced positively the distribution of stresses on the analyzed structures.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Objectives: To correlate the presence and number of Candida spp. in the saliva of wearers of removable partial dentures retained with precision attachments with the proportion of metal/acrylic resin present in the dentures. Methods: Saliva samples from 40 removable partial denture wearers (test) and one paired sample of individuals, non- wearers of any type of removable denture (control) were collected, seeded, and the colony forming units of Candida counted and identified. The metal/acrylic resin proportion of each denture was quantified, using silicone plates pressed over each denture. Results: Candida spp. was found in the saliva of 80% of the individuals in the test group and 65% of the control, with C. albicans being themost prevalent species. The test group presented with the highest number of colony forming units of Candida per ml of saliva, and there wasweak correlation between this number and the metal and resin area of the denture (Pearson's coefficient of correlation). Greater prevalence and a higher number of colony forming units of Candida per ml of saliva occurred in removable partial denture wearers ( p = 0.04) with a weak positive correlation between the metal and resin area and the number of colony forming units of Candida per ml of saliva. However, this correlation was more significant for the area of resin. Correlation between factors associated with the removable partial dentures use and Candida spp. in saliva

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Tooth replacement in the maxillary anterior region is especially difficult when the loss includes significant amounts of the residual ridge and the soft tissue. Several techniques are available, such as dental implants or fixed partial denture, and bone and gingival grafts or gingival prostheses, respectively. This article showed a clinical case of an elderly who was treated with a collarless metal-ceramic fixed partial denture and acrylic removable gingival prosthesis to recover the esthetics in the maxillary anterior region. The association of a metal-ceramic fixed denture and gingival prosthesis was an excellent alternative in cases when surgical procedures are contraindicated. © 2012 Japan Prosthodontic Society.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Despite requiring dental crown preparation and possible root canal treatment, besides the difficulty of clinical and laboratory repairs, and financial burden, the association between fixed (FPD) and removable partial dentures (RPD) by means of attachments is an important alternative for oral rehabilitation, particularly when the use of dental implants and FPDs is limited or not indicated. Among the advantages of attachment-retained RPDs are the improvements in esthetics and biomechanics, as well as correction of the buccal arrangement of anterior teeth in Kennedy Class III partially edentulous arches. This article describes the treatment sequence and technique for the use of attachments in therapy combining FPD/RPD. © 2013 by the American College of Prosthodontists.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Background. Despite being functional and having aesthetic benefits, the acceptance of patients regarding the use of removable partial dentures (RPDs) has been low. In part, this is due to the deleterious effects that causes discomfort to the patient. Success depends not only on the care expended by the patient, including daily care and oral hygiene, but also on common goals set by their professional and clinical staff, aiming beyond aesthetics, to incorporate issues of functionality and the well-being of patients. Methods and results. For rehabilitation treatment with RPDs to reach the desired level of success without damaging the support structure, all the steps (diagnose, cavity preparation, adaptation of the metal structures, functional of distal extension and posterior follow-up) in the rehabilitative treatment should be carefully developed. A literature review was carried out, searching through MEDLINE (PubMed) articles published between 1965 and December 2012 including clinical trials and reviews about the use of RPDs. Conclusions. This study describes factors that lead to failures and complications in oral rehabilitation through the use of RPDs and suggests possible solutions.

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

50.00% 50.00%

Publicador:

Resumo:

Loss of posterior teeth may cause an imbalance in the stomatognathic system. Overlay removable partial dentures (ORPD) are a reversible and relatively inexpensive treatment for patients with severely worn teeth. This paper presents a treatment with ORPD in a 55-year-old male patient who had severe attrition in the maxillary and mandibular teeth, temporomandibular joint pain and reduced vertical dimension of occlusion (VDO). The treatment consisted in the reestablishment of the VDO using Lucia’s jig, fabricating removable partial denture with reconstruction of the worn teeth without preparation. This therapy can be used as an alternative treatment to provide esthetic, function and stable occlusion in patients with severely worn teeth.