970 resultados para Dental Prosthesis, Implant-Supported


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to analyze the main aspects that influence the aesthetics of single immediate implant-supported restorations through a literature review on the MEDLINE database. It was observed that immediate implant-supported restorations present clinical success with aesthetic predictability demonstrated by the literature. Proper patient selection and diagnostic and multidisciplinary planning are essential and should be associated to technical ability of professional and knowledge concerning the biology of peri-implant tissues. It is suggested that provisional restoration should be immediately inserted after implant fixation to guide healing of gingival tissues with a proper emergence profile besides psychologic comfort for a patient due to immediate aesthetic reestablishment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Osteodistraction is a clinical reality available for the resolution of bone deficiencies before dental implant placement or in cases where the existing implants are at the wrong position. The objective of this study is to suggest a new possibility for bone distraction, based on tooth-implant bone distractors, in areas were there is the need for extensive alveolar bone recovery, with installed dental implants. This technique presented good results associated with its simplicity and low cost, making it a viable clinical solution for bone tissue augmentation. Although its use is recent, the suggested technique shows the potential to become used widely in attempts to achieve bone-height augmentation, primarily when dental implants are installed and osteointegrated already. (C) 2008 American Association of Oral and Maxillofacial Surgeons

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The purpose of this study was to compare the accuracy of two working cast fabrication techniques using strain-gauge analysis. Methods: Two working cast fabrication methods were evaluated. Based on a master model, 20 working casts were fabricated by means of an indirect impression technique using polyether after splinting the square transfer copings with acrylic resin. Specimens were assigned to 2 groups (n=10): Group A (GA): type IV dental stone was poured around the abutment analogs in the conventional way; Group B (GB), the dental stone was poured in two stages. Spacers were used over the abutment analogs (rubber tubes) and type IV dental stone was poured around the abutment analogs in the conventional way. After the stone had hardened completely, the spacers were removed and more stone was inserted in the spaces created. Six strain-gauges (Excel Ltd.), positioned in a cast bar, which was dimensionally accurate (perfect fit) to the master model, recorded the microstrains generated by each specimen. Data were analyzed statistically by the variance analysis (ANOVA) and Tukey's test (α= 5%). Results: The microstrain values (με) were (mean±SD): GA: 263.7±109.07με, and GB: 193.73±78.83με. Conclusion: There was no statistical difference between the two methods studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate and compare the reliability of implant-supported single crowns cemented onto abutments retained with coated (C) or noncoated (NC) screws and onto platform-switched abutments with coated screws. Materials and Methods: Fifty-four implants (DT Implant 4-mm Standard Platform, Intra-Lock International) were divided into three groups (n = 18 each) as follows: matching-platform abutments secured with noncoated abutment screws (MNC); matching-platform abutments tightened with coated abutment screws (MC); and switched-platform abutments secured with coated abutment screws (SC). Screws were characterized by scanning electron microscopy and x-ray photoelectron spectroscopy (XPS). The specimens were subjected to step-stress accelerated life testing. Use-level probability Weibull curves and reliability for 100,000 cycles at 200 N and 300 N (90% two-sided confidence intervals) were calculated. Polarized light and scanning electron microscopes were used for fractographic analysis. Results: Scanning electron microscopy revealed differences in surface texture; noncoated screws presented the typical machining grooves texture, whereas coated screws presented a plastically deformed surface layer. XPS revealed the same base components for both screws, with the exception of higher degrees of silicon in the SiO2 form for the coated samples. For 100,000 cycles at 300 N, reliability values were 0.06 (0.01 to 0.16), 0.25 (0.09 to 0.45), and 0.25 (0.08 to 0.45), for MNC, MC, and SC, respectively. The most common failure mechanism for MNC was fracture of the abutment screw, followed by bending, or its fracture, along with fracture of the abutment or implant. Coated abutment screws most commonly fractured along with the abutment, irrespective of abutment type. Conclusion: Reliability was higher for both groups with the coated screw than with the uncoated screw. Failure modes differed between coated and uncoated groups.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to gather information and discuss the predictability of implant-supported prostheses in patients with bruxism by performing a literature review. METHODS: In order to select the studies included in this review, a detailed search was performed in PubMed and Medline databases, using the following key words: bruxism, dental implants, implant supported prosthesis, and dental restoration failure. Items that were included are: case reports, randomized controlled trials, in vitro studies, literature and systematic reviews, with or without meta-analysis, of the last 20 years that addressed the theme. Articles without abstracts, animal studies, articles in languages other than English and articles from journals unrelated to the dental field were excluded. RESULTS: after analysis according to inclusion and exclusion criteria, 28 articles were selected from a total of 54. It is known from the array of scientific articles which have assessed, either through retrospective, prospective or experimental studies, that the biomechanical and biological impact of bruxism on implant-supported prostheses is small, and that the literature has contributed little to exemplify the prosthetic limits of safety for the specialist from a clinical point of view. CONCLUSION: Although there is still no general consensus on this matter, most of the literature review articles do provide clinical guidelines that contribute to implant supported prostheses longevity and stability in patients with bruxism.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To evaluate the aesthetics of an implant-supported denture at the cleft area, comparing the peri-implant tissues and prosthetic crown with the contralateral tooth. Settings: Hospital for Rehabilitation of Craniofacial Anomalies, Bauru, São Paolo, Brazil. Patients: A total of 39 individuals of both genders, with complete unilateral cleft lip and palate, who received secondary alveolar bone graft and were rehabilitated with single implant-supported dentures at the area of the missing maxillary lateral incisor after completion of orthodontic treatment. Interventions: The following parameters were analyzed in follow-up sessions: length and width of prosthetic crown and contralateral tooth, characteristics of implants, filling of interproximal space by the papilla, and smile height of the patients. Results: The implant-supported prosthetic crowns were longer than the contralateral tooth (p < .001). Among the 78 papillae analyzed, 29 (37.17%) received a score of 3; 32 (41.02%) papillae had a score of 2; and 17 (21.79%) received a score of 1. Concerning the smile height, among the 39 patients analyzed, 23 (56.41%) had a medium smile, 15 (38.46%) had a high smile, and two (5.12%) presented a low smile. Conclusion: The use of dental implants to rehabilitate the edentulous cleft area is an excellent option. However, adequate evaluation of the bone quantity and quality, positioning and shape of adjacent teeth, smile height, and patient expectations should be considered to achieve success and avoid aesthetic deformities such as elongated teeth and absence of gingival papillae.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this analysis was to assess and compare the 5- and 10-year survival of different types of tooth-supported and implant-supported fixed dental prostheses (FDPs) and single crowns (SCs), and to describe the incidence of biological and technical complications with emphasis on quality of reporting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The application of implant-borne rehabilitations in residual alveolar ridges may be restricted by various anatomic conditions, as available bone height and characteristics. Here we report the clinical outcome of implants placed in severely resorbed posterior ridges, in addition to various implant-supported treatment modalities. Extra Oral implants (Straumann, Basel, Switzerland) with the intraosseous length of 2.5–5mm were installed in the posterior alveolar ridges. Following the healing period of 4–6 months, implants were exposed and included in the distal extensions of fixed and removable prosthesis. At recall appointments were collected surgical, clinical and radiological variables, including the evidence of adverse effects. An 8-years life table analysis was calculated. The treatment protocol was applied in thirty-five patients, presenting 31 removable and 4 fixed complete implant-supported dentures. A total of 61 Extra Oral implants were placed posterior to the distal implants, at the mean distance of 29.8mm (range 15.6–62.7mm). Three implants failed during the osteointegration phase, yielding an 8-year cumulative success rate of 92.24%. Following the osteointegration period, no major bone loss or other adverse events were found. The clinical results indicated that the Extra Oral implants may be successfully used in addition to the other, longer implants. Thus, a relatively long extension in the posterior region may be employed. With careful preoperative planning, this technique offers a simple and beneficial complementary treatment option for removable and fixed complete dentures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES The aim of this case series was to introduce a complete digital workflow for the production of monolithic implant crowns. MATERIAL AND METHODS Six patients were treated with implant-supported crowns made of resin nano ceramic (RNC). Starting with an intraoral optical scan (IOS), and following a CAD/CAM process, the monolithic crowns were bonded either to a novel prefabricated titanium abutment base (group A) or to a CAD/CAM-generated individualized titanium abutment (group B) in premolar or molar sites on a soft tissue level dental implant. Economic analyses included clinical and laboratory steps. An esthetic evaluation was performed to compare the two abutment-crown combinations. RESULTS None of the digitally constructed RNC crowns required any clinical adaptation. Overall mean work time calculations revealed obvious differences for group A (65.3 min) compared with group B (86.5 min). Esthetic analysis demonstrated a more favorable outcome for the prefabricated bonding bases. CONCLUSIONS Prefabricated or individualized abutments on monolithic RNC crowns using CAD/CAM technology in a model-free workflow seem to provide a feasible and streamlined treatment approach for single-edentulous space rehabilitation in the posterior region. However, RNC as full-contour material has to be considered experimental, and further large-scale clinical investigations with long-term follow-up observation are necessary.