423 resultados para DISTRACTION OSTEOGENESIS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at investigating in vitro osteogenesis on three fluorcanasite glass-ceramic compositions with different solubilities (K3, K5, and K8). Osteoblastic cells were obtained from human alveolar bone fragments and cultured under standard osteogenic condition until subconfluence. First passage cells were cultured on K3, K5, and K8 and on Bioglass (R) 45S5 (45S5-control). Cell adhesion was evaluated at 24 h. For proliferation and viability, cells were cultured for 1, 4, and 10 days. Total protein content and alkaline phosphatase (ALP) activity were measured at 7, 14, and 21 days. Cultures were stained with Alizarin red at 21 days, for detection of mineralized matrix. Data were compared by ANOVA followed by Duncan`s test. Cell adhesion, cell proliferation, viability, total protein content, and ALP activity were not affected by fluorcanasite glass-ceramic composition and solubility. Bone-like formation was similar on all fluorcanasite-glass ceramics and was reduced compared to 45S5. The changes in the chemical composition and consequently solubility of the fluorcanasite glass-ceramics tested here did not significantly alter the in vitro osteogenesis. Further modifications of the chemical composition of the fluorcanasite glass-ceramic would be required to improve bone response, making this biomaterial a good candidate to be employed as a bone substitute.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The fixation and the bone ingrowth at the interface of porous cylindrical implants (total porosity of 37% and average pores diameter of 480 mu m) were compared in vivo to rough cylindrical implants (R-a = 5.3 mu m), both of commercially pure titanium, made by powder metallurgy. The implants were inserted into the tibias of 20 rabbits and the animals were sacrificed 4 and 8 weeks after surgery. The percentage of bone-implant contact observed in porous implant was significantly larger than in the rough ones for all of sacrifice periods, respectively, 57% vs. 46% after 4 weeks, and 59% vs. 50% after 8 weeks. The mechanical tests showed a significant increase in the shear strength of the porous implants for the two analyzed periods, 4 and 8 weeks (14 and 20 MPa), when compared with rough ones (4 and 13 MPa). These results suggest that porous implants improve the contact at the implant-bone interface and increase the fixation to the bone, improving the osseointegration. Thus, the porous implant might be an alternative to dental implant in less favorable conditions, and appear to be better fixed to bone, offering promising alternatives.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the healing at implants with a moderately rough surface placed and stabilized in recipient sites of dimensions deeper and larger than that of the implants to avoid any contact between parent bone and the implant.Material & methods: In six Labrador dogs, premolars and first molars were extracted bilaterally in the mandible. After 3 months of healing, mucoperiosteal full-thickness flaps were elevated and the premolar area of the alveolar bony crest was selected. Three recipient sites were prepared to place three implants. One implant was used as control. The other two were placed in recipient sites which left a circumferentially and periapical prepared defect of 0.7 mm (small) and 1.2 mm (large), respectively. All implants were stabilized with passive fixation plates to maintain the implants stable and without any contact with the implant bed. After 3 months of submerged healing, the animals were sacrificed. Ground sections were prepared and analyzed histomorphometrically.Results: The BIC% was 5.3% and 0.3% for implants placed in small and large defect sites, respectively, whereas it was 46.1% for control implants. The differences were statistically significant. The width of the residual defects was 0.4 and 0.5 mm at the small and large defects, respectively. An approximately 0.09 mm layer of dense connective tissue (DCT) rich in fibers and fibroblast-like cells was observed adherent to the implant surfaces. The percentage of implant surface covered by DCT was 92.8% and 95.6% at the small and large defects, respectively.Conclusion: Osseointegration was observed at the test sites, and the dimensions of the defects influenced the outcomes. However, the degree of osseointegration at both small and large defects was very low compared with the control sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effects of the morphology and physicochemical properties of calcium phosphate (CaP) nanoparticles on osteogenesis. Two types of CaP nanoparticles were compared, namely amorphous calcium phosphate (ACP) nano-spheres (diameter: 9-13 nm) and poorly crystalline apatite (PCA) nano-needles (30-50 nm x 2-4 nm) that closely resemble bone apatite. CaP particles were spin-coated onto titanium discs and implants; they were evaluated in cultured mouse calvarial osteoblasts, as well as after implantation in rabbit femurs. A significant dependence of CaP coatings was observed in osteoblast-related gene expression (Runx2, Col1a1 and Spp1). Specifically, the PCA group presented an up-regulation of the osteospecific genes, while the ACP group suppressed the Runx2 and Col1a1 expression when compared to blank titanium substrates. Both the ACP and PCA groups presented a more than three-fold increase of calcium deposition, as suggested by Alizarin red staining. The removal torque results implied a slight tendency in favour of the PCA group. Different forms of CaP nanostructures presented different biologic differences; the obtained information can be used to optimize surface coatings on biomaterials. © 2013 IOP Publishing Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteogenesis imperfecta (OI) is a Mendelian disease with genetic heterogeneity characterized by bone fragility, recurrent fractures, blue sclerae, and short stature, caused mostly by mutations in COL1A1 or COL1A2 genes, which encode the pro-alpha 1(I) and pro-alpha 2(I) chains of type I collagen, respectively. A Brazilian family that showed variable expression of autosomal dominant OI was identified and characterized. Scanning for mutations was carried out using SSCP and DNA sequence analysis. The missense mutation c.3235G>A was identified within exon 45 of the COL1A1 gene in a 16-year-old girl diagnosed as having OI type I; it resulted in substitution of a glycine residue (G) by a serine (S) at codon 1079 (p.G1079S). The proband's mother had the disease signs, but without bone fractures, as did five of nine uncles and aunts of the patient. All of them carried the mutation, which was excluded in four healthy brothers of the patient's mother. This is the first description in a Brazilian family with OI showing variable expression; only one among seven carriers for the c.3235G>A mutation developed bone fractures, the most striking clinical feature of this disease. This finding has a significant implication for prenatal diagnosis in OI disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Information regarding nutrition and body composition in patients diagnosed with osteogenesis imperfecta (OI) is scarce. In the present study, nutritional status, bone mineral density, and biochemical parameters of subjects with Of were evaluated. Methods: Patients with type I OI (n = 13) and type III OI (n = 13) and healthy controls (n = 8) were selected. Nutritional status and bone mineral density were assessed by a 3-d food diary and dual-energy X-ray absorptiometry at the lumbar spine, respectively. Body mass index, serum albumin, calcium, creatinine, cross-linked C-telopeptide, parathyroid hormone, and 25-hydroxivitamin D-3 were also evaluated. Results: Patients with OI had lower bone mineral density (P < 0.05 versus controls). Patients with type III OI had the highest body mass index (P < 0.05 versus patients with type I OI and controls) and the lowest lean body mass (P < 0.05 versus patients with type I OI and controls). In patients with OI, the number of fractures was positively correlated with body mass index (r = 0.581, P = 0.002) and the percentage of body fat (r = 0.451, P = 0.027) and negatively correlated to lean body mass (r = -0.523, P = 0.009). Even when taking dietary supplements, 58% and 12% of subjects with OI did not achieve the calcium and vitamin D recommendations, respectively. Conclusions: Body composition is a risk factor for bone fractures in subjects with OI. Individualized nutritional support is recommended not only to improve body composition but also to potentiate pharmacologic and physical therapies. (C) 2012 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A controlled, gradual distraction of the periosteum is expected to result in the formation of new bone. Purpose: This study was designed to estimate the possibility of new bone formation by periosteal distraction in a rat calvarium model. Material and Methods: Sixteen animals were subjected to a 7-day latency period and distraction rate at 0.4 mm/24 hours for 10 days. Two experimental groups with seven rats each were killed at 10 and 20 days of consolidation period and analyzed by means of microcomputed tomography, histologically and histomorphometry. Results: In the central regions underneath the disk device, signs of both bone apposition and bone resorption were observed. Peripheral to the disc, new bone was consistently observed. This new bone was up to two and three times thicker than the original bone after a 10- and 20-day consolidation period, respectively. Signs of ongoing woven bone formation indicated that the stimulus for new bone formation was still present. There were no statistically significant differences regarding bone density, bone volume, and total bone height between the two groups. Conclusion: The periosteal distraction model in the rat calvarium can stimulate the formation of considerable amounts of new bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

http://www.ncbi.nlm.nih.gov/pubmed/20014309

Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the broaden-and-build theory of positive emotions, positive emotions broaden while negative emotions narrow thought-action repertoires. These processes reflect changes in attentional scope, which is the focus of this research. The present study tested the hypothesis that participants in negative mood would be better able to focus on a target figure and separate it from its context in a perceptual task, and would also be better able to focus on the task amid a distracting environment than participants in a positive mood. An undergraduate sample of 77 participants watched video clips selected to induce either fear or amusement, and completed an Embedded Figures Test either in a quiet setting or in a noisy setting. A higher-order ANOVA revealed that Mood had a marginally significant effect on task performance, F(1, 73) = 3.94, p = .051, and that Distraction, F(1, 72) = 4.61, p = .035 and the Mood x Distraction interaction, F(1, 73) = 9.12, p = .003 did significantly affect task performance. However, contrary to the hypothesis, the effect of the distraction manipulation was greater for participants in a negative mood than it was for participants in a positive mood. The author suggests future directions to clarify the relationship between emotions, attentional scope, and susceptibility to environmental distraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: In alveolar distraction, in cases of severe atrophy in particular, it is often difficult to perform osteotomies in order to make a transport segment in optimal size and shape. Moreover care must be taken, not to damage the closely locating anato- mical structures such as the maxillary sinus, the inferior alveolar nerve, and the roots of the neighboring teeth. For setting ideal osteotomy lines exactly, we have developed a CT-based preoperative planning tool. Methods: 3-dimensional visual reconstruction of the jaw is created from the preoperative CT scans (1.0-mm slice thick- ness). Using the image-processing software Mimics (Materialise, Yokohama, Japan), various procedures of virtual cutting are simulated first to determine optimal osteotomy lines and to design an ideal transport segment. After the computer planning, data from the virtual solid model are transferred to a rapid prototype model, and a guiding splint is made to transfer the planned surgical simulation to the actual surgery. Results: The method was used in a case of severe atrophy of the anterior maxilla. The patient had a large maxillary sinus requir- ing a precise osteotomy in this critical area. Using the splint allowing a 3-dimensional guidance, alveolar osteotomies were easily done to achieve a transport segment in sufficient dimen- sion as planned, and any perforation of the maxillary sinus could be avoided. Finally the alveolar distraction of 10mm has suc- cessfully been performed. Conclusion: The preoperative planning method and the guiding splint described here are useful in problematic cases requiring an extremely precise osteotomy due to lack of bony space.