945 resultados para DIRECT ELECTRON-TRANSFER
Resumo:
Based on the Buttiker dephasing model, we propose an analytical scattering matrix approach to the long-range electron transfer phenomena. The present efficient scheme smoothly interpolates between the superexchange and the sequential hopping mechanisms. Various properties such as the drastic dephasing-assisted enhancement and turnover behaviors are demonstrated in good agreement with those obtained via the dynamical reduced density-matrix methods. These properties are further elucidated as results of the interplay among the dephasing strength, the tunneling parameter, and the bridge length of the electron transfer system. (C) 2001 American Institute of Physics.
Resumo:
We consider electron capture in fast collisions between a proton and hydrogen in the presence of an intense x-ray laser whose angular frequency omega is close to v(2)/2, where v is the collision velocity. We show that in such a case laser-induced capture becomes possible and that the latter proceeds via both induced photon emission and photon absorption channels and can, in principle, compete with kinematic and radiative electron capture.
Resumo:
We experimentally investigate the shell effect on the stabilization processes following the multi-electron transfer in slow collisions of Arq+-Ar (q = 6-9, It) The relative cross-section ratios of multi-electron transfer and of the subsequent stabilization with respect to single-electron capture are measured meanwhile compared with the theoretical results predicted by the classical over-barrier model. Our result indicates that the multi-electron transfer is dominant when the projectile charge is large and the subsequent stabilization shows a dramatic variation if the projectile L-shell configuration becomes open. It shows that the subsequent stabilization processes of multiply excited scattering ions have a strong dependence on the projectile shell. (C) 2010 Elsevier BV All rights reserved.
Resumo:
The structures, properties and electron transfer reactivity of the ClO/ClO+ coupling system are studied in this paper at ab initio (HF and MP2) levels and the density functional theory (DFT: B3LYP, B3P86, B3PW91) levels employing 6311 + G(3df) basis set and on the basis of the golden-rule of the time-dependent perturbation theory. Investigations indicate that the results got from the B3LYP method employing 6-311 + G(3df) basis set is in excellent agreement with the experiment. The activation energies, the stabilization energies and the electronic coupling matrix elements have also been calculated by using the B3LYP/6-311 + G(3df) method, and then the electron transfer rates are determined at this level. The electronic coupling matrix element of EC.6 is very small, only 0.03 kcal/mol, while that of EC.7 is the biggest, being 12.41 kcal/mol, the corresponding electron transfer rate is also the fastest among these seven encounter complexes. The averaged electron transfer rate is about 1.672 X 10(11) M-1 s(-1). It is indicated that the structures optimized by B3LYP method are more reliable than the results got from the other four methods. It also testified that the electronic coupling matrix element is the vital factor that significantly affects the electron transfer rate. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
The structures, properties and electron transfer reactivity of the ClO/ClO- coupling system are studied in this paper at ab initio (UHF and UMP2) levels and the Density Functional Theory (DFT: UB3LYP, UB3P86, UB3PW91) levels employing 6311 + G(3df) basis set and on the basis of the Golden-rule of the time-dependent perturbation theory. Investigations indicate that the results obtained using the UB3LYP method employing 6-311 + G(3df) basis set is in excellent agreement with the experiment. For this coupling system, six stable coupling modes have been found which correspond to six different encounter complexes and denote six different electron transfer mechanism: four O-O directly linked structures (one collinear: D-h, one anti-parallel: C-s, two twist: C-2) and two Cl-O linked structures (cis- and anti- C-s structures). The activation energies, the stabilization energies and the electronic coupling matrix elements have also been calculated for the electron transfer reactions via these six different mechanism at the UB3LYP/6-311 + G(3df) level, and then the electron transfer rates are determined at the same level. The most favorable coupling mode to the electron transfer is the anti-parallel mechanism. The averaged electron transfer rate is about 5.58 X 10(11) M-1 s(-1). It is also implied that the B3LYP method can give more reasonable results for the electron transfer reactivity of this system. (C) 2003 Elsevier B.V. All rights reserved.
Resumo:
Both the behavior and the general key factors for assembling flexible SWNT films at the water/oil interface were investigated; the electron transfer, one of the most fundamental chemical processes, at the SWNT-sandwiched water/oil interface was also firstly illustrated using scanning electrochemical microscopy.
Resumo:
It is discovered that SBA-15 (santa barbara amorphous) can provide the favorable microenvironments and optimal direct electron-transfer tunnels (DETT) of immobilizing cytochrome c (Cyt c) by the preferred orientation on it. A high-redox potential (254 mV vs. Ag/AgCl) was obtained on glassy carbon (GC) electrode modified by immobilizing Cyt c on rod-like SBA-15. With ultraviolet-visible (UV-vis), circular dichroism (CD), FTIR and cyclic voltammetry, it was demonstrated that immobilization made Cyt c exhibits stable and ideal electrochemical characteristics while the biological activity of immobilized Cyt c is retained as usual.
Resumo:
Multiwalled carbon nanotubes@SnO2-Au (MWCNTs@SnO2-Au) composite was synthesized by a chemical route. The structure and composition of the MWCNTs@SnO2-Au composite were confirmed by means of transmission electron microscopy, X-ray photoelectron and Raman spectroscopy. Due to the good electrocatalytic property of MWCNTs@SnO2-Au composite, a glucose biosensor was constructed by absorbing glucose oxidase (GOD) on the hybrid material. A direct electron transfer process is observed at the MWCNTs@SnO2-Au/GOD-modified glassy carbon electrode. The glucose biosensor has a linear range from 4.0 to 24.0 mM, which is suitable for glucose determination by real samples. It should be worthwhile noting that, from 4.0 to 12.0 mM, the cathodic peak currents of the biosensor decrease linearly with increasing the glucose concentrations in human blood. Meanwhile, the resulting biosensor can also prevent the effects of interfering species.
Resumo:
We first reported that polyvinylpyrrolidone-protected graphene was dispersed well in water and had good electrochemical reduction toward O-2 and H2O2. With glucose oxidase (GOD) as an enzyme model, we constructed a novel polyvinylpyrrolidone-proteeted graphene/polyethylenimine-ftmctionalized ionic liquid/GOD electrochemical biosensor, which achieved the direct electron transfer of GOD, maintained its bioactivity and showed potential application for the fabrication of novel glucose biosensors with linear glucose response up to 14 mM.
Resumo:
A sensing system based on the photoinduced electron transfer of quantum dots (QDs) was designed to measure the interaction of anticancer drug and DNA, taking mitoxantrone (MTX) as a model drug. MTX adsorbed on the surface of QDs can quench the photoluminescence (PL) of QDs through the photoinduced electron-transfer process; and then the addition of DNA will bring the restoration of QDs PL intensity, as DNA can bind with MTX and remove it from QDs. Sensitive detection of MTX with the detection limit of 10 nmol L-1 and a linear detection range from 10 nmol L-1 to 4.5 mu mol L-1 was achieved. The dependence of PL intensity on DNA amount was successfully utilized to investigate the interactions between MTX and DNA. Both the binding constants and the sizes of binding site of MTX-DNA interactions were calculated based on the equations deduced for the PL recovery process. The binding constant obtained in our experiment was generally consistent with previous reports. The sensitive and speedy detection of MTX as well as the avoidance of modification or immobilization process made this system suitable and promising in the drug-DNA interaction studies.