688 resultados para Défibrillateur cardiaque implantable


Relevância:

20.00% 20.00%

Publicador:

Resumo:

La mort subite est la première cause de mortalité chez les patients souffrant d'une insuffisance rénale terminale traités par dialyse chronique. La technique de dialyse utilisée et la composition chimique du dialysat influencent l'incidence des arythmies. Des études pilotes démontrent que l'utilisation d'un dialysat sans acétate avec perfusion de bicarbonate de sodium en aval du filtre de dialyse, couplée à une modulation du profil de potassium pendant la séance de dialyse, ou acetate free biofiltration with potassium profiled dialysate, permet de réduire l'incidence des arythmies, l'intervalle QT et sa dispersion. La limitation du volume de soustraction liquidienne pendant la dialyse et l'augmentation de la concentration de calcium dans le dialysat constituent d'autres stratégies anti-arythmogènes possibles Sudden death is the first cause of mortality in patients with end stage renal disease undergoing chronic dialysis treatment. The technique of dialysis as well as the chemical composition of the dialysate can impact on the incidence of cardiac arrhythmias. Pilot studies reveal that the use of an acetate-free dialysate with a downstream filter infusion of sodium bicarbonate, coupled with a modulated potassium-profiled dialysate during hemodialysis, or acetate free biofiltration with potassium profiled dialysate, reduces the incidence of arrhythmias, the QT interval and QT dispersion. The limitation of the ultrafiltration volume during the dialysis session, and the increase in calcium concentration in the dialysate are other possible strategies to reduce cardiac arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concomitant aortic and mitral valve replacement or concomitant aortic valve replacement and mitral repair can be a challenge for the cardiac surgeon: in particular, because of their structure and design, two bioprosthetic heart valves or an aortic valve prosthesis and a rigid mitral ring can interfere at the level of the mitroaortic junction. Therefore, when a mitral bioprosthesis or a rigid mitral ring is already in place and a surgical aortic valve replacement becomes necessary, or when older high-risk patients require concomitant mitral and aortic procedures, the new 'fast-implantable' aortic valve system (Intuity valve, Edwards Lifesciences, Irvine, CA, USA) can represent a smart alternative to standard aortic bioprosthesis. Unfortunately, this is still controversial (risk of interference). However, transcatheter aortic valve replacements have been performed in patients with previously implanted mitral valves or mitral rings. Interestingly, we learned that there is no interference (or not significant interference) among the standard valve and the stent valve. Consequently, we can assume that a fast-implantable valve can also be safely placed next to a biological mitral valve or next to a rigid mitral ring without risks of distortion, malpositioning, high gradient or paravalvular leak. This paper describes two cases: a concomitant Intuity aortic valve and bioprosthetic mitral valve implantation and a concomitant Intuity aortic valve and mitral ring implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'encéphalopathie post-anoxique après arrêt cardiaque (AC) est une cause féquente d'admission pour coma en réanimation. Depuis les recommandations de 2003, l'hypothermie thérapeutique (HT) est devenue un standard de traitement après AC et est à l'origine de l'amélioration du pronostic au cours de cette derniere décennie. Les élements prédicteurs de pronostic validés par l'Académie Américaine de Neurologie avant l'ère de l'HT sont devenus moins précis. En effet, l'HT et la sédation retardent la reprise de la réponse motrice et peuvent altérer la valeur prédictive des réflexes du tronc cérébral. Une nouvelle approche est nécessaire pour établir un pronostic après AC et HT. L'enregistrement (pendant l'HTou peu après) d'une activité électroencéphalographique réactive et/ou continue est un bon prédicteur de récupération neurologique favorable après AC. Au contraire, la présence d'un tracé non réactif ou discontinu de type burst-suppression, avec une réponse N20 absente bilatérale aux potentiels évoqués somatosensoriels, sont presqu'à 100 % prédictifs d'un coma irréversible déjà à 48 heures après AC. L'HT modifie aussi la valeur prédictive de l'énolase neuronale spécifique (NSE), principal biomarqueur sérique de la lésion cérébrale post-anoxique. Un réveil avec bonne récupération neurologique a été récemment observé par plusieurs groupes chez des patients présentant des valeurs de NSE>33 μg/L à 48-72 heures : ce seuil ne doit pas être utilisé seul pour guider le traitement. L'imagerie par résonance magnétique de diffusion peut aider à prédire les séquelles neurologiques à long terme. Un réveil chez les patients en coma post-anoxique est de plus en plus observé, malgré l'absence précoce de signes moteurs et une élévation franche des biomarqueurs neuronaux. En 2014, une nouvelle approche multimodale du pronostic est donc nécessaire, pour optimiser la prédiction d'une évolution clinique favorable après AC. Hypoxic-ischemic encephalopathy after cardiac arrest (CA) is a frequent cause of intensive care unit (ICU) admission. Incorporated in all recent guidelines, therapeutic hypothermia (TH) has become a standard of care and has contributed to improve prognosis after CA during the past decade. The accuracy of prognostic predictors validated in 2006 by the American Academy of Neurology before the era of TH is less accurate. Indeed, TH and sedation may delay the recovery of motor response and alter the predictive value of brainstem reflexes. A new approach is needed to accurately establish prognosis after CA and TH. A reactive and/or continuous electroencephalogram background (during TH or shortly thereafter) strongly predicts good outcome. On the contrary, unreactive/spontaneous burst-suppression electroencephalogram pattern, together with absent N20 on somatosensory evoked potentials, is almost 100% predictive of irreversible coma. TH also affects the predictive value of neuronspecific enolase (NSE), the main serum biomarker of postanoxic injury. A good outcome can occur despite NSE levels >33 μg/L, so this cutoff value should not be used alone to guide treatment. Diffusion magnetic resonance imagery may help predict long-term neurological sequelae. Awakening from postanoxic coma is increasingly observed, despite the absence of early motor signs and pathological elevation of NSE. In 2014, a multimodal approach to prognosis is recommended to optimize the prediction of outcome after CA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the agreement and repeatability of horizontal white-to-white (WTW) and horizontal sulcus-to-sulcus (STS) diameter measurements and use these data in combination with available literature to correct for interdevice bias in preoperative implantable collamer lens (ICL) size selection. DESIGN: Interinstrument reliability and bias assessment study. METHODS: A total of 107 eyes from 56 patients assessed for ICL implantation at our institution were included in the study. This was a consecutive series of all patients with suitable available data. The agreement and bias between WTW (measured with the Pentacam and BioGraph devices) and STS (measured with the HiScan device) were estimated. RESULTS: The mean spherical equivalent was -8.93 ± 5.69 diopters. The BioGraph measures of WTW were wider than those taken with the Pentacam (bias = 0.26 mm, P < .01), and both horizontal WTW measures were wider than the horizontal STS measures (bias >0.91 mm, P < .01). The repeatability (Sr) of STS measured with the HiScan was 0.39 mm, which was significantly reduced (Sr = 0.15 mm) when the average of 2 measures was used. Agreement between the horizontal WTW measures and horizontal STS estimates when bias was accounted for was г = 0.54 with the Pentacam and г = 0.64 with the BioGraph. CONCLUSIONS: Large interdevice bias was observed for WTW and STS measures. STS measures demonstrated poor repeatability, but the average of repeated measures significantly improved repeatability. In order to conform to the US Food and Drug Administration's accepted guidelines for ICL sizing, clinicians should be aware of and account for the inconsistencies between devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article is a systematic review of the available literature on the benefits that cognitive behavioral therapy (CBT) offers patients with implanted cardioverter defibrillators (ICDs) and confirms its effectiveness. After receiving the device, some patients fear that it will malfunction, or they remain in a constant state of tension due to sudden electrical discharges and develop symptoms of anxiety and depression. A search with the key words “anxiety”, “depression”, “implantable cardioverter”, “cognitive behavioral therapy” and “psychotherapy” was carried out. The search was conducted in early January 2013. Sources for the search were ISI Web of Knowledge, PubMed, and PsycINFO. A total of 224 articles were retrieved: 155 from PubMed, 69 from ISI Web of Knowledge. Of these, 16 were written in a foreign language and 47 were duplicates, leaving 161 references for analysis of the abstracts. A total of 19 articles were eliminated after analysis of the abstracts, 13 were eliminated after full-text reading, and 11 articles were selected for the review. The collection of articles for literature review covered studies conducted over a period of 13 years (1998-2011), and, according to methodological design, there were 1 cross-sectional study, 1 prospective observational study, 2 clinical trials, 4 case-control studies, and 3 case studies. The criterion used for selection of the 11 articles was the effectiveness of the intervention of CBT to decrease anxiety and depression in patients with ICD, expressed as a ratio. The research indicated that CBT has been effective in the treatment of ICD patients with depressive and anxiety symptoms. Research also showed that young women represented a risk group, for which further study is needed. Because the number of references on this theme was small, further studies should be carried out.