962 resultados para Current Control
Resumo:
Schistosomiasis control was impossible without effective tools. Synthetic molluscicides developed in the 1950s spearheaded community level control. Snail eradication proved impossible but repeated mollusciciding to manage natural snail populations could eliminate transmission. Escalating costs, logistical complexity, its labour-intensive nature and possible environmental effects caused some concern. The arrival of safe, effective, single-dose drugs in the 1970s offered an apparently better alternative but experience revealed the need for repeated treatments to minimise reinfection in programmes relying on drugs alone. Combining treatment with mollusciciding was more successful, but broke down if mollusciciding was withdrawn to save money. The provision of sanitation and safe water to prevent transmission is too expensive in poor rural areas where schistosomiasis is endemic; rendering ineffective public health education linked to primary health care. In the tropics, moreover, children (the key group in maintaining transmission) will always play in water. Large scale destruction of natural snail habitats remains impossibly expensive (although proper design could render many new man-made habitats unsuitable for snails). Neither biological control agents nor plant molluscicides have proved satisfactory alternatives to synthetic molluscicides. Biologists can develop effective strategies for using synthetic molluscicides in different epidemiological situations if only, like drugs, their price can be reduced.
Resumo:
Sustainability has become a focal point of the international agenda. At the heart of its range of distribution in the Gran Chaco Region, the elimination of Triatoma infestans has failed, even in areas subject to intensive professional vector control efforts. Chagas disease control programs traditionally have been composed of two divorced entities: a vector control program in charge of routine field operations (bug detection and insecticide spraying) and a disease control program in charge of screening blood donors, diagnosis, etiologic treatment and providing medical care to chronic patients. The challenge of sustainable suppression of bug infestation and Trypanosoma cruzi transmission can be met through integrated disease management, in which vector control is combined with active case detection and treatment to increase impact, cost-effectiveness and public acceptance in resource-limited settings. Multi-stakeholder involvement may add sustainability and resilience to the surveillance system. Chagas vector control and disease management must remain a regional effort within the frame of sustainable development rather than being viewed exclusively as a matter of health pertinent to the health sector. Sustained and continuous coordination between governments, agencies, control programs, academia and the affected communities is critical.
Resumo:
[Summary] 2. Roles of quality control in the pharmaceutical and biopharmaceutical industries. - 2.1. Pharmaceutical industry. - 2.2. Biopharmaceutical industry. - 2.3. Policy and regulatory. - 2.3.1. The US Food and Drug Administration (FDA). - 2.3.2. The European Medicine Agency (EMEA). - 2.3.3. The Japanese Ministry of Work, Labor and Welfare (MHLW). - 2.3.4. The Swiss Agency for Therapeutic Products (Swissmedic). - 2.3.5. The International Conference on Harmonization (ICH). - - 3. Types of testing. - 3.1. Microbiological purity tests. - 3.2. Physiochemical tests. - 3.3. Critical to quality steps. - 3.3.1. API starting materials and excipients. - 3.3.2. Intermediates. - 3.3.3. APIs (drug substances) and final drug product. - 3.3.4. Primary and secondary packaging materials fro drug products. - - 4. Manufacturing cost and quality control. - 4.1.1. Pharmaceutical manufacturing cost breakdown. - 4.1.2. Biopharmaceutical manufacturing cost breakdown. - 4.2. Batch failure / rejection / rework / recalls. - - 5. Future trends in the quality control of pharmaceuticals and biopharmaceuticals. - 5.1. Rapid and real time testing. - 5.1.1. Physio-chemicals testing. - 5.1.2. Rapid microbiology methods
Resumo:
The purpose of this study was to provide an in-depth assessment of current infection control practice trends in a group of practicing audiologists. The study investigated the extent to which Universal Precautions are applied in the clinical settings, the percentages of respondents familiar with general infection control nomenclature, and the future educational directives.
Resumo:
Microcontroller-based peak current mode control of a buck converter is investigated. The new solution uses a discrete time controller with digital slope compensation. This is implemented using only a single-chip microcontroller to achieve desirable cycle-by-cycle peak current limiting. The digital controller is implemented as a two-pole, two-zero linear difference equation designed using a continuous time model of the buck converter and a discrete time transform. Subharmonic oscillations are removed with digital slope compensation using a discrete staircase ramp. A 16 W hardware implementation directly compares analog and digital control. Frequency response measurements are taken and it is shown that the crossover frequency and expected phase margin of the digital control system match that of its analog counterpart.
Resumo:
A simple constant-current electrocutaneous stimulator for high-impedance loads using low-cost, standard high-voltage components is presented. A voltage-regulator powers an oscillator built across the primary of a transformer whose secondary delivers, after rectification, the high-voltage supply to switched current-mirrors in the driving stage. Since the compliance high-voltage is proportional to the stimulation current, overall power consumption is minimized. By adjusting the regulated voltage, control of the pulsed-current amplitude is achieved. A prototype with readily available components features stimulation currents of amplitude and pulsewidth in the range 0≤Iskin≤20mA and 50μs ≤Tpulse≤1ms, respectively. Pulse-repetition spans from 1 Hz to 10Hz. Worst-case ripple is 3.7% @Iskin=1mA. Measured pulse fall-time is shorter than 32μs. Overall consumption is 4.4W @Iskin=20mA. Subject isolation from line is 4KV.
Resumo:
Report on various facilities at the Texas Medical Center that are impacted by metro light rail transit operations
Resumo:
This study tested the hypothesis that career indecisiveness among men tends to be associated with different levels of self-reported psychological adjustment and with different remembrances of parental (maternal and paternal) acceptance and behavioral control in childhood from those of women. One hundred twenty-six respondents ages 17 through 54 (M = 23.7 years, SD = 8.21 years) participated in this study. Thirty-seven where males; 90 were females. Measures used in this study included the Career Decision Scale, the Adult version of the Parental Acceptance-Rejection/Control Questionnaire for mothers and for fathers, and the Adult version of the Personality Assessment Questionnaire. Both men and women remembered their mothers as well as their fathers as being loving in childhood. Additionally, men and women remembered both parents as being moderately behaviorally controlling in childhood. Finally, both men and women reported a fair level of psychological maladjustment. And on average, both men and women were fairly indecisive about their careers. Results of analyses supported the hypothesis in that career indecisiveness among women but not men was significantly correlated with remembered maternal and paternal acceptance in childhood, as well as with self-reported psychological adjustment and age. However, only women’s self-reported psychological adjustment made a significant and unique contribution to variations in their reports of career indecisiveness. None of the predictor variables were significantly associated with career indecisiveness among men.
Resumo:
High switching frequencies (several MHz) allow the integration of low power DC/DC converters. Although, in theory, a high switching frequency would make possible to implement a conventional Voltage Mode control (VMC) or Peak Current Mode control (PCMC) with very high bandwidth, in practice, parasitic effects and robustness limits the applicability of these control techniques. This paper compares VMC and CMC techniques with the V2IC control. This control is based on two loops. The fast internal loop has information of the output capacitor current and the error voltage, providing fast dynamic response under load and voltage reference steps, while the slow external voltage loop provides accurate steady state regulation. This paper shows the fast dynamic response of the V2IC control under load and output voltage reference steps and its robustness operating with additional output capacitors added by the customer.
Resumo:
The bandwidth achievable by using voltage mode control or current mode control in switch-mode power supply is limited by the switching frequency. Fast transient response requires high switching frequency, although lower switching frequencies could be more suitable for higher efficiency. This paper proposes the use of hysteretic control of the output capacitor $(C_{out})$ current to improve the dynamic response of the buck converter. An external voltage loop is required to accurately regulate the output voltage. The design of the hysteretic loop and the voltage loop are presented. Besides, it is presented a non-invasive current sensor that allows measuring the current in the capacitor. This strategy has been applied for DVS (dynamic voltage scaling) on a 5 MHz buck converter. Experimental results validate the proposed control technique and show fast transient response from 1.5 V to 2.5 V in 2 $mu{rm s}$.