955 resultados para Creación gold standard


Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study was aimed at assessing the psychometric qualities of the fast alcohol screening test (FAST), and at comparing these qualities to those of the alcohol use disorders identification test (AUDIT) in three samples of Brazilian adults: (i) subjects attended at an emergency department (530); (ii) patients from a psychosocial care center (40); and (iii) university students (429). The structured clinical interview for diagnosis (SCID)-IV was used as gold standard. The FAST demonstrated high test-retest and interrater reliability coefficients, as well as high predictive and concurrent validity values. The results attest the validity and reliability of the Brazilian version of the FAST for the screening of indicators of alcohol abuse and dependence.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE. This study aimed to assess the discriminative validity of the Brazilian version of the Patient Health Questionnaire (PHQ-9) and of its reduced version (PHQ-2). DESIGN AND METHODS. The sample consisted of 177 women (60 cases of depression and 117 noncases). The SCID-IV was used as the gold standard. FINDINGS. For the PHQ-9, a cutoff score equal to or higher than 10 proved to be the most adequate for the screening of depression, whereas the best cutoff score for the PHQ-2 was found to lie between 3 and 4. PRACTICE IMPLICATIONS. The systematic use of these instruments in nursing and in the context of primary health care could favor the early detection of depression.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The platelet blood count in laboratorial routine provides to the clinician important information about the hemostasis of the patient. There are many techniques described, however the gold standard techniques realized in hemocytometer spent a lot of time, making this technique impracticable in great routines. This research had the intent to evaluate if the automatic veterinary blood counter QBC Vet Autoread (R), whose results get five minutes to be ready, is capable to offer a trustworthy platelet count number. To this end, were evaluated the correlations among three different forms of platelets count in dogs: count in automatic blood counter QBC Vet Autoread (R), estimative in blood smear and the gold standard method by manual count in hemocytometer. The viability and confidence use of automatic blood counters of the medicine veterinary routine. Seventeen dogs were chosen randomly way, in the medical and surgical routine of HOVET-USP. The analysis revel high correlation between the hemocytometer and the estimative in blood smear (r=0,875) and between the hemocytometer and automatic blood count by QBC Vet Autoread (R) (r=0,939). Conclude that the platelet blood cont by QBC Vet Autoread (R), in addition to be fast, it`s more truthful when compared with estimative in blood smear, although the latter one also had elevated correlation. However, morphological analysis through the smears cannot be dismissed because none of the other two techniques evaluated have the ability to assess platelet morphological changes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Six of the short dietary questions used in the 1995 National Nutrition Survey (see box below) were evaluated for relative validity both directly and indirectly and for consistency, by documenting the differences in mean intakes of foods and nutrients as measured on the 24-hour recall, between groups with different responses to the short questions. 1. Including snacks, how many times do you usually have something to eat in a day including evenings? 2. How many days per week do you usually have something to eat for breakfast? 3. In the last 12 months, were there any times that you ran out of food and couldn’t afford to buy more? 4. What type of milk do you usually consume? 5. How many serves of vegetables do you usually eat each day? (a serve = 1/2 cup cooked vegetables or 1 cup of salad vegetables) 6. How many serves of fruit do you usually eat each day? (a serve = 1 medium piece or 2 small pieces of fruit or 1 cup of diced pieces) These comparisons were made for males and females overall and for population sub-groups of interest including: age, socio-economic disadvantage, region of residence, country of birth, and BMI category. Several limitations to this evaluation of the short questions, as discussed in the report, need to be kept in mind including: · The method for comparison available (24-hour recall) was not ideal (gold standard); as it measures yesterday’s intake. This limitation was overcome by examining only mean differences between groups of respondents, since mean intake for a group can provide a reasonable approximation for ‘usual’ intake. · The need to define and identify, post-hoc, from the 24-hour recall the number of eating occasions, and occasions identified by the respondents as breakfast. · Predetermined response categories for some of the questions effectively limited the number of categories available for evaluation. · Other foods and nutrients, not selected for this evaluation, may have an indirect relationship with the question, and might have shown stronger and more consistent responses. · The number of responses in some categories of the short questions eg for food security may have been too small to detect significant differences between population sub-groups. · No information was available to examine the validity of these questions for detecting differences over time (establishing trends) in food habits and indicators of selected nutrient intakes. By contrast, the strength of this evaluation was its very large sample size, (atypical of most validation studies of dietary assessment) and thus, the opportunity to investigate question performance in a range of broad population sub-groups compared with a well-conducted, quantified survey of intakes. The results of the evaluation are summarised below for each of the questions and specific recommendations for future testing, modifications and use provided for each question. The report concludes with some general recommendations for the further development and evaluation of short dietary questions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Quantitation of progesterone (P(4)) in biological fluids is often performed by radioimmunoassay (RIA), whereas liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) has been used much less often. Due to its autoconfirmatory nature, LC-MS/MS greatly minimizes false positives and interference. Herein we report and compare with RIA an optimized LC-MS/MS method for rapid, efficient, and cost-effective quantitation of P(4) in plasma of cattle with no sample derivatization. The quantitation of plasma P(4) released from three nonbiodegradable, commercial, intravaginal P(4)-releasing devices (IPRD) over 192 h in six ovariectomized cows was compared in a pairwise study as a test case. Both techniques showed similar P(4) kinetics (P > 0.05) whereas results of P(4) quantitation by RIA were consistently higher compared with LC-MS/MS (P < 0.05) due to interference and matrix effects. The LC-MS/MS method was validated according to the recommended analytical standards and displayed P(4) limits of detection (LOD) and quantitation (LOQ) of 0.08 and a 0.25 ng/mL, respectively. The high selective LC-MS/MS method proposed herein for P(4) quantitation eliminates the risks associated with radioactive handling; it also requires no sample derivatization, which is a common requirement for LC-MS/MS quantitation of steroid hormones. Its application to multisteroid assays is also viable, and it is envisaged that it may provide a gold standard technique for hormone quantitation in animal reproductive science studies. (C) 2011 Elsevier Inc. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Detection and quantification of human papillomavirus (HPV) may help in predicting the evolution of HPV infection and progression of associated lesions. Objectives: We propose a novel protocol using consensus primers GP5+/6+ in a SYBR Green quantitative real-time (Q-RT) polymerase chain reaction (PCR). The strategy permits screening for HPV infection and viral load quantification simultaneously. Study design: DNA from 153 archived cervical samples, previously tested for HPV detection by GP5+/6+ PCR and typed by EIA-RLB (enzyme immunoassay-reverse line blot) or sequence analysis, was analysed using SYBR Green Q-RT PCR. Melting temperature assay (T(m)) and cycle threshold (C(t)) were used to evaluate HPV positivity and viral load. The T(m) in the range of 77-82 degrees C was considered to be positive for HPV-DNA. HPV results generated through GP5+/6+ conventional PCR were considered the gold standard against which sensitivity and specificity of our assay were measured. Results: Out of 104 HPV positive samples, 100 (96.2%) were also determined as positive by SYBR Green Q-RT PCR; of the 49 HPV-negative samples, all were determined as negative. There was an excellent positivity agreement (K = 0.94) between the SYBR Green Q-RT and the previous methods employed. The specificity and sensitivity were 100% and 96.2%, respectively. Comparison of SYBR Green Q-RT and TaqMan oligo-probe technologies gave an excellent concordance (pc = 0.95) which validated the proposed strategy. Conclusions: We propose a sensitive and easy-to-perform technique for HPV screening and viral load quantification simultaneously. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: The aim of the present study was to evaluate the clinical efficacy of an experimental dentifrice (CH) containing an antimicrobial agent (1% chloramine-T). Materials and Methods: A clinical, fully randomised, double-blind comparative study was designed for 30 selected patients aged 15 to 50 years, with no periodontal disease, decay or other oral diseases, good general health and the presence of dental plaque and sulcus bleeding. Baseline Turesky modified plaque index (PI) and sulcus bleeding index (SBI) were scored for all patients. Volunteers randomly received the experimental dentifrice (CH) or a commercial-brand dentifrice containing triclosan (TR). Both dentifrices were provided in identical, number-labelled tubes, and the subjects were instructed to use the supplied dentifrice only for their usual oral hygiene, three times a day for a duration of 7 days. After 7-day use of dentifrices, the PI and SBI were assessed again. The data obtained were subjected to the Kruskal Wallis test, followed by Dunn`s post hoc test. Results: After 7-day use of dentifrices, the PI scores diminished significantly for both evaluated dentifrices. The SBI values decreased significantly for both experimental and commercial-brand dentifrices. Conclusions: Both dentifrices reduced PI and SBI. By comparing the experimental and gold-standard dentifrice, it was found that there was no statistically significant difference between the PI and SBI scores after their use, suggesting that they exerted a similar effect on the oral health indexes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

P>The aim of this study was to validate an original portable device to measure attachment retention of implant overdentures both in the lab and in clinical settings. The device was built with a digital force measurement gauge (Imada) secured to a vertical wheel stand associated with a customized support to hold and position the denture in adjustable angulations. Sixteen matrix and patrix cylindrical stud attachments (Locator (R)) were randomly assigned as in vitro test specimens. Attachment abutments were secured in an implant analogue hung to the digital force gauge or to the load cell of a traction machine used as the gold standard (Instron Universal Testing Machine). Matrices were secured in a denture duplicate attached to the customized support, permitting reproducibility of their position on both pulling devices. Attachment retention in the axial direction was evaluated by measuring maximum dislodging force or peak load during five consecutive linear dislodgments of each attachment on both devices. After a wear simulation, retention was measured again at several time periods. The peak load measurements with the customized Imada device were similar to those obtained with the gold standard Instron machine. These findings suggest that the proposed portable device can provide accurate information on the retentive properties of attachment systems for removable dental prostheses.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The insulin hypoglycemia test (IHT) is widely regarded as the 'gold standard' for dynamic stimulation of the hypothalamic-pituitary-adrenal (HPA) axis. This study aimed to investigate the temporal relationship between a rapid decrease in plasma glucose and the corresponding rise in plasma adenocorticotropic hormone (ACTH), and to assess the reproducibility of hormone responses to hypoglycemia in normal humans. Ten normal subjects underwent IHTs, using an insulin dose of 0.15 U/kg. Of these, eight had a second IHT (IHT2) and three went on to a third test (IHT3). Plasma ACTH and cortisol were measured at 15-min intervals and, additionally, in four IHT2s and the three IHT3s, ACTH was measured at 2.5- or 5-min intervals. Mean glucose nadirs and mean ACTH and cortisol responses were not significantly different between IHT1, IHT2 and IHT3. Combined data from all 21 tests showed the magnitude of the cortisol responses, but not the ACTH responses, correlated significantly with the depth and duration of hypoglycemia. All subjects achieved glucose concentrations of of less than or equal to 1.6 mmol/l before any detectable rise in ACTH occurred. In the seven tests performed with frequent sampling, an ACTH rise never preceeded the glucose nadir, but occurred at the nadir, or up to 15 min after. On repeat testing, peak ACTH levels varied markedly within individuals, whereas peak cortisol levels were more reproducible (mean coefficient of variation 7%). In conclusion, hypoglycemia of less than or equal to 1.6 mmol/l was sufficient to cause stimulation of the HPA axis in all 21 IHTs conducted in normal subjects. Nonetheless; our data cannot reveal whether higher glucose nadirs would stimulate increased HPA axis activity in all subjects. Overall, the cortisol response to hypoglycemia is more reproducible than the ACTH response but, in an individual subject, the difference in peak cortisol between two IHTs may exceed 100 nmol/l.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We have identified novel adjuvant activity in specific cytosol fractions from trophozoites of Giardia isolate BRIS/95/HEPU/2041 (J. A. Upcroft, P. A. McDonnell, and P. Upcroft, Parasitol. Today, 14:281-284, 1998). Adjuvant activity was demonstrated in the systemic and mucosal compartments when Giardia extract was coadministered orally with antigen to mice. Enhanced antigen-specific serum antibody responses were demonstrated by enzyme-linked immunosorbent. assay to be comparable to those generated by the gold standard, mucosal adjuvant cholera toxin. A source of adjuvant activity was localized to the cytosolic component of the parasite. Fractionation of the cytosol produced fraction pools, some of which, when coadministered with antigen, stimulated an enhanced antigen-specific serum response. The toxic component of conventional mucosal adjuvants is associated with adjuvant activity; therefore, in a similar way, the toxin-like attributes of BRIS/95/HEPU/2041 may be responsible for its adjuvanticity. Complete characterization of the adjuvant is under way.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The flock-level sensitivity of pooled faecal culture and serological testing using AGID for the detection of ovine Johne's disease-infected flocks were estimated using non-gold-standard methods. The two tests were compared in an extensive field trial in 296 flocks in New South Wales during 1998. In each flock, a sample of sheep was selected and tested for ovine Johne's disease using both the AGID and pooled faecal culture. The flock-specificity of pooled faecal culture also was estimated from results of surveillance and market-assurance testing in New South Wales. The overall flock-sensitivity of pooled faecal culture was 92% (95% CI: 82.4 and 97.4%) compared to 61% (50.5 and 70.9%) for serology (assuming that both tests were 100% specific). In low-prevalence flocks (estimated prevalence

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Indicators are valuable tools used to measure progress towards a desired health outcome. Increased awareness of the public health burden due to injury has lead to a concomitant interest in monitoring the impact of national initiatives that aim to reduce the size of the burden. Several injury indicators have now been proposed. This study examines the ability of each of the suggested indicators to reflect the nature and extent of the burden of non-fatal injury. A criterion validity, population-based, prospective cohort study was conducted in Brisbane, a sub-tropical Metropolitan City on the eastern seaboard of Australia, over a 12-month period between 1 January and 31 December 1998. Neither the presence of a long bone fracture nor the need for hospitalisation for 4 or more days were sensitive or specific indicators for 'serious' or major injury as defined by the 'Gold Standard' Injury Severity Score (ISS). Subsequent analysis, using other public health outcome measures demonstrated that the major component of the illness burden of injury was in fact due to 'minor' not serious injury. However, the suggested indicators demonstrated low sensitivity and specificity for these outcomes as well. The results of the study support the need to include at least all hospitalisations in any population-based measure of injury and not attempt to simplify the indicator to a more convenient measure aimed at identifying just those cases of,serious' injury.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A resistência a fármacos antituberculose tem constituído uma grande ameaça ao controle da tuberculose em âmbito mundial. A sua detecção precoce permite ao médico instituir um esquema de tratamento mais adequado ao paciente e consequentemente quebrar a cadeia de transmissão dos bacilos. Os testes de sensibilidade a antimicrobianos atuais, embora eficientes, são caros e/ou demorados e/ou trabalhosos. Com base nesta premissa, nos propusemos a desenvolver e padronizar um método fenotípico direto para determinação da sensibilidade do Mycobacterium tuberculosis a antimicrobianos de primeira linha do tratamento da tuberculose. Para o desenvolvimento deste novo teste, utilizaram-se os princípios do método das proporções e do exame de cultura pelo método de Ogawa–Kudoh. O estudo foi dividido em duas fases. A primeira, caracterizada pelo desenvolvimento e padronização do método proposto e a segunda, pela análise da concordância entre o método desenvolvido e o método do MGIT (padrão-ouro). Na primeira fase, foram realizados diversos ensaios para definir: os volumes de absorção e de liberação de líquidos de diferentes tipos de swab, o meio de cultura, as concentrações dos antimicrobianos e o tempo de leitura/interpretação das culturas. Além disso, foi verificado se a amostra deveria ou não ser diluída. Com base nos resultados destes ensaios, padronizou-se o método com: swab comercial, em meio de cultura Ogawa- Kudoh contendo separadamente 0,2 μg/mL de isoniazida, 40,0 μg/mL de rifampicina, 10,0 μg/mL de estreptomicina e 500,0 μg/mL de ácido para-nitrobenzóico. Padronizou-se ainda a inoculação da amostra de escarro de forma direta, ou seja, sem diluir e a leitura/interpretação do resultado do teste no período entre 21 e 28 dias. A análise comparativa entre este método e o teste de sensibilidade a antimicrobianos no sistema MGIT realizada na segunda fase do projeto indicou um índice kappa igual a 1,000, ou seja, uma concordância muito boa em relação ao padrão-ouro. Diante desses resultados promissores, acreditamos que o método desenvolvido apresente um grande potencial para ser utilizado em laboratórios com pouca infra-estrutura, por ser de baixo custo, fácil execução e relativamente rápido.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O Streptococcus pyogenes do grupo A (SGA) é o agente etiológico mais comum das faringoamigdalites (FA). O diagnóstico etiológico correto e tratamento adequado evitam complicações supurativas e não-supurativas da faringoamigdalite estreptocócica, entretanto, métodos clínicos de diagnóstico não são confiáveis. Os métodos rápidos de detecção do antígeno do SGA podem ser utilizados no diagnóstico deste agente e evitar uso indevido de antibióticos. OBJETIVOS: Os autores objetivaram avaliar a sensibilidade e especificidade dos testes rápidos para detecção do antígeno do SGA em nosso meio. FORMA DE ESTUDO: Clínico prospectivo. CASUÍSTICA E MÉTODO: Oitenta e um pacientes com faringoamigdalite aguda, atendidos no PS-ORL do Hospital das Clínicas da FMUSP, no período de maio de 2001 a abril de 2002, foram submetidos a duas coletas simultâneas de material de orofaringe com swabs. O teste rápido de detecção do SGA foi confrontado com a cultura em placa agar-sangue ("gold standard" para o diagnóstico etiológico). RESULTADOS: De 81 pacientes, 56% tiveram teste rápido positivo e 44% negativo; 40.7% apresentaram crescimento de SGA na cultura; a sensibilidade e especificidade do teste rápido foram, respectivamente, 93,9% e 68,7%. O valor preditivo negativo e positivo foram, respectivamente, 94,2% e 67,4%. COMENTÁRIOS FINAIS: A alta sensibilidade do exame permite utilizá-lo com intuito de identificar pacientes com SGA. Os testes de detecção rápida do antígeno estreptocócico se mostraram uma importante arma coadjuvante no diagnóstico etiológico das faringoamigdalites.