929 resultados para Comportamento térmico em ambiente construído
Resumo:
This study aims to compare the thermal performance of tiles made from recycled material (waste packaging cardboard with aluminized film) with the tiles of fiber and bitumen, fiber cement and red ceramic with the aim of verifying the suitability of tile to be used in hot and humid climate of low latitude. The samples were selected according to the availability from Natal - RN market, as they are sold to the consumers. The methodology was based on studies that used experimental apparatus composed of thermal chambers heated by banks of incandescent bulbs, to analyze the thermal performance of materials. The tiles in the study were submitted to analysis of thermal performance, thermophysical properties and absorptance, using chambers of thermal performance, measuring the thermophysical properties and portable spectrometer, respectively. Comparative analysis of thermal performance between two samples of the recycled material with dimple sizes and different amounts of aluminum were made, in order to verify, if these characteristics had some interference on the thermal performance of them; the results showed no significant performance differences between the samples. The data obtained in chambers of thermal performance and confirmed by statistical analysis, showed, that the tile of recycled material have similar thermal performance to the tile of fiber cement. In addition to these tests was carried out the automatic monitoring of a building covered with tiles of recycled material, to verify its thermal performance in a real situation. The results showed that recycled shingles must be used with technical criteria similar to those used for fiber cement tiles, with regard to the heat gain into the building. Within these criteria should be taken into account local characteristics, especially in regions with hot and humid climate, and its use must be associated, according to the literature, to elements of thermal insulation and use of passive techniques such as vented attics, ceilings and right foot higher
Resumo:
This research covers the topic of social housing and its relation to thermal comfort, so applied to an architectural and urban intervention in land situated in central urban area of Macaíba/RN, Brazil. Reflecting on the role of design and use of alternative building materials in the search for better performance is one of its main goals. The hypothesis is that by changing design parameters and choice of materials, it is possible to achieve better thermal performance results. Thus, we performed computer simulations of thermal performance and natural ventilation using computational fluid dynamics or CFD (Computational Fluid Dynamics). The presentation of the thermal simulation followed the methodology proposed in the dissertation Negreiros (2010), which aims to find the percentage of the amount of hours of comfort obtained throughout the year, while data analysis was made of natural ventilation from images generated by the images extracted from the CFD. From model building designed, was fitted an analytical framework that results in a comparison between three different proposals for dwellings housing model, which is evaluated the question of the thermal performance of buildings, and also deals with the spatial variables design, construction materials and costs. It is concluded that the final report confirmed the general hypotheses set at the start of the study, it was possible to quantify the results and identify the importance of design and construction materials are equivalent, and that, if combined, lead to gains in thermal performance potential.
Resumo:
The recent tendency to utilize parking lots for other purposes has demonstrated that more time has been spent by visitors, mainly in great cities. Therefore, this paper investigates the thermal comfort and the air quality indoors in areas specifically used as parking lots by analyzing the direct relation between such environments and vehicular pollution. The thermal comfort and the quality of air indoors in parking lots with different architectonic typology (ground-floor and underground) are also studied, aiming to contribute to the proposition of suitable new areas designated to human usage. Field research was done, in two distinct periods within different weather conditions (January and July) in, two naturally cooled, parking lots located in Natal - RN. The internal environment agents were measured by using tools for air temperature, humidity, speed and direction; interviews with employees and visitors and chemical analysis through appropriate tools to analyze specific material, carbon monoxide and ozone. The results showed that chemical agents densely concentrate mostly in the closed parking space, aggravated by weather conditions, which dissatisfied the visitors. Still, it was shown that architectonic typology, alongside topographical aspects compromise internal environmental conditions, which increases the retention of pollution, leading to dissatisfactory thermal comfort levels and becoming less suitable for usage by visitors considering air and thermal comfort aspects. Consequently, they are not suitable for human stay due to the poor quality of the indoor air
Resumo:
This study was intended to investigate how the urban form has been influencing the changes in the climate of the city and make a correlation between the climate and the thermal sensation of the users of open spaces. The research was developed in the district of Petrópolis in Natal/ RN whose occupation has been almost consolidated. Among other reasons, this district was selected because it was planned considering the environmental aspects of comfort. The methodologies used are based on KATZSCHNER (1997) and OLIVEIRA (1988) studies, which suggest the drawing and analysis of maps of the area under study, including topography, height of the buildings, land use, green areas, and types of soil pavement, as well as measurement of the environmental variables: air temperature, relative humidity, direction and wind speed for a comparative study. As part of this, study local users of the district were interviewed about their thermal sensations in open spaces. For the statistical analysis, data was collected at 10 distinct points characterized by BUSTOS ROMERO (2002), being 8 within the district and 2 at different places (outside the district), at climatologic stations, in 3 periods (August/2000, January/2002 and June/2002), for 4 consecutive days for each measurement (from Sunday to Wednesday) at the time of lower and higher temperatures in the city, 6:00 am and 1:00 pm, respectively. At the same time interviews were carried out with users of the open spaces in the area, totaling 171 valid formularies. The urban form showed a rather leveled topography, great diversity of land use and height of the buildings, with the existence of an area mostly occupied with high buildings, very little green area and soil practically impermeable. The statistical analysis showed high temperature and humidity levels. The wind direction is predominantly Southeast with extremely variable speeds. When the data from this district is compared with the data from other areas in the city and its outskirt, it was observed that this district is hotter and less ventilated than the others; besides, most users said that they felt uncomfortable in the local environmental conditions. The results of the analysis generated a zoning for the district with recommendations for soil occupation. The profile of the user was defined regarding the thermal comfort, as well as some discussion about the comfort parameters, including the proposal of limiting areas of temperature and humidity for the thermal comfort in the open spaces
Resumo:
Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study
Resumo:
Population growth experienced in major cities, allied to society s need of infra-structure, especially ones related to habitational demands, increases the consumption of construction materials. As a consequence, consumption of natural resources itself. Thus, due to this process, concrete is one of the most produced materials in civil construction. This is also due to the great diversity of its application, easiness in its execution and adequate mechanical performance, as well as low production costs. Following the same tendencies in construction development, the ceramic industry has intensified the production of porcelain ceramic tiles and floors. These are achieved by a fine finishing and receive polishing at the end of the fabrication process. This work researched the use of porcelain residues in polishing for the production of concrete. All of which; due to economical and environmental issues. This process aims to prove adequate destiny for this type of residue, due to environmental issues, incorporating it to the concrete itself; all of which provides economy in consumption of the materials that constitute concrete. Thus, the main characteristics of concrete were investigated through the inclusion of different concentration of the porcelain residue as additional trait element. The residue rates incorporated to the trait varied from 10% to 50% in relation to the cement mass, in the traits with plastic additives and without plastic additives. It is observed that the inclusion of porcelain residue produced a meaningful alteration in the consistency of fresh concrete. This residue has a fine granulometry and it considerably absorbed the water used in the concrete spreading, influencing the way this material is dealt with. Thus, the value of cement striking decreases with the increase of residues present in trait. The maximal incorporation of the residue was of 50%, massively, for the same factor water/initial cement. The use of residues in concrete results in an 40% increase in the compression resistance. It is also proportional to residue concentration of porcelain in the trait. The microstructure was also favored once porosity and concrete absorption decreases with the use of this residue. The parameters demonstrate the quality and durability of the concrete produced with this residue. The use of porcelain residue in concrete composition has not produced meaningful thermal behavior changes. Thermal conductivity, heat capacity and thermal diffusivity have been maintained basically constant
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Química - IQ
Resumo:
Pós-graduação em Geografia - FCT
Resumo:
A utilização de novas técnicas de aproveitamento de resíduos tem-se tornado cada vez mais importante na construção civil, principalmente quando se trata da utilização de resíduos de outros segmentos industriais e da redução de consumo de matérias-primas naturais. O objetivo deste estudo foi avaliar a utilização da lama vermelha, resíduo proveniente da produção de alumina metalúrgica, na produção de blocos cerâmicos vazados estruturais. A produção dos blocos foi realizada em uma indústria cerâmica, a partir de uma mistura de 60% de lama vermelha (LV) e de 40% de argila. Após a produção dos blocos, realizaram-se ensaios de acordo com as normas técnicas, tais como absorção de água e compressão axial simples. A partir da análise dos resultados, observou-se que os blocos estruturais produzidos a partir da mistura de LV e argila atenderam aos parâmetros normativos quanto ao índice de absorção de água e de resistência à compressão, e que as resistências médias e características desses blocos foram superiores às dos blocos cerâmicos de referência.
Resumo:
The aim of this research study was to evaluate the structural behaviour of the wood and concrete composite system for bridge decks with emphasis on the metal shear connectors. Experimental tests were performed on composite specimens and wood and concrete beams with a metallic connector system in an X position, using CS100900-type screws. All specimens and beams were submitted to static loads until failure in order to obtain the strength and stiffness of the connection system. The experimental results for the stiffness of the beams were compared with the analytical results obtained through the Mohler model, presenting good equivalence for service loads. The experimental results obtained demonstrate that the most significant damage in composite systems occurred in the connectors' areas.
Resumo:
This paper presents the results of a study on the thermal comfort in open urban spaces, undertaken in pedestrian streets located in the three towns, Campinas, Baurú, and Presidente Prudente, in the state of Sao Paulo. The study was developed as part of a more extensive project on thermal comfort in different kinds of open public spaces in Brazil. The methodology involved monitoring the microclimatic variables (air and globe temperature, humidity, air velocity and global solar radiation), and structured interviews, in order to assess the actual thermal comfort through the Actual Sensation Vote (ASV) and the personal users’ variables. The Physiological Equivalent Temperature (PET) was also calculated. The results show different limits for neutral temperature in each city: 20-29ºC for Campinas, 21-30 ºC for Bauru and 14-24 ºC for Presidente Prudente). However, 59.5% of the total sample (308 out of 519 individuals) indicated comfort limits ranging from 18 to 26 ºC, which is consistent with the limits proposed by Monteiro and Alucci for the city of Sao Paulo. These results can contribute to evaluate the thermal quality of other public spaces in the same towns.
Resumo:
Estratégias passivas de projeto reduzem significativamente o uso de ar condicionado e melhoram o conforto térmico dos usuários. Isto pode ser ilustrado através dos hospitais da Rede Sarah Kubitschek projetados pelo arquiteto João Filgueiras Lima, Lelé, cujas soluções além de propiciarem ambientes mais agradáveis e salubres, evitam o uso de sistemas mecânicos de resfriamento, reduzindo o consumo de energia elétrica. Deste modo, o presente artigo tem como objetivo avaliar o conforto térmico dos hospitais Sarah de Salvador e do Rio de Janeiro, através de medições in loco da temperatura do ar, umidade relativa do ar e velocidade do ar. A análise dos resultados foi baseada em leituras de projeto, na norma ASHRAE Standard 55/2004 e em parâmetros adquiridos na literatura especializada. Os resultados demonstram a preocupação de Lelé na incorporação de aspectos bioclimáticos nos projetos. No Sarah - Salvador, alguns ambientes permaneceram fora da zona de conforto no período do meio dia, devido ao ganho de calor pela cobertura. No entanto, o uso da ventilação natural auxilia no efeito de resfriamento, melhorando o conforto térmico nos espaços internos. Já no Sarah - Rio, todos os ambientes permanecem dentro da zona de conforto proposta pela ASHRAE 55.
Resumo:
Este trabalho apresenta os resultados iniciais de uma pesquisa, descrevendo o comportamento de usuários de edifícios de escritórios em relação às temperaturas de acionamento de ventiladores e aparelhos condicionadores de ar. Medições foram realizadas em quatro salas administrativas do Instituto de Arquitetura e Urbanismo de São Carlos – IAU/USP, nas quais foram registradas as temperaturas internas do ar e o momento de acionamento dos referidos equipamentos. Os valores registrados foram comparados à temperatura externa e à faixa de temperaturas de conforto descrita pela norma ASHRAE 55/2004. As temperaturas registradas de acionamento dos aparelhos condicionadores de ar e ventiladores são similares e estão dentro da faixa considerada confortável pela referida norma.