948 resultados para Column interns of Plasma
Resumo:
Metabolites produced by pathogenic fungi may be involved in the pathogenesis of fungal infections consequently altering the defence mechanisms of the host. In this study the levels of Paracoccidioides brasiliensis antigens detected in the plasma of patients with paracoccidioidomycosis correlated with the suppression index detected by the low mitogenic response of peripheral blood mononuclear cells (PBMC) to phytohaemaglutinin (PHA). This inhibitory effect on lymphoproliferation was observed in the plasma of 58% of the patients, suggesting the presence of inhibitory factors. Plasma samples from paracoccidioidomycosis patients having or not having inhibitory factors showed no significant effect on chromosomes of lymphocytes from healthy individuals, However, these plasmas had a suppressive activity on the blastogenic response of these lymphocytes stimulated with PHA, that was independent of a cytotoxic effect. P. brasiliensis antigens added to the proliferative response of PBMC from healthy individuals stimulated or not stimulated with PHA showed a dose-dependent suppressor effect, reproducing the inhibitory effect of patients' plasma. We suggest that the antigens of P, brasiliensis present in the plasma of patients, even at low concentrations, can play an important role in the reduction of the cellular immune response and in the genesis of the immuneregulatory disturbances observed in paracoccidioidomycosis.
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its applications to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study. In this paper, these images were used to confirm the existence of vortex structures in the flow induced by corona discharges on airfoil models. These structures are a possible explanation for the effects of drag reduction and lift force increasing, which have been reported in experiments of plasma assisted Aerodynamics.
Resumo:
This work describes an optical device for the simultaneous recording of shadowgrams and schlieren images, and some results are presented concerning its application to the study of plasma assisted flow control in airfoil models. This approach offers many advantages in comparison to other methods, specially because the use of tracer particles (like smoke in wind tunnels) is not required for the experiments, thus avoiding contaminations in the electric discharges or air flows. Besides, while schlieren images reveal the refractive index gradients in the area of study, shadowgrams detect the second order spatial derivatives of the refractive indexes. Therefore, the simultaneous recording of these different images may give interesting information about the phenomena under study.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: O objetivo deste estudo foi determinar o perfil da deficiência imune em um grupo bem definido de epilepsia: crianças com síndrome de West (SW) e seus padrões EEG de evolução, idade-dependentes, como os complexos onda-aguda- onda lenta generalizadas da síndrome de Lenox-Gastaut (SLG) e as pontas multifocais independentes (PMI). MÉTODO: Um grupo de 50 crianças, 33 com SW, 10 com SLG, 7 com PMI e 20 crianças sadias (controle) foram avaliadas em relação aos seguintes parâmetros:determinação de subpopulações de linfócitos T (CD1, CD3, CD4 e CD8), relação CD4/CD8 e resposta proliferativa de linfócitos frente a fitohemaglutinina (PHA), na presença de plasma autólogo ou de plasma AB (homólogo). A prova cutânea de sensibilização ao Dinitroclorobenzeno (DNCB) foi realizada apenas nos pacientes. Os níveis séricos de IgG, IgA e IgM foram comparados aos valores normais em crianças Brasileiras, em diferentes faixas etárias. RESULTADOS: A resposta ao DNCB foi ausente ou fracamente reativa em 76% dos pacientes. Níveis séricos elevados de IgG (45,7%) e de IgM (61,4%) e baixos de IgA (23,9%) foram detectados nos pacientes. A determinação das subpopulações de linfócitos T em sangue periférico mostrou: deficiência nas proporções de células CD3+ (p<0,05) e de CD4+ (p<0,05), aumento de CD8+ (p<0,01) e diminuição da relação CD4 / CD8 (p<0,001). A proporção de células CD1+ no grupo controle manteve-se menor que 3%, enquanto que em 18% dos pacientes esses níveis variaram entre 3 e 11%. A resposta proliferativa de linfócitos frente a PHA revelou índices blastogênicos significativamente mais baixos apenas quando células dos pacientes foram cultivadas na presença do próprio plasma (plasma autólogo). Quando estas células foram cultivadas na presença de plasma AB, não se evidenciou diferença significativa em relação ao grupo controle. CONCLUSÃO: A imunodeficiência na SW caracterizou-se por: anergia, alteração de imunidade mediada por células e dos níveis de imunoglobulinas, presença de timócitos imaturos na circulação periférica e deficiência funcional de linfócitos T induzida por fatores plasmáticos inibidores. Discutem-se as principais evidências de disfunção imune como imunodeficiência e autoimunidade.
Resumo:
In this work it was investigated the effect of the exposure to different plasmas on the wettability of silicone samples. We have observed that oxygen. argon, and hydrogen glow discharges are quite effective in reducing the water contact angle of such polymer. However, indifferently to efficiency of the treatment, practically all the modified surfaces recovered great part of their original hydrophobicity. We have investigated this hydrophobic recovery using surface energy measurements and theoretical simulations based on the exponential decay of the population of polar groups on the surface. According to our results such recovery can be attributed to the decrease of polar species at the interface water-polymer surface.
Resumo:
This work describes an XPS investigation of plasma-deposited polysiloxane films irradiated with 170 keV He+ ions at fluences, Phi, ranging from 1 x 10(14) to 1 x 10(16) cm(-2). Modifications in the atomic concentrations of the surface atoms with (D were revealed by changes in the [O]/[Si], [O]/[C] and [C]/[Si] atomic ratios. Surface chemical structure modifications were evidenced by the increasing C1s peak width and asymmetry as Phi was increased, due to the formation of ether and carboxyl functionalities. Moreover, structural transformations were indicated by the positive binding energy shift of the Si2p peaks, due to the increasing Si oxidation. Correlations of the XPS data with other results from previous work on polysiloxanes illustrate the role of ion beam-induced bond breaking on the structural modifications.
Resumo:
Polymer films were grown in rf discharges containing different proportions of C2H2 and SF6. Quantitative optical emission spectrometry (actinometry) was used to follow the trends in the plasma concentrations of the species H and F, and more tentatively, of CH, CF, and CF2, as a function of the feed composition. Infrared spectroscopy revealed the density of CH and CF bonds in the deposited material. As the partial pressure of SF6 in the feed was increased, the degree of fluorination of the polymer also rose. The form of the dependency of the deposition rate on the proportion of SF6 in the feed was in good qualitative agreement with the activated growth model. From transmission ultraviolet visible spectroscopy data the refractive index and the absorption coefficient of the polymers were calculated as a function of the deposition parameters. Since the optical gap depended to some extent upon the degree of fluorination, it could, within limits, be determined by a suitable choice of the proportion of SF6 in the feed. A qualitative explanation of this relationship is given.
Resumo:
The effect of magnetic field enhanced plasma immersion ion implantation (PIII) in silicon substrate has been investigated at low and high pulsed bias voltages. The magnetic field in magnetic bottle configuration was generated by two magnetic coils installed outside the vacuum chamber. The presence of both, electric and magnetic field in PIII creates a system of crossed E x B fields, promoting plasma rotation around the target. The magnetized electrons drifting in crossed E x B fields provide electron-neutral collision. Consequently, the efficient background gas ionization augments the plasma density around the target where a magnetic confinement is achieved. As a result, the ion current density increases, promoting changes in the samples surface properties, especially in the surface roughness and wettability and also an increase of implantation dose and depth. (C) 2012 Elsevier B. V. All rights reserved.
Resumo:
The aim of the present work was to evaluate plasma membrane integrity, motility, vigor and morphology of fresh and frozen goat spermatozoa with or without seminal plasma. Semen samples were diluted in Tris solution, before and after thawing, with a combination of carboxifluorescein diacetate and propidium iodide. The results showed differences (P < 0.01) for motility and minor defects in the presence or absence of seminal plasma, for both fresh and frozen samples. Periods of collection had a significant effect on motility, probably due to changes in the photoperiod. Plasma membrane integrity was significantly reduced by the freezing process, whether seminal plasma was present or absent. In conclusion, removal of seminal plasma decreased motility and vigor rates in frozen samples. The photoperiod probably decreased the testosterone level, contributing negatively to the high percentage of sperm abnormalities, mainly damaged membranes. The use of fluorescent probes allowed a better estimation of the percentage of functional cells, instead of only estimating the percentage of motile cells or morphology defects. © 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The biggest advantage of plasma immersion ion implantation (PIII) is the capability of treating objects with irregular geometry without complex manipulation of the target holder. The effectiveness of this approach relies on the uniformity of the incident ion dose. Unfortunately, perfect dose uniformity is usually difficult to achieve when treating samples of complex shape. The problems arise from the non-uniform plasma density and expansion of plasma sheath. A particle-in-cell computer simulation is used to study the time-dependent evolution of the plasma sheath surrounding two-dimensional objects during process of plasma immersion ion implantation. Before starting the implantation phase, steady-state nitrogen plasma is established inside the simulation volume by using ionization of gas precursor with primary electrons. The plasma self-consistently evolves to a non-uniform density distribution, which is used as initial density distribution for the implantation phase. As a result, we can obtain a more realistic description of the plasma sheath expansion and dynamics. Ion current density on the target, average impact energy, and trajectories of the implanted ions were calculated for three geometrical shapes. Large deviations from the uniform dose distribution have been observed for targets with irregular shapes. In addition, effect of secondary electron emission has been included in our simulation and no qualitative modifications to the sheath dynamics have been noticed. However, the energetic secondary electrons change drastically the plasma net balance and also pose significant X-ray hazard. Finally, an axial magnetic field has been added to the calculations and the possibility for magnetic insulation of secondary electrons has been proven.
Resumo:
Ti-6Al-4V samples have been treated by PHI processing at different temperatures (400-800°C), treatment time (30-150 min) and plasma potential (100 and 420 V). Hardness measurements results showed an enhancement of the hardness for all implanted samples. XRD results detected the Ti 2N phase and the best corrosion resistance was found for the samples processed at higher temperature and lower PIII time.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)