999 resultados para Coeficiente de transferência de calor médio
Resumo:
Pós-graduação em Química - IQ
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
This study aims to analyze the capacity of a helical coil heat exchanger to reach the requested heat transfer rates by a sodium hypochlorite production process. This heat exchanger was installed in an experimental way in order to reuse a source of low-temperatures water in such a way to become a more economical alternative than the existing cooling tower. Firstly, the concepts related to the theory of heat transfer applicable to the case were introduced. Then, the mapping of the main information about the production process and the technical specification of the current cooling system equipment's was realized. Using the dimensions of the heat exchanger installed today as reference, the calculations for determining the ideal length of the coil to different flows of hot fluid were performed. Finally, it was concluded that the heat exchanger currently employed does not provide heat transfer rates required for the maximum flow rate value supported by the cooling tower
Resumo:
This study aims to analyze the capacity of a helical coil heat exchanger to reach the requested heat transfer rates by a sodium hypochlorite production process. This heat exchanger was installed in an experimental way in order to reuse a source of low-temperatures water in such a way to become a more economical alternative than the existing cooling tower. Firstly, the concepts related to the theory of heat transfer applicable to the case were introduced. Then, the mapping of the main information about the production process and the technical specification of the current cooling system equipment's was realized. Using the dimensions of the heat exchanger installed today as reference, the calculations for determining the ideal length of the coil to different flows of hot fluid were performed. Finally, it was concluded that the heat exchanger currently employed does not provide heat transfer rates required for the maximum flow rate value supported by the cooling tower
Resumo:
Esse trabalho constitui o desenvolvimento da modelagem térmica e simulação por métodos numéricos de dois componentes fundamentais do ciclo de refrigeração por absorção de calor com o par amônia/água: o absorvedor e o gerador. A função do absorvedor é produzir mistura líquida com alta fração mássica de amônia a partir de mistura líquida com baixa fração mássica de amônia e mistura vapor mediante retirada de calor. A função do gerador é produzir mistura líquido/vapor a partir de mistura líquida mediante o fornecimento de calor. É proposto o uso da tecnologia de filmes descendentes sobre placas inclinadas e o método de diferenças finitas para dividir o comprimento da placa em volumes de controle discretos e realizar os balanços de massa, espécie de amônia e energia juntamente com as equações de transferência de calor e massa para o filme descendente. O objetivo desse trabalho é obter um modelo matemático simplificado para ser utilizado em controle e otimização. Esse modelo foi utilizado para calcular as trocas de calor e massa no absorvedor e gerador para diversas condições a partir de dados operacionais, tais como: dimensões desses componentes, ângulo de inclinação da placa, temperatura de superfície e condições de entrada da fase líquida e vapor. Esses resultados foram utilizados para estabelecer relações de causa e efeito entre as variáveis e parâmetros do problema. Os resultados mostraram que o ângulo de inclinação da placa ótimo tanto para o absorvedor como para o gerador é a posição vertical, ou 90°. A posição vertical proporciona o menor comprimento de equilíbrio (0,85 m para o absorvedor e 1,27 m para o gerador com as condições testadas) e se mostrou estável, pois até 75° não foram verificadas variações no funcionamento do absorvedor e gerador. Dentre as condições testadas para uma placa de 0,5 m verificou-se que as maiores efetividades térmicas no absorvedor e gerador foram respectivamente 0,9 e 0,7 e as maiores efetividades mássicas no absorvedor e gerador foram respectivamente 0,6 e 0,5. É esperado que os dados obtidos sejam utilizados em trabalhos futuros para a construção de um protótipo laboratorial e na validação do modelo.
Resumo:
Unripe banana flour (UBF) production employs bananas not submitted to maturation process, is an interesting alternative to minimize the fruit loss reduction related to inappropriate handling or fast ripening. The UBF is considered as a functional ingredient improving glycemic and plasma insulin levels in blood, have also shown efficacy on the control of satiety, insulin resistance. The aim of this work was to study the drying process of unripe banana slabs (Musa cavendishii, Nanicão) developing a transient drying model through mathematical modeling with simultaneous moisture and heat transfer. The raw material characterization was performed and afterwards the drying process was conducted at 40 ºC, 50 ºC e 60 ºC, the product temperature was recorded using thermocouples, the air velocity inside the chamber was 4 m·s-1. With the experimental data was possible to validate the diffusion model based on the Fick\'s second law and Fourier. For this purpose, the sorption isotherms were measured and fitted to the GAB model estimating the equilibrium moisture content (Xe), 1.76 [g H2O/100g d.b.] at 60 ºC and 10 % of relative humidity (RH), the thermophysical properties (k, Cp, ?) were also measured to be used in the model. Five cases were contemplated: i) Constant thermophysical properties; ii) Variable properties; iii) Mass (hm), heat transfer (h) coefficient and effective diffusivity (De) estimation 134 W·m-2·K-1, 4.91x10-5 m-2·s-1 and 3.278?10-10 m·s-2 at 60 ºC, respectively; iv) Variable De, it presented a third order polynomial behavior as function of moisture content; v) The shrinkage had an effect on the mathematical model, especially in the 3 first hours of process, the thickness experienced a contraction of about (30.34 ± 1.29) % out of the initial thickness, finding two decreasing drying rate periods (DDR I and DDR II), 3.28x10-10 m·s-2 and 1.77x10-10 m·s-2, respectively. COMSOL Multiphysics simulations were possible to perform through the heat and mass transfer coefficient estimated by the mathematical modeling.
Resumo:
Tese de mestrado integrado em Engenharia da Energia e do Ambiente, apresentada à Universidade de Lisboa, através da Faculdade de Ciências, 2016
Resumo:
The development of home refrigerators generally are compact and economic reasons for using simplified configuration. The thermodynamic coefficient of performance ( COP ) is limited mainly in the condenser design for reasons of size and arrangement ( layout ) of the project ( design ) and climatic characteristics of the region where it will operate. It is noteworthy that this latter limitation is very significant when it comes to a country of continental size like Brazil with diverse climatic conditions. The COP of the cycle depends crucially on the ability of heat dissipated in the condenser. So in hot climates like the northeast, north, and west-central dispel ability is highly attenuated compared to the south and southeast regions with tropical or subtropical climates when compared with other regions. The dissipation in compact capacitors for applications in domestic refrigeration has been the focus of several studies, that due to its impact on reducing costs and power consumption, and better use of the space occupied by the components of refrigeration systems. This space should be kept to a minimum to allow an increase in the useful storage volume of refrigerator without changing the external dimensions of the product. Due to its low cost manufacturing, wire on tube condensers continue to be the most advantageous option for domestic refrigeration. Traditionally, these heat exchangers are designed to operate under natural convection. Not always, the benefits of greater compactness of capacitors for forced outweigh the burden of pumping air through the external heat exchanger. In this work we propose an improvement in convective condenser changing it to a transfer mechanism combined in series with conductive pipes and wire to a moist convective porous medium and the porous medium to the environment. The porous media used in the coating was composed of a gypsum plaster impregnated fiber about a mesh of natural cellulosic molded tubular wire mesh about the original structure of the condenser , and then dried and calcined to greater adherence and increased porosity. The proposed configuration was installed in domestic refrigeration system ( trough ) and tested under the same conditions of the original configuration . Was also evaluated in the dry condition and humidified drip water under natural and forced with an electro - fan ( fan coil ) convection. Assays were performed for the same 134- refrigerant charge e under the same thermal cooling load. The performance was evaluated in various configurations, showing an improvement of about 72 % compared with the original configuration proposed in humidification and natural convection.
Resumo:
Nowadays, most of the hydrocarbon reserves in the world are in the form of heavy oil, ultra - heavy or bitumen. For the extraction and production of this resource is required to implement new technologies. One of the promising processes for the recovery of this oil is the Expanding Solvent Steam Assisted Gravity Drainage (ES-SAGD) which uses two parallel horizontal wells, where the injection well is situated vertically above the production well. The completion of the process occurs upon injection of a hydrocarbon additive at low concentration in conjunction with steam. The steam adds heat to reduce the viscosity of the oil and solvent aids in reducing the interfacial tension between oil/ solvent. The main force acting in this process is the gravitational and the heat transfer takes place by conduction, convection and latent heat of steam. In this study was used the discretized wellbore model, where the well is discretized in the same way that the reservoir and each section of the well treated as a block of grid, with interblock connection with the reservoir. This study aims to analyze the influence of the pressure drop and heat along the injection well in the ES-SAGD process. The model used for the study is a homogeneous reservoir, semi synthetic with characteristics of the Brazilian Northeast and numerical simulations were performed using the STARS thermal simulator from CMG (Computer Modelling Group). The operational parameters analyzed were: percentage of solvent injected, the flow of steam injection, vertical distance between the wells and steam quality. All of them were significant in oil recovery factor positively influencing this. The results showed that, for all cases analyzed, the model considers the pressure drop has cumulative production of oil below its respective model that disregards such loss. This difference is more pronounced the lower the value of the flow of steam injection
Resumo:
The post harvest cooling and/or freezing processes for horticultural products have been carried out with the objective of removing the heat from these products, allowing them a bigger period of conservation. Therefore, the knowledge of the physical properties that involve heat transference in the fig fruit Roxo de Valinhos is useful for calculating projects and systems of food engineering in general, as well as, for using in equations of thermodynamic mathematical models. The values of conductivity and thermal diffusivity of the whole fig fruit-rami index were determined, and from these values it was determined the value of the specific heat. For these determination it was used the transient method of the Line Heat Source. The results shown that the fig fruit has a thermal conductivity of 0.52 W m-1°C, thermal diffusivity of 1.56 x 10-7 m² s-1, pulp density of 815.6 kg m-3 and specific heat of 4.07 kJ kg-1 °C.
Resumo:
Mestrado em Engenharia Química
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Este trabalho surgiu no âmbito da Tese de Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química, aliando a necessidade da Empresa Monteiro Ribas – Indústrias, S.A. em resolver alguns problemas relacionados com as estufas da unidade J da fábrica de revestimentos. Outro dos objectivos era propor melhorias de eficiência energética neste sector da empresa. Para tal, foi necessário fazer um levantamento energético de toda a unidade, o que permitiu verificar que as estufas de secagem (Recobrimento 1 e 2) seriam o principal objecto de estudo. O levantamento energético da empresa permitiu conhecer o seu consumo anual de energia de 697,9 tep, o que a classifica, segundo o Decreto-lei nº 71 de 15 de Abril de 2008, como Consumidora Intensiva de Energia (CIE). Além disso, as situações que devem ser alvo de melhoria são: a rede de termofluido, que apresenta válvulas sem isolamento, o sistema de iluminação, que não é o mais eficiente e a rede de distribuição de ar comprimido, que não tem a estrutura mais adequada. Desta forma sugere-se que a rede de distribuição de termofluido passe a ter válvulas isoladas com lã de rocha, o investimento total é de 2.481,56 €, mas a poupança pode ser de 21.145,14 €/ano, com o período de retorno de 0,12 anos. No sistema de iluminação propõe-se a substituição dos balastros normais por electrónicos, o investimento total é de 13.873,74 €, mas a poupança é de 2.620,26 €/ano, com período de retorno de 5 anos. No processo de secagem das linhas de recobrimento mediram-se temperaturas de todos os seus componentes, velocidades de ar o que permitiu conhecer a distribuição do calor fornecido pelo termofluido. No Recobrimento 1, o ar recebe entre 39 a 51% do calor total, a tela recebe cerca de 25% e na terceira estufa este é apenas de 6%. Nesta linha as perdas de calor por radiação oscilam entre 6 e 11% enquanto as perdas por convecção representam cerca de 17 a 44%. Como o calor que a tela recebe é muito inferior ao calor recebido pelo ar no Recobrimento 1, propõe-se uma redução do caudal de ar que entra na estufa, o que conduzirá certamente à poupança de energia térmica. No Recobrimento 2 o calor fornecido ao ar representa cerca de 51 a 77% do calor total e o cedido à tela oscila entre 2 e 3%. As perdas de calor por convecção oscilam entre 12 e 26%, enquanto que as perdas por radiação têm valores entre 4 e 8%. No que diz respeito ao calor necessário para evaporar os solventes este oscila entre os 4 e 13%. Os balanços de massa e energia realizados ao processo de secagem permitiram ainda determinar o rendimento das 3 estufas do Recobrimento 1, com 36, 47 e 24% paras as estufa 1, 2 e 3, respectivamente. No Recobrimento 2 os valores de rendimento foram superiores, tendo-se obtido valores próximos dos 41, 81 e 88%, para as estufas 1, 2 e 3, respectivamente. Face aos resultados obtidos propõem-se a reengenharia do processo introduzindo permutadores compactos para aquecer o ar antes de este entrar nas estufas. O estudo desta alteração foi apenas realizado para a estufa 1 do Recobrimento 1, tendo-se obtido uma área de transferência de calor de 6,80 m2, um investimento associado de 8.867,81 €. e uma poupança de 708,88 €/ano, com um período de retorno do investimento de 13 anos. Outra sugestão consiste na recirculação de parte do ar de saída (5%), que conduz à poupança de 158,02 €/ano. Estes valores, pouco significativos, não estimulam a adopção das referidas sugestões.
Resumo:
A empresa Petibol, S.A. – Embalagens de plástico centra-se na produção de embalagens de plástico a partir da matéria-prima Poliestireno Expandido (EPS) e Polipropileno Expandido (EPP). A empresa possui uma preocupação ao nível da qualidade da água e do aproveitamento energético, tendo desta forma surgido a realização do estudo na unidade industrial, com o objectivo de anular e/ou diminuir as possíveis lacunas existentes na unidade industrial. Numa primeira etapa foi realizada uma caracterização global à qualidade da água e à empresa, actualizando-se os esquemas já existentes, contabilizando-se os custos actuais relativamente aos processos no circuito da água (arrefecimento, aquecimento e pressurização), e por fim, efectuou-se um levantamento in loco do circuito de água, relativamente à pressão, temperatura e caudal. Numa fase posterior, foram propostos equipamentos e processos, tendo em vista a colmatação dos problemas identificados, realizando-se um subsequente estudo relativamente aos custos inerentes a esses novos processos. A caracterização à água foi avaliada em diferentes pontos do circuito industrial, tendo-se determinado na Sala de Bombagem que o filtro de areia não possuía as dimensões mais apropriadas, existindo também um problema a nível mecânico associado ao processo de contra-lavagem. Tais factos podem ser a causa da ocorrência de um aumento do teor de sólidos após a passagem na camada filtrante. Relativamente ao amaciador, este deveria amaciar de forma completa a água para alimentação à caldeira, embora se tenha registado à saída do amaciador uma dureza de 21,3 mg/L, denunciando problemas na troca iónica. No que toca à água de alimentação à caldeira, verifica-se a existência de parâmetros que não se encontram de acordo com os critérios enunciados para uma óptima qualidade, sendo eles o pH (10,14), condutividade (363 μS/cm), teor de ferro (1,21 mg/L) e a dureza (16 mg/L). De salientar que somente o teor de cobre, que se encontra em quantidades vestigiais, apresenta-se de acordo com os valores impostos. No que respeita à água da caldeira, esta apresenta parâmetros incompatíveis com os recomendados, sendo eles a condutividade (7350 μS/cm), teor de sólidos dissolvidos (5248 mg/L) e alcalinidade total (780 mg/L). De referir que o valor de pH (11,8) não se encontra de acordo com a aplicação do tratamento “fosfato-pH coordenado”. Em relação aos parâmetros com valores que se encontram dentro dos limites, estes correspondem à dureza (0 mg/L), ao teor de fosfatos (45 mg/L) e teor de sílica (0 mg/L). A água do circuito de arrefecimento foi sujeita a uma análise microbiológica, que corroborou a presença de um biofilme. Um dos problemas enunciados pela empresa, prendia-se com a impossibilidade de descarga, no colector municipal, dos condensados dos compressores, visto apresentarem uma quantidade de óleo de cerca de 43,3 mg/L, equivalente a quatro vezes o valor limite de emissão, de acordo com a legislação municipal. Por fim, o efluente de descarga industrial apresenta um valor de pH (10,3) acima do intervalo permitido por lei (6,0 – 9,0), sendo que a corrente que mais contribui para este acréscimo de pH corresponde à corrente proveniente da água de purga, visto esta apresentar um valor de pH de 12,22. De maneira a contornar os parâmetros enunciados, é proposto a substituição do filtro de areia da Sala de Bombagem, assim como a inserção de um conjunto de medidas de remoção de ferro e desinfecção, sendo a conjugação de arejamento, coagulação, filtração e desinfecção, por parte do hipoclorito, a proposta apresentada. Aos condensados dos compressores é apresentado um sistema de separação, que possibilita a remoção do óleo da água, e uma consequente descarga da mesma. Actualmente, não existe qualquer filtro de areia no circuito de arrefecimento da água, sendo proposto assim esse equipamento, de forma a minorar o desenvolvimento da população microbiana, bem como a permitir uma maior eficiência na transferência de calor na torre de arrefecimento. Relativamente à descarga industrial, é recomendável a colocação de um sistema de regularização automática de pH. A inserção de uma válvula de três vias permite um aproveitamento energético e de água, a partir da confluência da água oriunda dos furos com a água do tanque de água fria, sendo posteriormente alimentada à central de vácuo. No estudo da recuperação energética, um outro equipamento avaliado correspondeu à serpentina, no entanto, verificou-se que a poupança no consumo de gás natural era de apenas 0,005%, o que não se mostrou uma proposta viável. O orçamento de todos os equipamentos é de 11.720,76 €, possibilitando não só um melhor funcionamento industrial, como um menor impacto a nível ambiental. Os custos futuros de funcionamento aumentam em 3,36%, tendo a pressurização um aumento do seu custo em 3,4% em relação ao custo actual, verificando-se um custo anual de 10.781,21€, em relação aos processos de arejamento, coagulação e desinfecção.