942 resultados para Capacitor placement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Neurophysiological monitoring aims to improve the safety of pedicle screw placement, but few quantitative studies assess specificity and sensitivity. In this study, screw placement within the pedicle is measured (post-op CT scan, horizontal and vertical distance from the screw edge to the surface of the pedicle) and correlated with intraoperative neurophysiological stimulation thresholds. METHODS: A single surgeon placed 68 thoracic and 136 lumbar screws in 30 consecutive patients during instrumented fusion under EMG control. The female to male ratio was 1.6 and the average age was 61.3 years (SD 17.7). Radiological measurements, blinded to stimulation threshold, were done on reformatted CT reconstructions using OsiriX software. A standard deviation of the screw position of 2.8 mm was determined from pilot measurements, and a 1 mm of screw-pedicle edge distance was considered as a difference of interest (standardised difference of 0.35) leading to a power of the study of 75 % (significance level 0.05). RESULTS: Correct placement and stimulation thresholds above 10 mA were found in 71 % of screws. Twenty-two percent of screws caused cortical breach, 80 % of these had stimulation thresholds above 10 mA (sensitivity 20 %, specificity 90 %). True prediction of correct position of the screw was more frequent for lumbar than for thoracic screws. CONCLUSION: A screw stimulation threshold of >10 mA does not indicate correct pedicle screw placement. A hypothesised gradual decrease of screw stimulation thresholds was not observed as screw placement approaches the nerve root. Aside from a robust threshold of 2 mA indicating direct contact with nervous tissue, a secondary threshold appears to depend on patients' pathology and surgical conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Accurate and reproducible tibial tunnel placement minimizing the risk of neurovascular damage is a crucial condition for successful arthroscopic reconstruction of the posterior cruciate ligament (PCL). This step is commonly performed under fluoroscopic control. Hypothesis: Performing the tibial tunnel under exclusive arthroscopic control allows accurate and reliable tunnel placement according to recommendations in the literature. Materials and Methods: Between February 2007 and December 2009, 108 arthroscopic single bundle PCL reconstructions in tibial tunnel technique were performed. The routine postoperative radiographs were screened according to previously defined quality criterions. After critical analysis, the radiographs of 48 patients (48 knees) were enrolled in the study. 10 patients had simultaneous ACL reconstruction and 7 had PCL revision surgery. The tibial tunnel was placed under direct arthroscopic control through a posteromedial portal using a standard tibial aming device. Key anatomical landmarks were the exposed tibial insertion of the PCL and the posterior horn of the medial meniscus. First, the centre of the posterior tibial tunnel outlet on the a-p view was determined by digital analysis of the postoperative radiographes. Its distance to the medial tibial spine was measured parallel to the tibia plateau. The mediolateral position was expressed by the ratio between the distance of the tunnel outlet to the medial border and the total width of the tibial plateau. On the lateral view the vertical tunnel position was measured perpendicularly to a tangent of the medial tibial plateau. All measurement were repeated at least twice and carried out by two examiners. Results: The mean mediolateral tunnel position was 49.3 ± 4.6% (ratio), 6.7 ± 3.6 mm lateral to the medial tibial spine. On the lateral view the tunnel centre was 10.1 ± 4.5 mm distal to the bony surface of the medial tibial plateau. Neurovascular damage was observed in none of our patients. Conclusion: The results of this radiological study confirm that exclusive arthroscopic control for tibial tunnel placement in PCL reconstruction yields reproducible and accurate results according to the literature. Our technique avoids radiation, facilitates the operation room setting and enables the surgeon to visualize the anatomic key landmarks for tibial tunnel placement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Audit report on the American Recovery and Reinvestment Act (ARRA) - Program of Competitive Grants for Worker Training and Placement in High Growth and Emerging Industry Sectors program for the Iowa Green Renewable Electrical Energy Network Inc. (IGREEN) for the year ended June 30, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article evaluates the results of portal vein (PV) stent placement in patients with malignant extrinsic lesions stenosing or obstructing the PV and causing symptomatic PV hypertension (PVHT). Fourteen patients with bile duct cancer (n = 7), pancreatic adenocarcinoma (n = 4), or another cancer (n = 3) underwent percutaneous transhepatic portal venous stent placement because of gastroesophageal or jejunal varices (n = 9), ascites (n = 7), and/or thrombocytopenia (n = 2). Concurrent tumoral obstruction of the main bile duct was treated via the transhepatic route in the same session in four patients. Changes in portal venous pressure, complications, stent patency, and survival were evaluated. Mean +/- standard deviation (SD) gradient of portal venous pressure decreased significantly immediately after stent placement from 11.2 mmHg +/- 4.6 to 1.1 mmHg +/- 1.0 (P < 0.00001). Three patients had minor complications, and one developed a liver abscess. During a mean +/- SD follow-up of 134.4 +/- 123.3 days, portal stents remained patent in 11 patients (78.6%); stent occlusion occurred in 3 patients, 2 of whom had undergone previous major hepatectomy. After stent placement, PVHT symptoms were relieved in four (57.1%) of seven patients who died (mean survival, 97 +/- 71.2 days), and relieved in six (85.7%) of seven patients still alive at the end of follow-up (mean follow-up, 171.7 +/- 153.5 days). Stent placement in the PV is feasible and relatively safe. It helped to relieve PVHT symptoms in a single session.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Single-center reports have identified retrograde ascending aortic dissection (rAAD) as a potentially lethal complication of thoracic endovascular aortic repair (TEVAR). METHODS AND RESULTS: Between 1995 and 2008, 28 centers participating in the European Registry on Endovascular Aortic Repair Complications reported a total of 63 rAAD cases (incidence, 1.33%; 95% CI, 0.75 to 2.40). Eighty-one percent of patients underwent TEVAR for acute (n=26, 54%) or chronic type B dissection (n=13, 27%). Stent grafts with proximal bare springs were used in majority of patients (83%). Only 7 (15%) patients had intraoperative rAAD, with the remaining occurring during the index hospitalization (n=10, 21%) and during follow-up (n=31, 64%). Presenting symptoms included acute chest pain (n=16, 33%), syncope (n=12, 25%), and sudden death (n=9, 19%) whereas one fourth of patients were asymptomatic (n=12, 25%). Most patients underwent emergency (n=25) or elective (n=5) surgical repair. Outcome was fatal in 20 of 48 patients (42%). Causes of rAAD included the stent graft itself (60%), manipulation of guide wires/sheaths (15%), and progression of underlying aortic disease (15%). CONCLUSIONS: The incidence of rAAD was low (1.33%) in the present analysis with high mortality (42%). Patients undergoing TEVAR for type B dissection appeared to be most prone for the occurrence of rAAD. This complication occurred not only during the index hospitalization but after discharge up to 1050 days after TEVAR. Importantly, the majority of rAAD cases were associated with the use of proximal bare spring stent grafts with direct evidence of stent graft-induced injury at surgery or necropsy in half of the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We developed a semiquantitative job exposure matrix (JEM) for workers exposed to polychlorinated biphenyls (PCBs) at a capacitor manufacturing plant from 1946 to 1977. In a recently updated mortality study, mortality of prostate and stomach cancer increased with increasing levels of cumulative exposure estimated with this JEM (trend p values = 0.003 and 0.04, respectively). Capacitor manufacturing began with winding bales of foil and paper film, which were placed in a metal capacitor box (pre-assembly), and placed in a vacuum chamber for flood-filling (impregnation) with dielectric fluid (PCBs). Capacitors dripping with PCB residues were then transported to sealing stations where ports were soldered shut before degreasing, leak testing, and painting. Using a systematic approach, all 509 unique jobs identified in the work histories were rated by predetermined process- and plant-specific exposure determinants; then categorized based on the jobs' similarities (combination of exposure determinants) into 35 job exposure categories. The job exposure categories were ranked followed by a qualitative PCB exposure rating (baseline, low, medium, and high) for inhalation and dermal intensity. Category differences in other chemical exposures (solvents, etc.) prevented further combining of categories. The mean of all available PCB concentrations (1975 and 1977) for jobs within each intensity rating was regarded as a representative value for that intensity level. Inhalation (in microgram per cubic milligram) and dermal (unitless) exposures were regarded as equally important. Intensity was frequency adjusted for jobs with continuous or intermittent PCB exposures. Era-modifying factors were applied to the earlier time periods (1946-1974) because exposures were considered to have been greater than in later eras (1975-1977). Such interpolations, extrapolations, and modifying factors may introduce non-differential misclassification; however, we do believe our rigorous method minimized misclassification, as shown by the significant exposure-response trends in the epidemiologic analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Iowa Department of Education surveyed Iowa’s 15 community colleges to gain information about each institution’s basic skill assessment requirements for placement into courses and programs. The survey asked what basic skill assessment(s) each institution uses, whether developmental course placement was mandatory, and what scores students needed to obtain to avoid being required or urged to take developmental courses in math, science, and reading. Additionally, staff members at each college were asked what the testing requirements are for students’ enrolled full time in high school that are taking community college classes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Reconstruction of the posterior cruciate ligament (PCL) yields less satisfying results than anterior cruciate ligament reconstruction with respect to laxity control. Accurate tibial tunnel placement is crucial for successful PCL reconstruction using arthroscopic tibial tunnel techniques. A discrepancy between anatomical studies of the tibial PCL insertion site and surgical recommendations for tibial tunnel placement remains. The objective of this study was to identify the optimal placement of the tibial tunnel in PCL reconstruction based on clinical studies. METHODS: In a systematic review of the literature, MEDLINE, EMBASE, Cochrane Review, and Cochrane Central Register of Controlled Trials were screened for articles about PCL reconstruction from January 1990 to September 2011. Clinical trials comparing at least two PCL reconstruction techniques were extracted and independently analysed by each author. Only studies comparing different tibial tunnel placements in the retrospinal area were included. RESULTS: This systematic review found no comparative clinical trial for tibial tunnel placement in PCL reconstruction. Several anatomical, radiological, and biomechanical studies have described the tibial insertion sites of the native PCL and have led to recommendations for placement of the tibial tunnel outlet in the retrospinal area. However, surgical recommendations and the results of morphological studies are often contradictory. CONCLUSIONS: Reliable anatomical landmarks for tunnel placement are lacking. Future randomized controlled trials could compare precisely defined tibial tunnel placements in PCL reconstruction, which would require an established mapping of the retrospinal area of the tibial plateau with defined anatomical and radiological landmarks.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IIn electric drives, frequency converters are used to generatefor the electric motor the AC voltage with variable frequency and amplitude. When considering the annual sale of drives in values of money and units sold, the use of low-performance drives appears to be in predominant. These drives have tobe very cost effective to manufacture and use, while they are also expected to fulfill the harmonic distortion standards. One of the objectives has also been to extend the lifetime of the frequency converter. In a traditional frequency converter, a relatively large electrolytic DC-link capacitor is used. Electrolytic capacitors are large, heavy and rather expensive components. In many cases, the lifetime of the electrolytic capacitor is the main factor limiting the lifetime of the frequency converter. To overcome the problem, the electrolytic capacitor is replaced with a metallized polypropylene film capacitor (MPPF). The MPPF has improved properties when compared to the electrolytic capacitor. By replacing the electrolytic capacitor with a film capacitor the energy storage of the DC-linkwill be decreased. Thus, the instantaneous power supplied to the motor correlates with the instantaneous power taken from the network. This yields a continuousDC-link current fed by the diode rectifier bridge. As a consequence, the line current harmonics clearly decrease. Because of the decreased energy storage, the DC-link voltage fluctuates. This sets additional conditions to the controllers of the frequency converter to compensate the fluctuation from the supplied motor phase voltages. In this work three-phase and single-phase frequency converters with small DC-link capacitor are analyzed. The evaluation is obtained with simulations and laboratory measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. OBJECTIVES: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. METHODS: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the 'Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. RESULTS: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. CONCLUSION: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.