993 resultados para Camp sites, facilities, etc.
Resumo:
Advertisements on front end-paper and fly-leaf.
Resumo:
Mode of access: Internet.
Resumo:
"February 1991."
Resumo:
Mode of access: Internet.
Resumo:
"Project: 87/137."
Resumo:
Generator 82 annual report; alphabetic list of hazardous waste generators -- Facility 82 annual report; alphabetic list of hazardous waste facilities.
Resumo:
Wagner-Camp (4th ed.)
Resumo:
"March 1979."
Resumo:
Prepared under contract (H-2002-R) with the Office of Policy Development and Research, Dept. of Housing and Urban Development, and Architectural and Transportation Barriers Compliance Board.
Resumo:
Mode of access: Internet.
Resumo:
Bibliography: leaf 106.
Resumo:
1 Adrenomedullin (AM) and calcitonin gene-related peptide (CGRP) have structural similarities, interact with each others receptors (calcitonin receptor-like receptor (CLR)/receptor-activity-modifying proteins (RAMPs)) and show overlapping biological activities. AM and CGRP receptors are chiefly coupled to cAMP production. In this study, a method of primary dissociated cell culture was used to investigate the presence of AM and CGRP receptors and their effects on cAMP production in embryonic spinal cord cells. 2 Both neuronal and non-neuronal CLR immunopositive cells were present in our model. 3 High affinity, specific [ 125I]-AM binding sites (K(d) 79±9 pM and B(max) 571±34 fmol mg -1 protein) were more abundant than specific [ 125I]-CGRP binding sites (K(d) 12±0.7 pM and B(max) 32±2 fmol mg -1 protein) in embryonic spinal cord cells. 4 Specific [ 125I]-AM binding was competed by related molecules with a ligand selectivity profile of rAM>hAM(22-52)>rCGRPα>CGRP(8-37) ≫[r-(r*,s*)]-N-[2-[[5-amino-1-[[4-(4-pyridinyl)-1-piperazinyl] carbonyl]pentyl]amino]-1-[(3,5-dibromo-4-hydroxyphenyl)methyl]-2-oxoethyl]-4-(1, 4-dihydro-2-oxo-3(2H)-quinazolinyl)-,1-piperidinecarboxamide (BIBN4096BS). 5 Specific [ 125I]-CGRP binding was competed by rCGRPα>rAM≥ CGRP(8-37)≥BIBN4096BS>hAM(22-52). 6 Cellular levels of cAMP were increased by AM (pEC"5"0 10.2±0.2) and less potently by rCGRPα (pEC"5"0 8.9±0.4). rCGRPα-induced cAMP accumulation was effectively inhibited by CGRP(8-37) (pA"2 7.63±0.44) and hAM(22-52) (pA"2 6.18±0.21) while AM-stimulation of cAMP levels was inhibited by CGRP(8-37) (pA"2 7.41±0.15) and AM(22-52) (pA"2 7.26±0.18). BIBN4096BS only antagonized the effects of CGRP (pA"2 8.40±0.30) on cAMP accumulation. 7 These pharmacological profiles suggest that effects of CGRP are mediated by the CGRP"1 (CLR/RAMP1) receptor in our model while those of AM are related to the activation of the AM"1 (CLR/RAMP2) receptor subtype. © 2006 Nature Publishing Group All rights reserved.
Resumo:
The calcitonin receptor-like receptor (CLR) acts as a receptor for the calcitonin gene-related peptide (CGRP) but in order to recognize CGRP, it must form a complex with an accessory protein, receptor activity modifying protein 1 (RAMP1). Identifying the protein/protein and protein/ligand interfaces in this unusual complex would aid drug design. The role of the extreme N-terminus of CLR (Glu23-Ala60) was examined by an alanine scan and the results were interpreted with the help of a molecular model. The potency of CGRP at stimulating cAMP production was reduced at Leu41Ala, Gln45Ala, Cys48Ala and Tyr49Ala; furthermore, CGRP-induced receptor internalization at all of these receptors was also impaired. Ile32Ala, Gly35Ala and Thr37Ala all increased CGRP potency. CGRP specific binding was abolished at Leu41Ala, Ala44Leu, Cys48Ala and Tyr49Ala. There was significant impairment of cell surface expression of Gln45Ala, Cys48Ala and Tyr49Ala. Cys48 takes part in a highly conserved disulfide bond and is probably needed for correct folding of CLR. The model suggests that Gln45 and Tyr49 mediate their effects by interacting with RAMP1 whereas Leu41 and Ala44 are likely to be involved in binding CGRP. Ile32, Gly35 and Thr37 form a separate cluster of residues which modulate CGRP binding. The results from this study may be applicable to other family B GPCRs which can associate with RAMPs.
Resumo:
Energy efficiency and user comfort have recently become priorities in the Facility Management (FM) sector. This has resulted in the use of innovative building components, such as thermal solar panels, heat pumps, etc., as they have potential to provide better performance, energy savings and increased user comfort. However, as the complexity of components increases, the requirement for maintenance management also increases. The standard routine for building maintenance is inspection which results in repairs or replacement when a fault is found. This routine leads to unnecessary inspections which have a cost with respect to downtime of a component and work hours. This research proposes an alternative routine: performing building maintenance at the point in time when the component is degrading and requires maintenance, thus reducing the frequency of unnecessary inspections. This thesis demonstrates that statistical techniques can be used as part of a maintenance management methodology to invoke maintenance before failure occurs. The proposed FM process is presented through a scenario utilising current Building Information Modelling (BIM) technology and innovative contractual and organisational models. This FM scenario supports a Degradation based Maintenance (DbM) scheduling methodology, implemented using two statistical techniques, Particle Filters (PFs) and Gaussian Processes (GPs). DbM consists of extracting and tracking a degradation metric for a component. Limits for the degradation metric are identified based on one of a number of proposed processes. These processes determine the limits based on the maturity of the historical information available. DbM is implemented for three case study components: a heat exchanger; a heat pump; and a set of bearings. The identified degradation points for each case study, from a PF, a GP and a hybrid (PF and GP combined) DbM implementation are assessed against known degradation points. The GP implementations are successful for all components. For the PF implementations, the results presented in this thesis find that the extracted metrics and limits identify degradation occurrences accurately for components which are in continuous operation. For components which have seasonal operational periods, the PF may wrongly identify degradation. The GP performs more robustly than the PF, but the PF, on average, results in fewer false positives. The hybrid implementations, which are a combination of GP and PF results, are successful for 2 of 3 case studies and are not affected by seasonal data. Overall, DbM is effectively applied for the three case study components. The accuracy of the implementations is dependant on the relationships modelled by the PF and GP, and on the type and quantity of data available. This novel maintenance process can improve equipment performance and reduce energy wastage from BSCs operation.
Resumo:
Résumé : Dans les couverts forestiers, le suivi de l’humidité du sol permet de prévenir plusieurs désastres tels que la paludification, les incendies et les inondations. Comme ce paramètre est très dynamique dans l’espace et dans le temps, son estimation à grande échelle présente un grand défi, d’où le recours à la télédétection radar. Le capteur radar à synthèse d’ouverture (RSO) est couramment utilisé grâce à sa vaste couverture et sa résolution spatiale élevée. Contrairement aux sols nus et aux zones agricoles, le suivi de l’humidité du sol en zone forestière est très peu étudié à cause de la complexité des processus de diffusion dans ce type de milieu. En effet, la forte atténuation de la contribution du sol par la végétation et la forte contribution de volume issue de la végétation réduisent énormément la sensibilité du signal radar à l’humidité du sol. Des études portées sur des couverts forestiers ont montré que le signal radar en bande C provient principalement de la couche supérieure et sature vite avec la densité de la végétation. Cependant, très peu d’études ont exploré le potentiel des paramètres polarimétriques, dérivés d’un capteur polarimétrique comme RADARSAT-2, pour suivre l’humidité du sol sur les couverts forestiers. L’effet du couvert végétal est moins important avec la bande L en raison de son importante profondeur de pénétration qui permet de mieux informer sur l’humidité du sol. L’objectif principal de ce projet est de suivre l’humidité du sol à partir de données radar entièrement polarimétriques en bandes C et L sur des sites forestiers. Les données utilisées sont celles de la campagne terrain Soil Moisture Active Passive Validation EXperiment 2012 (SMAPVEX12) tenue du 6 juin au 17 juillet 2012 au Manitoba (Canada). Quatre sites forestiers de feuillus ont été échantillonnés. L’espèce majoritaire présente est le peuplier faux-tremble. Les données utilisées incluent des mesures de l’humidité du sol, de la rugosité de surface du sol, des caractéristiques des sites forestiers (arbres, sous-bois, litières…) et des données radar entièrement polarimétriques aéroportées et satellitaires acquises respectivement, en bande L (UAVSAR) à 30˚ et 40˚ et en bande C (RADARSAT-2) entre 20˚ et 30˚. Plusieurs paramètres polarimétriques ont été dérivés des données UAVSAR et RADARSAT-2 : les coefficients de corrélation (ρHHVV, φHHVV, etc); la hauteur du socle; l’entropie (H), l’anisotropie (A) et l’angle alpha extraits de la décomposition de Cloude-Pottier; les puissances de diffusion de surface (Ps), de double bond (Pd) extraites de la décomposition de Freeman-Durden, etc. Des relations entre les données radar (coefficients de rétrodiffusion multifréquences et multipolarisations (linéaires et circulaires) et les paramètres polarimétriques) et l’humidité du sol ont été développées et analysées. Les résultats ont montré que 1) En bande L, plusieurs paramètres optimaux permettent le suivi de l’humidité du sol en zone forestière avec un coefficient de corrélation significatif (p-value < 0,05): σ[indice supérieur 0] linéaire et σ[indice supérieur 0] circulaire (le coefficient de corrélation, r, varie entre 0,60 et 0,96), Ps (r entre 0,59 et 0,84), Pd (r entre 0,6 et 0,82), ρHHHV_30˚, ρVVHV_30˚, φHHHV_30˚ and φHHVV_30˚ (r entre 0,56 et 0,81) alors qu’en bande C, ils sont réduits à φHHHV, φVVHV et φHHVV (r est autour de 0,90). 2) En bande L, les paramètres polarimétriques n’ont pas montré de valeur ajoutée par rapport aux signaux conventionnels multipolarisés d’amplitude, pour le suivi de l’humidité du sol sur les sites forestiers. En revanche, en bande C, certains paramètres polarimétriques ont montré de meilleures relations significatives avec l’humidité du sol que les signaux conventionnels multipolarisés d’amplitude.