986 resultados para CTD, Falmouth Scientific Instruments


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Herein is described a method by which component gases can be weighed as they are added one by one to a gas mixture. The float balance, designed for the purpose, is capable of determining a maximum mass of about 3 kg of a gas mixture contained in a cylinder of mass about 5 kg with a sensitivity of ±0·1 g mm-1 of the stem height.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A miniature furnace suitable for routine collection of x-ray data up to 1000°C from single crystals on the Hilger and Watts linear diffractometer, without restricting the normally allowed region of reciprocal space on the diffractometer, is described. The crystal is heated primarily by radiation from a surrounding current-heated, stationary platinum coil wound on a silica bracket. The coil is split at its middle to provide a 4 mm gap for crystal mounting and x-irradiation. The crystal, mounted on a standard goniometer head, can be rotated and centred freely, as in the room temperature case. There is no need for any radiation shields or water-cooling arrangement. Investigations up to 1500°C are possible with slight modifications of the furnace.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A split-cassette arrangement has been incorporated in the Weissenberg camera for recording all reflections on the upper level photographs either as elongated or as contracted spots. This arrangement employs two semicylindrical cassettes which are separated by a horizontal plane. These half-cassettes are translated in opposite directions. A suitable split-cassette attachment has been constructed for the Unicam Weissenberg goniometer S-35 The subject of 'displaced-film' Weissenberg photograph is also discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Temperature-time characteristics of tungsten filaments heated electrically under constant voltage in vacuum have been analysed. The analysis is carried out over the temperature range 300-2500°K, taking into account the actual variations with temperature of the various parameters involved, as reported by Jones and Langmuir (1927). The analysis leads to the conclusion that the temperature-time relationship is exponential throughout the range. The time constant is shown to be proportional to the diameter of the filament and T f-4.2 where Tf is the final temperature of the filament. The results of the analysis are applied to derive the voltage variations (continuous and discrete types) required to keep the transient current within specified limits during the rapid switching on of filaments as met with in high power thermionic valves.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The paper describes a simple instrument for the measurement of the peak amplitudes of impulse voltages up to 250 v with an accuracy to ±3%. The response of the instrument is fast enough to read the peak amplitude of a 0.5/10 μsec impulse wave and its response remains the same for impulses of longer duration. Its favourable response has been obtained by charging a capacitor through a thyratron and measuring the voltage across it by an inverted triode voltmeter. The discharge time constant of the instrument is 5000 sec so that the reading can be taken at leisure. It can be used for the measurement of peak amplitudes of repetitive impulse and power frequency voltages also

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Details of the design and operation of a Weissenberg camera suitable for x-ray investigations between -180°c and 200°c are presented. The camera employs a novel arrangement of spur and bevel gears to couple the goniometer spindle to the worm rod which controls the range of oscillation. The entire drive system and the goniometer assembly are mounted on a support which permits the insertion or removal of a cylindrical cassette from the gear-box side without disturbing the cooling assembly and the layer-line screen. The cassette can also be inserted from the opposite side. The specimen can be cooled either directly by a stream of liquid air or by the cold gas from its evaporation. Condensation of moisture at low temperatures is prevented by heating the layer-line tubes internally.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a dispenser type of ion emitter is described. This type of ion emitter has been used successfully for obtaining lead, aluminum, and tin ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

It has been shown that the conventional practice of designing a compensated hot wire amplifier with a fixed ceiling to floor ratio results in considerable and unnecessary increase in noise level at compensation settings other than optimum (which is at the maximum compensation at the highest frequency of interest). The optimum ceiling to floor ratio has been estimated to be between 1.5-2.0 ωmaxM. Application of the above considerations to an amplifier in which the ceiling to floor ratio is optimized at each compensation setting (for a given amplifier band-width), shows the usefulness of the method in improving the signal to noise ratio.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A coaxial capacitance voltage divider with a ratio of 110 and a rise time much less than 2.5 ns was developed for use with a transmission line pulse generator capable of producing 100 kV rectangular pulses of 2 mu s duration. The low voltage arm of the divider is a 3 cm long tube of titania (TiO2) turned out from a cylindrical compact. The compact was made by first pressing titania powder using a suitable binder and then sintering at controlled temperatures. The tube was slipped over the terminating end of the pulse-forming cable to form the divider with the cable capacitance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Subtraction of one complex spatial function from another can be accomplished holographically by shifting the phase of the reference beam by pi between the two exposures. A simple and reliable system for this purpose, which makes use of the fact that the beam from a gas laser is usually plane-polarized, is described, and its application to obtain the equivalent of a dark field with the frozen-fringe technique in holographic interferometry is demonstrated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Describes a simple triggered vacuum gap developed for initiating electric arcs in vacuum which uses the property that the voltage required to breakdown a gap in vacuum in the presence of a solid insulating material is considerably less than the voltage required in the absence of such material. In this triggered vacuum gap a solid insulating material is used in the angular space between the main cathode and the concentric trigger electrode forming the auxiliary gap. Different materials like epoxy resin, Teflon (PTFE) and mica have been used. The trigger voltage was found to vary in the range 560-1840 V. The results with epoxy and Teflon were unsatisfactory because the trigger voltages showed wide scatter and the auxiliary gap was soon bridged by metal particles eroded from the electrodes. Though the trigger voltages required with mica were relatively high, consistent triggering could be obtained for a large number of trials before the auxiliary gap was bridged. This was probably due to better thermal stability of mica as compared with either epoxy or Teflon.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We propose and demonstrate a dynamic point spread function (PSF) for single and multiphoton fluorescence microscopy. The goal is to generate a PSF whose shape and size can be maneuvered from highly localized to elongated one, thereby allowing shallow-to-depth excitation capability during active imaging. The PSF is obtained by utilizing specially designed spatial filter and dynamically altering the filter parameters. We predict potential applications in nanobioimaging and fluorescence microscopy.