986 resultados para COUNTER-CURRENT CHROMATOGRAPHY


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Jackson, Richard, Writing the War on Terrorism: Language, Politics and Counter-terrorism (Manchester: Manchester University Press, 2005), pp.viii + 232 RAE2008

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The concept of pellicular particles was suggested by Horváth and Lipsky over fifty years ago. The reasoning behind the idea of these particles was to improve column efficiency by shortening the pathways analyte molecules can travel, therefore reducing the effect of the A and C terms. Several types of shell particles were successfully marketed around this time, however with the introduction of high quality fully porous silica under 10 μm, shell particles faded into the background. In recent years a new generation of core shell particles have become popular within the separation science community. These particles allow fast and efficient separations that can be carried out on conventional HPLC systems. Chapter 1 of this thesis introduces the chemistry of chromatographic stationary phases, with an emphasis on silica bonded phases, particularly focusing on the current state of technology in this area. The main focus is on superficially porous silica particles as a support material for liquid chromatography. A summary of the history and development of these particles over the past few decades is explored, along with current methods of synthesis of shell particles. While commercial shell particles have a rough outer surface, Chapter 2 focuses on the novel approach to growth of smooth surface superficially porous particles in a step-by-step manner. From the Stöber methodology to the seeded growth technique, and finally to the layer-bylayer growth of the porous shell. The superficially porous particles generated in this work have an overall diameter of 2.6 μm with a 350 nm porous shell; these silica particles were characterised using SEM, TEM and BET analysis. The uniform spherical nature of the particles along with their surface area, pore size and particle size distribution are examined in this chapter. I discovered that these smooth surface shell particles can be synthesised to give comparable surface area and pore size in comparison to commercial brands. Chapter 3 deals with the bonding of the particles prepared in Chapter 2 with C18 functionality; one with a narrow and one with a wide particle size distribution. This chapter examines the chromatographic and kinetic performance of these silica stationary phases, and compares them to a commercial superficially porous silica phase with a rough outer surface. I found that the particle size distribution does not seem to be the major contributor to the improvement in efficiency. The surface morphology of the particles appears to play an important role in the packing process of these particles and influences the Van Deemter effects. Chapter 4 focuses on the functionalisation of 2.6 μm smooth surface superficially porous particles with a variety of fluorinated and phenyl silanes. The same processes were carried out on 3.0 μm fully porous silica particles to provide a comparison. All phases were accessed using elemental analysis, thermogravimetric analysis, nitrogen sorption analysis and chromatographically evaluated using the Neue test. I observed comparable results for the 2.6 μm shell pentaflurophenyl propyl silica when compared to 3.0 μm fully porous silica. Chapter 5 moves towards nano-particles, with the synthesis of sub-1 μm superficially porous particles, their characterisation and use in chromatography. The particles prepared are 750 nm in total with a 100 nm shell. All reactions and testing carried out on these 750 nm core shell particles are also carried out on 1.5 μm fully porous particles in order to give a comparative result. The 750 nm core shell particles can be synthesised quickly and are very uniform. The main drawback in their use for HPLC is the system itself due to the backpressure experienced using sub – 1 μm particles. The synthesis of modified Stöber particles is also examined in this chapter with a range of non-porous silica and shell silica from 70 nm – 750 nm being tested for use on a Langmuir – Blodgett system. These smooth surface shell particles have only been in existence since 2009. The results displayed in this thesis demonstrate how much potential smooth surface shell particles have provided more in-depth optimisation is carried out. The results on packing studies reported in this thesis aims to be a starting point for a more sophisticated methodology, which in turn can lead to greater chromatographic improvements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Size-exclusion or gel filtration chromatography is one of the most popular methods for determining the sizes of proteins. Proteins in solution, or other macromolecules, are applied to a column with a defined support medium. The behavior of the protein depends on its size and that of the pores in the medium. If the protein is small relative to the pore size, it will partition into the medium and emerge from the column after larger proteins. Besides a protein's size, this technique can also be used for protein purification, analysis of purity, and study of interactions between proteins. In this unit protocols are provided for size-exclusion high-performance liquid chromatography (SE-HPLC) and for conventional gel filtration, including calibration of columns (in terms of the Stokes radius) using protein standards.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potential for coupling technologies to deliver new, improved forms of bioanalysis is still in its infancy. We review a number of examples in which coupling has been successful, with special emphasis on combining surface-plasmon-resonance biosensors with mass spectrometry. We give an overview of current progress towards combining biosensor-based bioanalysis with chemical analysis for confirmation of paralytic shellfish poisons that are marine toxins. This comprehensive approach could be an alternative to the official methods currently used (e.g., animal testing and high-performance liquid chromatography with fluorescence detection) and could serve as a model for many more such applications. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives
To explore the role of evidence of effectiveness when making decisions about over-the-counter (OTC) medication and to ascertain whether evidence-based medicine training raised awareness in decision-making. Additionally, this work aimed to complement the findings of a previous study because all participants in this current study had received training in evidence-based medicine (unlike the previous participants).

Methods
Following ethical approval and an e-mailed invitation, face-to-face, semi-structured interviews were conducted with newly registered pharmacists (who had received training in evidence-based medicine as part of their MPharm degree) to discuss the role of evidence of effectiveness with OTC medicines. Interviews were recorded and transcribed verbatim. Following transcription, all data were entered into the NVivo software package (version 8). Data were coded and analysed using a constant comparison approach.

Key findings
Twenty-five pharmacists (7 males and 18 females; registered for less than 4 months) were recruited and all participated in the study. Their primary focus with OTC medicines was safety; sales of products (including those that lack evidence of effectiveness) were justified provided they did no harm. Meeting patient expectation was also an important consideration and often superseded evidence. Despite knowledge of the concept, and an awareness of ethical requirements, an evidence-based approach was not routinely implemented by these pharmacists. Pharmacists did not routinely utilize evidence-based resources when making decisions about OTC medicines and some felt uncomfortable discussing the evidence-base for OTC products with patients.

Conclusions
The evidence-based medicine training that these pharmacists received appeared to have limited influence on OTC decision-making. More work could be conducted to ensure that an evidence-based approach is routinely implemented in practice

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have developed a new technique for quantifying methionine sulfoxide (MetSO) in protein to assess levels of oxidative stress in physiological systems. In this procedure, samples are hydrolyzed with methanesulfonic acid (MSA) in order to avoid the conversion of MetSO to methionine (Met) that occurs during hydrolysis of protein in HCl. The hydrolysate is fractionated on a cation exchange column to remove the nonvolatile MSA from amino acids, and the amino acids are then derivatized as their trimethylsilyl esters for analysis by selected ion monitoring-gas chromatography/mass spectrometry. The limit of detection of the assay is 200 pmol of MetSO per analysis, and the interassay coefficient of variation is 5.8%. Compared to current methods, the SIM-GC/MS assay avoids the potential for conversion of Met to MetSO during sample preparation, requires less sample preparation time, has lower variability, and uses mass spectrometry for sensitive and specific analyte detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The application of electric bias across tip–surface junctions in scanning probe microscopy can readily induce surface and bulk electrochemical processes that can be further detected though changes in surface topography, Faradaic or conductive currents, or electromechanical strain responses. However, the basic factors controlling tip-induced electrochemical processes, including the relationship between applied tip bias and the thermodynamics of local processes, remains largely unexplored. Using the model Li-ion reduction reaction on the surface in Li-ion conducting glass ceramic, we explore the factors controlling Li-metal formation and find surprisingly strong effects of atmosphere and back electrode composition on the process. We find that reaction processes are highly dependent on the nature of the counter electrode and environmental conditions. Using a nondepleting Li counter electrode, Li particles could grow significantly larger and faster than a depleting counter electrode. Significant Li ion depletion leads to the inability for further Li reduction. Time studies suggest that Li diffusion replenishes the vacant sites after 12 h. These studies suggest the feasibility of SPM-based quantitative electrochemical studies under proper environmental controls, extending the concepts of ultramicroelectrodes to the single-digit nanometer scale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The high-current fast electron beams generated in high-intensity laser-solid interactions require the onset of a balancing return current in order to propagate in the target material. Such a system of counter-streaming electron currents is unstable to a variety of instabilities such as the current-filamentation instability and the two-stream instability. An experimental study aimed at investigating the role of instabilities in a system of symmetrical counter-propagating fast electron beams is presented here for the first time. The fast electron beams are generated by double-sided laser-irradiation of a layered target foil at laser intensities above 10(19) W/cm(2). High-resolution X-ray spectroscopy of the emission from the central Ti layer shows that locally enhanced energy deposition is indeed achieved in the case of counter-propagating fast electron beams

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Long metallic nanowires combine crucial factors for nonconservative current-driven atomic motion. These systems have degenerate vibrational frequencies, clustered about a Kohn anomaly in the dispersion relation, that can couple under current to form nonequilibrium modes of motion growing exponentially in time. Such motion is made possible by nonconservative current-induced forces on atoms, and we refer to it generically as the waterwheel effect. Here the connection between the waterwheel effect and the stimulated directional emission of phonons propagating along the electron flow is discussed in an intuitive manner. Nonadiabatic molecular dynamics show that waterwheel modes self-regulate by reducing the current and by populating modes in nearby frequency, leading to a dynamical steady state in which nonconservative forces are counter-balanced by the electronic friction. The waterwheel effect can be described by an appropriate effective nonequilibrium dynamical response matrix. We show that the current-induced parts of this matrix in metallic systems are long-ranged, especially at low bias. This nonlocality is essential for the characterisation of nonconservative atomic dynamics under current beyond the nanoscale.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A large number of expensive, but highly profitable branded prescription drugs will go off-patent in the USA between 2011 and 2015. Their revenues are crucial to fund the immense costs associated with the development of an innovative drug. The rising cost pressure on pharmaceutical stakeholders has increased the demand for more affordable medications, as provided by the branded drug's generic counterpart. Yet, research based incumbents are moving beyond the traditional late lifecycle strategies and deploy more aggressive tactics in order to protect their brands, as seen with Pfizer's Lipitor!. It is doubtful, whether these efforts will help the blockbuster business model to resist current market conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La phosphorylation des protéines constitue l’une des plus importantes modifications post-traductionnelles (PTMs) et intervient dans de multiples processus physiologiques tels, la croissance, la différenciation cellulaire, l’apoptose, etc. En dépit de son importance, l’analyse des phosphoprotéines demeure une tâche difficile en raison de leur nature dynamique (car la phosphorylation des protéines est un processus réversible) et de leur faible abondance relative. En effet, la détermination des sites de phosphorylation est souvent difficile car les phosphopeptides sont souvent difficiles à détecter par des méthodes d’analyse chromatographique classique et par spectrométrie de masse (MS). De récentes études ont démontré que les nombreuses méthodes d’enrichissement de phosphopeptides existantes ne sont pas complètes, et que le nombre total de phosphopeptides détectés ne chevauchent pas complètement ces méthodes. C’est pour cela qu’il existe une nécessité de combler les lacunes des méthodes d’enrichissement existantes afin d’avoir des analyses phosphoprotéomiques plus complètes. Dans cette étude, nous avons utilisé les liquides ioniques (LI), plus particulièrement les sels d’imidazolium, comme une technique d’enrichissement alternative, dans le but de favoriser une extraction sélective de phosphopeptides présents en solution. Les sels d’imidazolium ont donc été utilisés en raison de leurs propriétés physico-chimiques "facilement" ajustables selon la nature des substituants sur le noyau imidazolium et la nature de l’anion. Les sels de monoimidazolium et de bis-imidazolium possédant respectivement des chaînes linéaires à 4, 12 et 16 atomes de carbone et ayant différents anions ont été synthétisés et utilisés pour effectuer des extractions liquide-liquide et solide-liquide des phosphopeptides en solution. Dans un premier temps, des extractions liquide-liquide ont été réalisées en utilisant un liquide ionique (LI) ayant une chaine linéaire de 4 atomes de carbone. Ces extractions réalisées avec le bis(trifluoromethanesulfonyl) amide de 3-butyl-1-methylimidazolium (BMIM-NTf2) et l’hexafluorophosphate de 3-butyl-1-methylimidazolium (BMIM-PF6) n’ont pas montré une extraction notable du PPS comparativement au PN. Dans un deuxième temps, des extractions solide-liquide ont été réalisées en fonctionnalisant des particules solides avec des sels d’imidazolium possédant des chaines linéaires de 12 ou 16 atomes de carbone. Ces extractions ont été faites en utilisant un phosphopentapeptide Ac-Ile-pTyr-Gly-Glu-Phe-NH2 (PPS) en présence de 2 analogues acides non-phosphorylés. Il a été démontré que les sels d’imidazolium à chaine C12 étaient meilleurs pour extraire le PPS que les deux autres peptides PN (Ac-Ile-Tyr-Gly-Glu-Phe-NH2) et PE (Ac-Glu-Tyr-Gly-Glu-Phe-NH2) L’électrophorèse capillaire (CE) et la chromatographie liquide à haute performance couplée à la spectrométrie de masse (LC-MS) ont été utilisées pour quantifier le mélange des trois peptides avant et après extraction ; dans le but de mesurer la sélectivité et l’efficacité d’extraction de ces peptides par rapport à la composition chimique du liquide ionique utilisé.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article analyses the counter-terrorist operations carried out by Captain (later Major General) Orde Wingate in Palestine in 1938, and considers whether these might inform current operations. Wingate's Special Night Squads were formed from British soldiers and Jewish police specifically to counter terrorist and sabotage attacks. Their approach escalated from interdicting terrorist gangs to pre-emptive attacks on suspected terrorist sanctuaries to reprisal attacks after terrorist atrocities. They continued the British practice of using irregular units in counter-insurgency, which was sustained into the postwar era and contributed to the evolution of British Special Forces. Wingate's methods proved effective in pacifying terrorist-infested areas and could be applied again, but only in the face of 'friction' arising from changes in cultural attitudes since the 1930s, and from the political-strategic context of post-2001 counter-insurgent and counter-terrorist operations. In some cases, however, public opinion might not preclude the use of some of Wingate's techniques.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Automated border control (ABC) is concerned with fast and secure processing for intelligence-led identification. The FastPass project aims to build a harmonised, modular reference system for future European ABC. When biometrics is taken on board as identity, spoofing attacks become a concern. This paper presents current research in algorithm development for counter-spoofing attacks in biometrics. Focussing on three biometric traits, face, fingerprint, and iris, it examines possible types of spoofing attacks, and reviews existing algorithms reported in relevant academic papers in the area of countering measures to biometric spoofing attacks. It indicates that the new developing trend is fusion of multiple biometrics against spoofing attacks.