955 resultados para COOLING SYSTEMS


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Increased device density, switching speeds of integrated circuits and decrease in package size is placing new demands for high power thermal-management. The convectional method of forced air cooling with passive heat sink can handle heat fluxes up-to 3-5W/cm2; however current microprocessors are operating at levels of 100W/cm2, This demands the usage of novel thermal-management systems. In this work, water-cooling systems with active heat sink are embedded in the substrate. The research involved fabricating LTCC substrates of various configurations - an open-duct substrate, the second with thermal vias and the third with thermal vias and free-standing metal columns and metal foil. Thermal testing was performed experimentally and these results are compared with CFD results. An overall thermal resistance for the base substrate is demonstrated to be 3.4oC/W-cm2. Addition of thermal vias reduces the effective resistance of the system by 7times and further addition of free standing columns reduced it by 20times.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Greenhouses have become an invaluable source of year-round food production. Further development of viable and efficient high performance greenhouses is important for future food security. Closing the greenhouse envelope from the environment can provide benefits in space heating energy savings, pest control, and CO2 enrichment. This requires the application of a novel air conditioning system to handle the high cooling loads experienced by a greenhouse. Liquid desiccant air-conditioning (LDAC) have been found to provide high latent cooling capacities, which is perfect for the application of a humid greenhouse microclimate. TRNSYS simulations were undertaken to study the feasibility of two liquid desiccant dehumidification systems based on their capacity to control the greenhouse microclimate, and their cooling performance. The base model (B-LDAC) included a natural gas boiler, and two cooling systems for seasonal operation. The second model (HP-LDAC) was a hybrid liquid desiccant-heat pump dehumidification system. The average tCOPdehum and tCOPtotal of the B-LDAC system increased from 0.40 and 0.56 in January to 0.94 and 1.09 in June. Increased load and performance during a sample summer day improved these values to 3.5 and 3.0, respectively. The average eCOPdehum and eCOPtotal values were 1.0 and 1.8 in winter, and 1.7 and 2.1 in summer. The HP-LDAC system produced similar daily performance trends where the annual average eCOPdehum and eCOPtotal values were 1.3 and 1.2, but the sample day saw peaks of 2.4 and 3.2, respectively. The B-LDAC and HP-LDAC results predicted greenhouse temperatures exceeding 30°C for 34% and 17% of the month of July, respectively. Similarly, humidity levels increased in summer months, with a maximum of 14% of the time spent over 80% in May for both models. The percentage of annual savings in space heating energy associated with closing the greenhouse to ventilation was 34%. The additional annual regeneration energy input was reduced by 26% to 526 kWhm-2, with the implementation of a heat recovery ventilator on the regeneration exhaust air. The models also predicted an electrical energy input of 245 kWhm-2 and 305 kWhm-2 for the B-LDAC and HP-LDAC simulations, respectively.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The internal combustion (IC) engines exploits only about 30% of the chemical energy ejected through combustion, whereas the remaining part is rejected by means of cooling system and exhausted gas. Nowadays, a major global concern is finding sustainable solutions for better fuel economy which in turn results in a decrease of carbon dioxide (CO2) emissions. The Waste Heat Recovery (WHR) is one of the most promising techniques to increase the overall efficiency of a vehicle system, allowing the recovery of the heat rejected by the exhaust and cooling systems. In this context, Organic Rankine Cycles (ORCs) are widely recognized as a potential technology to exploit the heat rejected by engines to produce electricity. The aim of the present paper is to investigate a WHR system, designed to collect both coolant and exhausted gas heats, coupled with an ORC cycle for vehicle applications. In particular, a coolant heat exchanger (CLT) allows the heat exchange between the water coolant and the ORC working fluid, whereas the exhausted gas heat is recovered by using a secondary circuit with diathermic oil. By using an in-house numerical model, a wide range of working conditions and ORC design parameters are investigated. In particular, the analyses are focused on the regenerator location inside the ORC circuits. Five organic fluids, working in both subcritical and supercritical conditions, have been selected in order to detect the most suitable configuration in terms of energy and exergy efficiencies.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Ground-source heat pump (GSHP) systems represent one of the most promising techniques for heating and cooling in buildings. These systems use the ground as a heat source/sink, allowing a better efficiency thanks to the low variations of the ground temperature along the seasons. The ground-source heat exchanger (GSHE) then becomes a key component for optimizing the overall performance of the system. Moreover, the short-term response related to the dynamic behaviour of the GSHE is a crucial aspect, especially from a regulation criteria perspective in on/off controlled GSHP systems. In this context, a novel numerical GSHE model has been developed at the Instituto de Ingeniería Energética, Universitat Politècnica de València. Based on the decoupling of the short-term and the long-term response of the GSHE, the novel model allows the use of faster and more precise models on both sides. In particular, the short-term model considered is the B2G model, developed and validated in previous research works conducted at the Instituto de Ingeniería Energética. For the long-term, the g-function model was selected, since it is a previously validated and widely used model, and presents some interesting features that are useful for its combination with the B2G model. The aim of the present paper is to describe the procedure of combining these two models in order to obtain a unique complete GSHE model for both short- and long-term simulation. The resulting model is then validated against experimental data from a real GSHP installation.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Direct evaporative cooling systems (DECS) based on sprinkling water indoors in the form of droplets and indirect evaporative cooling systems (IECS), characterized by the use of wetted roof or wall surfaces for cooling without increasing the indoor air moisture, consist of interesting bioclimatic strategies still not quite explored in Brazil. This study aims to evaluate the use of a particular form of IECS (which combines evaporative cooling and thermal mass brought about by a water reservoir) for indoor thermal control in warm conditions in Curitiba, Two test cells were initially built, monitored and compared to each other: a control module (CM) and an experimental module (EM), the latter provided with an evaporative pond. A subsequent configuration of the system which cancels out the evaporative function of the system and that is solely based on the increase of thermal mass, was tested in a second monitoring round. A third configuration of EM combinig evaporative cooling and the increase of termal mass was tested. Results showed a higher effectiveness of the IECS for the indoor cooling of the tested cells. The average temperature in EM was reduced in 2.5°C and the maximum temperature was reduced in 8.0°C in comparison with the CM. Results also showed a strong relation between the wet-bulb temperature depression and the internal temperature decrease achieved by the evaporative cooling strategy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper derives a general procedure for the numerical solution of the Lindblad equations that govern the coherences arising from multicoloured light interacting with a multilevel system. A systematic approach to finding the conservative and dissipative terms is derived and applied to the laser cooling of p-block elements. An improved numerical method is developed to solve the time-dependent master equation and results are presented for transient cooling processes. The method is significantly more robust, efficient and accurate than the standard method and can be applied to a broad range of atomic and molecular systems. Radiation pressure forces and the formation of dynamic dark states are studied in the gallium isotope 66Ga.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We present a one-dimensional scattering theory which enables us to describe a wealth of effects arising from the coupling of the motional degree of freedom of scatterers to the electromagnetic field. Multiple scattering to all orders is taken into account. The theory is applied to describe the scheme of a Fabry-Perot resonator with one of its mirrors moving. The friction force, as well as the diffusion, acting on the moving mirror is derived. In the limit of a small reflection coefficient, the same model provides for the description of the mechanical effect of light on an atom moving in front of a mirror.