519 resultados para COAXIAL CABLES
Resumo:
Se presenta la modalidad educativa desarrollada en el centro privado de educación especial, El Molino (Pamplona), donde se ofertan las correspondientes aulas de Formativa Común y diferentes talleres: madera, textil, horticultura, cerámica, metal-electricidad y hogar. En la elaboración de las unidades didácticas se tiene presente que el alumno debe realizar aprendizajes de tareas básicas y polivalentes, con la finalidad de que pueda integrarse en diferentes puestos de trabajo, fomentando su autonomía personal, laboral. La creación de una aplicación informática en el Taller del Metal y Electricidad ha sido un buen complemento en las enseñanzas del profesor y en la motivación del alumno.
Resumo:
Resumen basado en el de la publicaci??n
Resumo:
To ensure minimum loss of system security and revenue it is essential that faults on underground cable systems be located and repaired rapidly. Currently in the UK, the impulse current method is used to prelocate faults, prior to using acoustic methods to pinpoint the fault location. The impulse current method is heavily dependent on the engineer's knowledge and experience in recognising/interpreting the transient waveforms produced by the fault. The development of a prototype real-time expert system aid for the prelocation of cable faults is described. Results from the prototype demonstrate the feasibility and benefits of the expert system as an aid for the diagnosis and location of faults on underground cable systems.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
We are developing two-layered Yttrium Barium Copper Oxide (YBCO) thin film structures for energy efficient data links for superconducting electronics and present the results of their property measurements. High temperature superconductors (HTS) are advantageous for the implementation of energy-efficient cables interconnecting low temperature superconductor-based circuits and other cryogenic electronics circuits at higher temperature stages. The advantages of the HTS cables come from their low loss and low dispersion properties, allowing ballistic transfer of low power signals with very high bandwidth, low heat conduction and negligible inter-line crosstalk. The microstrip line cable geometry for typical materials is a two-layered film, in which the two superconducting layers are separated by an insulation layer with a minimized permittivity. We have made a proof of concept design of two YBCO films grown by pulsed laser deposition and then assembled into a sandwich with uniform insulating interlayer of tens of micrometers thick. We report on results obtained from such systems assembled in different ways. Structural and electromagnetic properties have been examined on individual films and on the corresponding sandwich composite. © 2013 IEEE.
Resumo:
Foi estudado a viabilidade de aplicação do arranjo coplanar de bobinas nas sondas de perfilagem em poço por indução eletromagnética. Paralelamente foram geradas as respostas do convencional arranjo coaxial, que é o amplamente utilizado nas sondas comerciais, com o propósito de elaborar uma análise comparativa. Através da solução analítica (meios homogêneos) e semi-analítica (meios heterogêneos) foram geradas inicialmente as respostas para modelos mais simples, tais como os do (1) meio homogêneo, isotrópico e ilimitado; (2) uma casca cilíndrica simulando a frente de invasão; (3) duas cascas cilíndricas para simular o efeito annulus; (4) uma interface plana e dois semi-espaços simulando o contato entre duas camadas espessas e (5) uma camada plano-horizontal e dois semi-espaços iguais. Apesar da simplicidade destes modelos, eles permitem uma análise detalhada dos efeitos que alguns parâmetros geoelétricos têm sobre as respostas. Aí então, aplicando ainda as condições de contorno nas fronteiras (Sommerfeld Boundary Value Problem), obtivemos as soluções semi-analíticas que nos permitiram simular as respostas em modelos relativamente mais complexos, tais como (1) zonas de transição gradacional nas frentes de invasão; (2) seqüências de camadas plano-paralelas horizontais e inclinadas; (3) seqüências laminadas que permitem simular meios anisotrópicos e (4) passagem gradacional entre duas camadas espessas. Concluimos que o arranjo coplanar de bobinas pode ser uma ferramenta auxiliar na (1) demarcação das interfaces de camadas espessas; (2) posicionamento dos reservatórios de pequenas espessuras; (3) avaliação de perfis de invasão e (4) localizar variações de condutividade azimutalmente.
Resumo:
A ferramenta de indução triaxial ou multicomponente foi desenvolvida recentemente para solucionar os problemas de medição da convencional perfilagem de indução em formações anisotrópicas. Neste trabalho são apresentadas as respostas da sonda de indução triaxial em reservatórios que possuem seqüências finamente laminadas de arenito e folhelho. Reservatórios como estes apresentam a conhecida anisotropia macroscópica, portanto, os resultados demonstrarão a existência de uma resistividade horizontal e outra vertical. Devido a sonda triaxial de indução apresentar dois pares de bobinas coplanares, os quais em geral fornecem os valores de resistividade vertical, este trabalho apresenta inicialmente um estudo analítico e qualitativo das respostas obtidas pelo arranjo coplanar onde o transmissor é tratado como um dipolo. Também será apresentada a solução analítica em que a bobina transmissora é considerada como um loop de dimensão finita.
Resumo:
The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent (R) was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancy-driven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-epsilon turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.
Resumo:
The objective of this work is to predict the temperature distribution of partially submersed umbilical cables under different operating and environmental conditions. The commercial code Fluent® was used to simulate the heat transfer and the air fluid flow of part of a vertical umbilical cable near the air-water interface. A free-convective three-dimensional turbulent flow in open-ended vertical annuli was solved. The influence of parameters such as the heat dissipating rate, wind velocity, air temperature and solar radiation was analyzed. The influence of the presence of a radiation shield consisting of a partially submersed cylindrical steel tube was also considered. The air flow and the buoyancydriven convective heat transfer in the annular region between the steel tube and the umbilical cable were calculated using the standard k-ε turbulence model. The radiative heat transfer between the umbilical external surface and the radiation shield was calculated using the Discrete Ordinates model. The results indicate that the influence of a hot environment and intense solar radiation may affect the umbilical cable performance in its dry portion.
Resumo:
The velocity and mixing field of two turbulent jets configurations have been experimentally characterized by means of cold- and hot-wire anemometry in order to investigate the effects of the initial conditions on the flow development. In particular, experiments have been focused on the effect of the separation wall between the two streams on the flow field. The results of the experiments have pointed out that the wake behind a thick wall separating wall has a strong influence on the flow field evolution. For instance, for nearly unitary velocity ratios, a clear vortex shedding from the wall is observable. This phenomenon enhances the mixing between the inner and outer shear layer. This enhancement in the fluctuating activity is a consequence of a local absolute instability of the flow which, for a small range of velocity ratios, behaves as an hydrodynamic oscillator with no sensibility to external perturbations. It has been suggested indeed that this absolute instability can be used as a passive method to control the flow evolution. Finally, acoustic excitation has been applied to the near field in order to verify whether or not the observed vortex shedding behind the separating wall is due to a global oscillating mode as predicted by the theory. A new scaling relationship has been also proposed to determine the preferred frequency for nearly unitary velocity ratios. The proposed law takes into account both the Reynolds number and the velocity ratio dependence of this frequency and, therefore, improves all the previously proposed relationships.
Resumo:
The current design life of nuclear power plant (NPP) could potentially be extended to 80 years. During this extended plant life, all safety and operationally relevant Instrumentation & Control (I&C) systems are required to meet their designed performance requirements to ensure safe and reliable operation of the NPP, both during normal operation and subsequent to design base events. This in turn requires an adequate and documented qualification and aging management program. It is known that electrical insulation of I&C cables used in safety related circuits can degrade during their life, due to the aging effect of environmental stresses, such as temperature, radiation, vibration, etc., particularly if located in the containment area of the NPP. Thus several condition monitoring techniques are required to assess the state of the insulation. Such techniques can be used to establish a residual lifetime, based on the relationship between condition indicators and ageing stresses, hence, to support a preventive and effective maintenance program. The object of this thesis is to investigate potential electrical aging indicators (diagnostic markers) testing various I&C cable insulations subjected to an accelerated multi-stress (thermal and radiation) aging.
Resumo:
The work presented in this thesis is focused on the open-ended coaxial-probe frequency-domain reflectometry technique for complex permittivity measurement at microwave frequencies of dispersive dielectric multilayer materials. An effective dielectric model is introduced and validated to extend the applicability of this technique to multilayer materials in on-line system context. In addition, the thesis presents: 1) a numerical study regarding the imperfectness of the contact at the probe-material interface, 2) a review of the available models and techniques, 3) a new classification of the extraction schemes with guidelines on how they can be used to improve the overall performance of the probe according to the problem requirements.
Resumo:
The safety systems of nuclear power plants rely on low-voltage power, instrumentation and control cables. Inside the containment area, cables operate in harsh environments, characterized by relatively high temperature and gamma-irradiation. As these cables are related to fundamental safety systems, they must be able to withstand unexpected accident conditions and, therefore, their condition assessment is of utmost importance as plants age and lifetime extensions are required. Nowadays, the integrity and functionality of these cables are monitored mainly through destructive test which requires specific laboratory. The investigation of electrical aging markers which can provide information about the state of the cable by non-destructive testing methods would improve significantly the present diagnostic techniques. This work has been made within the framework of the ADVANCE (Aging Diagnostic and Prognostics of Low-Voltage I\&C Cables) project, a FP7 European program. This Ph.D. thesis aims at studying the impact of aging on cable electrical parameters, in order to understand the evolution of the electrical properties associated with cable degradation. The identification of suitable aging markers requires the comparison of the electrical property variation with the physical/chemical degradation mechanisms of polymers for different insulating materials and compositions. The feasibility of non-destructive electrical condition monitoring techniques as potential substitutes for destructive methods will be finally discussed studying the correlation between electrical and mechanical properties. In this work, the electrical properties of cable insulators are monitored and characterized mainly by dielectric spectroscopy, polarization/depolarization current analysis and space charge distribution. Among these techniques, dielectric spectroscopy showed the most promising results; by means of dielectric spectroscopy it is possible to identify the frequency range where the properties are more sensitive to aging. In particular, the imaginary part of permittivity at high frequency, which is related to oxidation, has been identified as the most suitable aging marker based on electrical quantities.