97 resultados para CARDIOVERTER-DEFIBRILLATORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is today precluded to patients bearing active implantable medical devices AIMDs). The great advantages related to this diagnostic modality, together with the increasing number of people benefiting from implantable devices, in particular pacemakers(PM)and carioverter/defibrillators (ICD), is prompting the scientific community the study the possibility to extend MRI also to implanted patients. The MRI induced specific absorption rate (SAR) and the consequent heating of biological tissues is one of the major concerns that makes patients bearing metallic structures contraindicated for MRI scans. To date, both in-vivo and in-vitro studies have demonstrated the potentially dangerous temperature increase caused by the radiofrequency (RF) field generated during MRI procedures in the tissues surrounding thin metallic implants. On the other side, the technical evolution of MRI scanners and of AIMDs together with published data on the lack of adverse events have reopened the interest in this field and suggest that, under given conditions, MRI can be safely performed also in implanted patients. With a better understanding of the hazards of performing MRI scans on implanted patients as well as the development of MRI safe devices, we may soon enter an era where the ability of this imaging modality may be more widely used to assist in the appropriate diagnosis of patients with devices. In this study both experimental measures and numerical analysis were performed. Aim of the study is to systematically investigate the effects of the MRI RF filed on implantable devices and to identify the elements that play a major role in the induced heating. Furthermore, we aimed at developing a realistic numerical model able to simulate the interactions between an RF coil for MRI and biological tissues implanted with a PM, and to predict the induced SAR as a function of the particular path of the PM lead. The methods developed and validated during the PhD program led to the design of an experimental framework for the accurate measure of PM lead heating induced by MRI systems. In addition, numerical models based on Finite-Differences Time-Domain (FDTD) simulations were validated to obtain a general tool for investigating the large number of parameters and factors involved in this complex phenomenon. The results obtained demonstrated that the MRI induced heating on metallic implants is a real risk that represents a contraindication in extending MRI scans also to patient bearing a PM, an ICD, or other thin metallic objects. On the other side, both experimental data and numerical results show that, under particular conditions, MRI procedures might be consider reasonably safe also for an implanted patient. The complexity and the large number of variables involved, make difficult to define a unique set of such conditions: when the benefits of a MRI investigation cannot be obtained using other imaging techniques, the possibility to perform the scan should not be immediately excluded, but some considerations are always needed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Decreased exercise capacity, and reduction in peak oxygen uptake are present in most patients affected by hypertrophic cardiomyopathy (HCM) . In addition an abnormal blood pressure response during a maximal exercise test was seen to be associated with high risk for sudden cardiac death in adult patients affected by HCM. Therefore exercise test (CPET) has become an important part of the evaluation of the HCM patients, but data on its role in patients with HCM in the pediatric age are quite limited. Methods and results Between 2004 and 2010, using CPET and echocardiography, we studied 68 children (mean age 13.9 ± 2 years) with HCM. The exercise test was completed by all the patients without adverse complications. The mean value of achieved VO2 max was 31.4 ± 8.3 mL/Kg/min which corresponded to 77.5 ± 16.9 % of predicted range. 51 patients (75%) reached a subnormal value of VO2max. On univariate analysis the achieved VO2 as percentage of predicted and the peak exercise systolic blood pressure (BP) Z score were inversely associated with max left ventricle (LV) wall thickness, with E/Ea ratio, and directly related with Ea and Sa wave velocities No association was found with the LV outflow tract gradient. During a mean follow up of 2.16 ± 1.7 years 9 patients reached the defined clinical end point of death, transplantation, implanted cardioverter defibrillator (ICD) shock, ICD implantation for secondary prevention or myectomy. Patients with peak VO2 < 52% or with peak systolic BP Z score < -5.8 had lower event free survival at follow up. Conclusions Exercise capacity is decreased in patients with HCM in pediatric age and global ventricular function seems being the most important determinant of exercise capacity in these patients. CPET seems to play an important role in prognostic stratification of children affected by HCM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In patients with ventricular tachycardia (VT) and a history of myocardial infarction, intervention with an implantable cardioverter defibrillator (ICD) can prevent sudden cardiac death and thereby reduce total mortality. However, ICD shocks are painful and do not provide complete protection against sudden cardiac death. We assessed the potential benefit of catheter ablation before implantation of a cardioverter defibrillator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Correctly performed basic life support (BLS) and early defibrillation are the most effective measures to treat sudden cardiac arrest. Audiovisual feedback improves BLS. Automated external defibrillators (AED) with feedback technology may play an important role in improving CPR quality. The aim of this simulation study was to investigate if an AED with audiovisual feedback improves CPR parameters during standard BLS performed by trained laypersons.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy-harvesting devices attract wide interest as power supplies of today's medical implants. Their long lifetime will spare patients from repeated surgical interventions. They also offer the opportunity to further miniaturize existing implants such as pacemakers, defibrillators or recorders of bio signals. A mass imbalance oscillation generator, which consists of a clockwork from a commercially available automatic wrist watch, was used as energy harvesting device to convert the kinetic energy from the cardiac wall motion to electrical energy. An MRI-based motion analysis of the left ventricle revealed basal regions to be energetically most favorable for the rotating unbalance of our harvester. A mathematical model was developed as a tool for optimizing the device's configuration. The model was validated by an in vitro experiment where an arm robot accelerated the harvesting device by reproducing the cardiac motion. Furthermore, in an in vivo experiment, the device was affixed onto a sheep heart for 1 h. The generated power in both experiments-in vitro (30 μW) and in vivo (16.7 μW)-is sufficient to power modern pacemakers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Clustering ventricular arrhythmias are the consequence of acute ventricular electrical instability and represent a challenge in the management of the growing number of patients with an implantable cardioverter-defibrillator (ICD). Triggering factors can rarely be identified. OBJECTIVES: Several studies have revealed seasonal variations in the frequency of cardiovascular events and life-threatening arrhythmias, and we sought to establish whether seasonal factors may exacerbate ventricular electrical instability leading to arrhythmia clusters and electrical storm. METHODS: Two hundred and fourteen consecutive defibrillator recipients were followed-up during 3.3 +/- 2.2 years. Arrhythmia cluster was defined as the occurrence of three or more arrhythmic events triggering appropriate defibrillator therapies within 2 weeks. Time intervals between two clusters were calculated for each month and each season, and were compared using Kruskal-Wallis test and Wilcoxon-Mann-Whitney test with Bonferroni adjustment. RESULTS: During a follow-up of 698 patient years, 98 arrhythmia clusters were observed in 51 patients; clustering ventricular arrhythmias were associated with temporal variables; they occurred more frequently in the winter and spring months than during the summer and fall. Accordingly, the time intervals between two clusters were significantly shorter during winter and spring (median and 95% CI): winter 16 (5-19), spring 11.5 (7-25), summer 34.5 (15-55), fall 50.5 (19-65), P = 0.0041. CONCLUSION: There are important seasonal variations in the incidence of arrhythmia clusters in ICD recipients. Whether these variations are related to environmental factors, change in physical activity, or psychological factors requires further study.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Antiarrhythmic drugs are used in at least 50% of patients who received an implantable cardioverter defibrillator (ICD). The potential indications for antiarrhythmic drug treatments in patients with an ICD are generally the following: reduction of the number of ventricular tachycardias (VTs) or episodes of ventricular fibrillation and therefore reduction of the number of ICD therapies, most importantly, the number of disabling ICD shocks. Accordingly, the quality of life should be improved and the battery life of the ICD extended. Moreover, antiarrhythmic drugs have the potential to increase the tachycardia cycle length to allow termination of VTs by antitachycardia pacing and reduction of the number of syncopes. In addition, supraventricular arrhythmias can be prevented or their rate controlled. Recently published or reported trials have shown the efficacy of amiodarone, sotalol and azimilide to significantly reduce the number of appropriate and inappropriate ICD shocks in patients with structural heart disease. However, the use of antiarrhythmic drugs may also have adverse effects: an increase in the defibrillation threshold, an excessive increase in the VT cycle length leading to detection failure. In this situation and when antiarrhythmic drugs are ineffective or have to be stopped because of serious side effects, catheter ablation of both monomorphic stable and pleomorphic and/or unstable VTs using modern electroanatomic mapping systems should be considered. The choice of antiarrhythmic drug treatment and the need for catheter ablation in ICD patients with frequent VTs should be individually tailored to specific clinical and electrophysiological features including the frequency, the rate, and the clinical presentation of the ventricular arrhythmia. Although VT mapping and ablation is becoming increasingly practical and efficacious, ablation of VT is mostly done as an adjunctive therapy in patients with structural heart disease and ICD experiencing multiple shocks, because the recurrence and especially the occurrence of "new" VTs after primarily successful ablation with time and disease progression have precluded a widespread use of catheter ablation as primary treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Congestive heart failure has long been one of the most serious medical conditions in the United States; in fact, in the United States alone, heart failure accounts for 6.5 million days of hospitalization each year. One important goal of heart-failure therapy is to inhibit the progression of congestive heart failure through pharmacologic and device-based therapies. Therefore, there have been efforts to develop device-based therapies aimed at improving cardiac reserve and optimizing pump function to meet metabolic requirements. The course of congestive heart failure is often worsened by other conditions, including new-onset arrhythmias, ischemia and infarction, valvulopathy, decompensation, end-organ damage, and therapeutic refractoriness, that have an impact on outcomes. The onset of such conditions is sometimes heralded by subtle pathophysiologic changes, and the timely identification of these changes may promote the use of preventive measures. Consequently, device-based methods could in the future have an important role in the timely identification of the subtle pathophysiologic changes associated with congestive heart failure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study aimed to demonstrate that the presence of late gadolinium enhancement (LGE) is a predictor of death and other adverse events in patients with suspected cardiac sarcoidosis. BACKGROUND Cardiac sarcoidosis is the most important cause of patient mortality in systemic sarcoidosis, yielding a 5-year mortality rate between 25% and 66% despite immunosuppressive treatment. Other groups have shown that LGE may hold promise in predicting future adverse events in this patient group. METHODS We included 155 consecutive patients with systemic sarcoidosis who underwent cardiac magnetic resonance (CMR) for workup of suspected cardiac sarcoid involvement. The median follow-up time was 2.6 years. Primary endpoints were death, aborted sudden cardiac death, and appropriate implantable cardioverter-defibrillator (ICD) discharge. Secondary endpoints were ventricular tachycardia (VT) and nonsustained VT. RESULTS LGE was present in 39 patients (25.5%). The presence of LGE yields a Cox hazard ratio (HR) of 31.6 for death, aborted sudden cardiac death, or appropriate ICD discharge, and of 33.9 for any event. This is superior to functional or clinical parameters such as left ventricular (LV) ejection fraction (EF), LV end-diastolic volume, or presentation as heart failure, yielding HRs between 0.99 (per % increase LVEF) and 1.004 (presentation as heart failure), and between 0.94 and 1.2 for potentially lethal or other adverse events, respectively. Except for 1 patient dying from pulmonary infection, no patient without LGE died or experienced any event during follow-up, even if the LV was enlarged and the LVEF severely impaired. CONCLUSIONS Among our population of sarcoid patients with nonspecific symptoms, the presence of myocardial scar indicated by LGE was the best independent predictor of potentially lethal events, as well as other adverse events, yielding a Cox HR of 31.6 and of 33.9, respectively. These data support the necessity for future large, longitudinal follow-up studies to definitely establish LGE as an independent predictor of cardiac death in sarcoidosis, as well as to evaluate the incremental prognostic value of additional parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The early repolarization (ER) pattern is associated with an increased risk of arrhythmogenic sudden death. However, strategies for risk stratification of patients with the ER pattern are not fully defined. OBJECTIVES This study sought to determine the role of electrophysiology studies (EPS) in risk stratification of patients with ER syndrome. METHODS In a multicenter study, 81 patients with ER syndrome (age 36 ± 13 years, 60 males) and aborted sudden death due to ventricular fibrillation (VF) were included. EPS were performed following the index VF episode using a standard protocol. Inducibility was defined by the provocation of sustained VF. Patients were followed up by serial implantable cardioverter-defibrillator interrogations. RESULTS Despite a recent history of aborted sudden death, VF was inducible in only 18 of 81 (22%) patients. During follow-up of 7.0 ± 4.9 years, 6 of 18 (33%) patients with inducible VF during EPS experienced VF recurrences, whereas 21 of 63 (33%) patients who were noninducible experienced recurrent VF (p = 0.93). VF storm occurred in 3 patients from the inducible VF group and in 4 patients in the noninducible group. VF inducibility was not associated with maximum J-wave amplitude (VF inducible vs. VF noninducible; 0.23 ± 0.11 mV vs. 0.21 ± 0.11 mV; p = 0.42) or J-wave distribution (inferior, odds ratio [OR]: 0.96 [95% confidence interval (CI): 0.33 to 2.81]; p = 0.95; lateral, OR: 1.57 [95% CI: 0.35 to 7.04]; p = 0.56; inferior and lateral, OR: 0.83 [95% CI: 0.27 to 2.55]; p = 0.74), which have previously been demonstrated to predict outcome in patients with an ER pattern. CONCLUSIONS Our findings indicate that current programmed stimulation protocols do not enhance risk stratification in ER syndrome.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The clinical role of atrial fibrillation/atrial flutter (AF-AFl) and variables predicting these arrhythmias are not well defined in patients with arrhythmogenic right ventricular dysplasia (ARVD). We hypothesized that transthoracic echocardiography (TTE) and 12-lead electrocardiography (ECG) would be helpful in predicting AF-AFl in these patients. METHODS AND RESULTS: ECGs and TTEs of 90 patients diagnosed with definite or borderline ARVD (2010 Task Force Criteria) were analyzed. Data were compared in (1) patients with AF-AFl and (2) all other patients. A total of 18 (20%) patients experienced AF-AFl during a median follow-up of 5.8 years (interquartile range 2.0-10.4). Kaplan-Meier analysis revealed reduced times to AF-AFl among patients with echocardiographic RV fractional area change <27% (P<0.001), left atrial diameter ≥24.4 mm/m(2)(parasternal long-axis, P=0.001), and right atrial short-axis diameter ≥22.1 mm/m(2)(apical 4-chamber view, P=0.05). From all ECG variables, P mitrale conferred the highest hazard ratio (3.37, 95% confidence interval 0.92-12.36, P=0.067). Five patients with AF-AFl experienced inappropriate implantable cardioverter-defibrillator (ICD) shocks compared with 4 without AF-AFl (36% vs. 9%, P=0.03). AF-AFl was more prevalent in heart-transplant patients and those who died of cardiac causes (56% vs. 16%, P=0.014). CONCLUSIONS: AF-AFl is associated with inappropriate ICD shocks, heart transplantation, and cardiac death in patients with ARVD. Evidence of reduced RV function and atrial dilation helps to identify the ARVD patients at increased risk for AF-AFl.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Catheter ablation (CA) of ventricular tachycardia (VT) is an important treatment option in patients with structural heart disease (SHD) and implantable cardioverter defibrillator (ICD). A subset of patients requires epicardial CA for VT. Objective The purpose of the study was to assess the significance of epicardial CA in these patients after a systematic sequential endocardial approach. Methods Between January 2009 and October 2012 CA for VT was analyzed. A sequential CA approach guided by earliest ventricular activation, pacemap, entrainment and stimulus to QRS-interval analysis was used. Acute CA success was assessed by programmed ventricular stimulation. ICD interrogation and 24 h-Holter ECG were used to evaluate long-term success. Results One hundred sixty VT ablation procedures in 126 consecutive patients (114 men; age 65 ± 12 years) were performed. Endocardial CA succeeded in 250 (94%) out of 265 treated VT. For 15 (6%) VT an additional epicardial CA was performed and succeeded in 9 of these 15 VT. Long-term FU (25 ± 18.2 month) showed freedom of VT in 104 pts (82%) after 1.2 ± 0.5 procedures, 11 (9%) suffered from repeated ICD shocks and 11 (9%) died due to worsening of heart failure. Conclusions Despite a heterogenic substrate for VT in SHD, endocardial CA alone results in high acute success rates. In this study additional epicardial CA following a sequential endocardial mapping and CA approach was performed in 6% of VT. Thus, due to possible complications epicardial CA should only be considered if endocardial CA fails.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sudden cardiac death is one of the main causes of mortality in patients with structural heart disease. Although an implantable cardioverter de?brillator signi?cantly reduces the mortality rate, many patients never receive a shock. Identi?cation of high-risk patients would reduce the costs associated with this therapy and prevent the deleterious effect of inappropriate discharges. As scar tissue is the substrate of ventricular arrhythmias in patients with structural heart disease, scar characterization could allow strati?cation of the risk. The objective of this article is to review the role of scar characteristics in the pathogenesis of ventricular arrhythmias in patients with structural heart disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIMS Propofol sedation has been shown to be safe for atrial fibrillation ablation and internal cardioverter-defibrillator implantation but its use for catheter ablation (CA) of ventricular tachycardia (VT) has yet to be evaluated. Here, we tested the hypothesis that VT ablation can be performed using propofol sedation administered by trained nurses under a cardiologist's supervision. METHODS AND RESULTS Data of 205 procedures (157 patients, 1.3 procedures/patient) undergoing CA for sustained VT under propofol sedation were analysed. The primary endpoint was change of sedation and/or discontinuation of propofol sedation due to side effects and/or haemodynamic instability. Propofol cessation was necessary in 24 of 205 procedures. These procedures (Group A; n = 24, 11.7%) were compared with those with continued propofol sedation (Group B; n = 181, 88.3%). Propofol sedation was discontinued due to hypotension (n = 22; 10.7%), insufficient oxygenation (n = 1, 0.5%), or hypersalivation (n = 1, 0.5%). Procedures in Group A were significantly longer (210 [180-260] vs. 180 [125-220] min, P = 0.005), had a lower per hour propofol rate (3.0 ± 1.2 vs. 3.8 ± 1.2 mg/kg of body weight/h, P = 0.004), and higher cumulative dose of fentanyl administered (0.15 [0.13-0.25] vs. 0.1 [0.05-0.13] mg, P < 0.001), compared with patients in Group B. Five (2.4%) adverse events occurred. CONCLUSION Sedation using propofol can be safely performed for VT ablation under the supervision of cardiologists. Close haemodynamic monitoring is required, especially in elderly patients and during lengthy procedures, which carrying a higher risk for systolic blood pressure decline.